ATMEL AT49BV320C-70TI

Features
• Single Voltage Read/Write Operation: 2.65V to 3.6V
• Access Time – 70 ns
• Sector Erase Architecture
•
•
•
•
•
•
•
•
•
•
•
•
•
– Sixty-three 32K Word (64K Bytes) Sectors with Individual Write Lockout
– Eight 4K Word (8K Bytes) Sectors with Individual Write Lockout
Fast Word Program Time – 12 µs
Fast Sector Erase Time – 300 ms
Suspend/Resume Feature for Erase and Program
– Supports Reading and Programming from Any Sector by Suspending Erase
of a Different Sector
– Supports Reading Any Word by Suspending Programming of Any Other Word
Low-power Operation
– 12 mA Active
– 13 µA Standby
VPP Pin for Write Protection
WP Pin for Sector Protection
RESET Input for Device Initialization
Flexible Sector Protection
TSOP and CBGA Package Options
Top or Bottom Boot Block Configuration Available
128-bit Protection Register
Minimum 100,000 Erase Cycles
Common Flash Interface (CFI)
32-megabit
(2M x 16)
3-volt Only
Flash Memory
AT49BV320C
AT49BV320CT
Description
The AT49BV320C(T) is a 2.7-volt 32-megabit Flash memory organized as 2,097,152
words of 16 bits each. The memory is divided into 71 sectors for erase operations.
The device is offered in a 48-lead TSOP and a 47-ball CBGA package. The device has
CE and OE control signals to avoid any bus contention. This device can be read or
reprogrammed using a single power supply, making it ideally suited for in-system
programming.
Pin Configurations
Pin Name
Function
A0 - A20
Addresses
CE
Chip Enable
OE
Output Enable
WE
Write Enable
RESET
Reset
VPP
Write Protection
I/O0 - I/O15
Data Inputs/Outputs
NC
No Connect
VCCQ
Output Power Supply
WP
Write Protect
Rev. 3372D–FLASH–5/04
1
TSOP Top View
Type 1
A15
A14
A13
A12
A11
A10
A9
A8
NC
A20
WE
RESET
VPP
WP
A19
A18
A17
A7
A6
A5
A4
A3
A2
A1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
CBGA Top View
48
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
A16
VCCQ
GND
I/O15
I/O7
I/O14
I/O6
I/O13
I/O5
I/O12
I/O4
VCC
I/O11
I/O3
I/O10
I/O2
I/O9
I/O1
I/O8
I/O0
OE
GND
CE
A0
1
2
3
4
5
6
7
8
A13
A11
A8
VPP
WP
A19
A7
A4
A14
A10
WE
RST
A18
A17
A5
A2
A15
A12
A9
A20
A6
A3
A1
A16
I/O14
I/O5
I/O11
I/O2
I/O8
CE
A0
VCCQ I/O15
I/O6
I/O12
I/O3
I/O9
I/O0
GND
I/O7
I/O13
I/O4
VCC
I/O10
I/O1
OE
A
B
C
D
E
F
GND
The device powers on in the read mode. Command sequences are used to place the device in
other operation modes such as program and erase. The device has the capability to protect
the data in any sector (see Flexible Sector Protection section).
To increase the flexibility of the device, it contains an Erase Suspend and Program Suspend
feature. This feature will put the erase or program on hold for any amount of time and let the
user read data from or program data to any of the remaining sectors within the memory.
The VPP pin provides data protection. When the VPP input is below 0.4V, the program and
erase functions are inhibited. When VPP is at 1.5V or above, normal program and erase operations can be performed.
2
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
Block Diagram
I/O0 - I/O15
INPUT
BUFFER
INPUT
BUFFER
IDENTIFIER
REGISTER
STATUS
REGISTER
DATA
REGISTER
A0 - A20
OUTPUT
MULTIPLEXER
OUTPUT
BUFFER
CE
WE
OE
RESET
WP
COMMAND
REGISTER
ADDRESS
LATCH
DATA
COMPARATOR
Y-DECODER
Y-GATING
WRITE STATE
MACHINE
PROGRAM/ERASE
VOLTAGE SWITCH
VPP
VCC
GND
X-DECODER
MAIN
MEMORY
3
3372D–FLASH–5/04
Device
Operation
READ: When the AT49BV320C(T) is in the read mode, with CE and OE low and WE high, the
data stored at the memory location determined by the address pins are asserted on the outputs. The outputs are put in the high impedance state whenever CE or OE is high. This dualline control gives designers flexibility in preventing bus contention.
COMMAND SEQUENCES: When the device is first powered on, it will be in the read mode. In
order to perform other device functions, a series of command sequences are entered into the
device. The command sequences are shown in the “Command Definition” table on page 15
(I/O8 - I/O15 are don’t care inputs for the command codes). The command sequences are
written by applying a low pulse on the WE or CE input with CE or WE low (respectively) and
OE high. The address and data are latched by the first rising edge of CE or WE. Standard
microprocessor write timings are used. The address locations used in the command
sequences are not affected by entering the command sequences.
RESET: A RESET input pin is provided to ease some system applications. When RESET is at
a logic high level, the device is in its standard operating mode. A low level on the RESET input
halts the present device operation and puts the outputs of the device in a high impedance
state. When a high level is reasserted on the RESET pin, the device returns to the read mode,
depending upon the state of the control inputs.
ERASURE: Before a word can be reprogrammed, it must be erased. The erased state of
memory bits is a logical “1”. The individual sectors can be erased by using the Sector Erase
command.
SECTOR ERASE: The device is organized into 71 sectors (SA0 - SA70) that can be individually erased. The Sector Erase command is a two-bus cycle operation. The sector address and
the D0H Data Input command are latched on the rising edge of WE. The sector erase starts
after the rising edge of WE of the second cycle provided the given sector has not been protected. The erase operation is internally controlled; it will automatically time to completion. The
maximum time to erase a sector is tSEC. An attempt to erase a sector that has been protected
will result in the operation terminating immediately.
WORD PROGRAMMING: Once a memory sector is erased, it is programmed (to a logical “0”)
on a word-by-word basis. Programming is accomplished via the Internal Device command register and is a two-bus cycle operation. The device will automatically generate the required
internal program pulses.
Any commands written to the chip during the embedded programming cycle will be ignored. If
a hardware reset happens during programming, the data at the location being programmed
will be corrupted. Please note that a data “0” cannot be programmed back to a “1”; only erase
operations can convert “0”s to “1”s. Programming is completed after the specified tBP cycle
time. If the program status bit is a “1”, the device was not able to verify that the program operation was performed successfully. The status register indicates the programming status. While
the program sequence executes, status bit I/O7 is “0”. While programming, the only valid commands are Read Status Register, Program Suspend and Program Resume.
