2003 9625 POWER MEASUREMENT SUPPORT SOFTWARE Power Measuring Instruments Graphically process measurement data from Model 3169-20/21 easily on a PC! The Model 9625 POWER MEASUREMENT SUPPORT SOFTWARE application provides easy graphical processing on a computer of measurement data saved on the Models 3169-20/21 and 3166 CLAMP ON POWER HiTESTERs. 3169-20/21 Pow er D ata & Harm onic Data 3166 ta nic Da Harmo & a t a D Power The 9625 handles both power and harmonic measurement data simultaneously. Features ■ Time Series Graph Display Function ■ Harmonic Analysis Function Measurement data can be displayed as a time series graph. Demand data measured in different series can be overlaid on the display. Display harmonic measurement data as a graph, list or waveform. (Also compatible with the harmonic measurement data captured by Model 3166.) ■ Summary Display Function ■ Print Function Measurement data can be displayed directly in table form. ■ Daily, Weekly and Monthly Report Display Function Daily, weekly and monthly reports of demand data can be displayed. Each screen can be printed. 1 Easily display and print various screens such as graphs and spreadsheet tables Step 1. Load measurement data Load up to 16 data sets from the 3169-20/21 or 3166 at once. Measured numerical values and waveform data are recognized and displayed automatically. 1. Loading and deleting data, and changing data names, can be done easily. 2. Multiple sets of measurement data can be loaded and managed in a single file. Step 2. Select the display (screen) type Select from time series graph, summary, daily, weekly or monthly report, harmonic list, harmonic graph, harmonic waveform or settings. Step 3. Select display items (two-axis display is possible) 1. Select the data items (up to 16) to display. For graph displays, the type of graph (line or bar) can be selected. 2. Enter details for data display. (data item names, levels, etc.) Step 4. Set the start/stop times and data interval to be displayed 1. Set the data period to display. (start/stop time and data interval) • The displayed period can be easily changed by scrolling. ■ Time Series Graph Display Function (two-axes display possible) ■ The displayed graph can be set to suit particular start/stop times and data intervals. Harmonic time series graphs can be displayed. Convenient Functions (1) The horizontal (time) axis can be easily scrolled to show the desired range. (2) Upper and lower limits (measurement values) of the vertical axis can be easily set and changed. * Graph type (line, bar or stacked bar), line type (such as solid or dashed), color and details of upper and lower numerical values can be set. (3) Any desired numerical data value on a graph can be confirmed and displayed by cursor movement. (4) The display can be switched between 2D and 3D graphs. Upper/Lower Limit Setting Slider ■ Summary Display Function Summary ■ Displays a summary of the data values between specified start/stop times, at the specified data interval. Convenient Functions (1) In addition to measurement values within the period being displayed, the summary shows period, maximum, minimum and average values. (2) Measurement data names and measurement units can be edited in the summary. Daily, Weekly or Monthly Report Display ■ Displays a summary covering the total values in daily, weekly or monthly reports. Convenient Functions (1) The time axis for each total scrolls to easily change the totalized period. (2) The total time range of measurement data can be totalized in up to four sections per time period. Cursor Value 2 ■ Harmonic Display Function Harmonic data measured by the 3169-20/21 and 3166 can be displayed in various ways Harmonic Time Series Display ■ While displaying a time series graph, select the harmonic item for the vertical axis to display a time series graph of harmonics. Convenient Functions (1) Up to 32 graphs can be displayed simultaneously using 2-axes display. For one circuit measurement, up to 32 orders can be graphed. Using multiple instruments, time series of harmonics can be easily compared. (2) Any desired chronological detail can be easily confirmed using the cursors on the graph. Harmonic List Display ■ Displays harmonic data for the selected display item as a list. View the list to confirm details Simultaneously display multiple orders to confirm changes in harmonics! Simultaneously display data from multiple instruments to confirm concurrent series of harmonics! Harmonic Graph Display ■ Displays harmonic data for the selected display item as a bar graph. View the power graph to confirm trends in harmonics Harmonic Waveform Display ■ Displays the voltage and current waveforms upon which harmonic data is based. View the waveforms to confirm distortion conditions ■ Settings Display Function When you select a data name to be load, the measuring instrument model and setting conditions at measurement time are displayed. Measurement data and measurement conditions can be managed at the same time. ■ Print Function Reports and screen copies of the displayed screen can be easily printed. Convenient Functions (1) Printing results can be confirmed by print