SX TESTING HIGH SENSITIVITY RELAY WITH GUARANTEED LOW LEVEL SWITCHING CAPACITY SX-RELAYS FEATURES 15.0 .591 7.4 .291 8.2 .323 15.0 .591 7.4 .291 Max. 10.0 .394 1. High contact reliability over a long life has been made possible for low level loads. Using a low level load (1 mV 10µA to 10 V 10 mA) 107 operations were achieved with a static contact resistance of Max. 100 mΩ (voltage drop of 20 mV, 1 mA, 1 kHz) and a dynamic contact resistance of Max. 1 Ω (Measurement delay 10 ms, voltage drop of 20 mV, 1 mA, 1 kHz). 2. High sensitibity of 50 mW By using the highly efficient polar magnetic circuit "seesaw balance armature mechanism", a rated power consumption of 50 mW (for single side stable type) has been achieved. 3. Low thermal electromotive force Reducing the heat from the coil enables a thermal electromotive force of 3 µV or less. mm inch SPECIFICATIONS Contact Characteristics Arrangement Static contact resistance (During initial and electric life tests)*1 (By voltage drop of 20 mV 1 mA [1kHz]) Dynamic contact resistance (During initial and electric life tests)*1 (By voltage drop of 20 mV 1 mA[1 kHz], Measurement delay 10 ms after applying nominal coil voltage) Contact material Nominal switching capacity (resistive load) Max. switching power Rating Max. switching voltage Max. switching current Min. switching capacity**1 Single side stable Nominal operating power 1 coil latching 2 coil latching Thermal electromotive force, max. (at nominal voltage applied to the coil**2) Mechanical (at 750 cpm) Expected life (min. Electrical (at 750 cpm) operations) (10 mA 10 V DC resistive load) 2 Form C Max. 100 mΩ Max. 1 Ω Gold-clad silver alloy 10 mA 10 VDC 0.1 W 10 VDC 10 mA DC 10 µA 1 mVDC 50mW (1.5 to 12 V DC) 70mW (24 V DC) 35mW (1.5 to 12 V DC) 50mW (24 V DC) 70mW (1.5 to 12 V DC) 150mW (24 V DC) 3 µV 5 × 107 107 Notes: **1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. **2 For single side stable only. TYPICAL APPLICATIONS This relay will be used for the small load for measuring instruments or others where a stable contact resistance is required. 120 Initial insulation resistance*2 Initial breakdown voltage*3 Between open contacts Between contact sets Between contact and coil Operate time [Set time]*4 (at 20°C) Release time (without diode) [Reset time]*4 (at 20°C) Temperature rise*5 (at 20°C) Functional*6 Shock resistance Destructive*7 Functional*8 Vibration resistance Destructive Conditions for operation, transport and storage*9 (Not freezing and condensing at low temperature) Unit weight Min. 10,000MΩ (at 500V DC) 750 Vrms for 1min. 1,000 Vrms for 1min. 1,800 Vrms for 1min. Max. 5 ms (Approx. 3 ms) [Max. 5 ms (Approx. 3 ms)] Max. 5 ms (Approx. 1.5 ms) [Max. 5 ms (Approx. 3 ms)] Max. 50°C Min. 750 m/s2{75G] Min. 1,000 m/s2{100G] 10 to 55 Hz at double amplitude of 3.3 mm 10 to 55 Hz at double amplitude of 5 mm Ambient temperature –40°C to 70°C –40°F to 158°F Humidity 5 to 85% R.H. Approx. 