AME30 Series 30 watt encapsulated ac-dc converter • SWITCHING POWER MODULES FOR PCB MOUNTING • FULLY ENCAPSULATED PLASTIC CASE • UNIVERSAL INPUT RANGE 90 ... 260 VAC, 47 ... 440 Hz • REGULATED OUTPUT • LOW RIPPLE & NOISE • HIGH EFFICIENCY • CE, cUL APPROVALS AC-DC CONVERTERS ELECTRICAL SPECIFICATIONS 102 All specifications valid at nominal Input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. (Single Output) AME30-3.3S AME30-5S AME30-12S AME30-15S AME30-24S Max output wattage (W) 20W 30W 30W 30W 30W Voltage 90 ... 260 VAC or 120 ... 370 VDC Frequency (Hz) 47 ... 440 Hz Current (Full Load) 520mA max. (115 VAC) / 320mA max. (230 VAC) Input Inrush Current (<2ms) 10 A max. (115 VAC) / 20 A max. (230VAC) Leakage Current 0.75mA max. External Fuse (recommended) 1.5 A slow blow type Voltage (VDC) 3.3V 5V 12V 15V 24V Voltage Accuracy ±2% Current (mA) max. 6000 6000 2500 2000 1250 Line Regulation (typ.) ±1% Load Regulation (typ.) ±1% Output Minimum Load 5% 4% 2% 2% 2% Maximum Capacitive Load 470-23,000m F depending on model Noise <0.5% Vout +50mV max (Vp-p) Ripple <0.2% Vout +40mV max (Vp-p) Efficiency 73% 80% 84% 84% 84% Hold-up Time 15 ms min. Switching Frequency 100 kHz Over Current Protection Hiccup technique, auto-recovery Protection Over Voltage Protection Zener diode clamp Short Circuit Protection Hiccup mode, indefinite (automatic recovery) Isolation Input-Output (VAC) 3000V Operating Temperature -25°C ... +71°C Storage Temperature -40°C ... +85°C Environment Temperature Coefficient 0.02% / °C Humidity 95% RH MTBF >190,000 h @ 25°C (MIL-HDBK-217F) Dimension (L x W x H) 3.5 x 2.5 x 0.98 inches (89.0 x 63.5 x 25.0 mm) Case Material Plastic resin + Fiberglass (flammability to UL 94V-0) Physical Weight 220g Cooling Method Free air convection Safety Agency Approvals cUL, CE EMI (Conducted & Radiated Emission) EN 55022 class B EMC EMS (Noise Immunity) EN 55024 Specifications are subject to change without notification TO ORDER CALL 1-888-9-AIMTEC AME30 Series 30 watt encapsulated ac-dc converter All specifications valid at nominal Input voltage, full load and +25°C after warm-up time unless otherwise stated. Model No. (Dual & Triple Output) AME30-5D AME30-12D AME30-15D AME30-5S12S AME30-512T AME30-515T Max output wattage (W) 30W 30W 30W 30W 30W 30W Voltage 90 ... 260 VAC or 120 ... 370 VDC Frequency (Hz) 47 ... 440 Hz Current (Full Load) 520mA max. (115 VAC) / 320mA max. (230 VAC) Input Inrush Current (<2ms) 10 A max. (115 VAC) / 20 A max. (230VAC) Leakage Current 0.75mA max. External Fuse (recommended) 1.5 A slow blow type Voltage (VDC) ±5V ±12V ±15V 5/12V 5/±12V 5/±15V Voltage Accuracy ±2% Current (mA) max. ±3000 ±1250 ±1000 3000/1250 3000/±630 3000/±500 Line Regulation (typ.) ±1% ±1% ±1% ±1%/±5% ±1%/±5% ±1%/±5% Load Regulation (typ.) ±3% ±3% ±3% ±3%/±6% ±2%/±6% ±2%/±6% Output Minimum Load 2% 3% 1% 20% 20% 20% Maximum Capacitive Load 470-23,000m F depending on model Noise <0.5% Vout +50mV max (Vp-p) Ripple <0.2% Vout +40mV max (Vp-p) Efficiency 80% 84% 84% 80% 80% 80% Hold-up Time 15 ms min. Switching Frequency 100 kHz Over Current Protection Hiccup technique, auto-recovery Protection Over Voltage Protection Zener diode clamp Short Circuit Protection Hiccup mode, indefinite (automatic recovery) Isolation Input-Output (VAC) 3000V Operating Temperature -25°C ... +71°C Storage Temperature -40°C ... +85°C Environment Temperature Coefficient 0.02% / °C Humidity 95% RH MTBF >190,000 h @ 25°C (MIL-HDBK-217F) Dimension (L x W x H) 3.5 x 2.5 x 0.98 inches (89.0 x 63.5 x 25.0 mm) Case Material Plastic resin + Fiberglass (flammability to UL 94V-0) Physical Weight 220g Cooling Method Free air convection Safety Agency Approvals cUL, CE EMI (Conducted & Radiated Emission) EN 55022 class B EMC EMS (Noise Immunity) EN 55024 Specifications are subject to change without notification Note: 1. The triple output required a minimum 20% loading on the ouput to maintain specified regulation. Operation under no-load condition will not damage these devices, however they may not meet all listed specifications. 2. Load regulation for triple output: Main output (V1): 20% to 100% with 20% to 100% balanced on auxiliaries. Auxiliary outputs (V2 abd V3): 20% to 100% balanced on all outputs. 3. Cross regulation for triple output: Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%. Auxiliary outputs (V2 and V3): Main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other auxiliary 25% to 100% Continued on next page VISIT US AT WWW.AIMTEC.CA AC-DC CONVERTERS ELECTRICAL SPECIFICATIONS 103 AME30 Series OUTLINE DIMENSIONS & PIN CONNECTIONS MECHANICAL DIMENSION (Top View) Pin 1 2 3 4 5 6 7 Dual 5S / 12S Triple DERATING AC-DC CONVERTERS BLOCK DIAGRAM Single AC Input (N) AC Input (N) AC Input (N) AC Input (N) AC Input (L) AC Input (L) AC Input (L) AC Input (L) +V Output +V Output +12V +V2 Output No pin No pin +5V +5V -V Output Common +12 RTN V2, V3 common +5 RTN No pin No pin +5 RTN -V3 Ouput No connect -V Output No pin 104 TO ORDER CALL 1-888-9-AIMTEC