preview. (2) When creating a report, screen data can be copied and pasted into a commercial word processor program. Preview printing to confirm print results before printing Produce daily, weekly or monthly reports by one-touch report printing Graph copying is also a one-touch operation ■ 9625 Specifications ■ General Specifications Supported instrument : 3169-20, 3169-21 and 3166(CLAMP ON POWER HiTESTERs) models Operating environment : Computer: PC-AT compatible (DOS/V machine) CPU: Pentium 200 MHz or higher Memory: 128 MB or more (recommended) Hard disk: 128 MB or more free space Display: XGA (1024×768) or higher Disc device: CD-ROM drive (for installation) Operating system: Windows95/98, NT4.0, 2000, Me, XP (English edition) Internet Explorer 4.0 or later Supplied Media : One CD-R disc 3 ■ 9625 Specifications ■ Functional Specifications [Data Load/Save Functions] Loading data 3169-20/21 File extension Data format Data contents Instantaneous value, average value, maximum value, minimum value, integrated value, demand value, harmonic Data file CSV CSV Waveform data file WUI Binary Instantaneous waveform Short-interval data file BIN Binary Instantaneous values ITG CSV Instantaneous value, integrated value Demand measurement data file DEM CSV Instantaneous value, maximum value, minimum value, demand value Harmonic measurement data file HRM CSV Instantaneous value, average value, maximum value WUI Binary Setting file SET – 9625 Combined file DAT Binary 9625 Combined file Integrated measurement data file 3166 Waveform data file Save data Maximum data capacity File extension Data format DAT Binary : Up to 528 MB per data set (total composite data up to 1.5 GB) [Time Series Graph Display Function] Graph display item : Voltage, current, active power, reactive power, apparent power, power factor, frequency, Integrated value(active power, reactive power), demand, harmonic (level, content ratio, phase angle, total value, THD) Y-axis upper/lower : The display position (upper and lower display limits) of the vertical (Y) axis of a graph can be set by scroll bar or by specifying values. limit setting : Select each cycle, or 0.1, 0.2, 0.5, 1, 2, 5, 10, 15 or 30 sec.; 1, 2, Interval setting 5, 10, 15 or 30 min.; or 1, 2, 3, 4, 6, 8 or 12 h; or 1 day Display period range : An optional analysis period can be specified from the overall measurement data period setting (1) Analysis start date and time (YMD, HMS) is specified numerically (2) Analysis stop date and time (YMD, HMS) is specified numerically Display of measurement data period (measurement start and stop date and time) Reference value setting : Display set standard value Graph type selection : Line, bar, 2-axes and 3-dimensional Graph line type & color : Line type and display color can be set for each data set, and marker display is possible setting : Up to 16 types of data series (demand value, demand quantity ) Stacked bar graph can be displayed in an overlay graph display Cursor measurement : Measurement values can be displayed by the cursor Data display units setting : Engineering units (m, k, M, G, etc.) can be selected [Summary Display Function] Display item selection Daily, weekly and monthly report display Load factor calculation display Independent time range totalizing Instantaneous waveform : Select the items to display in the summary : Displays a report for the specified daily weekly or monthly period [Harmonic Display Function] Waveform display List display Graph display Cursor measurement : Displays waveform data for a specified time : Displays a list of harmonic data for a specified time : Display a bar graph of harmonic data for a specified time : Displays the value at the cursor with waveform and graph displays [Setting Display Function] Setting display : Displays a list of the setting conditions Loads setting conditions from a data file (3169-20/21) Loads setting conditions from a settings file (3166) [Copy Function] Copies to the clipboard : Each display can be copied to the clipboard [Print Function] Printing a displayed time series graph Printing a displayed summary Printing a harmonic display Printing the settings display Comment entry Printing support : Previews and prints the contents displayed on a timeseries graph : Previews and prints the contents displayed in a summary : Previews and prints the contents displayed in a harmonic spreadsheet : Previews and prints the contents displayed in the settings display : Text comments can be entered in any printout : Any color or monochrome printing supported by the operating system [Display Language] Language : English : Calculates the load factor and demand factor as a daily, weekly or monthly report, and displays the results : Specify up to four time ranges and totalize data for each time range independently DISTRIBUTED BY ASM GmbH HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@ hioki.co.jp Am Bleichbach 18 - 22 85452 Moosinning Tel.: 08123-986-0 Fax: 08123-986-500 HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: hioki@ hiokiusa.com All information correct as of Mar. 18, 2003. All specifications are subject to change without notice. 9625E1-33M Printed in Japan