HRPG-300 300W Single Output with PFC Function series Features : Universal AC input / Full range Built-in active PFC function, PF>0.95 High efficiency up to 89% (typ.) Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload / Over voltage / Over temperature Built-in constant current limiting circuit 1U low profile 41mm Built-in cooling fan ON-OFF control With DC OK signal output Built-in remote ON-OFF control Standby [email protected] Built-in remote sense function No load power consumption<0.5W 5 years warranty SPECIFICATION MODEL OUTPUT HRPG-300-3.3 HRPG-300-5 HRPG-300-7.5 HRPG-300-12 HRPG-300-15 HRPG-300-24 HRPG-300-36 HRPG-300-48 DC VOLTAGE 3.3V 5V 7.5V 12V 15V 24V 36V 48V RATED CURRENT 60A 60A 40A 27A 22A 14A 9A 7A CURRENT RANGE 0 ~ 60A 0 ~ 60A 0 ~ 40A 0 ~ 27A 0 ~ 22A 0 ~ 14A 0 ~ 9A 0 ~ 7A RATED POWER 198W 300W 300W 324W 330W 336W 324W 336W RIPPLE & NOISE (max.) Note.2 80mVp-p 90mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p 250mVp-p 250mVp-p VOLTAGE ADJ. RANGE 4.3 ~ 5.8V 2.0% 6.8 ~ 9V 2.0% 10.2 ~ 13.8V 1.0% 13.5 ~ 18V 1.0% 21.6 ~ 28.8V 1.0% 28.8 ~ 39.6V 1.0% 40.8 ~ 55.2V 1.0% 2.8 ~ 3.8V VOLTAGE TOLERANCE Note.3 2.5% LINE REGULATION 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% LOAD REGULATION 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE TIME 1000ms, 50ms/230VAC HOLD UP TIME (Typ.) 16ms/230VAC 16ms/115VAC at full load VOLTAGE RANGE Note.5 85 ~ 264VAC FREQUENCY RANGE 47 ~ 63Hz INPUT PF>0.95/230VAC EFFICIENCY (Typ.) 80% 82% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 5A/115VAC 35A/115VAC 2.5A/230VAC 70A/230VAC LEAKAGE CURRENT <1.2mA / 240VAC OVER VOLTAGE PF>0.99/115VAC at full load 86% 88% 88% 87% 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed 6 ~ 7V 9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V 3.96 ~ 4.62V 88% 89% 41.4 ~ 48.6V 57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover 90 FUNCTION 120 ~ 370VDC POWER FACTOR (Typ.) OVERLOAD PROTECTION 2500ms, 50ms/115VAC at full load 5 (TSW1: detect on heatsink of power transistor) 5 for 3.3V,5V,7.5V ; 95 5 for others (TSW2: detect on heatsink of power diod e) OVER TEMPERATURE 100 5V STANDBY Protection type : Shut down o/p voltage, recovers automatically after temperature goes down 5VSB : [email protected] ; tolerance 5%, ripple : 50mVp-p(max.) DC OK SIGNAL PSU turns on : 3.3 ~ 5.6V ; PSU turns off : 0 ~ 1V REMOTE CONTROL RC+ / RC-: 4 ~ 10V or open = power on ; 0 ~ 0.8V or short = power off FAN CONTROL (Typ.) Load 35 15% or RTH2 WORKING TEMP. -30 ~ +70 50 Fan on (Refer to output load derating curve) 20 ~ 90% RH non-condensing WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY -40 ~ +85 , 10 ~ 95% RH TEMP. COEFFICIENT 0.03%/ (0 ~ 50 ) VIBRATION 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC (Note 4) ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT OTHERS / 70% RH EMS IMMUNITY Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11, ENV50204, EN55024, EN61000-6-2, heavy industry level, criteria A MTBF 176K hrs min. DIMENSION 199*105*41mm (L*W*H) 0.95Kg;15pcs/15.3Kg/0.69CUFT PACKING NOTE UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC MIL-HDBK-217F (25 ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details. File Name:HRPG-300-SPEC 2009-11-09 HRPG-300 300W Single Output with PFC Function Mechanical Specification Unit:mm 18 12.5 Case No.980A series 4-M4 L=6 168.5 12.25 168.5 R2 .25 199 1.5 12.25 168.5 18 HOLE IN CHASSIS 120 4.5 42.5 1 Assignment Pin No. DC OUTPUT -V 4,5 6,7 DC OUTPUT +V FAN 5 6 Air flow direction 15 1 7 2 8 7 LED CN100 SVR Terminal HRS DF11-**SC or equivalent HRS DF11-8DS or equivalent 167.5 12.25 167.5 12.25 17max. 12.5 18 41 Mating Housing 4-M4 L=6 fosc : 70KHz Block Diagram ACTIVE INRUSH CURRENT LIMITING EMI FILTER I/P 75 105 125 4 Connector Pin No. Assignment (CN100) : HRS DF11-8DP-2DS or equivalent Pin No. Assignment AUX 1 AUXG 2 DC-OK 3 RC4 GND 5 RC+ 6 +S 7 -S 8 3 9.2 Assignment AC/L AC/N FG Pin No. 1 2 3 4-M4 L=5 2 11 Terminal Pin No. Assignment AUX POWER RECTIFIERS & FILTER AUX AUXG +S RECTIFIERS & PFC POWER SWITCHING RECTIFIERS & FILTER +V -V O.T.P. O.L.P. -S DC-OK DETECTION CIRCUIT FG PFC CONTROL O.V.P. PWM CONTROL RC+ REMOTE CONTROL Derating Curve RC- Output Derating VS Input Voltage Ta = 25 100 100 90 80 80 70 50 LOAD(%) LOAD (%) 60 40 20 -30 0 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 (HORIZONTAL) 60 50 40 85 100 125 135 155 264 INPUT VOLTAGE (V) 60Hz File Name:HRPG-300-SPEC 2009-11-09 HRPG-300 300W Single Output with PFC Function series Function Description of CN100 Pin No. Function Description Auxiliary voltage output, 4.6~5.25V, reference to pin 2(AUXG). The maximum load current is 0.3A. This output has the built-in oring 1 AUX diodes and is not controlled by the "remote ON/OFF control". Auxiliary voltage output ground. The signal return is isolated from the output terminals (+V & -V). DC-OK signal is a TTL level signal, referenced to pin5(DC-OK GND). High when PSU turns on. 2 3 4 5 6 AUXG DC-OK RCGND RC+ 7 +S Remote control ground. This pin connects to the negative terminal(-V). Return for DC-OK signal output. Turns the output on and off by electrical or dry contact between pin 4 (RC-), Short: Power OFF, Open: Power ON. Positive sensing. The +S signal should be connected to the positive terminal of the load. The +S and -S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. 8 -S Negative sensing. The -S signal should be connected to the negative terminal of the load. The -S and +S leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Function Manual 1.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. CN100 1 2 3 4 5 1 7 CN100 6 AUX DC-OK GND 2 AUXG RC- RC+ +S 7 -S 8 1 7 2 8 -S (Pin8) LOAD - + Sense lines should be twisted in pairs +S (Pin7) Fig 1.1 2.DC-OK Signal DC-OK signal is a TTL level signal. High when PSU turns on. Between DC-OK(pin6) and GND(pin4) Output Status 3.3 ~ 5.6V ON 0 ~ 1V OFF CN100 1 2 3 4 5 6 1 7 CN100 AUX DC-OK GND 2 AUXG RC- RC+ +S 7 -S 8 1 7 2 8 Fig 2.1 File Name:HRPG-300-SPEC 2009-11-09 HRPG-300 300W Single Output with PFC Function series 3.Remote Control The PSU can be turned ON/OFF by using the "Remote ON/OFF" function Between RC+(pin3) and RC-(pin5) Output Status SW ON (Short) OFF SW OFF (Open) ON CN100 1 2 3 4 5 6 7 CN100 1 AUX DC-OK GND 2 AUXG RC- RC+ +S 7 -S 8 1 7 2 8 SW Fig 3.1 File Name:HRPG-300-SPEC 2009-11-09