HONEYWELL APS00B

APS00B
DESCRIPTION
Honeywell’s APS00B High Resolution Magnetic Angular
Position Sensor IC (Integrated Circuit) is a miniature surface
mount device for angular or rotary displacement designed for
magnetic saturating field sensing.
The APS00B creates an analog output voltage that varies with
the direction of the magnetic flux passing over the IC surface.
It contains dual saturated-mode Wheatstone bridges that
generate quadrature (sine and cosine) signals to provide an
extended range of angular measurements up to 180°.
This product is a cost-effective and space-efficient solution for
high volume OEM designs. Potential applications include
position sensing, rotary speed and angle detection, and noncontact precision location measurement systems.
APS00B sensor ICs use Honeywell’s Anisotropic
Magnetoresistive (AMR) technology that provides advantages
over Hall-effect based magnetic sensors. They are able to
resolve better than a tenth of a degree or a tenth of a
millimeter, withstand large variations in magnet-to-sensor
gaps, and exhibit insensitivity to shocks and vibrations.
Honeywell’s Magnetic Sensors are among the most precision
and reliable position sensors in the industry.
These surface mount devices are mounted directly on the
electrical traces on a PC (printed circuit) board. They are
attached by an automatic solder reflow operation which
requires no hole, so it may help reduce the cost of the PC
board.
FEATURES AND BENEFITS
Wide angular range allows measurements of ±90° without
additional components make this device suitable for a variety
of angular sensing applications; ±180° measurement is
possible with external components
Resolution capability of less than 0.05° helps improve overall
system accuracy
Absolute sensing means no indexing is required and the
exact target position is known, simplifying the system design
Dual 4-element Wheatstone bridges provide a passive
element, low-noise design, helping improve system
performance
Small, SOIC-8 surface mount package saves room on the
PC board when compared to larger IC packages and
components
RoHS-compliant materials meet Directive 2002/95/EC
Tape and reel configuration allows use with automated pickand-place equipment, potentially reducing assembly costs.
(178 mm [7 in]) and 330 mm [13 in] reels available)
Typical 0 MHz to 5 MHz frequency response with 190 G
minimum magnetic field applied, makes this saturated mode
sensor IC potentially suitable for high speed applications
Typically requires only 5 V at 4 mA to operate (20 mW),
promoting energy efficiency
The devices measure only field direction and are virtually
unaffected by shock, vibration and magnetic-source gap
variations, providing a stable, reliable output
Dual bridges with outputs 45° out of phase make it possible
to use outputs as speed and direction signals
Honeywell APS00A instrumentation amplifier available for
additional signal processing
.
APS00B
POTENTIAL APPLICATIONS
Transportation:
High accuracy angular position sensing
Rotary speed and angle detection
Non-contact precision displacement sensing
Speed and direction sensing
Industrial:
High accuracy angular position sensing
Rotary speed and angle detection
Non-contact precision displacement sensing
Valve position
Robotics control
Medical:
High accuracy angular position sensing
Rotary speed and angle detection
Non-contact precision displacement sensing
Table 1. Absolute Maximum Ratings*
Parameter
Supply voltage
Power Dissipation
Operating Temperature
Magnetic flux
Min.
-12
–
-55 [-67]
–
Max.
+12
200
150 [302]
no limit
Unit
V
mW
°C [°F]
Gauss
*Absolute maximum ratings are the extreme limits the device will withstand without damage to the device. However, the electrical
and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are
approached, nor will the device necessarily operate at absolute maximum ratings.
Table 2. Characteristics (At Vs = 5.0 V and Ta = 25 °C [77 °F] unless otherwise noted.)
Parameter
Condition
Typ.
Max.
Unit
Supply voltage
–
–
5
12
V
Operatingt Temperature
–
-40 [-40]
–
150 [302]
°C [°F]
bridges are connected in parallel
0.9
1.25
1.6
kOhm
–
4.0
7.0
mA
around zero crossing
–
2.1
2.3
mV/°
Bridge resistance
Supply current
Sensitivity
B > saturation field
-90
–
+90
°
Resolution
–
–
0.05
–
°
Max. output amplitude
–
47.5
57.5
67.5
mV
Min. output amplitude
–
-47.5
-57.5
-67.5
mV
Output amplitude (peak to peak)
–
95
115
135
mV
Offset voltage
–
-1
–
1
mV
Amplitude change
at 140°C [284°F]
-34
–
-43
%
Amplitude change
at -40°C [-40 °F]
24
–
31
%
–
-2
–
2
mV
(Amp A/Amp B) * 100
97
–
103
%
–
-1
–
1
%
<10 μV/Gauss amplitude change
60
190
–
Gauss
Angle range
Offset shift
Synchronism
Synchronism shift
Saturation level
Bandwidth
2
Min.
www.honeywell.com/sensing
–
0 to 5.0
MHz
Figure 1. Detection of Relative Motion of a Magnet in Angular Displacement
The APS00B sensor can used to detect the relative motion of a magnet in
angular displacement.
Given a typical supply voltage of 5 V, each bridge will provide about 115 mV of
swing (±57.5 mV) on top of 2.5 V bias voltage. With +5 V applied to it, the
bridge performs a rail splitter function to create two near +2.5 V sources driven
apart by V as created by the magnetic field and the offset error voltage.
The bridge differential output voltages ( V) for the APS00B are:
VA = Vs S sin (2 θ) and VB = Vs S cos (2 θ) where:
Vs = Supply Voltage (V)
S = Material Constant = ( R/Rmax) *(1/2) = 11.5 mV/V nominal
θ = Reference to Magnetic Field Angle (°)
Please refer to Application Sheet “How to Apply Honeywell APS00B Angular
Position Sensors ICs” for additional details.
Figure 2. Electrical Diagram
Figure 3. Pinout and Sensing Element Location
The APS00B has two sensor bridges optimized for
rotary sensing applications. Thus the die is centered in
all three dimensions within the SOIC-8 package. The
figure below indicates the pin identification and the
sensing element location.
Bridge “A” output:
VoutA = Vs*S*sin(2θ) + VosA,
Bridge “B” output:
VoutB = Vs*S*cos(2θ) + VosB
where:
S = 11.5 mV/V nominal
VosA = Bridge A Offset
(nominal = 0 V)
where:
S = 11.5 mV/G nominal
VosB = Bridge B Offset
(nominal = 0 V)
Bridge A is centroidally co-located with Bridge B, and Bridge A
elements are rotated by 45° relative to Bridge B elements as
shown.
Figure 4. Typical Bridge Outputs vs Rotation Angle
Honeywell Sensing and Control
3
APS00B
Figure 5. Common Wiring Diagrams
Figure 6. Typical Wiring Diagram with Honeywell APS00A Instrumentation Amplifier
4
www.honeywell.com/sensing
Figure 7. Mounting Dimensions (All dimensions for reference only: mm/[in].)
SOIC-8 Package
Tape
Standard Reel (178 mm [7 in])
Large Reel (330 mm [13 in])
APS00M Magnet
23,5 Dia.
[0.93]
Magnetization
Direction
11,0
[0.43]
3,35
[0.13]
Honeywell Sensing and Control
5
Order Guide
Catalog Listing
APS00B
APS00B-T13
APS00A
APS00M
Description
High resolution magnetic angular position sensor IC, SOIC-8 surface-mount package, on tape and reel,
1,000 pieces on standard reel (178 mm [7 in])
High resolution magnetic angular position sensor IC, SOIC-8 surface-mount package, on tape and reel,
4,000 pieces on large reel (330 mm [13 in])
Instrumentation amplifier for APS00B, SOIC-8 surface-mount package, on tape and reel, 1,000 pieces on
standard reel (178 mm [7 in])
Special magnet for APS00B
WARNING
WARNING
PERSONAL INJURY
DO NOT USE these products as safety or emergency stop
devices or in any other application where failure of the
product could result in personal injury.
Failure to comply with these instructions could result
in death or serious injury.
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of
defective materials and faulty workmanship. Honeywell’s
standard product warranty applies unless agreed to otherwise
by Honeywell in writing; please refer to your order
acknowledgement or consult your local sales office for specific
warranty details. If warranted goods are returned to Honeywell
during the period of coverage, Honeywell will repair or replace,
at its option, without charge those items it finds defective. The
foregoing is buyer’s sole remedy and is in lieu of all other
warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no
event shall Honeywell be liable for consequential, special,
or indirect damages.
While we provide application assistance personally, through
our literature and the Honeywell web site, it is up to the
customer to determine the suitability of the product in the
application.
Specifications may change without notice. The information we
supply is believed to be accurate and reliable as of this
printing. However, we assume no responsibility for its use.
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for
reference only. DO NOT USE this document as a
product installation guide.
Complete installation, operation, and maintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result
in death or serious injury.
SALES AND SERVICE
Honeywell serves its customers through a worldwide network
of sales offices, representatives and distributors. For
application assistance, current specifications, pricing or name
of the nearest Authorized Distributor, contact your local sales
office or:
E-mail: [email protected]
Internet: www.honeywell.com/sensing
Phone and Fax:
Asia Pacific
+65 6355-2828
+65 6445-3033 Fax
Europe
+44 (0) 1698 481481
+44 (0) 1698 481676 Fax
Latin America
+1-305-805-8188
+1-305-883-8257 Fax
USA/Canada
+1-800-537-6945
+1-815-235-6847
+1-815-235-6545 Fax
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com/sensing
005924-2-EN IL50 GLO Printed in USA
August 2011
© 2011 Honeywell International Inc. All rights reserved.