CURRENT SENSING TRANSFORMER ACST-11, ACST-112 | | | | | | | | | | | | | | | FEATURES: • Precise Current Sensing OPTIONS: • T&R is standard • Custom design available STANDARD SPECIFICATIONS (Secondary Winding): Part No Lp mH ±25% DCR Ω ±20% N1 Turns ACST-11-20 ACST-11-30 ACST-11-40 ACST-11-50 ACST-11-60 ACST-11-70 ACST-11-100 ACST-11-125 ACST-11-200 0.30 0.66 1.20 2.00 3.00 3.90 7.50 12.0 29.0 1.40 2.10 2.80 3.50 4.20 4.90 7.00 8.75 14.0 20 30 40 50 60 70 100 125 200 APPLICATIONS: • SMPS • Current Sensing PHYSICAL CHARACTERISTICS: • Testing Condition: 10KHz 0.25VRMS (2-4) • Polarity: 2 and 11 are in phase • Turns Ratio Tolerance : ± 2% • Hipot: 500 VRMS ( 2-4 to 11-12 ) PHYSICAL CHARACTERISTICS: Part No Lp mH Min DCR Ω Max N1 Turns ACST-112-1 ACST-112-2 ACST-112-3 ACST-112-4 3.2 0.6 0.7 6.0 10 5 7 15 70 30 40 100 ABRACON IS ISO 9001 / QS 9000 CERTIFIED rev1.1-8/04 • Testing Condition: 1KHz 0.25VRMS (6-4) • Polarity: 6 and 8 are in phase • Turns Ratio Tolerance : ± 2% • Hipot: 100 VRMS ( 6-4 to 8-7 ) 30332 Esperanza, Rancho Santa Margarita, California 92688 tel 949-546-8000 | fax 949-546-8001 | www.abracon.com