VPP PIN: The circuitry of the AT49BV320C(T) is designed so that the device cannot be programmed or erased if the VPP voltage is less that 0.4V. When VPP is at 1.5V or above, normal
program and erase operations can be performed. The VPP pin cannot be left floating.
READ STATUS REGISTER: The status register indicates the status of device operations and
the success/failure of that operation. The Read Status Register command causes subsequent
reads to output data from the status register until another command is issued. To return to
reading from the memory, issue a Read command.
The status register bits are output on I/O7 - I/O0. The upper byte, I/O15 - I/O8, outputs 00H
when a Read Status Register command is issued.
4
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
The contents of the status register [SR7:SR0] are latched on the falling edge of OE or CE
(whichever occurs last), which prevents possible bus errors that might occur if status register
contents change while being read. CE or OE must be toggled with each subsequent status
read, or the status register will not indicate completion of a Program or Erase operation.
When the Write State Machine (WSM) is active, SR7 will indicate the status of the WSM; the
remaining bits in the status register indicate whether the WSM was successful in performing
the preferred operation (see Table 1).
Table 1. Status Register Bit Definition
WSMS
ESS
ES
PS
VPPS
PSS
SLS
R
7
6
5
4
3
2
1
0
Notes
SR7 WRITE STATE MACHINE STATUS (WSMS)
1 = Ready
0 = Busy
Check Write State Machine bit first to determine Word Program
or Sector Erase completion, before checking program or erase
status bits.
SR6 = ERASE SUSPEND STATUS (ESS)
1 = Erase Suspended
0 = Erase In Progress/Completed
When Erase Suspend is issued, WSM halts execution and sets
both WSMS and ESS bits to “1” – ESS bit remains set to “1” until
an Erase Resume command is issued.
SR5 = ERASE STATUS (ES)
1 = Error in Sector Erase
0 = Successful Sector Erase
When this bit is set to “1”, WSM has applied the max number of
erase pulses to the sector and is still unable to verify successful
sector erasure.
SR4 = PROGRAM STATUS (PS)
1 = Error in Programming
0 = Successful Programming
When this bit is set to “1”, WSM has attempted but failed to
program a word
SR3 = VPP STATUS (VPPS)
1 = VPP Low Detect, Operation Abort
0 = VPP OK
The VPP status bit does not provide continuous indication of VPP
level. The WSM interrogates VPP level only after the Program or
Erase command sequences have been entered and informs the
system if VPP has not been switched on. The VPP is also checked
before the operation is verified by the WSM.
SR2 = PROGRAM SUSPEND STATUS (PSS)
1 = Program Suspended
0 = Program in Progress/Completed
When Program Suspend is issued, WSM halts execution and
sets both WSMS and PSS bits to “1”. PSS bit remains set to “1”
until a Program Resume command is issued.
SR1 = SECTOR LOCK STATUS
1 = Prog/Erase attempted on a locked sector; Operation aborted.
0 = No operation to locked sectors
If a Program or Erase operation is attempted to one of the locked
sectors, this bit is set by the WSM. The operation specified is
aborted and the device is returned to read status mode.
SR0 = RESERVED FOR FUTURE ENHANCEMENTS (R)
This bit is reserved for future use and should be masked out
when polling the status register.
Note:
1. A Command Sequence Error is indicated when SR1, SR3, SR4 and SR5 are set.
5
3372D–FLASH–5/04
CLEAR STATUS REGISTER: The WSM can set status register bits 1 through 7 and can clear
bits 2, 6 and 7; but, the WSM cannot clear status register bits 1, 3, 4 or 5. Because bits 1, 3, 4
and 5 indicate various error conditions, these bits can be cleared only through the Clear Status
Register command. By allowing the system software to control the resetting of these bits, several operations may be performed (such as cumulatively programming several addresses or
erasing multiple sectors in sequence) before reading the status register to determine if an
error occurred during those operations. The status register should be cleared before beginning
another operation. The Read command must be issued before data can be read from the
memory array. The status register can also be cleared by resetting the device.
FLEXIBLE SECTOR PROTECTION: The AT49BV320C(T) offers two sector protection
modes, the Softlock and the Hardlock. The Softlock mode is optimized as sector protection for
sectors whose content changes frequently. The Hardlock protection mode is recommended
for sectors whose content changes infrequently. Once either of these two modes is enabled,
the contents of the selected sector is read-only and cannot be erased or programmed. Each
sector can be independently programmed for either the Softlock or Hardlock sector protection
mode. At power-up and reset, all sectors have their Softlock protection mode enabled.
SOFTLOCK AND UNLOCK: The Softlock protection mode can be disabled by issuing a twobus cycle Unlock command to the selected sector. Once a sector is unlocked, its contents can
be erased or programmed. To enable the Softlock protection mode, a two-bus cycle Softlock
command must be issued to the selected sector.
HARDLOCK AND WRITE PROTECT: The Hardlock sector protection mode operates in conjunction with the Write Protect (WP) pin. The Hardlock sector protection mode can be enabled
by issuing a two-bus cycle Hardlock Software command to the selected sector. The state of
the Write Protect pin affects whether the Hardlock protection mode can be overridden.
•
When the WP pin is low and the Hardlock protection mode is enabled, the sector cannot
be unlocked and the contents of the sector is read-only.
•
When the WP pin is high, the Hardlock protection mode is overridden and the sector can
be unlocked via the Unlock command.
To disable the Hardlock sector protection mode, the chip must be either reset or power cycled.
6
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
Table 2. Hardlock and Softlock Protection Configurations in Conjunction with WP
WP
Hardlock
Softlock
Erase/
Prog
Allowed?
VCC/5V
0
0
0
Yes
No sector is locked
VCC/5V
0
0
1
No
Sector is Softlocked. The Unlock
command can unlock the sector.
VCC/5V
0
1
1
No
Hardlock protection mode is enabled. The
sector cannot be unlocked.
VCC/5V
1
0
0
Yes
No sector is locked.
VCC/5V
1
0
1
No
Sector is Softlocked. The Unlock
command can unlock the sector.
VCC/5V
1
1
0
Yes
Hardlock protection mode is overridden
and the sector is not locked.
VCC/5V
1
1
1
No
Hardlock protection mode is overridden
and the sector can be unlocked via the
Unlock command.
VIL
x
x
x
No
Erase and Program Operations cannot be
performed.
