ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
0RCY-85T Series








RoHS Compliant
Isolated
High Efficiency
High Power Density
Fixed Frequency (300 kHz)
Low Cost
Input Under Voltage Lockout
Safety Approval to UL60950-1
(UL/cUL)
Pre-Bias Start Up








Rev.B
Output Over Voltage Shutdown
OCP/SCP
Over Temperature Protection
Remote On/Off
Output Voltage Trim
Positive/Negative Remote Sense
Basic Insulation
Pin Length (option)
Description
The 0RCY-85T Series are isolated dc/dc converters that operate from a nominal 48 Vdc source. These units
provide up to 100 W of output power. These units are designed to be highly efficient and cost-effective.
Features include remote on/off, short circuit protection, over current protection, over temperature protection, input
under voltage lockout, and output over voltage protection. These converters are provided in a compact, 1/8 brick
industry standard package.
Part Selection
Output
Voltage
12.0 V
Input Voltage
36 V - 75 V
Max. Output
Current
8.33 A
Max. Output
Power
100 W
Typical
Efficiency
91%
Model Number
Active High
0RCY-85T120
Model Number
Active Low
0RCY-85T12L
5.0 V
36 V - 75 V
20 A
100 W
91%
0RCY-85T050
0RCY-85T05L
3.3 V
36 V - 75 V
25 A
85 W
90%
0RCY-85T033
0RCY-85T03L
2.5 V
36 V - 75 V
25 A
62.5 W
89%
0RCY-85T025
0RCY-85T02L
1.8 V
36 V - 75 V
25 A
45 W
88%
0RCY-85TV80
0RCY-85TV8L
1.5 V
36 V - 75 V
30 A
45 W
86%
0RCY-85TV50
0RCY-85TV5L
1.2 V
36 V - 75 V
30 A
36 W
84%
0RCY-85TV20
0RCY-85TV2L
Notes: 1.Change the last character to “M” to indicate 0.18’’ pin length and active low.
2. Add “G” suffix at the end of the model number to indicate Tray Packaging.
3. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
-0.3 V
-
80 V
-
-
100 V
-0.3 V
-
18 V
-
-
2000 V
Ambient Temperature
-40 C
-
100 C
Storage Temperature
-55 C
-
125 C
Input Voltage (continuous)
Input Voltage Transient Protection
Remote On/Off
I/O Isolation Voltage
Notes
Operating for 100mS
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Input Specifications
Parameter
Min
Typ
Max
36 V
48 V
75 V
Vo=12.0 V
Vo=5.0 V
Vo=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
-
-
3.2 A
3.2 A
2.8 A
2.2 A
1.7 A
1.7 A
1.5 A
Vo=12.0 V
Vo=5.0 V
Vo=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
-
65 mA
65 mA
60 mA
55 mA
50 mA
40 mA
35 mA
6 mA
90 mA
90 mA
80 mA
75 mA
70 mA
60 mA
50 mA
12 mA
Input Reflected Ripple Current (pk-pk)
-
12 mA
24 mA
Input Reflected Ripple Current (rms)
-
2 mA
4 mA
I t Inrush Current Transient
-
0.01 A s
0.02 A s
Turn-on Voltage Threshold
32 V
34 V
35 V
Turn-off Voltage Threshold
30 V
32 V
33 V
Input Voltage
Notes
Input Current (full load)
Input Current (no load)
Remote Off Input Current
2
2
Tested with simulated source
impedance of 10 uH, 5 Hz to 20 MHz;
use a 100 uF/100 V electrolytic
capacitor with ESR = 1 ohm max. at
200 kHz at 25 C.
