ALD120 1 2 0 W, S i n g l e O u tput, 2 Channel, Class 2 LED Drivers series Single Outputs Universal Input 8VDC to 48VDC Outputs Short Circuit Protection Full Safety Approvals for Class 2, Outdoor Wet Locations and LED Lighting Model Number I/P Voltage O/P Amps O/P Voltage Chan1/Chan2 Combined Current max. O/P Watts max. Ripple/Noise max. ALD120-208VFC ALD120-210VFC ALD120-212VFC ALD120-215VFC ALD120-218VFC ALD120-221VFC ALD120-224VFC ALD120-227VFC ALD120-236VFC ALD120-248VFC 8 VDC 10 VDC 12 VDC 15 VDC 18 VDC 21 VDC 24 VDC 27 VDC 36 VDC 48 VDC 10A 10A 10A 8A 6.67A 5.7A 5.0A 4.44A 3.33A 2.5A 90-264 VAC 90-264 VAC 90-264 VAC 90-264 VAC 90-264 VAC 90-264 VAC 90-264 VAC 90-264 VAC 90-264 VAC 90-264 VAC 5 / 5 5 / 5 5 / 5 5 / 5 5 / 5 4.57 / 4.57 4.0 / 4.0 3.55 / 3.55 2.66 / 2.66 2.0 / 2.0 80W 100W 120W 120W 120W 120W 120W 120W 120W 120W 80mV 100mV 120mV 150mV 180mV 210mV 240mV 270mV 360mV 480mV *Note: All noise measurements made at the output terminals, connected to a 20MHz low pass filter WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 1 2 0 W, S i n g l e O u tput, 2 Channel, Class 2 LED Drivers INPUT SPECIFICATIONS Input Voltage ALD120 Max. Iin Input Frequency Max. Inrush Current Power Factor ALD120 series ENVIRONMENTAL SPECIFICATIONS 90-264 VAC (120/240 VAC Nominal) 1.6A @ 100 VAC Input 47-63Hz 30A @ 230VAC Input 25°C, cold start-up 99%, typ. MTBF Cooling Operating Temp. Storage Temperature Relative Humidity 55K Hrs, FL @ 25°C ambient, Based on MIL-217F Convection -20°C to +60°C FL -40°C to +85°C 5% to 95% OUTPUT SPECIFICATIONS PHYSICAL SPECIFICATIONS Output Voltage/Current See Model Chart Output Voltage Adjust +10/-25% Max. Output Power See Model Chart Ripple / Noise See Model Chart Efficiency 80% min. @ FL, 230 VAC Input Hold Up Time 16mS @ FL, 100 VAC Input Start Up Time 1 Second, typ. Transient Response 4mS, FL to 1/2L, 100 VAC Input Line Regulation ±1% max. Voltage Mode Load Regulation ±5% max., (Voltage setting Adjust- able via on board pot +5/-25%) Over Current Protection 105% Max per channel (Hiccup- mode, Auto-Recovery upon removal of over current condition.* Constant Current Mode Regulation ±3% max., (Current setting Adjust- able via on board pot +5/-90%) Over Voltage Protection 132% max. * Short Circuit Protection Hiccup Mode, Auto Recovery upon removal of over current condition. * Case / Design / Material Mounting and Connection Size Weight * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. NEMA 3 Design / Aluminum / Potted with AC and DC Wiring Compartments Flange Mount, AC/DC Conduit Entries, Knockouts for 1/2” Conduit and Fittings 11”L x 3.37”W x 2.19”H 3.6 lb (1633g) Compliance / Safety EMI / RFI Safety Standards Weatherability Standard CISPR-22B, FCC-15B EMC EN61000-3-2 (EMC) UL/CUL 1310/1585, Class 2, Outdoor Wet Locations for UL 48 LED Lighting, CE EN60529 - Weatherability of an Enclosure - Rated to IP65 Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. All specifications are typical at nominal input, full load, and 25DegC unless otherwise noted WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060 1 2 0 W, S i n g l e O u tput, 2 Channel, Class 2 LED Drivers ALD120 series MECHANICAL DIMENSIONS WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 ASTRODYNE EUROPE: 353 51 561060