VPP
Comments
Figure 1. Sector Locking State Diagram
UNLOCKED
LOCKED
60h/
D0h
60h/01h
[000]
[001]
60
h/2
Fh
Power-Up/Reset
Default
60h/
2Fh
WP = VIL = 0
[011]
60h/D0h
[110]
60h/
01h
60h/
D0h
[100]
Hardlocked is disabled by
WP = VIH
[111]
60h/
2Fh
WP = VIH = 1
Hardlocked
60h/
2Fh
Power-Up/Reset
Default
60h/
01h
[101]
60h/D0h = Unlock Command
60h/01h = Softlock Command
60h/2Fh = Hardlock Command
Notes:
1. The notation [X, Y, Z] denotes the locking state of a sector. The current locking state of a sector is defined by the state of WP
and the two bits of the sector-lock status D[1:0].
7
3372D–FLASH–5/04
SECTOR PROTECTION DETECTION: A software method is available to determine if the sector protection Softlock or Hardlock features are enabled. When the device is in the software
product identification mode, a read from the I/O0 and I/O1 at address location 00002H within a
sector will show if the sector is unlocked, softlocked, or hardlocked.
Table 3. Sector Protection Status
I/O1
I/O0
Sector Protection Status
0
0
Sector Not Locked
0
1
Softlock Enabled
1
0
Hardlock Enabled
1
1
Both Hardlock and Softlock Enabled
ERASE SUSPEND/ERASE RESUME: The Erase Suspend command allows the system to
interrupt a sector erase operation and then program or read data from a different sector within
the memory. After the Erase Suspend command is given, the device requires a maximum time
of 15 µs to suspend the erase operation. After the erase operation has been suspended, the
system can then read data or program data to any other sector within the device. An address
is not required during the Erase Suspend command. During a sector erase suspend, another
sector cannot be erased. To resume the sector erase operation, the system must write the
Erase Resume command. The Erase Resume command is a one-bus cycle command. The
only valid commands while erase is suspended are Read Status Register, Product ID Entry,
CFI Query, Program, Program Resume, Erase Resume, Sector Softlock/Hardlock, Sector
Unlock.
PROGRAM SUSPEND/PROGRAM RESUME: The Program Suspend command allows the
system to interrupt a programming operation and then read data from a different word within
the memory. After the Program Suspend command is given, the device requires a maximum
of 20 µs to suspend the programming operation. After the programming operation has been
suspended, the system can then read data from any other word within the device. An address
is not required during the program suspend operation. To resume the programming operation,
the system must write the Program Resume command. The program suspend and resume are
one-bus cycle commands. The command sequence for the erase suspend and program suspend are the same and the command sequence for the erase resume and program resume
are the same. The only other valid commands while program is suspended are Read Status
Register, Product ID Entry, CFI Query and Program Resume.
PRODUCT IDENTIFICATION: The product identification mode identifies the device and manufacturer as Atmel. It may be accessed by a software operation. For details, see “Operating
Modes” on page 21.
128-BIT PROTECTION REGISTER: The AT49BV320C(T) contains a 128-bit register that can
be used for security purposes in system design. The protection register is divided into two 64bit sectors. The two sectors are designated as sector A and sector B. The data in sector A is
non-changeable and is programmed at the factory with a unique number. The data in sector B
is programmed by the user and can be locked out such that data in the sector cannot be reprogrammed. To program sector B in the protection register, the two-bus cycle Program
Protection Register command must be used as shown in the “Command Definition” table on
page 15. To lock out sector B, the two-bus cycle Lock Protection Register command must be
used as shown in the “Command Definition” table. Data bit D1 must be zero during the second
bus cycle. All other data bits during the second bus cycle are don’t cares. To determine
whether sector B is locked out, use the status of sector B protection command. If data bit D1 is
zero, sector B is locked. If data bit D1 is one, sector B can be reprogrammed. Please see the
“Protection Register Addressing Table” on page 16 for the address locations in the protection
8
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
register. To read the protection register, the Product ID Entry command is given followed by a
normal read operation from an address within the protection register. After determining
whether sector B is protected or not, or reading the protection register, the Read command
must be given to return to the read mode.
CFI: Common Flash Interface (CFI) is a published, standardized data structure that may be
read from a flash device. CFI allows system software to query the installed device to determine the configurations, various electrical and timing parameters and functions supported by
the device. CFI is used to allow the system to learn how to interface to the flash device most
optimally. The two primary benefits of using CFI are ease of upgrading and second source
availability. The command to enter the CFI Query mode is a one-bus cycle command which
requires writing data 98h to any address. The CFI Query command can be written when the
device is ready to read data or can also be written when the part is in the product ID mode.
Once in the CFI Query mode, the system can read CFI data at the addresses given in Table 4
on page 27. To return to the read mode, issue the Read command.
HARDWARE DATA PROTECTION: The Hardware Data Protection feature protects against
inadvertent programs to the AT49BV320C(T) in the following ways: (a) VCC sense: if VCC is
below 1.8V (typical), the program function is inhibited. (b) VCC power-on delay: once VCC has
reached the VCC sense level, the device will automatically time out 10 ms (typical) before programming. (c) Program inhibit: holding any one of OE low, CE high or WE high inhibits
program cycles. (d) Program inhibit: VPP is less than VILPP. (e) VPP power-on delay: once VPP
has reached 0.9V, program and erase operations are inhibited for 100 ns.
INPUT LEVELS: While operating with a 2.65V to 3.6V power supply, the address inputs and
control inputs (OE, CE and WE) may be driven from 0 to 5.5V without adversely affecting the
operation of the device. The I/O lines can only be driven from 0 to VCCQ + 0.6V.
OUTPUT LEVELS: For the AT49BV320C(T), output high levels (VOH) are equal to VCCQ - 0.1V
(not VCC). For 2.65V - 3.6V output levels, VCCQ must be tied to VCC. For 1.8V - 2.2V output levels, VCCQ must be regulated to 2.0V ± 10%, while VCC must be regulated to 2.65V - 3.0V (for
minimum power).
9
3372D–FLASH–5/04
Word Program Flowchart
Word Program Procedure
Bus
Operation
Start
Write 40,
Word Address
(Setup)
Write Data,
Word Address
(Confirm)
Program
Suspend
Loop
Read Status
Register
Command
Write
Program
Setup
Data = 40
Addr = Location to program
Write
Data
Data = Data to program
Addr = Location to program
Read
None
Status register data: Toggle CE or
OE to update status register
Idle
None
Check SR7
1 = WSM Ready
0 = WSM Busy
No
0
SR7 =
Suspend?
