IRF ASA2812S/CH

PD-94539A
ASA28XXS SERIES
28V Input, Single Output
HYBRID-HIGH RELIABILITY
DC/DC CONVERTER
Description
The ASA28XXS Series of DC/DC converters are high
reliability thick film hybrid converters that use flyback
topology operating at a nominal frequency of 550KHz.
High input to output isolation is achieved through the
use of transformers in the flyback power and feedback
circuits.
The advanced feedback design provides fast loop
response for superior line and load transient
characteristics and offers greater reliability than devices
incorporating optical feedback circuits.
This device is designed to meet MIL-STD-704D input
requirements offering full performance over a 16V to
40V input range. Output Power of up to 5W is available.
Connecting the inhibit pin (pin 5) to the input common
(pin 7) will cause the converter to shut down. It is
recommended that the inhibit pin be driven by an open
collector device capable of sinking at least 400µA. The
open circuit voltage of the inhibit pin is 11.5 ± 0.5V.
Manufactured in a facility fully qualified to MIL-PRF38534, these converters are fabricated utilizing DSCC
qualified processes. For available screening options,
refer to device screening table in the data sheet.
Variations in electrical, mechanical and screening
requirements can be accommodated. Extensive
computer simulation using complex modeling allows
design modifications to be examined. Contact IR Santa
Clara with specific requirements.
www.irf.com
ASA
Features
Up To 5.0W Output Power
5V, 12V,15V Outputs
High Reliability
Wide Input Voltage Range -16V To 40V
Indefinite Short Circuit and Overload Protection
Popular Industry Standard Pin-Out
Military Screening Available
Parallel Seam Welded Package
No External Capacitors Required
Input Voltage Surge Protected to MIL-STD-704A
Under Voltage Lockout
Available as Standard Military Drawing
Standard Microcircuit Drawings Available
1
01/11/07
ASA28XXS Series
Specifications
Absolute Maximum Ratings
Input voltage
-0.5V to +50VDC Continous, 80V, 100 msec
Power output
Internally limited ( 6.5W typical )
Soldering temperature
300°C for 10 seconds
Operating case temperature
-55°C to +125°C
Storage case temperature
-65°C to +135°C
Conditions
-55° ≤ TC ≤+125°C
VIN = 28V dc ±5% C L = 0
unless otherwise specified
TEST
Output voltage
Output current
IOUT = 0
1
2
Output ripple voltage
Line regulation
Load regulation
2
Efficiency
Min
Max
Min
Max
Min
Max
1
4.95
5.05
11.88
12.12
14.85
15.15
2, 3
4.90
5.10
11.76
12.24
14.70
15.30
Capacitive load
Power dissipation, load
fault
Switching frequency
4
Output response to step
6
transient load changes
1000
417
333
mA
190
200
200
mV PP
2, 3
475
290
290
VIN = 16, 28, and 40 V dc
IOUT = 0, 50%, 100% IMAX
1
25
±25
±25
2, 3
50
±50
±50
VIN = 16, 28, and 40 V dc
IOUT = 0, 50%, 100% IMAX
1
25
±25
±25
2, 3
50
±50
±50
IOUT = IMAX
1, 2, 3
1, 2, 3
1
VTEST 500 Vdc, Tc= +25°C
1
No effect on dc
performance, Tc = +25°C
4
Overload
5
IOUT = IMAX
½ IMAX IMAX
18
50
100
100
100
100
1, 2, 3
71
71
68
68
100
100
200
4.0
4.0
4.0
2.0
2.0
2.0
500
600
-300
+300
5, 6
-450
+450
4
-500
+500
5, 6
-750
+700
mA PP
MΩ
200
4
mA
%
500
4, 5, 6
mV
500
600
500
600
-450
+450
-400
+450
-750
+750
-800
+750
µF
W
KHz
mV pk
100
100
µs
1.0
1.0
1.0
ms
4, 5, 6
500
1000
1000
mV pk
Input step 16 40 V dc
IOUT = IMAX
4, 5, 6
800
800
800
µs
IOUT = 0 mA, IMAX
4, 5, 6
600
600
600
mV pk
IOUT = IMAX
Output response
transient step line
4 8
changes
Input step 16 40 V dc
IOUT = IMAX
Recovery time transient
4, 7, 8
step line changes
Turn on overshoot
Load fault recovery
18
50
mV
200
Recovery time, step
transient load changes
Turn on delay
18
50
66
Short circuit
0 mA IMAX
9
V
1
2, 3
3, 4
Unit
1, 2, 3
IOUT = IMAX
Isolation - Input to output
or any pin to case
ASA2815S/xx
VIN = 16, 28 and 40 V dc
IOUT = 0 Pin5 open
Input ripple current
ASA2812S/xx
VIN = 16, 28, and 40 V dc
IOUT = 0 Pin 5 to Pin 7
Input current
ASA2805S/xx
Group A
Subgroups
0 mA ½ IMAX
IOUT = 0 or IMAX
4
4, 5, 6
4, 5, 6
20
25
25
ms
4, 5, 6
20
25
25
ms
For Notes to Specifications, refer to page 3
2
www.irf.com
ASA28XXS Series
Notes to Specifications
1.
2.
3.
4.
5.
6.
7.
8.
9.
Parameter guaranteed and measured during line and load regulation tests.
Bandwidth guaranteed by design. Tested for 20KHz to 2MHz.
Capacitive load may be any value from 0 to the maximum limit without compromising dc performance. A capacitive load in excess
of the maximum limit will not disturb loop stability but may interfere with the operation of the load fault detection circuitry,
appearing as a short circuit during turn-on.
Parameter shall be tested as part of design characterization and after design or process changes.
An overload is that condition of load in excess of rated load but less than that necessary to trigger the short circuit protection
and is the condition of maximum power dissipation.
Load step transition time between 2µs and 10µs.
Recovery time is measured from the initiation of the transient to where VOUT has returned to within ±1% of VOUT at 50% load.
Input step transition time between 2µs and 10µs.
Turn-on delay time measurement is for either a step application of power at the input or the removal of a ground signal from the
inhibit pin (pin 2) while power is applied to the input.
Block Diagram
1
6
+Output
+Input
Output
Return
2
Error
Amplifier
Input
Return
Case
7
8
Inhibit
Controller
5
Standard Microcircuit Drawing Equivalence Table
Standard Microcircuit
Drawing Number
www.irf.com
IR Standard
Part Number
5962-94629
ASA2805S
5962-94630
5962-94631
ASA2815S
ASA2812S
3
ASA28XXS Series
Mechanical Outline
1.075
0.800
1
2
3
0.270
4
5
0.800
±.005
1.075
8
7
6
0.025 ± .003 Dia Pins
0.220
Pin Designation
4
Pin #
Designation
1
+ Output
2
Output Return
3
NC
4
NC
5
Inhibit
6
+ Input
7
Input Return
8
Case Ground
www.irf.com
ASA28XXS Series
Device Screening
Requirement
MIL-STD-883 Method
ES HB
CH
-20°C to +85°C -55°C to +125°C -55°C to +125°C -55°C to +125°C
Temperature Range
Element Evaluation
No Suffix
MIL-PRF-38534
N/A
N/A
N/A
Class H
2023
N/A
N/A
N/A
N/A
Internal Visual
2017
Yes
Yes
Yes
Temperature Cycle
1010
N/A
Cond B
Cond C
Cond C
Constant Acceleration
2001, Y1 Axis
N/A
500 Gs
3000 Gs
3000 Gs
PIND
2020
N/A
N/A
N/A
N/A
Non-Destructive
Bond Pull
Burn-In
1015
N/A
48 hrs@hi temp
Final Electrical
MIL-PRF-38534
25°C
25°C ( Group A )
& Specification
160 hrs@125°C 160 hrs@125°C
-55°C, +25°C,
-55°C, +25°C,
+125°C
+125°C
PDA
MIL-PRF-38534
N/A
N/A
N/A
10%
Seal, Fine and Gross
1014
Cond A
Cond A, C
Cond A, C
Cond A, C
Radiographic
2012
N/A
N/A
N/A
N/A
External Visual
2009
Yes
Yes
Yes
Notes:
Best commercial practice
Sample tests at low and high temperatures
-55°C to +105°C for AHE, ATO, ATW
Part Numbering
ASA 28 05 S /CH
Model
Screening Level
Input Voltage
No Suffix, ES, HB, CH
28 = 28V
Output Voltage
05 = 5V
12 = 12V
15 = 15V
(Please refer to Screening Table)
Output
S = Single
WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, Tel: (310) 252-7105
IR SANTA CLARA: 2270 Martin Av., Santa Clara, California 95050, Tel: (408) 727-0500
Visit us at www.irf.com for sales contact information.
Data and specifications subject to change without notice.01/2007
www.irf.com
5