2 g .071 oz Remarks: * Specifications will vary with foreign standards certification ratings. *1 By nominal switching capacity: No. of operations: 107 *2 Measurement at same location as "Initial breakdown voltage" section. *3 Detection current: 10mA. *4 Nominal voltage applied to the coil, excluding contact bounce time. *5 By resistive method, nominal voltage applied to the coil; contact carrying current: 10mA. *6 Half-wave pulse of sine wave: 6 ms; detection time: 10µs. *7 Half-wave pulse of sine wave: 6 ms. *8 Detection time: 10µs. *9 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61) SX ORDERING INFORMATION Ex. ASX 2 Contact arrangement Operating function 2: 2 Form C 0 0 A 0: Standard type (B.B.M.) H Z Terminal shape Type of operation 0: Single side stable 1: 1 coil latching 2: 2 coil latching 1 Coil voltage (DC) Nil: Standard PC board terminal A: Surface-mount terminal 1H: 1.5V 03 : 3V 4H: 4.5V 06 : 6V 09 : 9V 12 : 12V 24 : 24V Packing style Nil: Tube packing Z: Tape and reel packing (piked from 8/9/10/12 pin side) Note: Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available. Suffix “X” instead of “Z”. TYPES AND COIL DATA (at 20°C 68°F) (1) Standard PC board terminal 1) Standard packing: 40 pcs. in an inner package (tube); 1,000 pcs. in an outer package 2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse. Single side stable Part No. Standard PC board terminal ASX2001H ASX20003 ASX2004H ASX20006 ASX20009 ASX20012 ASX20024 Coil Rating, V DC Pick-up voltage, V DC (max.) (initial) 1.5 3 4.5 6 9 12 24 1.2 2.4 3.6 4.8 7.2 9.6 19.2 Drop-out voltage, V DC (min.) (initial) 0.15 0.3 0.45 0.6 0.9 1.2 2.4 Coil Rating, V DC Set voltage, V DC (max.) (initial) 1.5 3 4.5 6 9 12 24 Coil Rating, V DC Nominal operating current, mA (±10%) Coil resistance, Ω (±10%) Nominal operating power, mW Max. allowable voltage, V DC 33.3 16.7 11.1 8.3 5.6 4.2 2.9 45 180 405 720 1,620 2,880 8,229 50 50 50 50 50 50 70 2.25 4.5 6.75 9 13.5 18 36 Reset voltage, V DC (max.) (initial) Nominal operating current, mA (±10%) Coil resistance, Ω (±10%) Nominal operating power, mW Max. allowable voltage, V DC 1.2 2.4 3.6 4.8 7.2 9.6 19.2 1.2 2.4 3.6 4.8 7.2 9.6 19.2 23.3 11.7 7.8 5.8 3.9 2.9 2.1 64.3 257 579 1,029 2,314 4,114 11,520 35 35 35 35 35 35 50 2.25 4.5 6.75 9 13.5 18 36 Set voltage, V DC (max.) (initial) Reset voltage, V DC (max.) (initial) 1.2 2.4 3.6 4.8 7.2 9.6 19.2 1.2 2.4 3.6 4.8 7.2 9.6 19.2 1 coil latching Part No. Standard PC board terminal ASX2101H ASX21003 ASX2104H ASX21006 ASX21009 ASX21012 ASX21024 2 coil latching Part No. Standard PC board terminal ASX2201H ASX22003 ASX2204H ASX22006 ASX22009 ASX22012 ASX22024 1.5 3 4.5 6 9 12 24 Nominal operating current, mA (±10%) Reset Set coil coil 46.7 46.7 23.3 23.3 15.6 15.6 11.7 11.7 7.8 7.8 5.8 5.8 6.3 6.3 Coil resistance, Ω (±10%) Set coil 32.1 129 289 514 1,157 2,057 3,840 Reset coil 32.1 129 289 514 1,157 2,057 3,840 Nominal operating power, mW Reset Set coil coil 70 70 70 70 70 70 70 70 70 70 70 70 150 150 Max. allowable voltage, V DC 2.25 4.5 6.75 9 13.5 18 36 121 SX (2) Surface-mount terminal 1) Standard packing: 40 pcs.(tube), 1,000pcs. (tape and reel)in an inner package; 500 pcs.(tube), 1,000pcs. (tape and reel)in an outer package 2) Specified value of pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse. Single side stable Part No. Tube packing Tape and reel packing ASX200A1H ASX200A03 ASX200A4H ASX200A06 ASX200A09 ASX200A12 ASX200A24 ASX200A1HZ ASX200A03Z ASX200A4HZ ASX200A06Z ASX200A09Z ASX200A12Z ASX200A24Z Pick-up voltage, V DC (max.) (initial) 1.2 2.4 3.6 4.8 7.2 9.6 19.2 Coil Rating, V DC 1.5 3 4.5 6 9 12 24 Drop-out voltage, V DC (min.) (initial) 0.15 0.3 0.45 0.6 0.9 1.2 2.4 Nominal operating current, mA (±10%) 33.3 16.7 11.1 8.3 5.6 4.2 2.9 Reset voltage, V DC (max.) (initial) 1.2 2.4 3.6 4.8 7.2 9.6 19.2 Nominal operating current, mA (±10%) 23.3 11.7 7.8 5.8 3.9 2.9 2.1 Coil resistance, Ω (±10%) 45 180 405 