Yes
1
Full Status
Check
(If Desired)
Comments
Repeat for subsequent Word Program operations.
Full status register check can be done after each program, or after a
sequence of program operations.
Write FF after the last operation to set to the Read state.
Program
Complete
Full Status Check Flowchart
Read Status
Register
SR3 =
1
VP P Range
Error
Full Status Check Procedure
Bus
Operation
Command
Idle
None
Check SR3:
1 = VPP Error
Idle
None
Check SR4:
1 = Data Program Error
Idle
None
Check SR1:
1 = Sector locked; operation aborted
0
SR4 =
1
Program
Error
0
SR1 =
1
Device
Protect Error
Comments
SR3 MUST be cleared before the Write State Machine allows further program
attempts.
If an error is detected, clear the status register before continuing operations –
only the Clear Status Register command clears the status register error bits.
0
Program
Successful
10
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
Program Suspend/Resume Flowchart
Bus
Operation
Start
Write B0
Any Address
(Program Suspend)
Write 70
Any Address
(Read Status)
Read Status
Register
SR7 =
Program Suspend/Resume Procedure
Command
Write
Read
Status
Data = 70
Addr = Any address
Write
Program
Suspend
Data = B0
Addr = Any address
Read
None
Status register data: Toggle CE or
OE to update status register
Addr = Any address
Idle
None
Check SR7
1 = WSM Ready
0 = WSM Busy
Idle
None
Check SR2
1 = Program suspended
0 = Program completed
Write
Read Array
Read
None
Write
Program
Resume
0
1
SR2 =
0
Program
Completed
1
Write FF
Data = FF
Addr = Any address
Read data from any word in the memory
(Read Array)
Read
Data
Done
Reading
Comments
Write FF
No
Data = D0
Addr = Any address
(Read
Array)
Read
Data
Yes
Write D0
Any Address
(Program Resume)
Program
Resumed
11
3372D–FLASH–5/04
Erase Suspend/Resume Flowchart
Bus
Operation
Start
Write B0,
Any Address
(Erase Suspend)
Write 70,
Any Address
(Read Status)
Read Status
Register
SR7 =
Erase Suspend/Resume Procedure
0
Command
Write
Read
Status
Data = 70
Addr = Any address
Write
Erase
Suspend
Data = B0
Addr = Any address
Read
None
Status register data: Toggle CE or
OE to update status register
Addr = Any address
Idle
None
Check SR7
1 = WSM Ready
0 = WSM Busy
Idle
None
Check SR6
1 = Erase suspended
0 = Erase completed
Write
Read or
Program
Read or
Write
None
Write
Program
Resume
1
SR6 =
0
Erase
Completed
1
Write FF
(Read Array)
Read
Data
Done
Reading
0
1
(Erase Resume)
12
Write D0,
Any Address
Write FF
Erase
Resumed
Read Array
Data
Comments
Data = FF or 40
Addr = Any address
Read or program data from/to sector other
than the one being erased
Data = D0
Addr = Any address
(Read Array)
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
Sector Erase Procedure
Sector Erase Flowchart
Bus
Operation
Start
Write 20,
Sector Address
Suspend
Erase
Loop
Read Status
Register
Comments
Write
Sector
Erase
Setup
Data = 20
Addr = Sector to be erased (SA)
Write
Erase
Confirm
Data = D0
Addr = Sector to be erased (SA)
Read
None
Status register data: Toggle CE or
OE to update status register data
Idle
None
Check SR7
1 = WSM Ready
0 = WSM Busy
(Sector Erase)
Write D0,
(Erase Confirm)
Sector Address
Command
No
Suspend
Erase
0
SR7 =
Yes
1
Full Erase
Status Check
(If Desired)
Repeat for subsequent sector erasures.
Full status register check can be done after each sector erase, or after a
sequence of sector erasures.
Write FF after the last operation to enter read mode.
Sector Erase
Complete
Full Erase Status Check Flowchart
Read Status
Register
SR3 =
1
VP P Range
Error
Full Erase Status Check Procedure
Bus
Operation
Command
Idle
None
Check SR3:
1 = VPP Range Error
Idle
None
Check SR4, SR5:
Both 1 = Command Sequence Error
Idle
None
Check SR5:
1 = Sector Erase Error
Idle
None
Check SR1:
1 = Attempted erase of locked sector;
erase aborted.
Comments
0
SR4, SR5 =
1,1
Command
Sequence Error
0
SR5 =
1
Sector Erase
Error
1
Sector Locked
Error
0
SR1 =
0
Sector Erase
Successful
SR1, SR3 must be cleared before the Write State Machine allows further
erase attempts.
Only the Clear Status Register command clears SR1, SR3, SR4, SR5.
If an error is detected, clear the status register before attempting an
erase retry or other error recovery.
13
3372D–FLASH–5/04
Protection Register Programming
Flowchart
Protection Register Programming Procedure
Bus
Operation
Command
Comments
Start
Write C0,
PR Address
Write PR
Address & Data
(Confirm Data)
Full Status
Check
(If Desired)
Program
Complete
Full Status Check Flowchart
Read Status
Register Data
1
Protection
Program
Data = Data to Program
Addr = Location to Program
Read
None
Status register data: Toggle CE or
OE to update status register data
Idle
None
Check SR7
1 = WSM Ready
0 = WSM Busy
Full Status Check Procedure
Bus
Operation
Command
Idle
None
Check SR1, SR3, SR4:
0,1,1 = VPP Range Error
Idle
None
Check SR1, SR3, SR4:
0,0,1 = Programming Error
Idle
None
Check SR1, SR3, SR4:
1, 0,1 = Sector locked; operation
aborted
VP P Range Error
0
1
Program Error
1
Register Locked;
Program Aborted
0
0
Program
Successful
14
Write
Program Protection Register operation addresses must be within the
protection register address space. Addresses outside this space will
return an error.
Repeat for subsequent programming operations.
Full status register check can be done after each program, or after a
sequence of program operations.
Write FF after the last operation to return to the Read mode.
1
SR3, SR4 =
Data = C0
Addr = First Location to Program
0
SR7 =
SR3, SR4 =
Program
PR Setup
(Program Setup)
Read Status
Register
SR3, SR4 =
Write
Comments
SR3 must be cleared before the Write State Machine allows further
program attempts.
Only the Clear Status Register command clears SR1, SR3, SR4.
If an error is detected, clear the status register before attempting a
program retry or other error recovery.
