BEL XRSB

ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
xRSB-40U Series
RoHS Compliant
Rev.A
•
Isolated
•
Input Under Voltage Lockout
•
Fixed Frequency
•
Output Over Voltage Shutdown
•
High Efficiency
•
OCP/SCP
•
High Power Density
•
Over Temperature Protection
•
Low Cost
•
Wide Input Voltage
•
Output Voltage Trim
•
Positive/Negative Remote Sense
•
Basic Insulation
•
Through Hole and SMT(Option)
•
Remote On/Off Logic (Option)
•
Input Over Voltage Protection
Description
The xRSB-40U series are isolated dc/dc converters that operate from a nominal 24 Vdc or 48 Vdc source. These
units will provide up to 40 W of output power from an 18 Vdc - 75 Vdc wide input range. These units are designed
to be highly efficient and low cost. Features include remote on/off, over current protection and under voltage
lockout. These converters are provided in an industry standard sixteenth brick package.
Part Selection
Output
Voltage
1.2 Vdc
1.5 Vdc
1.8 Vdc
2.5 Vdc
3.3 Vdc
5.0 Vdc
12 Vdc
Input Voltage
18 Vdc - 75 Vdc
18 Vdc - 75 Vdc
18 Vdc - 75 Vdc
18 Vdc - 75 Vdc
18 Vdc - 75 Vdc
18 Vdc - 75 Vdc
18 Vdc - 75 Vdc
Max. Output
Current
18 A
16 A
14 A
12 A
10 A
8A
3.5 A
Max. Output
Power
22 W
24 W
25 W
30 W
33 W
40 W
42 W
Typical
Efficiency
82%
84%
85%
86%
87.5%
87%
85%
Model Number
Active Low
xRSB-40UV2L
xRSB-40UV5L
xRSB-40UV8L
xRSB-40U02L
xRSB-40U03L
xRSB-40U05L
xRSB-40U12L
Model Number
Active High
xRSB-40UV20
xRSB-40UV50
xRSB-40UV80
xRSB-40U025
xRSB-40U033
xRSB-40U050
xRSB-40U120
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging. Replace”x” with “S” to
indicate SMT package, or “0” to indicate through hole package.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Input Voltage (continuous)
Remote On/Off
I/O Isolation Voltage
Ambient Temperature
Storage Temperature
Min
-0.3 V
-0.3 V
-
Max
80 V
18 V
1500 V
-40 °C
-55 °C
Typ
-
Min
18 V
Typ
48 V
Max
75 V
-
-
2.5 A
3.0 A
3.5 A
Notes
85 °C
125 °C
Input Specifications
Parameter
Input Voltage
Input Current (full load)
Vo=1.2 V - 1.8 V
Vo=2.5 V - 3.3 V
Vo=5.0 V - 12 V
Notes
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Input Specifications (continued)
Parameter
Input Current (no load)
Min
-
Typ
60 mA
Max
120 mA
Remote Off Input Current
-
1 mA
3 mA
Input Reflected Ripple Current (pk-pk)
-
20 mA
50 mA
Input Reflected Ripple Current (rms)
-
3 mA
7 mA
I2t Inrush Current Transient
-
0.01 A2s
0.02 A2s
Turn On Voltage Threshold
16.6 V
17.2 V
17.8 V
Turn Off Voltage Threshold
16.2 V
16.8 V
17.4 V
Notes
Tested with simulated source impedance of
15 uH, 5 Hz to 20 MHz; use a 100 uF/100 V
electrolytic capacitor with ESR=1 ohm max
at 200 kHz at the input.