720 1,620 2,880 8,229 Nominal operating power, mW 50 50 50 50 50 50 70 Max. allowable voltage, V DC 2.25 4.5 6.75 9 13.5 18 36 Nominal operating power, mW 35 35 35 35 35 35 50 Max. allowable voltage, V DC 2.25 4.5 6.75 9 13.5 18 36 1 coil latching type Part No. Tube packing Tape and reel packing ASX210A1H ASX210A03 ASX210A4H ASX210A06 ASX210A09 ASX210A12 ASX210A24 ASX210A1HZ ASX210A03Z ASX210A4HZ ASX210A06Z ASX210A09Z ASX210A12Z ASX210A24Z Coil Rating, V DC Set voltage, V DC (max.) (initial) 1.5 3 4.5 6 9 12 24 1.2 2.4 3.6 4.8 7.2 9.6 19.2 Coil resistance, Ω (±10%) 64.3 257 579 1,029 2,314 4,114 11,520 2 coil latching type Part No. Tube packing ASX220A1H ASX220A03 ASX220A4H ASX220A06 ASX220A09 ASX220A12 ASX220A24 Coil Rating, V DC Tape and reel packing ASX220A1HZ ASX220A03Z ASX220A4HZ ASX220A06Z ASX220A09Z ASX220A12Z ASX220A24Z 1.5 3 4.5 6 9 12 24 Set voltage, V DC (max.) (initial) Reset voltage, V DC (max.) (initial) 1.2 2.4 3.6 4.8 7.2 9.6 19.2 1.2 2.4 3.6 4.8 7.2 9.6 19.2 Nominal operating current, mA (±10%) Set Reset coil coil 46.7 46.7 23.3 23.3 15.6 15.6 11.7 11.7 7.8 7.8 5.8 5.8 6.3 6.3 Nominal operating power, mW Set Reset coil coil 70 70 70 70 70 70 70 70 70 70 70 70 150 150 Coil resistance, Ω (±10%) Set coil 32.1 129 289 514 1,157 2,057 3,840 Reset coil 32.1 129 289 514 1,157 2,057 3,840 Max. allowable voltage, V DC 2.25 4.5 6.75 9 13.5 18 36 DIMENSIONS mm inch 1. PC board terminal PC board pattern 7.4 .291 15.0 .591 Single side stable/ 1 coil latching 0.5 .020 1.15 .045 2.54 .100 0.65 8.2 .026 .323 5.08 .200 2.54 .100 3.5 .138 Schematic (Bottom view) Single side stable (Deenergized condition) 10.16 .400 1 3 4 5 12 10 9 8 1 coil latching (Reset condition) 2 coil latching 0.25 .010 8-1.0 dia. 8-.039 dia. 5.08 .200 7.4 .291 5.08 .200 2.54 .100 3.5 .138 General tolerance: ±0.3 ±.012 122 2.54 .100 0.65 8.2 .026 .323 0.5 .020 1.15 .045 3 4 5 12 10 9 8 5.08 .200 Direction indication Direction indication 2 coil latching (Reset condition) 15.0 .591 1 12.7 .500 5.08 .200 0.25 .010 5.08 .200 10-1.0 dia. 10-.039 dia. Tolerance: ±0.1 ±.004 1 3 4 5 6 12 10 9 8 7 Direction indication SX 2. Surface-mount terminal mm inch Suggested mounting pad 15.0 .591 7.4 .291 Single side stable/ 1 coil latching 0.5 .020 1.15 .045 5.08 .200 5.08 .200 1.0 .039 , ,,,,,,,,,,,,, ,,,,,,,,, ,,,,,,,, ,,,,,, , 8.2 .323 Max.10.0 .394 0.65 .026 2.54 .100 Schematic (Top view) Single side stable (Deenergized condition) 0.25 .010 5.08 .200 10 9 8 1 3 4 5 12 10 9 8 1 3 4 5 2.54 .100 7.24 .285 3.16 .124 9.4±0.5 .370±.020 12 1 coil latching (Reset condition) Direction indication Direction indication 2 coil latching (Reset condition) 15.0 .591 7.4 .291 2 coil latching 0.5 .020 1.15 .045 5.08 .200 5.08 .200 Max.10.0 .394 0.65 .026 2.54 .100 1.0 .039 0.25 .010 5.08 .200 7.24 .285 3.16 .124 9.4±0.5 .370±.020 General tolerance: ±0.3 ±.012 12 10 9 8 7 1 3 4 5 6 2.54 .100 ,,,,,,,, ,,,,,,,,,,, ,,,, ,,,,,,,,,,,,,,,, ,, 8.2 .323 Direction indication Tolerance: ±0.1 ±.004 REFERENCE DATA 2-(1). Change in dynamic contact resistance (10 mA 10 V DC resistive load) 2-(2). Change in dynamic contact resistance (10 µA 1 mV DC resistive load) Tested: ASX20012, Quantity: n=10 Operating frequency: 750 cpm Measured condition: 10 ms after applying nominal coil voltage, using voltage drop of 20 mV, 1 mA, 1 kHz. Tested: ASX20012, Quantity: n=10 Operating frequency: 750 cpm Measured condition: 10 ms after applying nominal coil voltage, using