ADC400 SERIES 1W, Ultra-High Isolation SIP, Single & Dual Output DC/DC Converters Selection Guide Model Number Input Voltage VDC Output Voltage VDC Output Current Efficiency mA % Typ. Load Regulation % Max. ADC401 5 200 66 10 ADC402 12 80 66 8 15 65 66 8 ±5 ±100 66 10 ADC405 ±12 ±40 72 8 ADC406 ±15 ±35 73 8 ADC411 5 200 66 10 ADC412 12 80 66 8 15 65 66 8 ±5 ±100 66 10 ADC415 ±12 ±40 74 8 ADC416 ±15 ±35 75 8 ADC403 5 (4.5 - 5.5) ADC404 The ADC400 series is an excellent selection for a variety of applications including distributed power systems, mixed analog/digital subsystems, portable test equipments, local power networks and battery backed systems. Pin Connections 22.0 [0.87] 2.54 [0.100] 3.5 [0.14] 12.5 [0.49] The series consists of 12 models with input voltages of 5V and 12VDC which offers standard output voltages of 5V, 12V, 15VDC in both single and dual output configurations. Mechanical Dimensions 3.5 [0.14] MPS Industries ADC400 1W DC/DC's are specially designed to provide ultra-high levels of isolation 6000VDC in a miniature SIP package. ADC414 21.0 [0.83] Pin Singles Duals 1 +Vin +Vin 2 -Vin -Vin 5 -Vout -Vout 6 No Pin Common 7 +Vout +Vout Case Size – 22.0x7.5x12.5mm (0.87x0.30x0.49inch) Case Material – 1 2 5 0.50 [0.020] 6 7.5 [0.30] • • • ADC413 0.5 [0.02] • Efficiency up to 75% 6000VDC Isolation MTBF > 2,000,000 Hours Low Cost Input 5 and 12VDC Output 5, 12, 15, ±5, ±12 and ±15VDC Temperature Performance -25°C to +70°C UL 94V-0 Package Material Internal SMD Construction Industry Standard Pin-out 7 2.0 [0.08] • • • • • • 12 (10.8 - 13.2) 0.25 [0.010] Key Features Non-Conductive Black Plastic Weight – 3.9g (0.14Oz) Tolerance Pin Millimeters Inches X.X±0.25 X.XX±0.01 X.XX±0.13 X.XXX±0.005 ±0.05 ±0.002 2463 208th Street, Ste. 205 Tel: (310) 533-1455 http://www.mpsind.com Torrance, CA 90501 Fax: (310) 533-1853 E-mail: [email protected] ADC400 SERIES 1W, Ultra-High Isolation SIP, Single & Dual Output DC/DC Converters Absolute Maximum Ratings Parameter General Characteristics Min. Max. Units 5VDC Input Models -0.7 9 VDC 12VDC Input Models -0.7 18 VDC Lead Temperature (1.5mm from case for 10sec.) --- 260 °C Internal Power Dissipation --- 650 mW Input Surge Voltage (1000mS) Isolation Voltage Isolation Resistance Isolation Capacitance MTBF Environmental Characteristics Min. Ambient -25 70 °C Line Regulation Case -25 90 °C Load Regulation -40 125 °C Ripple & Noise --95 Free-Air Convection % Short Circuit Cooling Min. Typ. Max. Units 60 Seconds 6000 --- --- VDC 500VDC 10 --- --- GΩ 100kHz, 1V --- 15 20 pF 50 80 100 kHz 2 --- --- MHrs Min. Typ. Max. Units --- ±1.2 ±1.5 % MIL-HDBK-217F @25°C Ground Benign Output Characteristics Conditions Operating Temperature Operating Temperature Storage Temperature Humidity Conditions Switching Frequency Exceeding the unit absolute maximum ratings could cause damage. These are not continuous operating ratings. Parameter Parameter Max. Units Parameter Conditions For Vin Change of 1% Io = 20% to 100% See Selection Guide 20MHz BW --- 100 150 % mV P-P 0.5 Second Max. Maximum Capacitive Load Models by Output Voltage (Each Output on Duals) Derating Curve 400LFM 100LFM Output Power (%) 200LFM 60 Natural convection 40 20 0 ¡ã -25 50 Duals Units 680 220 uF Notes: 100 80 Singles 60 70 80 Ambient Temperature 90 100 110 1. Specifications typical at Ta=+25°C, resistive load, nominal input voltage, rated output current unless otherwise noted. 2. These power converters require a minimum output load to maintain specified regulation. 3. Operation under no-load conditions will not damage these modules; however, they may not meet all specifications listed. 4. All DC/DC converters should be externally fused at the front end for protection. 5. Other input and output voltage may be available, please contact factory. 6. All specifications subject to change without notice. 7. For detailed data sheet, please visit our website. ] 2463 208th Street, Ste. 205 Tel: (310) 533-1455 http://www.mpsind.com Torrance, CA 90501 Fax: (310) 533-1853 E-mail: [email protected]