VER : D_1 update : 2012.03.14 AC-DC Power Module ANC A-E1 SERIES 15 Watts KEY FEATURES Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Output Low Ripple and Noise Screw Terminal For Optional CE, UL, TUV Approval 3-Years Product Warranty ELECTRICAL SPECIFICATIONS Model No. ( Single Output ) ANC-5S 15W Max Output Wattage (W) Voltage Output Protection Isolation Environment Physical ANC-12S 15W A-E1 ANC-15S 15W A-E1 ANC-24S 15W A-E1 90-264 VAC or 120-370 VDC Frequency (Hz) Input A-E1 47-440 Hz Current (Full load) 310 mA max. (115 VAC) / 170 mA max. (230 VAC) Inrush Current (<2ms) 23 A max. (115 VAC) / 46 A max. (230 VAC) Leakage Current 0.75 mA max. External Fuse (recommend) 1.5 A slow blow type Voltage (V.DC.) 5V Voltage Accuracy ±2% Current (mA) max 3000 Line Regulation (LL-HL) (typ.) ±0.5% Load Regulation (5-100%) (typ.) ±0.5% Minimum Load 12V 15V 24V 1250 1000 625 4% 2% 0% 0% Maximum Capacitive Load 31000 uF 4500 uF 2700 uF 900 uF Ripple <0.2% Vout +40mV max (Vp-p) Noise <0.5% Vout +50mV max (Vp-p) Efficiency 74% 78% 80% Hold-up Time 15 ms min. Switching Frequency 100 kHz 79% Over Power Protection Hiccup technique, auto-recovery Over Voltage Protection Zener diode clamp Short Circuit Protection Hiccup mode, indefinite (automatic recovery) Input-Output (V.AC) 3000V Input-FG (V.AC) 1500V Output-FG (V.AC) 500V Operating Temperature -40°C…+70°C (with derating) Storage Temperature -40°C…+85°C Temperature Coefficient ±0.02%/°C Humidity 95% RH MTBF >200,000 h @ 25°C (MIL-HDBK-217F) Dimension (L x W x H) 2.91 x 2.13 x 0.87 Inches Case Material Plastic resin with Fiberglass (flammability to UL 94V-0) Weight 114 g Cooling Method Free air convection Safety Agency Approvals UL/cUL, CE, TUV EMC EMI (Conducted & Radiated Emission) EMS (Noise Immunity) EN 55024 ( 74.0 x 54.0 x 22.0 mm ) Tolerance ±0.5 mm EN 55022 class B 1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. 2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- VER : D_1 update : 2012.03.14 AC-DC Power Module ANC A-E1 SERIES 15 Watts ELECTRICAL SPECIFICATIONS Model No. ANC-5D ( Dual、Triple Output ) Max Output Wattage (W) Voltage Input Output Protection Isolation Environment Physical Safety EMC A -E1 15W ANC-12D A -E1 15W ANC-15D A -E1 15W ANC-5S12D A ANC-5S15D -E1 15W -E1 15W 5/±12 5/±15 A 90-264 VAC or 120-370 VDC Frequency (Hz) 47-440 Hz Current (Full load) 310 mA max. (115 VAC) / 170 mA max. (230 VAC) Inrush Current (<2ms) 23 A max. (115 VAC) / 46 A max. (230 VAC) Leakage Current 0.75 mA max. External Fuse (recommend) 1.5 A slow blow type Voltage (V.DC.) ±5V Voltage Accuracy ±5% Current (mA) max ±1500 Line Regulation (LL-HL) (typ.) ±0.5% ±1% / ±5% Load Regulation (5-100%) (typ.) ±3% ±2% / ±5% Minimum Load 0% Maximum Capacitive Load ±13500 uF Ripple <0.2% Vout +40mV max (Vp-p) Noise <0.5% Vout +50mV max (Vp-p) Efficiency 76% Hold-up Time 15 ms min. Switching Frequency 100 kHz ±12V ±15V ±3% ±650 ±500 5V 10% ±2700 uF 79% 14000 / ±680 uF 77% 73% 73% Hiccup technique, auto-recovery Zener diode clamp Short Circuit Protection Hiccup mode, indefinite (automatic recovery) 3000V 1500V Output-FG (V.AC) 500V Operating Temperature -40°C…+70°C (with derating) Storage Temperature -40°C…+85°C Temperature Coefficient ±0.02%/°C Humidity 95% RH MTBF >200,000 h @ 25°C (MIL-HDBK-217F) Dimension (L x W x H) 2.91 x 2.13 x 0.87 Inches Case Material Plastic resin with Fiberglass (flammability to UL 94V-0) Weight 114 g Cooling Method Free air convection Agency Approvals UL/cUL, CE, TUV EMI (Conducted & Radiated Emission) EN 55022 class B EMS (Noise Immunity) EN 55024 (200 mA) 14000 / ±900 uF Over Voltage Protection Input-FG (V.AC) 2000/±150 ±1400 uF Over Power Protection Input-Output (V.AC) 2000/±200 ( 74.0 x 54.0 x 22.0 mm ) Tolerance ±0.5 mm 1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. 2.Ripple & Noise are measured at 20MHz of bandwidth with 0.1UF & 47UF parallel capacitor. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : D_1 update : 2012.03.14 AC-DC Power Module ANC A-E1 SERIES MECHANICAL DIMENSION 15 Watts ( Top View ) BLOCK DIAGRAM http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 PIN# SINGLE Dual Triple 1 FG FG FG 2 AC IN (N) AC IN (N) AC IN (N) 3 AC IN (L) AC IN (L) AC IN (L) 4 NO PIN NO PIN -DC OUT 5 -DC OUT -DC OUT COMMON 6 NO PIN COMMON +DC OUT 7 +DC OUT +DC OUT +5V RTN 8 NO PIN NO PIN +5V OUT DERATING -3- VER : D_1 update : 2012.03.14 AC-DC Power Module ANC A-E1 SERIES 15 Watts SCREW TERMINAL ANC-E1-A2 PIN# Single Dual Triple 1 FG FG FG 2 AC IN (N) AC IN (N) AC IN (N) 3 AC IN (L) AC IN (L) AC IN (L) 4 NO CONNECT NO CONNECT -DC OUT 5 -DC OUT -DC OUT COMMON 6 NO CONNECT COMMON +DC OUT 7 +DC OUT +DC OUT +5V RTN 8 NO CONNECT NO CONNECT +5V OUT Dual Triple ANC-E1-A5 PIN# Single 1 FG FG FG 2 AC IN (N) AC IN (N) AC IN (N) 3 AC IN (L) AC IN (L) AC IN (L) 4 NO CONNECT NO CONNECT -DC OUT 5 -DC OUT -DC OUT COMMON 6 NO CONNECT COMMON +DC OUT 7 +DC OUT +DC OUT +5V RTN 8 NO CONNECT NO CONNECT +5V OUT http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -4-