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
Output Specifications
Parameter
Output Voltage Set Point
Min
Typ
Max
1.182 V
1.478 V
1.773 V
2.463 V
3.250 V
4.925 V
11.750 V
1.2 V
1.5 V
1.8 V
2.5 V
3.3 V
5.0 V
12 V
1.218 V
1.523 V
1.827 V
2.538 V
3.350 V
5.075 V
12.250 V
Vo=1.2 V - 1.8 V
Vo=2.5 V
Vo=3.3 V
Vo=5.0 V
Vo=12 V
-
±0.5 mV
±1.0 mV
±3.0 mV
±4.0 mV
±6.0 mV
±3 mV
±4 mV
±8 mV
±9 mV
±15 mV
Vo=1.2 - 2.5 V
Vo=3.3 - 5.0 V
Vo=12 V
-
±3 mV
±4 mV
±9 mV
±5 mV
±9 mV
±18 mV
Regulation Over Temperature(-40 °C to +85 °C)
Vo=1.2 V
Vo=1.5 - 1.8 V
Vo=2.5 - 3.3 V
Vo=5.0 V
Vo=12 V
-
±4 mV
±6 mV
±9 mV
±15 mV
±20 mV
±9 mV
±14 mV
±16 mV
±30 mV
±35 mV
0A
0A
0A
0A
0A
0A
0A
-
18 A
16 A
14 A
12 A
10 A
8A
3.5 A
-
0.5 A s
Vo=1.2 V
Vo=1.5 V
Vo=1.8 V
Vo=2.5 V
Vo=3.3 V
Vo=5.0 V
Vo=12 V
Line Regulation
Load Regulation
Output Current
Vo=1.2 V
Vo=1.5 V
Vo=1.8 V
Vo=2.5 V
Vo=3.3 V
Vo=5.0 V
Vo=12 V
Short Circuit Surge Transient
2
Notes
Test conditions:
Vin=48 V; Io=50%
load
2
1A s
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Output Specifications (continued)
Parameter
Current Limit Threshold
Min
Typ
Max
21 A
19 A
17 A
14 A
11 A
8.8 A
4.2 A
25 A
22 A
20 A
17 A
14 A
10 A
5A
29 A
26 A
23 A
20 A
16 A
12.5 A
6A
Vo=1.2 V - 1.8 V
Vo=2.5 V
Vo=3.3 V
Vo=5.0 V
Vo=12 V
-
6 mV
10 mV
12 mV
25 mV
30 mV
12 mV
20 mV
25 mV
50 mV
55 mV
Vo=1.2 V - 1.8 V
Vo=2.5 V
Vo=3.3 V
Vo=5.0 V
Vo=12 V
Turn on Time
-
40 mV
45 mV
55 mV
70 mV
90 mV
25 mS
70 mV
80 mV
90 mV
120 mV
180 mV
50 mS
Overshoot at Turn on
-
0%
5%
470 uF
470 uF
470 uF
470 uF
330 uF
150 uF
10 uF
-
15000 uF
10000 uF
10000 uF
5600 uF
4700 uF
2200 uF
220 uF
Vo=1.2 V
Vo=1.5 V
Vo=1.8 V
Vo=2.5 V
Vo=3.3 V
Vo=5.0 V
Vo=12 V
Notes
Ripple and Noise (rms)
Ripple and Noise (pk-pk)
Output Capacitance
Vo=1.2 V
Vo=1.5 V
Vo=1.8 V
Vo=2.5 V
Vo=3.3 V
Vo=5.0 V
Vo=12 V
Transient Response
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Overshoot
25% ~ 50%
Max Load
Settling Time
Overshoot
50% ~ 25%
Max Load
Settling Time
Vo=1.2 V
Vo=1.5 -1.8 V
Vo=2.5 -3.3 V
Vo=5.0 V
Vo=12 V
-
60 mV
80 uS
60 mV
80 uS
60 mV
80 uS
60 mV
80 uS
180 mV
80 uS
180 mV
80 uS
250 mV
100 uS
250 mV
100 uS
400 mV
150 uS
400 mV
150 uS
110 mV
150 uS
110 mV
150 uS
110 mV
150 uS
110 mV
150 uS
250 mV
150 uS
250 mV
150 uS
350 mV
200 uS
350 mV
200 uS
650 mV
300 uS
650 mV
300 uS
Tested at 0-20 MHz
BW, with a 1 uF
ceramic capacitor and
a 10 uF Tantalum
capacitor at the
output.
Recommend to use
AVX TPS series
Tantalum capacitor as
min capacitor.
Test conditions: di/dt
= 0.1 A/uS, Vin=48 V,
with a 1 uF ceramic
capacioor and a Min
Capacitance of
Tantalum capacitor at
the output
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
General Specifications
Parameter
Min
Typ
Max
78%
79%
81%
83%
85%
85%
83%
82%
84%
85%
86%
87.5%
87%
85%
-
450 kHz
500 kHz
500 kHz
550 kHz
550 kHz
600 kHz
Isolation Capacitance
-
3900 pF
-
Over Temperature Protection
-
125 °C
-
90% Vo
-
110% Vo
-
130% Vo
160% Vo
Notes
Efficiency
Vo=1.2 V
Vo=1.5 V
Vo=1.8 V
Vo=2.5 V
Vo=3.3 V
Vo=5.0 V
Vo=12 V
Switching Frequency
Vo=1.2 V -12 V
Vo=1.8 V
Output Voltage Trim Range
Over Voltage Protection
MTBF
TBD
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Weight
Vin=48 V, full load
Test conditions: Vin=48 V, full load and
short the feedback optocoupler.
Calculated Per Bell Core SR-332 (IO =
Nominal; Ta = 25 °C)
1.3 x 0.9 x 0.446
33.0 x 22.9 x 11.34
SRSB-40Uxxx
1.3 x 0.9 x 0.460
33.0 x 22.9 x 11.39
0RSB-40Uxxx
-
14 g
-
Note: All specifications are typical at 25 °C unless otherwise stated.
Control Specifications
Parameter
Min
Typ
Max
-0.3 V
-
0.8 V
2.4 V
-
18 V
-0.3 V
-
0.8 V
2.4 V
-
18 V
0 mA
-
1 mA
Notes
Remote On/Off
Signal Low (Unit On)
Active Low
Signal High (Unit Off)
Signal Low (Unit Off)
Active High
Signal High (Unit On)
Current Sink
-
When Remote On/Off pin is
open, for active low option, unit
is off; for active high option, unit
is on
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Output Trim Equations
Equations for calculating the trim resistor are shown below (Unit: kΩ). The Trim Down resistor should be
connected between the Trim pin and Ground pin. The Trim Up resistor should be connected between the Trim pin
and the Vout. Only one of the resistors should be used for any given application.
1) Trim Equations for Vo=1.2 V
Vo
Rtrimdown =
511
− 10.22
delta
Module
Trim
Rtrimdown
Rtrimup =
(100 + delta ) ⋅ Vo ⋅ 5.11 − 313
− 10.22
0.6125 ⋅ delta
Note:
delta =
GND
(Vo _ req − Vo ) × 100[% ]
Vo
Vo
Rtrimup
Module
Vo_req=Desired (trimmed) output voltage [V]
Trim
Vo=1.202 V
GND
2) Trim Equations for Vo=1.5 V - 12 V
Rtrimdown =
Rtrimup =
Note:
511
− 10.22
delta
(100 + delta ) ⋅Vo ⋅ 511 − 626
− 10.22
1.225 ⋅ delta
delta =
(Vo _ req − Vo ) × 100 [% ]
Vo
Vo_req=Desired (trimmed) output voltage [V]
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Efficiency Data
90%
90%
85%
80%
18V
24V
48V
75V
75%
70%
65%
EFFICIENCY
EFFICIENCY
85%
80%
70%
65%
60%
60%
55%
55%
50%
50%
1.80
4.50
9.00
13.50
1.00
18.00
xRSB-40UV2x
5.00
7.50
10.00
xRSB-40U03x
90%
90%
85%
85%
80%
18V
24V
48V
75V
75%
70%
65%
EFFICIENCY
80%
70%
65%
60%
55%
55%
50%
18V
24V
48V
75V
75%
60%
0.80
2.50
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
EFFICIENCY
18V
24V
48V
75V
75%
50%
2.00
4.00
6.00
OUTPUT CURRENT (A)
xRSB-40U05x
8.00
0.35
0.88
1.75
2.63
3.50
OUTPUT CURRENT (A)
xRSB-40U12x
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Thermal Derating Curves
Vin=48 Vdc
xRSB-40UV2x
xRSB-40U03x
xRSB-40U05x
xRSB-40U12x
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Thermal Derating Curves (continued)
Vin=24 Vdc
xRSB-40UV2x
xRSB-40U05x
xRSB-40U03x
xRSB-40U12x
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Ripple and Noise Waveforms
48 Vdc input, 1.2 Vdc output
48 Vdc input, 3.3 Vdc output
48 Vdc input, 5.0 Vdc output
48 Vdc input, 12 Vdc output
Note: Ripple and noise at full load, with a 1 uF ceramic capacioor and a Min Capacitance of Tantalum capacitor at
the output, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Transient Response Waveforms
Vout=1.2 V 50% to 25% Load Transients
Vout=1.2 V 25% to 50% Load Transients
Vout=3.3 V 50% to 25% Load Transients
Vout=3.3 V 25% to 50% Load Transients
Vout=5.0 V 50% to 25% Load Transients
Vout=5.0 V 25% to 50% Load Transients
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Transient Response Waveforms (continued)
Vout=12 V 50% to 25% Load Transients
Vout=12 V 25% to 50% Load Transients
Note: Transient Response at Vin=48 V, di/dt=0.1 A/uS, with a 1 uF ceramic capacioor and a Min Capacitance of
Tantalum capacitor at the output, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
SMT Package (SRSB-40Uxxx)
Pin Connections
Pin
Function
1
Vin (+)
2
Remote On/Off
3
Vin (-)
4
Vout (-)
5
Remote Sense (-)
6
Trim
7
Remote Sense (+)
8
Vout (+)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
24 Vdc/48 Vdc Input 1.2 Vdc - 12 Vdc / 18 A - 3.5 A Outputs, 1/16 Brick
Through Hole Package (0RSB-40Uxxx)
Pin Connections
Pin
1
2
3
4
5
6
7
8
Function
Vin (+)
Remote On/Off
Vin (-)
Vout (-)
Remote Sense (-)
Trim
Remote Sense (+)
Vout (+)
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2007 Bel Fuse Inc. Specifications subject to change without notice. 012907
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com