MPSIND ADC111

ADC100 SERIES
1W, Miniature SIP, Single & Dual Output DC/DC Converters
Selection Guide
Model
Number
The ADC100 series is an excellent
selection for a variety of applications
including distributed power
systems, mixed analog/digital
subsystems, portable test
equipments, local power networks
and battery backed systems.
Mechanical Dimensions
2.54 [0.100]
2.1 [0.08]
18.5 [0.73]
1
2
4
5
Pin
1
2
4
5
6
6
0.5 [0.020]
Load
Regulation
% Max.
10
10
8
7
7
10
8
7
7
8
8
5
5
5
8
5
5
5
8
8
5
5
5
8
5
5
5
8
5
5
8
5
5
% Typ.
73
71
76
78
78
72
77
78
79
74
73
78
80
80
74
79
81
81
73
71
76
78
79
72
76
79
80
72
79
79
72
80
80
Singles
+Vin
-Vin
-Vout
No Pin
+Vout
Duals
+Vin
-Vin
-Vout
Common
+Vout
Case Size –
5V & 12V Input – 19.5x6.1x10.2mm
(0.77x0.24x0.40inch)
15V & 24V Input –19.5x7.1x10.2mm
(0.77x0.28x0.40inch)
Case Material –
Non-Conductive Black Plastic
Weight –
5V & 12V Input – 2.2g (0.08Oz)
15V & 24V Input– 2.6g (0.09Oz)
Tolerance
Millimeters
X.X±0.25
X.XX±0.13
Inches
X.XX±0.01
X.XXX±0.005
Pin
±0.05
±0.002
T= 6.1 (0.24) for 5V & 12V Input Models
T= 7.1 (0.28) for 15V & 24V Input Models
Efficiency
Pin Connections
19.5 [0.77]
T
The series consists of 33 models
with input voltages of 5V, 12V, 15V
and 24VDC which offers standard
output voltages of 3.3V, 5V, 9V, 12V,
15V, ±5V, ±9V, ±12V and ±15VDC
for a wide choice.
15
(13.5 – 16.5)
Output
Current
mA
260
200
110
84
67
±100
±56
±42
±34
260
200
110
84
67
±100
±56
±42
±34
260
200
110
84
67
±100
±56
±42
±34
200
84
67
±100
±42
±34
10.2 [0.40]
MPS Industries ADC100 1W
DC/DC's are specially designed
to provide the optimum cost/
benefit power solution in a
miniature SIP package.
24
(21.6 – 26.4)
3.2 [0.13]
•
•
•
12
(10.8 – 13.2)
1.3 [0.05]
•
Efficiency up to 81%
1000VDC Isolation
MTBF > 2,000,000 Hours
Low Cost
Input 5, 12, 15 and 24VDC
Output 3.3, 5, 9, 12, 15,
±5, ±9, ±12 and ±15VDC
Temperature Performance
-40°C to +85°C
UL 94V-0 Package Material
Internal SMD Construction
Industry Standard Pinout
5
(4.5 – 5.5)
0.5 [0.02]
•
•
•
•
•
•
ADC101
ADC102
ADC103
ADC104
ADC105
ADC106
ADC107
ADC108
ADC109
ADC111
ADC112
ADC113
ADC114
ADC115
ADC116
ADC117
ADC118
ADC119
ADC121
ADC122
ADC123
ADC124
ADC125
ADC126
ADC127
ADC128
ADC129
ADC151
ADC152
ADC153
ADC154
ADC155
ADC156
Output
Voltage
VDC
3.3
5
9
12
15
±5
±9
±12
±15
3.3
5
9
12
15
±5
±9
±12
±15
3.3
5
9
12
15
±5
±9
±12
±15
5
12
15
±5
±12
±15
0.25 [0.010]
Key Features
Input
Voltage
VDC
2463 208th Street, Ste. 205
Tel: (310) 533-1455
http://www.mpsind.com
Torrance, CA 90501
Fax: (310) 533-1853
E-mail: [email protected]
ADC100 SERIES
1W, Miniature SIP, Single & Dual Output DC/DC Converters
Absolute Maximum Ratings
Parameter
General Characteristics
Min.
Max. Units
Parameter
Isolation
Voltage
Isolation
Resistance
5VDC Input Models
-0.7
9
VDC
12VDC Input Models
-0.7
18
VDC
15VDC Input Models
-0.7
18
VDC
Isolation
Capacitance
24VDC Input Models
-0.7
30
VDC
Switching
Frequency
Lead Temperature
(1.5mm from case for 10sec.)
---
260
°C
Internal Power Dissipation
---
450
mW
Input Surge Voltage
(1000mS)
MTBF
Conditions
Min.
Typ.
Max.
Units
60 Seconds
1000
---
---
VDC
500VDC
1000
---
---
MΩ
100kHz, 1V
---
60
100
pF
70
100
120
kHz
2
---
---
MHrs
Min.
Typ.
Max.
Units
---
±1.2
±1.5
%
MIL-HDBK-217F
@25°C
Ground Benign
Exceeding the unit absolute maximum ratings could cause damage.
These are not continuous operating ratings.
Environmental Characteristics
Parameter
Operating
Temperature
Operating
Temperature
Storage
Temperature
Humidity
Output Characteristics
Conditions
Min.
Ambient
-40
85
°C
Line Regulation
Case
-40
90
°C
Load Regulation
-40
125
°C
Ripple & Noise
--95
Free-Air Convection
%
Short Circuit
Cooling
Max. Units
Parameter
Conditions
For Vin Change of
1%
Io = 20% to 100%
See Selection Guide
20MHz BW
---
50
75
%
mV P-P
0.5 Second Max.
Maximum Capacitive Load
Models by Output Voltage
(Each Output on Duals)
Derating Curve
100LFM
400LFM
200LFM
Output Power (%)
80
60
Natural
convection
20
0
¡ã
-40
50
Duals
Units
220
100
uF
Notes:
100
40
Singles
60
70
80
Ambient Temperature
90
100
110
1. Specifications typical at Ta=+25°C, resistive load, nominal input
voltage, rated output current unless otherwise noted.
2. These power converters require a minimum output load to maintain
specified regulation.
3. Operation under no-load conditions will not damage these modules;
however, they may not meet all specifications listed.
4. All DC/DC converters should be externally fused at the front end for
protection.
5. Other input and output voltage may be available, please contact
factory.
6. All specifications subject to change without notice.
7. For detailed data sheet, please visit our website.
]
2463 208th Street, Ste. 205
Tel: (310) 533-1455
http://www.mpsind.com
Torrance, CA 90501
Fax: (310) 533-1853
E-mail: [email protected]