voltage drop of 20 mV, 1 mA, 1 kHz. 10mA 1.0 1.0 0.9 0.9 Contact resistance, Ω Contact resistance, Ω Contact current 1. Switching capacity range 0.8 0.7 0.6 0.5 0.4 0.3 0 10V Contact voltage Max. Min. 1,000 0 No. of operations, × 104 3-(1). Change in static contact resistance (10 mA 10 V DC resistive load) 3-(2). Change in static contact resistance (10 µA 1 mVDC resistive load) Tested: ASX20012, Quantity: n=10 Operating frequency: 750 cpm Tested: ASX20012, Quantity: n=10 Operating frequency: 750 cpm 80 70 60 50 Max. Min. Max. Min. 40 30 0.4 0.1 0 0 Max. Min. 2,000 1,000 No. of operations, × 104 80 70 60 50 30 20 10 1,000 No. of operations, × 10 4 Max. Min. Max. Min. 40 10 0 N.C. side contact N.O. side contact 90 20 0 0.5 100 N.C. side contact N.O. side contact 90 Contact resistance, mΩ Contact resistance, mΩ 100 0.6 0.2 0.1 1mV 0.7 0.3 0.2 10µA 0.8 0 0 1,000 2,000 No. of operations, × 104 123 SX NOTES 5. Packing style 1) The relay is packed in a tube with the relay orientation mark on the left side, as shown in the figure below. Orientation (indicates PIN No.1)stripe 6. Automatic insertion To maintain the internal function of the relay, the chucking pressure should not exceed the values below. Chucking pressure in the direction A: 4.9 N {500 gf} or less Chucking pressure in the direction B: 9.8 N {1 kgf} or less Chucking pressure in the direction C: 9.8 N {1 kgf} or less , 1. Coil operating power 1) As a general rule, only a pure DC power supply should be used for the coil drive. 2) To ensure proper operation, the voltage applied to both terminals of the coil should be ±5% (at 20°C 68°F) the rated operating voltage of the coil. Also, be aware that the pick-up and drop-out voltages will fluctuate depending on the ambient temperature and operating conditions. 3) The ripple factor for the voltage applied to the coil should be less than 5%. 4) For set and reset latching relays, the rated operating voltage should be applied to the coil for 10 ms or more. 2. Coil connection When connecting coils, refer to the wiring diagram to prevent mis-operation or malfunction. 3. External magnetic field Since SX relays are highly sensitive polarized relays, their characteristics will be affected by a strong external magnetic field. Avoid using the relay under that condition. 4. Cleaning In automatic cleaning, cleaning with the boiling method is recommended. Avoid ultrasonic cleaning which subject the relay to high frequency vibrations. It may cause the contacts to stick. lt is recommended that a fluorinated hydrocarbon or other alcoholic solvent be used. Stopper (gray) Stopper (green) 2) Tape and reel packing (1) Tape dimensions Relay polarity bar (Z type) 1.50 +0.1 0 dia. mm inch 15.5±0.1 .610±.004 SX relays B 1.75±0.1 .069±.004 2.0±0.1 .079±.004 Max. 20.0 .787 10.8±0.2 .425±.008 C 4.0±0.1 .157±.004 .059 +.003 .0 dia. 0.40±0.1 .016±.004 A 16.0±0.1 .630±.004 10.0±0.1 .394±.004 24.0±0.3 .945±.012 11.5±0.1 .453±.004 Tape coming out direction General tolerance ±0.1 mm .004 inch (2) Dimensions of plastic reel mm inch Please chuck the portion. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be also avoided. 21±0.8 dia. .827±.031 dia. 2.0±0.5 .079±.020 100±1 dia. 3.937±.039 dia. 370±2 dia. 14.567±.079 dia. 13±0.2 dia. .512±.008 dia. 24.4 +2 0 .961 +.079 0 2.0±0.2 .079±.008 For Cautions for Use, see Relay Technical Information (Page 48 to 76). 124 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog