ARCH AQF600-24S

VER : PA_1
update : 2012.03.09
AC-DC Switching Power Supply
AQF600 SERIES
600 Watts
KEY FEATURES
„ Universal Input: 90-264 VAC
„ With P.F.C. Function, PF>0.95
„ Remote Sense Function
„ Remote ON/OFF Function
„ Current Share Function
„ Power Good Function
„ Protections: Over Load / Over Voltage / Over Temperature /
Short Circuit All by Auto-recovery
„ High Power Density
„ RoHS Compliant Design
„ 3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Model No.
Max Output Wattage (Convection)
Voltage
Input
Output
Protection
Isolation
Function
Environment
(W)
AQF600-12S
AQF600-24S
AQF600-28S
AQF600-36S
AQF600-48S
AQF600-54S
480W
600W
600W
600W
600W
600W
90-264 VAC or 120-370 VDC
Frequency (Hz)
47-63 Hz
Current (Full load)
< 0.8 A max. (115 VAC) / < 4.0 A max. (230 VAC)
Inrush Current (<2ms)
< 30 A max. (115 VAC) / < 60 A max. (230 VAC)
Leakage Current
< 3.5 mA max.(240VAC 63Hz)
Power Factor
PF>0.98 (115 VAC) / PF>0.93 (230 VAC) at Full Load
Voltage (V.DC.)
12V
Trim
±5%
Voltage Accuracy
±2%
Current (Convection) (A) max
40
Line Regulation (LL-HL) (typ.)
±1%
Load Regulation (5-100%) (typ.)
±1%
Minimum Load
5%
Maximum Capacitive Load
70,000 uF
Ripple & Noise (max.)
< 1%
Efficiency (typ.)
90%
Hold-up Time
12 ms min.
Switching Frequency
100 kHz
Over Power Protection
Auto recovery
Over Voltage Protection
Auto recovery
Over Temperature
Auto recovery
Short Circuit Protection
Auto-recovery
Input-Output (V.AC)
3000V
Input-FG
(V.AC)
1500V
Output-FG
.(V.AC)
24V
28V
36V
48V
54V
25
21.4
16.6
12.5
11.1
60,000 uF
48,000 uF
30,000 uF
20,000 uF
10,000 uF
91%
92%
92%
93%
93%
500V
5V Stand by (18CFM FAN)
5VSB: [email protected] ; Tolerance ±10% , Ripple & Noise: 100m Vp-p (max.)
DC OK Signal
Turn ON: 4~6V ; Turn OFF: 0~1V
Remote Control
+RC / -RC: Power ON=open ; Power OFF=short
FAN Control
12VDC / 0.5A max.
Operating Temperature
-25°C…+70°C (with derating)
Storage Temperature
-25°C…+85°C
Temperature Coefficient
±0.03%/°C ( 0~50°C )
Humidity
95% RH
MTBF
>120,000 h @ 25°C (MIL-HDBK-217F)
Vibration
10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes.
1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : PA_1
update : 2012.03.09
AC-DC Switching Power Supply
AQF600 SERIES
600 Watts
ELECTRICAL SPECIFICATIONS
Model No.
Physical
Safety
EMC
AQF600-12S
AQF600-24S
Dimension (L x W x H)
9.0 x 4.13 x 1.72 Inches
Weight
1200 g
Cooling
Convection Cooled
Agency Approvals
CE, UL60950
AQF600-28S
AQF600-36S
AQF600-48S
AQF600-54S
(228.5 x 105.0 x 44.0 mm ) Tolerance ±0.5 mm
(Pending)
EMI (Conducted & Radiated Emission)
EN 55022 class B, Radiated Class A (Pending)
EMS (Noise Immunity)
EN 55024
(Pending)
1. All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
BLOCK DIAGRAM
DERATING
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : PA_1
update : 2012.03.09
AC-DC Switching Power Supply
AQF600 SERIES
600 Watts
MECHANICAL DIMENSION
AC Input Terminal Pin
PIN#
SINGLE
1
AC IN
DC Output Terminal Pin
PIN#
SINGLE
2~4
+DC OUT
5~7
-DC OUT
Connector Pin (CN4)
PIN#
SINGLE
C1
+S
C2
-S
C3
+RC
C4
-RC
C5
+PG
C6
GND
C7
+5V SB
C8
-5V SB
C9
N.C
C10
CS
ASSEMBLY INSTRUCTIONS
*U Case T=2.0mm
Customer screws into the length of the case no higher than 0.5mm
(Namely screw length for load plate thickness plus 2.5mm
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-3-
VER : PA_1
update : 2012.03.09
AC-DC Switching Power Supply
AQF600 SERIES
600 Watts
FUNCTION DESCRIPITON of CN4 :
Pin No.
Function
C1
+S
C2
-S
C3
+RC
C4
-RC
C5
DC-OK
Description
Positive sensing. The +S signal should be connected to the positive terminal of the load.
The +S and -S leads should be twisted in pair to minimize noise pick-up effect.
The maximum line drop compensation is 0.5V. (max.)
Negative sensing. The -S signal should be connected to the negative terminal of the load.
The -S and +S leads should be twisted in pair to minimize noise pick-up effect.
The maximum line drop compensation is 0.5V. (max.)
Turns the output on and off by electrical or dry contact between pin C4 (-RC), Short: Power OFF, Open: Power ON.
Remote control ground.
DC-OK Signal is a DC output, referenced to pinC6(DC-OK GND).
C6
GND
C7
+5V SB
Stand by voltage output ground 4.5~5.5V, referenced to pin C8(-5V SB). The maximum load current is 0.6A.
This pin connects to the negative terminal(-V). Return for DC-OK signal output.
C8
-5V SB
Stand by voltage output ground.
C9
N.C
No Pin
C10
CS
Current Share Function Pin
FUNCTION MANUAL :
1. Remote Sense
The remote sensing compensates voltage drop on the load wiring up to 0.5V. (max.)
2. DC-OK Signal
Between DC-OK(pinC5)
and GND(pinC6)
Output
Status
4~6V
0~1V
ON
OFF
3. Remote Control
It can be turned ON/OFF by using the "Remote Control" function.
Between RC+(pinC3) and
RC-(pinC4)
Output
Status
SW ON (Short)
SW OFF (Open)
OFF
ON
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-4-