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
Command Definition in Hex(1)
Command
Sequence
1st Bus
Cycle
2nd Bus
Cycle
Bus
Cycles
Addr
Data
Read
1
XX
FF
Sector Erase/Confirm
2
XX
Word Program
2
XX
Addr
Data
20
SA(2)
D0
40/10
Addr
DIN
01
Erase/Program Suspend
1
XX
B0
Erase/Program Resume
1
XX
D0
Product ID Entry
1
XX
90
Sector Softlock
2
XX
60
SA(2)
(2)
2F
Sector Hardlock
2
XX
60
SA
Sector Unlock
2
XX
60
SA(2)
D0
Read Status Register
2
XX
70
XX
DOUT(3)
Clear Status Register
1
XX
50
Program Protection Register
2
XX
C0
Addr
DIN
Lock Protection Register – Sector B
2
XX
C0
80
FFFD
Status of Sector B Protection
2
XX
90
80
DOUT(4)
CFI Query
1
XX
98
Notes:
1. The DATA FORMAT shown for each bus cycle is as follows; I/O7 - I/O0 (Hex). I/O15 - I/O8 are don’t care. The ADDRESS
FORMAT shown for each bus cycle is as follows: A7 - A0 (Hex). Address A20 through A8 are don’t care.
2. SA = sector address. Any word address within a sector can be used to designate the sector address (see pages 17 and 18
for details).
3. The status register bits are output on I/O7 - I/O0.
4. If data bit D1 is “0”, sector B is locked. If data bit D1 is “1”, sector B can be reprogrammed.
Absolute Maximum Ratings*
Temperature under Bias ................................ -55°C to +125°C
Storage Temperature ..................................... -65°C to +150°C
All Input Voltages
(including NC Pins)
with Respect to Ground ...................................-0.6V to +6.25V
All Output Voltages
with Respect to Ground .............................-0.6V to VCC + 0.6V
*NOTICE:
Stresses beyond those listed under “Absolute
Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or any
other conditions beyond those indicated in the
operational sections of this specification is not
implied. Exposure to absolute maximum rating
conditions for extended periods may affect device
reliability.
Voltage on VPP
with Respect to Ground ...................................-0.6V to +13.0V
15
3372D–FLASH–5/04
Protection Register Addressing Table
Word
Use
Sector
A7
A6
A5
A4
A3
A2
A1
A0
0
Factory
A
1
0
0
0
0
0
0
1
1
Factory
A
1
0
0
0
0
0
1
0
2
Factory
A
1
0
0
0
0
0
1
1
3
Factory
A
1
0
0
0
0
1
0
0
4
User
B
1
0
0
0
0
1
0
1
5
User
B
1
0
0
0
0
1
1
0
6
User
B
1
0
0
0
0
1
1
1
User
B
1
0
0
0
1
0
0
0
7
Note:
16
All address lines not specified in the above table must be “0” when accessing the protection register, i.e., A20 - A8 = 0.
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
AT49BV320C – Sector Address Table
Sector
Size (Bytes/Words)
Address Range (A20 - A0)
SA0
8K/4K
00000 - 00FFF
SA1
8K/4K
01000 - 01FFF
SA2
8K/4K
02000 - 02FFF
SA3
8K/4K
03000 - 03FFF
SA4
8K/4K
04000 - 04FFF
SA5
8K/4K
05000 - 05FFF
SA6
8K/4K
06000 - 06FFF
SA7
8K/4K
07000 - 07FFF
SA8
64K/32K
08000 - 0FFFF
SA9
64K/32K
10000 - 17FFF
SA10
64K/32K
18000 - 1FFFF
SA11
64K/32K
20000 - 27FFF
SA12
64K/32K
28000 - 2FFFF
SA13
64K/32K
30000 - 37FFF
SA14
64K/32K
38000 - 3FFFF
SA15
64K/32K
40000 - 47FFF
SA16
64K/32K
48000 - 4FFFF
SA17
64K/32K
50000 - 57FFF
SA18
64K/32K
58000 - 5FFFF
SA19
64K/32K
60000 - 67FFF
SA20
64K/32K
68000 - 6FFFF
SA21
64K/32K
70000 - 77FFF
SA22
64K/32K
78000 - 7FFFF
SA23
64K/32K
80000 - 87FFF
SA24
64K/32K
88000 - 8FFFF
SA25
64K/32K
90000 - 97FFF
SA26
64K/32K
98000 - 9FFFF
SA27
64K/32K
A0000 - A7FFF
SA28
64K/32K
A8000 - AFFFF
SA29
64K/32K
B0000 - B7FFF
SA30
64K/32K
B8000 - BFFFF
SA31
64K/32K
C0000 - C7FFF
SA32
64K/32K
C8000 - CFFFF
SA33
64K/32K
D0000 - D7FFF
SA34
64K/32K
D8000 - DFFFF
SA35
64K/32K
E0000 - E7FFF
SA36
64K/32K
E8000 - EFFFF
SA37
64K/32K
F0000 - F7FFF
17
3372D–FLASH–5/04
AT49BV320C – Sector Address Table (Continued)
Sector
Size (Bytes/Words)
Address Range (A20 - A0)
SA38
64K/32K
F8000 - FFFFF
SA39
64K/32K
100000 - 107FFF
SA40
64K/32K
108000 - 10FFFF
SA41
64K/32K
110000 - 117FFF
SA42
64K/32K
118000 - 11FFFF
SA43
64K/32K
120000 - 127FFF
SA44
64K/32K
128000 - 12FFFF
SA45
64K/32K
130000 - 137FFF
SA46
64K/32K
138000 - 13FFFF
SA47
64K/32K
140000 - 147FFF
SA48
64K/32K
148000 - 14FFFF
SA49
64K/32K
150000 - 157FFF
SA50
64K/32K
158000 - 15FFFF
SA51
64K/32K
160000 - 167FFF
SA52
64K/32K
168000 - 16FFFF
SA53
64K/32K
170000 - 177FFF
SA54
64K/32K
178000 - 17FFFF
SA55
64K/32K
180000 - 187FFF
SA56
64K/32K
188000 - 18FFFF
SA57
64K/32K
190000 - 197FFF
SA58
64K/32K
198000 - 19FFFF
SA59
64K/32K
1A0000 - 1A7FFF
SA60
64K/32K
1A8000 - 1AFFFF
SA61
64K/32K
1B0000 - 1B7FFF
SA62
64K/32K
1B8000 - 1BFFFF
SA63
64K/32K
1C0000 - 1C7FFF
SA64
64K/32K
1C8000 - 1CFFFF
SA65
64K/32K
1D0000 - 1D7FFF
SA66
64K/32K
1D8000 - 1DFFFF
SA67
64K/32K
1E0000 - 1E7FFF
SA68
64K/32K
1E8000 - 1EFFFF
SA69
64K/32K
1F0000 -1F7FFF
SA70
64K/32K
1F8000 - 1FFFF
18
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
AT49BV320CT – Sector Address Table
Sector
Size (Bytes/Words)
Address Range (A20 - A0)
SA0
64K/32K
00000 - 07FFF
SA1
64K/32K
08000 - 0FFFF
SA2
64K/32K
10000 - 17FFF
SA3
64K/32K
18000 - 1FFFF
SA4
64K/32K
20000 - 27FFF
SA5
64K/32K
28000 - 2FFFF
SA6
64K/32K
30000 - 37FFF
SA7
64K/32K
38000 - 3FFFF
SA8
64K/32K
40000 - 47FFF
SA9
64K/32K
48000 - 4FFFF
SA10
64K/32K
50000 - 57FFF
SA11
64K/32K
58000 - 5FFFF
SA12
64K/32K
60000 - 67FFF
SA13
64K/32K
68000 - 6FFFF
SA14
64K/32K
70000 - 77FFF
SA15
64K/32K
78000 - 7FFFF
SA16
64K/32K
80000 - 87FFF
SA17
64K/32K
88000 - 8FFFF
SA18
64K/32K
90000 - 97FFF
SA19
64K/32K
98000 - 9FFFF
SA20
64K/32K
A0000 - A7FFF
SA21
64K/32K
A8000 - AFFFF
SA22
64K/32K
B0000 - B7FFF
SA23
64K/32K
B8000 - BFFFF
SA24
64K/32K
C0000 - C7FFF
SA25
64K/32K
C8000 - CFFFF
SA26
64K/32K
D0000 - D7FFF
SA27
64K/32K
D8000 - DFFFF
SA28
64K/32K
E0000 - E7FFF
SA29
64K/32K
E8000 - EFFFF
SA30
64K/32K
F0000 - F7FFF
SA31
64K/32K
F8000 - FFFFF
SA32
64K/32K
100000 - 107FFF
SA33
64K/32K
108000 - 10FFFF
SA34
64K/32K
110000 - 117FFF
SA35
64K/32K
118000 - 11FFFF
SA36
64K/32K
120000 - 127FFF
SA37
64K/32K
128000 - 12FFFF
19
3372D–FLASH–5/04
AT49BV320CT – Sector Address Table (Continued)
Sector
Size (Bytes/Words)
Address Range (A20 - A0)
SA38
64K/32K
130000 - 137FFF
SA39
64K/32K
138000 - 13FFFF
SA40
64K/32K
140000 - 147FFF
SA41
64K/32K
148000 - 14FFFF
SA42
64K/32K
150000 - 157FFF
SA43
64K/32K
158000 - 15FFFF
SA44
64K/32K
160000 - 167FFF
SA45
64K/32K
168000 - 16FFFF
SA46
64K/32K
170000 - 177FFF
SA47
64K/32K
178000 - 17FFFF
SA48
64K/32K
180000 - 187FFF
SA49
64K/32K
188000 - 18FFFF
SA50
64K/32K
190000 - 197FFF
SA51
64K/32K
198000 - 19FFFF
SA52
64K/32K
1A0000 - 1A7FFF
SA53
64K/32K
1A8000 - 1AFFFF
SA54
64K/32K
1B0000 - 1B7FFF
SA55
64K/32K
1B8000 - 1BFFFF
SA56
64K/32K
1C0000 - 1C7FFF
SA57
64K/32K
1C8000 - 1CFFFF
SA58
64K/32K
1D0000 - 1D7FFF
SA59
64K/32K
1D8000 - 1DFFFF
SA60
64K/32K
1E0000 - 1E7FFF
SA61
64K/32K
1E8000 - 1EFFFF
SA62
64K/32K
1F0000 - 1F7FFF
SA63
8K/4K
1F8000 - 1F8FFF
SA64
8K/4K
1F9000 - 1F9FFF
SA65
8K/4K
1FA000 - 1FAFFF
SA66
8K/4K
1FB000 - 1FBFFF
SA67
8K/4K
1FC000 - 1FCFFF
SA68
8K/4K
1FD000 - 1FDFFF
SA69
8K/4K
1FE000 - 1FEFFF
SA70
8K/4K
1FF000 - 1FFFFF
20
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
DC and AC Operating Range
AT49BV320C(T)-70
Operating
Temperature (Case)
Ind.
-40°C - 85°C
VCC Power Supply
2.65V to 3.6V
Operating Modes
Mode
Read
Program/Erase
(2)
Standby/Program Inhibit
CE
OE
WE
RESET
VPP
Ai
I/O
VIL
VIL
VIH
VIH
X
Ai
DOUT
VIL
VIH
VIHPP(5)
Ai
DIN
X
VIH
X
X
High-Z
VIL
VIH
(1)
VIH
X
X
X
VIH
VIH
X
X
VIL
X
VIH
X
X
X
X
VIH
VILPP(6)
Output Disable
X
VIH
X
VIH
X
Reset
X
X
X
VIL
X
Program Inhibit
Product Identification Software
Notes:
1.
2.
3.
4.
5.
6.
VIH
High-Z
X
High-Z
A0 = VIL, A1 - A20 = VIL
Manufacturer Code(4)
A0 = VIH, A1 - A20 = VIL
Device Code(4)
X can be VIL or VIH.
Refer to AC programming waveforms on page 26.
VH = 12.0V ± 0.5V.
Manufacturer Code: 001FH, Device Code: 88C5H – AT49BV320C; 88C4H – AT49BV320CT
VIHPP (min) = 0.9V; VIHPP (max) = 1.95V.
VILPP (max) = 0.4V.
21
3372D–FLASH–5/04
DC Characteristics
Symbol
Parameter
Condition
ILI
Input Load Current
ILO
ISB
ICC
(1)
Min
Typ
Max
Units
VIN = 0V to VCC
10
µA
Output Leakage Current
VI/O = 0V to VCC
10
µA
VCC Standby Current CMOS
CE = VCC - 0.3V to VCC
13
25
µA
VCC Active Read Current
f = 5 MHz; IOUT = 0 mA
12
25
mA
ICC1
VCC Programming Current
45
mA
IPP1
VPP Input Load Current
10
µA
VIL
Input Low Voltage
0.4
V
VIH
Input High Voltage
VOL
Output Low Voltage
IOL = 100 µA
VOH
Output High Voltage
IOH = -100 µA
Note:
22
VCCQ - 0.2
V
0.10
VCCQ - 0.1
V
V
1. In the erase mode, ICC is 65 mA.
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
AC Read Characteristics
AT49BV320C(T)-70
Symbol
Parameter
tRC
Read Cycle Time
tACC
Address to Output Delay
70
ns
tCE(1)
CE to Output Delay
70
ns
(2)
OE to Output Delay
0
20
ns
(3)(4)
CE or OE to Output Float
0
25
ns
tOH
Output Hold from OE, CE or Address,
whichever occurred first
0
tRO
RESET to Output Delay
tOE
tDF
Min
Max
70
Units
ns
ns
100
ns
AC Read Waveforms(1)(2)(3)(4)
tRC
ADDRESS
ADDRESS VALID
CE
tCE
tOE
OE
tDF
tOH
tACC
tRO
RESET
OUTPUT
Notes:
HIGH Z
OUTPUT
VALID
1. CE may be delayed up to tACC - tCE after the address transition without impact on tACC.
2. OE may be delayed up to tCE - tOE after the falling edge of CE without impact on tCE or by tACC - tOE after an address change
without impact on tACC.
3. tDF is specified from OE or CE, whichever occurs first (CL = 5 pF).
4. This parameter is characterized and is not 100% tested.
23
3372D–FLASH–5/04
Input Test Waveforms and Measurement Level
VCC
VCC/2
0V
tR, tF < 5 ns
Output Test Load
VCCQ
15
15
Pin Capacitance
f = 1 MHz, T = 25°C(1)
Symbol
CIN
COUT
Note:
24
Typ
Max
Units
Conditions
4
6
pF
VIN = 0V
8
12
pF
VOUT = 0V
This parameter is characterized and is not 100% tested.
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
AC Word Load Characteristics
Symbol
Parameter
Min
Max
Units
tAS, tOES
Address, OE Setup Time
45
ns
tAH
Address Hold Time
0
ns
tCS
Chip Select Setup Time
0
ns
tCH
Chip Select Hold Time
0
ns
tWP
Write Pulse Width (WE or CE)
40
ns
tDS
Data Setup Time
45
ns
tDH, tOEH
Data, OE Hold Time
0
ns
tWPH
Write Pulse Width High
30
ns
AC Word Load Waveforms
WE Controlled
CE Controlled
25
3372D–FLASH–5/04
Program Cycle Characteristics
Symbol
Parameter
Min
Typ
Max
Units
tBP
Word Programming Time
tAS
Address Setup Time
45
12
120
µs
ns
tAH
Address Hold Time
0
ns
tDS
Data Setup Time
45
ns
tDH
Data Hold Time
0
ns
tWP
Write Pulse Width
40
ns
tWPH
Write Pulse Width High
30
ns
tWC
Write Cycle Time
70
ns
tRP
Reset Pulse Width
500
tSEC1
Sector Erase Cycle Time (4K Word Sectors)
0.3
3.0
seconds
tSEC2
Sector Erase Cycle Time (32K Word Sectors)
0.8
6.0
seconds
tES
Erase Suspend Time
15
µs
tPS
Program Suspend Time
20
µs
ns
Program Cycle Waveforms
PROGRAM CYCLE
OE
CE
tBP
tWP
WE
tWPH
tDH
tAS
A0 - A20
XX
tAH
(1)
ADDRESS
tWC
DATA
tDS
INPUT DATA
Note 3
Sector Erase Cycle Waveforms
OE
(2)
CE
tWP
tWPH
WE
tDH
tAS
A0-A20
tAH
(1)
XX
SA
tWC
DATA
Notes:
26
1.
2.
3.
4.
(4)
tDS
tEC
20
D0
WORD 0
WORD 1
Any address can be used to load the data.
OE must be high only when WE and CE are both low.
The data can be 40H or 10H.
The address depends on what sector is to be erased.
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
Table 4. Common Flash Interface Definition
Address
AT49BV320CT
AT49BV320C
10h
0051h
0051h
“Q”
11h
0052h
0052h
“R”
12h
0059h
0059h
“Y”
13h
0003h
0003h
14h
0000h
0000h
15h
0041h
0041h
16h
0000h
0000h
17h
0000h
0000h
18h
0000h
0000h
19h
0000h
0000h
1Ah
0000h
0000h
1Bh
0027h
0027h
VCC min write/erase
1Ch
0036h
0036h
VCC max write/erase
1Dh
00B5h
00B5h
VPP min voltage
1Eh
00C5h
00C5h
VPP max voltage
1Fh
0004h
0004h
Typ word write – 12 µs
20h
0000h
0000h
21h
000Ah
000Ah
Typ sector erase, 1,000 ms
22h
0000h
0000h
Typ chip erase, not supported
23h
0003h
0003h
Max word write/typ time
24h
0000h
0000h
n/a
25h
0003h
0003h
Max sector erase/typ sector erase
26h
0000h
0000h
Max chip erase/ typ chip erase
27h
0016h
0016h
Device size
28h
0001h
0001h
x16 device
29h
0000h
0000h
x16 device
2Ah
0000h
0000h
Multiple byte write not supported
2Bh
0000h
0000h
Multiple byte write not supported
2Ch
0002h
0002h
2 regions, x = 2
2Dh
003Eh
0007h
64K bytes, Y = 62 (Top); 8K bytes, Y = 7 (Bottom)
2Eh
0000h
0000h
64K bytes, Y = 62 (Top); 8K bytes, Y = 7 (Bottom)
2Fh
0000h
0020h
64K bytes, Z = 256 (Top); 8K bytes, Z = 32 (Bottom)
30h
0001h
0000h
64K bytes, Z = 256 (Top); 8K bytes, Z = 32 (Bottom)
31h
0007h
003Eh
8K bytes, Y = 7 (Top); 64K bytes, Y = 62 (Bottom)
32h
0000h
0000h
8K bytes, Y = 7 (Top); 64K bytes, Y = 62 (Bottom)
33h
0020h
0000h
8K bytes, Z = 32 (Top); 64K bytes, Z = 256 (Bottom)
34h
0000h
0001h
8K bytes, Z = 32 (Top); 64K bytes, Z = 256 (Bottom)
27
3372D–FLASH–5/04
Table 4. Common Flash Interface Definition (Continued)
Address
AT49BV320CT
AT49BV320C
VENDOR SPECIFIC EXTENDED QUERY
28
41h
0050h
0050h
“P”
42h
0052h
0052h
“R”
43h
0049h
0049h
“I”
44h
0031h
0031h
Major version number, ASCII
45h
0030h
0030h
Minor version number, ASCII
46h
0086h
0086h
Bit 0 – chip erase supported, 0 – no, 1 – yes
Bit 1 – erase suspend supported, 0 – no, 1 – yes
Bit 2 – program suspend supported, 0 – no, 1 – yes
Bit 3 – simultaneous operations supported,
0 – no, 1 – yes
Bit 4 – burst mode read supported, 0 – no, 1 – yes
Bit 5 – page mode read supported, 0 – no, 1 – yes
Bit 6 – queued erase supported, 0 – no, 1 – yes
Bit 7 – protection bits supported, 0 – no, 1 – yes
47h
0000h
0001h
Bit 8 – top (“0”) or bottom (“1”) boot sector device undefined bits are “0”
48h
0000h
0000h
Bit 0 – 4 word linear burst with wrap around,
0 – no, 1 – yes
Bit 1 – 8 word linear burst with wrap around,
0 – no, 1 – yes
Bit 2 – continuos burst, 0 - no, 1 - yes
Undefined bits are “0”
49h
0000h
0000h
Bit 0 – 4 word page, 0 – no, 1 – yes
Bit 1 – 8 word page, 0 – no, 1 – yes
Undefined bits are “0”
4Ah
0080h
0080h
Location of protection register lock byte, the
section’s first byte
4Bh
0003h
0003h
# of bytes in the factory prog section of prot
register – 2*n
4Ch
0003h
0003h
# of bytes in the user prog section of prot
register – 2*n
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
AT49BV320C(T) Ordering Information
ICC (mA)
tACC
(ns)
Active
Standby
Ordering Code
Package
Operation Range
70
25
0.025
AT49BV320C-70CI
AT49BV320C-70TI
47C1
48T
Industrial
(-40° to 85° C)
70
25
0.025
AT49BV320CT-70CI
AT49BV320CT-70TI
47C1
48T
Industrial
(-40° to 85° C)
Package Type
47C1
47-ball, Plastic Chip-Size Ball Grid Array Package (CBGA)
48T
48-lead, Plastic Thin Small Outline Package (TSOP)
29
3372D–FLASH–5/04
Packaging Information
47C1 – CBGA
E
A1 BALL ID
D
TOP VIEW
A1
A
E1
0.875 REF
SIDE VIEW
e
A1 BALL CORNER
3.125 REF
COMMON DIMENSIONS
(Unit of Measure = mm)
SYMBOL
MIN
NOM
MAX
A
E
6.90
7.00
7.10
B
E1
C
D
D1
D
5.25 TYP
9.90
D1
10.00
10.10
3.75 TYP
E
A
–
–
1.00
F
A1
0.22
–
–
8
7
6
5
4
3
2
NOTE
e
0.75 BSC
b
0.35 TYP
1
b
BOTTOM VIEW
7/2/03
R
30
2325 Orchard Parkway
San Jose, CA 95131
TITLE
47C1, 47-ball (8 x 6 Array), 0.75 mm Pitch,
7.0 x 10.0 x 1.0 mm Chip-scale Ball Grid Array Package (CBGA)
DRAWING NO.
47C1
REV.
A
AT49BV320C(T)
3372D–FLASH–5/04
AT49BV320C(T)
48T – TSOP
PIN 1
0º ~ 8º
c
Pin 1 Identifier
D1 D
L
b
e
L1
A2
E
A
GAGE PLANE
SEATING PLANE
COMMON DIMENSIONS
(Unit of Measure = mm)
A1
MIN
NOM
MAX
A
–
–
1.20
A1
0.05
–
0.15
A2
0.95
1.00
1.05
D
19.80
20.00
20.20
D1
18.30
18.40
18.50
Note 2
E
11.90
12.00
12.10
Note 2
L
0.50
0.60
0.70
SYMBOL
Notes:
1. This package conforms to JEDEC reference MO-142, Variation DD.
2. Dimensions D1 and E do not include mold protrusion. Allowable
protrusion on E is 0.15 mm per side and on D1 is 0.25 mm per side.
3. Lead coplanarity is 0.10 mm maximum.
L1
0.25 BASIC
b
0.17
0.22
0.27
c
0.10
–
0.21
e
NOTE
0.50 BASIC
10/18/01
R
2325 Orchard Parkway
San Jose, CA 95131
TITLE
48T, 48-lead (12 x 20 mm Package) Plastic Thin Small Outline
Package, Type I (TSOP)
DRAWING NO.
REV.
48T
B
31
3372D–FLASH–5/04
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Regional Headquarters
Europe
Atmel Sarl
Route des Arsenaux 41
Case Postale 80
CH-1705 Fribourg
Switzerland
Tel: (41) 26-426-5555
Fax: (41) 26-426-5500
Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Atmel Operations
Memory
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
RF/Automotive
Theresienstrasse 2
Postfach 3535
74025 Heilbronn, Germany
Tel: (49) 71-31-67-0
Fax: (49) 71-31-67-2340
Microcontrollers
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
La Chantrerie
BP 70602
44306 Nantes Cedex 3, France
Tel: (33) 2-40-18-18-18
Fax: (33) 2-40-18-19-60
ASIC/ASSP/Smart Cards
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Biometrics/Imaging/Hi-Rel MPU/
High Speed Converters/RF Datacom
Avenue de Rochepleine
BP 123
38521 Saint-Egreve Cedex, France
Tel: (33) 4-76-58-30-00
Fax: (33) 4-76-58-34-80
Zone Industrielle
13106 Rousset Cedex, France
Tel: (33) 4-42-53-60-00
Fax: (33) 4-42-53-60-01
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Scottish Enterprise Technology Park
Maxwell Building
East Kilbride G75 0QR, Scotland
Tel: (44) 1355-803-000
Fax: (44) 1355-242-743
Literature Requests
www.atmel.com/literature
Disclaimer: Atmel Corporation makes no warranty for the use of its products, other than those expressly contained in the Company’s standard
warranty which is detailed in Atmel’s Terms and Conditions located on the Company’s web site. The Company assumes no responsibility for any
errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and
does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Atmel are
granted by the Company in connection with the sale of Atmel products, expressly or by implication. Atmel’s products are not authorized for use
as critical components in life support devices or systems.
© Atmel Corporation 2004. All rights reserved. Atmel ® and combinations thereof, are the registered
trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be the trademarks of
others.
Printed on recycled paper.
3372D–FLASH–5/04
/xM