2
Output Specifications
Parameter
Output Voltage Set Point
Min
Typ
Max
11.760 V
4.925 V
3.250 V
2.463 V
1.773 V
1.477 V
1.182 V
12.0 V
5.0 V
3.3 V
2.5 V
1.8 V
1.5 V
1.2 V
12.24 V
5.075 V
3.350 V
2.538 V
1.827 V
1.523 V
1.218 V
VO=12.0 V-3.3 V
VO=1.2 V-2.5 V
-
2 mV
1 mV
5 mV
3 mV
Vo=12.0 V
Vo=5.0 V
Vo=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
-
8 mV
8 mV
6 mV
4 mV
3 mV
3 mV
2 mV
16 mV
16 mV
12 mV
8 mV
6 mV
6 mV
4 mV
Vo=12.0 V
Vo=5.0 V
Vo=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
Line Regulation
Load Regulation
Notes
Vin=48 V, Io=50% full load,
Ta=25 C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Output Specifications (continued)
Parameter
Regulation Over Temperature
(-40 C to +85 C)
Min
Typ
Max
Vo=12.0 V
Vo=5.0 V
Vo=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
-
50 mV
50 mV
20 mV
15 mV
15 mV
10 mV
10 mV
75 mV
75 mV
40 mV
30 mV
30 mV
20 mV
20 mV
Vo=12.0 V
Vo=5.0 V
Vo=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
0A
0A
0A
0A
0A
0A
0A
-
8.33 A
20 A
25 A
25 A
25 A
30 A
30 A
Vo=12.0 V
Vo=5.0 V
Vo=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
10 A
23 A
30 A
27 A
27 A
32 A
32 A
-
13 A
29 A
36 A
33 A
33 A
36 A
36 A
2
3A s
16 A
35 A
42 A
40 A
40 A
45 A
45 A
2
5A s
VO=12.0 V
VO=5.0 V
VO=1.2 V-3.3 V
-
30 mV
25 mV
15 mV
50 mV
50 mV
30 mV
VO=12.0 V
VO=5.0 V
VO=3.3 V
VO=1.2 V-2.5 V
-
100 mV
80 mV
45 mV
40 mV
0%
150 mV
120 mV
90 mV
80 mV
30 mS
5%
VO=12.0 V
VO=5.0 V
VO=1.2 V- 3.3 V
0 uF
0 uF
0 uF
-
1000 uF
10000 uF
20000 uF
Notes
Output Current
Current Limit Threshold
Short Circuit Surge Transient
Ripple and Noise (rms)
Ripple and Noise (pk-pk)
Turn on Time
Overshoot at Turn on
Output Capacitance
Transient Response
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
VO=12.0 V
VO=5.0 V
VO=3.3 V
-
300 mV
200 uS
300 mV
200 uS
200 mV
200 uS
200 mV
200 uS
150 mV
200 uS
150 mV
200 uS
400 mV
300 uS
400 mV
300 uS
300 mV
300 uS
300 mV
300 uS
200 mV
300 uS
200 mV
300 uS
Test conditions:
0-20 MHz BW, with a 1 uF
ceramic capacitor and a
10 uF Tantalum capacitor
at the output.
Test conditions: di/dt =
0.1 A/uS, Vin=48 V,
with a 1 uF ceramic
capacitor and a 10 uF
Tantalum capacitor at
the output.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Output Specifications (continued)
Parameter
Transient Response
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Min
VO=2.5 V
VO=1.8 V
VO=1.5 V
VO=1.2 V
-
Typ
150 mV
150 uS
150 mV
150 uS
140 mV
150 uS
140 mV
150 uS
130 mV
150 uS
130 mV
150 uS
120 mV
150 uS
120 mV
150 uS
Max
200 mV
200 uS
200 mV
200 uS
170 mV
200 uS
170 mV
200 uS
150 mV
200 uS
150 mV
200 uS
140 mV
200 uS
140 mV
200 uS
Notes
Test conditions: di/dt =
0.1 A/uS, Vin=48 V, with
a 1 uF ceramic capacitor
and a 10 uF Tantalum
capacitor at the output.
Note: All specifications are typical at 25 C unless otherwise stated.
General Specifications
Parameter
Min
Typ
Max
88%
88%
87%
86%
85%
83%
81%
270 kHz
-
91%
91%
90%
89%
88%
86%
84%
300 kHz
1500 pF
330 kHz
-
80% Vo
90% Vo
-
125 C
130% Vo
110% Vo
110% Vo
10%
-
-
-
4.0 V
1.4 V
2.0 V
1.4 V
1.2 V
0.9 V
Notes
Efficiency
VO=12.0 V
VO=5.0 V
VO=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
Switching Frequency
Isolation capacitance
Output Voltage Trim Range
VO=1.5 V-12 V
VO=1.2 V
Remote Sense
Over Temperature Protection
Over Voltage Protection
Pre-bias Voltage
VO=5.0 V
VO=3.3 V
Vo=2.5 V
Vo=1.8 V
Vo=1.5 V
Vo=1.2 V
MTBF
Vin=48V, Io=Io, max
The total voltage increased by trim and
remote sense should not exceed
10%Vo.
Vin=48V, full load, in hiccup mode.
Calculated Per Bell Core SR-332
(Vin=48 V, Vo=3.3 V, Io=20 A, Ta = 25
C)
1,583,176 hours
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Weight
2.30 x 0.896 x 0.395
58.42 x 22.76 x 10.03
-
27 g
-
Note: All specifications are typical at 25 C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Control Specifications
Parameter
Min
Typ
Max
-0.3 V
-
0.8 V
2.4 V
-
18 V
-0.3 V
-
0.8 V
Signal High (Unit On)
2.4 V
-
18 V
Current Sink
0 mA
-
0.75 mA
Notes
Remote On/Off
Signal Low (Unit On)
Active Low
Signal High (Unit Off)
Signal Low (Unit Off)
Active High
0RCY-85TxxL. The remote
on/off pin open, Unit off.
0RCY-85Txx0. The remote
on/off pin open, Unit on.
Output Trim Equations
Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected
between the Trim pin and Ground pin. The Trim Up resistor should be connected between the Trim pin and the
Vout. Only one of the resistors should be used for any given application.
511
Rtrim  down 
 10.22k
delta
Vout
Module
Trim
Rtrim-down
Vo=1.5 V-12 V:
Rtrim  up 
GND
(100  delta ) Vo  5.11  626
 10.22k
1.225  delta
Vout
Rtrim-up
Module
Vo=1.2 V:
Rtrim  up 
Notes:
delta 
(100  delta )  Vo  5.11  313
 10.22k
0.6125  delta
Trim
GND
Vo _ req  Vo   100 % 
Vo
Vo_req=Desired (trimmed) output voltage [V]
Output voltage Vo=1.202 V for 1.2 V output; Vo=1.503 V for 1.5 V output; Vo=1.804 V for 1.8 V; Vo=2.505 V for
2.5 V output; Vo=3.308 V for 3.3 V output; Vo=5.000 V for 5.0 V; Vo=12.000 V for 12 V output
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Efficiency Data
0RCY-85T05x EFFICIENCY CURVE
0RCY-85T12x EFFICIENCY CURVE
94%
94%
90%
36V
48V
75V
86%
EFFICIENCY
EFFICIENCY
90%
82%
78%
74%
36V
48V
75V
86%
82%
78%
74%
70%
70%
1.60
3.20
4.80
6.00
7.20
8.33
4
8
OUTPUT CURRENT (A)
0RCY-85T03x EFFICIENCY CURVE
16
20
0RCY-85T02x EFFICIENCY CURVE
90%
90%
36V
48V
75V
82%
86%
EFFICIENCY
86%
EFFICIENCY
12
OUTPUT CURRENT (A)
78%
36V
48V
75V
82%
78%
74%
74%
70%
70%
5
10
15
20
5
25
10
15
20
25
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
0RCY-85TV5x EFFICIENCY CURVE
0RCY-85TV8x EFFICIENCY CURVE
88%
88%
84%
36V
48V
75V
80%
76%
EFFICIENCY
EFFICIENCY
84%
72%
76%
72%
68%
68%
64%
64%
60%
36V
48V
75V
80%
60%
5
10
15
20
25
6
12
OUTPUT CURRENT (A)
18
24
30
OUTPUT CURRENT (A)
0RCY-85TV2x EFFICIENCY CURVE
88%
84%
36V
48V
75V
EFFICIENCY
80%
76%
72%
68%
64%
60%
6
12
18
24
30
OUTPUT CURRENT (A)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Thermal Derating Curves
Vin=48V, with maximum junction temperature of semiconductors derated to 120 degree C.
0RCY-85T12x
0RCY-85T05x
0RCY-85T02x
0RCY-85T03x
0RCY-85TV8x
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Thermal Derating Curves (continued)
0RCY-85TV5x
0RCY-85TV2x
Thermal Reference
Note: TH1 and TH2 are hot spots which should not exceed 118 degree C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Ripple and Noise Waveforms
Ripple and noise at max load 12 Vdc/8.33 A output
Ripple and noise at max load 5.0 Vdc/20 A output
Ripple and noise at max load 3.3 Vdc/25 A output
Ripple and noise at max load 2.5 Vdc/25 A output
Ripple and noise at max load 1.8 Vdc/25 A output
Ripple and noise at max load 1.5 Vdc/30 A output
.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Ripple and Noise Waveforms (continued)
Ripple and noise at max load 1.2 Vdc/30 A output
Note: Ripple and Noise at 48 V input, with a 1 uF ceramic capacitor and a 10 uF tantalum capacitor at the output,
and Ta=25 deg C
Transient Response Waveforms
Transients 50% to 25% load 12 Vdc output
Transients 25% to 50% load 12 Vdc output
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Transient Response Waveforms (continued)
Transients 50% to 25% load 5.0 Vdc output
Transients 25% to 50% load 5.0 Vdc output
Transients 50% to 25% load 3.3 Vdc output
Transients 25% to 50% load 3.3 Vdc output
Transients 50% to 25% load 2.5 Vdc output
Transients 25% to 50% load 2.5 Vdc output
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Converter
Transient Response Waveforms (continued)
Transients 50% to 25% load 1.8 Vdc output
Transients 25% to 50% load 1.8 Vdc output
Transients 50% to 25% load 1.5 Vdc output
Transients 25% to 50% load 1.5 Vdc output
Transients 50% to 25% load 1.2 Vdc output
Transients 25% to 50% load 1.2 Vdc output
Note: Transient response at 48 V input, di/dt=0.1 A/uS, with external 10 uF tantalum cap and 1 uF ceramic cap
at the output, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302  Tel 201-432-0463  Fax 201-432-9542  www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input 1.2 Vdc - 12 Vdc / 8.33 A - 30 A Output, 1/8 Brick
Mechanical Outline
Pin Connections
Pin
Function
Pin Dia
1
Vin+
0.040’’
2
Remote On/Off
0.040’’
3
Vin-
0.040’’
4
Vout-
0.062’’
5
Sense-
0.040’’
6
Trim
0.040’’
7
Sense+
0.040’’
8
Vout+
0.062’’
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
2009 Bel Fuse Inc. Specifications subject to change without notice. 052609
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com