FAIRCHILD 1.5KE13(C)A

1.5KE6.8(C)A - 1.5KE440(C)A
Features
•
•
•
•
•
•
Glass passivated junction.
1500W Peak Pulse Power capability
at 1.0 ms.
Excellent clamping capability.
Low incremental surge resistance.
Fast response time; typically less
than 1.0 ps from 0 volts to BV for
unidirectional and 5.0 ns for
bidirectional.
Typical IR less than 1.0 µA above 10V.
1.0 min (25.4)
Dimensions in
inches (mm)
0.375 (9.525)
0.265 (6.731)
0.210 (5.334)
0.188 (4.775)
DO-201AE
COLOR BAND DENOTES CATHODE
0.042 (1.067)
0.037 (0.940)
DEVICES FOR BIPOLAR APPLICATIONS
- Bidirectional types use CA suffix.
- Electrical Characteristics apply in both directions.
1500 Watt Transient Voltage Suppressors
Absolute Maximum Ratings*
Symbol
TA = 25°C unless otherwise noted
Parameter
PPPM
Peak Pulse Power Dissipation at TA = 25°C, TP=1ms
IPPM
Peak Pulse Current
PD
Tstg
Steady State Power Dissipation
.375 " lead length @ TA = 75°C
Peak Forward Surge Current
superimposed on rated load (JEDEC method)
Storage Temperature Range
TJ
Operating Junction Temperature
if(surge)
(Note 1)
*These ratings are limiting values above which the serviceability of any semiconductor device may be impaired.
Note 1: Measured on 8.3 ms single half-sine wave; Duty cycle = 4 pulses per minute maximum.
1998 Fairchild Semiconductor Corporation
Value
Units
minimum 1500
W
see table
A
5.0
W
200
-65 to +175
A
°C
-65 to +175
°C
1.5KE6.8(C)A - 1.5KE440(C)A
Discrete POWER & Signal
Technologies
(continued)
Electrical Characteristics
Uni-directional
Bi-directional (C)
Device
1.5KE6.8(C)A
1.5KE7.5(C)A
1.5KE8.2(C)A
1.5KE9.1(C)A
1.5KE10(C)A
1.5KE11(C)A
1.5KE12(C)A
1.5KE13(C)A
1.5KE15(C)A
1.5KE16(C)A
1.5KE18(C)A
1.5KE20(C)A
1.5KE22(C)A
1.5KE24(C)A
1.5KE27(C)A
1.5KE30(C)A
1.5KE33(C)A
1.5KE36(C)A
1.5KE39(C)A
1.5KE43(C)A
1.5KE47(C)A
1.5KE51(C)A
1.5KE56(C)A
1.5KE62(C)A
1.5KE68(C)A
1.5KE75(C)A
1.5KE82(C)A
1.5KE91(C)A
1.5KE100(C)A
1.5KE110(C)A
1.5KE120(C)A
1.5KE130(C)A
1.5KE150(C)A
1.5KE160(C)A
1.5KE170(C)A
1.5KE180(C)A
1.5KE200(C)A
1.5KE220(C)A
1.5KE250(C)A
1.5KE300(C)A
1.5KE350(C)A
1.5KE400(C)A
1.5KE440(C)A
Reverse
Stand-off Voltage
VRWM (V)
5.80
6.40
7.02
7.78
8.55
9.40
10.2
11.1
12.8
13.6
15.3
17.1
18.8
20.5
23.1
25.6
28.2
30.8
33.3
36.8
40.2
43.6
47.8
53.0
58.1
64.1
70.1
77.8
85.5
94.0
102.0
111.0
128.0
136.0
145.0
154.0
171.0
185.0
214.0
256.0
300.0
342.0
376.0
TA = 25°C unless otherwise noted
Breakdown Voltage
VBR (V)
min
max
6.45
7.13
7.79
8.65
9.50
10.5
11.4
12.4
14.3
15.2
17.1
19.0
20.9
22.8
25.7
28.5
31.4
34.2
37.1
40.9
44.7
48.5
53.2
58.9
64.6
71.3
77.9
86.5
95.0
106.0
114.0
124.0
143.0
152.0
162.0
171.0
190.0
209.0
237.0
285.0
333.0
380.0
418.0
7.14
7.88
8.61
9.55
10.5
11.6
12.6
13.7
15.8
16.8
18.9
21.0
23.1
25.2
28.4
31.5
34.7
37.8
41.0
45.2
49.4
53.6
58.8
65.1
71.4
78.8
86.1
95.5
105.0
116.0
126.0
137.0
158.0
168.0
179.0
189.0
210.0
231.0
263.0
315.0
368.0
420.0
462.0
Test
Current
IT(mA)
10
10
10
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
* For bidirectional parts with VRWM<10V, the IR max limit is doubled.
Max Clamping
Voltage @IPPM
VC(V)
10.5
11.3
12.1
13.4
14.5
15.6
16.7
18.2
21.2
22.5
26.2
27.7
30.6
33.2
37.5
41.4
45.7
49.9
53.9
59.3
64.8
70.1
77.0
85.0
92.0
104.0
113.0
125.0
137.0
152.0
165.0
179.0
207.0
219.0
234.0
246.0
274.0
328.0
344.0
414.0
482.0
548.0
602.0
Max Peak Pulse
Surge Current
IPPM (A)
143
133
124
112
103
96.2
90.0
82.0
71.0
67.0
59.5
54.2
49.0
45.2
40.0
36.2
33.0
30.1
28.0
25.3
23.2
21.4
19.5
17.7
16.3
14.6
13.3
12.0
11.0
9.9
9.1
8.4
7.2
6.8
6.4
6.1
5.5
4.6
4.5
3.8
3.2
2.8
2.6
Max Reverse
Leakage VRWM
IR (uA)*
1000
500
200
50
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
1.5KE6.8(C)A - 1.5KE440(C)A
Transient Voltage Supressors
(continued)
Typical Characteristics
Pulse Derating Curve
Peak Pulse Power Rating Curve
100
PULSE POWER (%)
PULSE POWER (kW)
100
TA = 25º C
10
1
75
50
25
0
0.1
0.0001
0.001
0.01
0.1
PULSE WIDTH (ms)
1
0
10
25
Pulse Waveform
tf = 10µsec
Peak Value
Ippm
100
TA = 25º C
Pulse Width (td) is Defined
as the Point Where the Peak
Current Decays to 50% of Ipp
Unidirectional
Unidirectional
Half Value-Ipp
2
10/1000µsec Waveform
as Defined by R.E.A.
50
Bidirectional
100
Measured at
Stand-Off
Voltage (V mw)
1
2
TIME (ms)
3
10
4
Steady State Power Derating Curve
10
FORWARD SURGE CURRENT (A)
200
3.75
2.5
1.25
0
5
0
25
50
75
100 125 150
LEAD TEMPERATURE ( º C)
175
20
50
100
200
REVERSE VOLTAGE (V)
500
Non-Repetitive Surge Current
5
POWER DISSIPATION (W)
Measured at
Zero Bias
e-kt
0
TA = 25º C
f = 1.0 MHz
Visg = 50m Vp-p
1000
td
0
200
Junction Capacitance
10000
CAPACITANCE (pF)
PEAK PULSE CURRENT (%)
150
50
75
100 125 150 175
AMBIENT TEMPERATURE (º C)
200
T A = T A max
8.3ms Single Half Sine-Wave
JEDEC Method
100
50
UNIDIRECTIONAL ONLY
20
10
1
2
5
10
20
50
NUMBER OF CYCLES AT 60Hz
100
1.5KE6.8(C)A - 1.5KE440(C)A
Transient Voltage Supressors