ARCH APC-5S-DN

VER : A_1
update : 94.08.25
AC-DC Switching Power Supply
APC DN SERIES
5
Watts
KEY FEATURES
„ Din Rail Switching Power Supply
„ Universal Input Range 90-264VAC, 47-440 Hz
„ Regulated Output
„ Low Ripple and Noise
„ High Efficiency
„ CE, UL, TUV Approval
„ 2-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Model No.
( Single Output )
APC-3.3S-DN
5W
Max Output Wattage (W)
Voltage
Output
Protection
Isolation
Environment
Physical
Safety
EMC
APC-12S-DN
5W
APC15S-DN
5W
APC24S-DN
4.8W
90-264 VAC or 120-370 VDC
Frequency (Hz)
Input
APC-5S-DN
5W
47-440 Hz
Current (Full load)
110 mA max. (115 VAC) / 70 mA max. (230 VAC)
Inrush Current (<2ms)
10 A max. (115 VAC) /20 A max. (230 VAC)
Leakage Current
0.75 mA max.
Voltage (V.DC.)
3.3V
Voltage Accuracy
±2%
Current (mA) max
1500
Line Regulation (LL-HL) (typ.)
±0.3%
Load Regulation (5-100%) (typ.)
±0.5%.
5V
12V
15V
24V
1000
416
333
200
1%
1%
0%
0%
69%
69%
65%
Minimum Load
4%
Maximum Capacitive Load
470-23,000µF depending on model
Ripple
<0.2% Vout +40mV max (Vp-p)
Noise
<0.5% Vout +50mV max (Vp-p)
Efficiency
62%
Hold-up Time
15 ms min.
Switching Frequency
100 kHz
64%
Over Power Protection
Hiccup technique, auto-recovery
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (V.AC)
3000V
Input-FG (V.AC)
1500V
Output-FG (V.AC)
500V
Operating Temperature
-25°C…+70°C (with derating)
Storage Temperature
-40°C…+85°C
Temperature Coefficient
±0.02%/°C
Humidity
95% RH
MTBF
>300,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.28 x 3.46 x 1.9 Inches
Case Material
Plastic resin with Fiberglass (flammability to UL 94V-2)
Weight
140 g
Cooling Method
Free air convection
Agency Approvals
UL/cUL, CE, TUV
EMI (Conducted & Radiated Emission)
EN 55022 class B
EMS (Noise Immunity)
EN 50082-1
( 58.0 x 88.0 x 48.0 mm )
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : A_1
update : 94.08.25
AC-DC Switching Power Supply
APC DN SERIES
5
Watts
ELECTRICAL SPECIFICATIONS
Model No.
( Dual Output )
Max Output Wattage (W)
Voltage
Output
Protection
Isolation
Environment
Physical
Safety
EMC
APC-12D-DN
APC15D-DN
5W
4.8W
4.8W
90-264 VAC or 120-370 VDC
Frequency (Hz)
Input
APC-5D-DN
47-440 Hz
Current (Full load)
110 mA max. (115 VAC) / 70 mA max. (230 VAC)
Inrush Current (<2ms)
10 A max. (115 VAC) /20 A max. (230 VAC)
Leakage Current
0.75 mA max.
Voltage (V.DC.)
±5V
Voltage Accuracy
±2%
Current (mA) max
±500
Line Regulation (LL-HL) (typ.)
±0.3%
±12V
±15V
±200
±160
0%
3%
Load Regulation (5-100%) (typ.)
±0.5%.
Minimum Load
0%
Maximum Capacitive Load
470-23,000µF depending on model
Ripple
<0.2% Vout +40mV max (Vp-p)
Noise
<0.5% Vout +50mV max (Vp-p)
Efficiency
70%
Hold-up Time
15 ms min.
Switching Frequency
100 kHz
67%
Over Power Protection
Hiccup technique, auto-recovery
Over Voltage Protection
Zener diode clamp
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
Input-Output (V.AC)
3000V
Input-FG (V.AC)
1500V
Output-FG (V.AC)
500V
Operating Temperature
-25°C…+70°C (with derating)
Storage Temperature
-40°C…+85°C
Temperature Coefficient
±0.02%/°C
Humidity
95% RH
MTBF
>300,000 h @ 25°C (MIL-HDBK-217F)
Dimension (L x W x H)
2.28 x 3.46 x 1.9 Inches
Case Material
Plastic resin with Fiberglass (flammability to UL 94V-2)
Weight
140 g
Cooling Method
Free air convection
Agency Approvals
UL/cUL, CE, TUV
EMI (Conducted & Radiated Emission)
EN 55022 class B
EMS (Noise Immunity)
EN 50082-1
67%
( 58.0 x 88.0 x 48.0 mm )
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : A_1
update : 94.08.25
AC-DC Switching Power Supply
APC DN SERIES
MECHANICAL DIMENSION
5
Watts
( Top View )
PIN#
SINGLE
Dual
1
FG
FG
2
3
4
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
DO NOT CONNECT
AC IN (N)
DO NOT CONNECT
DO NOT CONNECT
AC IN (N)
DO NOT CONNECT
5
AC IN (L)
AC IN (L)
6
-DC OUT
-DC OUT
7
DO NOT CONNECT
COMMON
8
+DC OUT
+DC OUT
DERATING
-3-