ATMEL AT49F002AN-55JI

Features
• Single-voltage Operation
•
•
•
•
•
•
•
•
•
•
– 5V Read
– 5V Reprogramming
Fast Read Access Time – 55 ns
Internal Program Control and Timer
Sector Architecture
– One 16K Bytes Boot Block with Programming Lockout
– Two 8K Bytes Parameter Blocks
– Four Main Memory Blocks (One 32K Bytes, Three 64K Bytes)
Fast Erase Cycle Time – 4 Seconds
Byte-by-Byte Programming – 20 µs/Byte Typical
Hardware Data Protection
DATA Polling for End of Program Detection
Low Power Dissipation
– 25 mA Active Current
– 100 µA CMOS Standby Current
Typical 10,000 Write Cycles
Green (Pb/Halide-free) Packaging Option
1. Description
The AT49F002A(N)(T) is a 5-volt only in-system reprogrammable Flash memory. Its
2 megabits of memory is organized as 262,144 words by 8 bits. Manufactured with
Atmel’s advanced nonvolatile CMOS technology, the device offers access times to
55 ns with power dissipation of just 137 mW over the industrial temperature range.
2-megabit
(256K x 8)
5-volt Only
Flash Memory
AT49F002A
AT49F002AN
AT49F002AT
AT49F002ANT
When the device is deselected, the CMOS standby current is less than 100 µA. For
the AT49F002AN(T) pin 1 for the PLCC package and pin 9 for the TSOP package are
no connect pins.
To allow for simple in-system reprogrammability, the AT49F002A(N)(T) does not
require high input voltages for programming. Five-volt-only commands determine the
read and programming operation of the device. Reading data out of the device is similar to reading from an EPROM; it has standard CE, OE, and WE inputs to avoid bus
contention. Reprogramming the AT49F002A(N)(T) is performed by erasing a block of
data and then programming on a byte-by-byte basis. The byte programming time is a
fast 20 µs. The end of a program cycle can be optionally detected by the DATA polling
feature. Once the end of a byte program cycle has been detected, a new access for a
read or program can begin. The typical number of program and erase cycles is in
excess of 10,000 cycles.
The device is erased by executing the erase command sequence; the device internally controls the erase operations. There are two 8K byte parameter block sections,
four main memory blocks, and one boot block.
The device has the capability to protect the data in the boot block; this feature is
enabled by a command sequence. The 16K-byte boot block section includes a reprogramming lock out feature to provide data integrity. The boot sector is designed to
contain user secure code, and when the feature is enabled, the boot sector is protected from being reprogrammed.
3354F–FLASH–2/05
In the AT49F002A(N)(T), once the boot block programming lockout feature is enabled, the contents of the boot block are permanent and cannot be changed. In the AT49F002A(T), once the
boot block programming lockout feature is enabled, the contents of the boot block cannot be
changed with input voltage levels of 5.5 volts or less.
2. Pin Configurations
Function
A0 - A17
Addresses
CE
Chip Enable
OE
Output Enable
WE
Write Enable
RESET
RESET
I/O0 - I/O7
Data Inputs/Outputs
PLCC Top View
29
28
27
26
25
24
23
22
21
14
15
16
17
18
19
20
5
6
7
8
9
10
11
12
13
A14
A13
A8
A9
A11
OE
A10
CE
I/O7
I/O1
I/O2
GND
I/O3
I/O4
I/O5
I/O6
A7
A6
A5
A4
A3
A2
A1
A0
I/O0
4
3
2
1
32
31
30
A12
A15
A16
RESET *
VCC
WE
A17
2.1
Pin Name
2.2
VSOP (8 x 14 mm) or TSOP Type 1 (8 x 20 mm) – Top View
A11
A9
A8
A13
A14
A17
WE
VCC
* RESET
A16
A15
A12
A7
A6
A5
A4
Note:
2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
OE
A10
CE
I/O7
I/O6
I/O5
I/O4
I/O3
GND
I/O2
I/O1
I/O0
A0
A1
A2
A3
*This pin is a NC on the AT49F002AN(T).
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
3. Block Diagram
AT49F002A(N)
DATA INPUTS/OUTPUTS
I/O7 - I/O0
VCC
GND
OE
WE
CE
RESET
ADDRESS
INPUTS
AT49F002A(N)T
DATA INPUTS/OUTPUTS
I/O7 - I/O0
8
CONTROL
LOGIC
8
INPUT/OUTPUT
BUFFERS
INPUT/OUTPUT
BUFFERS
PROGRAM
DATA LATCHES
PROGRAM
DATA LATCHES
Y DECODER
Y-GATING
X DECODER
MAIN MEMORY
BLOCK 4
(64K BYTES)
MAIN MEMORY
BLOCK 3
(64K BYTES)
MAIN MEMORY
BLOCK 2
(64K BYTES)
MAIN MEMORY
BLOCK 1
(32K BYTES)
PARAMETER
BLOCK 2
(8K BYTES)
PARAMETER
BLOCK 1
(8K BYTES)
BOOT BLOCK
(16K BYTES)
Y-GATING
3FFFF
3FFFF
BOOT BLOCK
(16K BYTES)
30000
2FFFF
PARAMETER
BLOCK 1
(8K BYTES)
20000
1FFFF
PARAMETER
BLOCK 2
(8K BYTES)
10000
0FFFF
MAIN MEMORY
BLOCK 1
(32K BYTES)
08000
07FFF
MAIN MEMORY
BLOCK 2
(64K BYTES)
06000
05FFF
04000
03FFF
00000
MAIN MEMORY
BLOCK 3
(64K BYTES)
MAIN MEMORY
BLOCK 4
(64K BYTES)
3C000
3BFFF
3A000
39FFF
38000
37FFF
30000
2FFFF
20000
1FFFF
10000
0FFFF
00000
4. Device Operation
4.1
Read
The AT49F002A(N)(T) is accessed like an EPROM. When CE and OE are low and WE is high,
the data stored at the memory location determined by the address pins is asserted on the outputs. The outputs are put in the high impedance state whenever CE or OE is high. This dual-line
control gives designers flexibility in preventing bus contention.
4.2
Command Sequences
When the device is first powered on, it will be reset to the read or standby mode depending upon
the state of the control line inputs. In order to perform other device functions, a series of command sequences are entered into the device. The command sequences are shown in the
Command Definitions table. The command sequences are written by applying a low pulse on the
WE or CE input with CE or WE low (respectively) and OE high. The address is latched on the
falling edge of CE or WE, whichever occurs last. The data is latched by the first rising edge of
CE or WE. Standard microprocessor write timings are used. The address locations used in the
command sequences are not affected by entering the command sequences.
3
3354F–FLASH–2/05
4.3
Reset
A RESET input pin is provided to ease some system applications. When RESET is at a logic
high level, the device is in its standard operating mode. A low level on the RESET input halts the
present device operation and puts the outputs of the device in a high impedance state. If the
RESET pin makes a high to low transition during a program or erase operation, the operation
may not be successfully completed and the operation will have to be repeated after a high level
is applied to the RESET pin. When a high level is reasserted on the RESET pin, the device
returns to the read or standby mode, depending upon the state of the control inputs. By applying
a 12V ± 0.5V input signal to the RESET pin, the boot block array can be reprogrammed even if
the boot block lockout feature has been enabled (see Boot Block Programming Lockout Override section). The RESET feature is not available for the AT49F002AN(T).
4.4
Erasure
Before a byte can be reprogrammed, the main memory block or parameter block which contains
the byte must be erased. The erased state of the memory bits is a logical “1”. The entire device
can be erased at one time by using a 6-byte software code. The software chip erase code consists of 6-byte load commands to specific address locations with a specific data pattern (please
refer to the Chip Erase Cycle Waveforms).
After the software chip erase has been initiated, the device will internally time the erase operation so that no external clocks are required. The maximum time needed to erase the whole chip
is tEC. If the boot block lockout feature has been enabled, the data in the boot sector will not be
erased.
4.4.1
Chip Erase
If the boot block lockout has been enabled, the Chip Erase function will erase Parameter
Block 1, Parameter Block 2, Main Memory Block 1-4 but not the boot block. If the Boot Block
Lockout has not been enabled, the Chip Erase function will erase the entire chip. After the full
chip erase the device will return back to read mode. Any command during chip erase will be
ignored.
4.4.2
Sector Erase
As an alternative to a full chip erase, the device is organized into sectors that can be individually
erased. There are two 8K-byte parameter block sections and four main memory blocks. The 8Kbyte parameter block sections and the four main memory blocks can be independently erased
and reprogrammed. The Sector Erase command is a six bus cycle operation. The sector
address is latched on the falling WE edge of the sixth cycle while the 30H data input command is
latched at the rising edge of WE. The sector erase starts after the rising edge of WE of the sixth
cycle. The erase operation is internally controlled; it will automatically time to completion.
4
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
4.5
Byte Programming
Once the memory array is erased, the device is programmed (to a logical “0”) on a byte-by-byte
basis. Please note that a data “0” cannot be programmed back to a “1”; only erase operations
can convert “0”s to “1”s. Programming is accomplished via the internal device command register
and is a 4 bus cycle operation (please refer to the Command Definitions table). The device will
automatically generate the required internal program pulses.
The program cycle has addresses latched on the falling edge of WE or CE, whichever occurs
last, and the data latched on the rising edge of WE or CE, whichever occurs first. Programming
is completed after the specified tBP cycle time. The DATA polling feature may also be used to
indicate the end of a program cycle.
4.6
Boot Block Programming Lockout
The device has one designated block that has a programming lockout feature. This feature prevents programming of data in the designated block once the feature has been enabled. The size
of the block is 16K bytes. This block, referred to as the boot block, can contain secure code that
is used to bring up the system. Enabling the lockout feature will allow the boot code to stay in the
device while data in the rest of the device is updated. This feature does not have to be activated;
the boot block’s usage as a write protected region is optional to the user. The address range of
the boot block is 00000 to 03FFF for the AT49F002A(N) while the address range of the boot
block is 3C000 to 3FFFF for the AT49F002A(N)T.
Once the feature is enabled, the data in the boot block can no longer be erased or programmed
with input voltage levels of 5.5V or less. Data in the main memory block can still be changed
through the regular programming method. To activate the lockout feature, a series of six program commands to specific addresses with specific data must be performed. Please refer to the
Command Definitions table.
4.6.1
Boot Block Lockout Detection
A software method is available to determine if programming of the boot block section is locked
out. When the device is in the software product identification mode (see Software Product Identification Entry and Exit sections) a read from address location 00002H will show if programming
the boot block is locked out for the AT49F002A(N), and a read from address location 3C002H
will show if programming the boot block is locked out for AT49F002A(N)T. If the data on I/O0 is
low, the boot block can be programmed; if the data on I/O0 is high, the program lockout feature
has been activated and the block cannot be programmed. The software product identification
exit code should be used to return to standard operation.
4.6.2
Boot Block Programming Lockout Override
The user can override the boot block programming lockout by taking the RESET pin to 12 volts.
By doing this, protected boot block data can be altered through a chip erase, sector erase or
word programming. When the RESET pin is brought back to TTL levels the boot block programming lockout feature is again active. This feature is not available on the AT49F002AN(T).
5
3354F–FLASH–2/05
4.7
Product Identification
The product identification mode identifies the device and manufacturer as Atmel. It may be
accessed by hardware or software operation. The hardware operation mode can be used by an
external programmer to identify the correct programming algorithm for the Atmel product.
For details, see Operating Modes (for hardware operation) or Software Product Identification.
The manufacturer and device code is the same for both modes.
4.8
DATA Polling
The AT49F002A(N)(T) features DATA polling to indicate the end of a program cycle. During a
program cycle an attempted read of the last byte loaded will result in the complement of the
loaded data on I/O7. Once the program cycle has been completed, true data is valid on all outputs and the next cycle may begin. DATA polling may begin at any time during the program
cycle.
4.9
Toggle Bit
In addition to DATA polling the AT49F002A(N)(T) provides another method for determining the
end of a program or erase cycle. During a program or erase operation, successive attempts to
read data from the device will result in I/O6 toggling between one and zero. Once the program
cycle has completed, I/O6 will stop toggling and valid data will be read. Examining the toggle bit
may begin at any time during a program cycle.
4.10
Hardware Data Protection
Hardware features protect against inadvertent programs to the AT49F002A(N)(T) in the
following ways: (a) VCC sense: if VCC is below 3.8V (typical), the program function is inhibited.
(b) Program inhibit: holding any one of OE low, CE high or WE high inhibits program cycles.
(c) Noise filter: pulses of less than 15 ns (typical) on the WE or CE inputs will not initiate a program cycle.
6
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
5. Command Definition Table
Command
Sequence
1st Bus
Cycle
2nd Bus
Cycle
Bus
Cycles
Addr
Data
Read
1
Addr
DOUT
Chip Erase
6
555
AA
Sector Erase
3rd Bus
Cycle
4th Bus
Cycle
5th Bus
Cycle
Addr
Data
Addr
Data
Addr
Data
Addr
Data
Addr
Data
AAA(2)
55
555
80
555
AA
AAA
55
555
10
6
555
AA
AAA
55
555
80
555
AA
4
555
AA
AAA
55
555
A0
Addr
DIN
Boot Block Lockout
6
555
AA
AAA
55
555
80
555
AA
Product ID Entry
3
555
AA
AAA
55
555
90
(4)
3
555
AA
AAA
55
555
F0
(4)
1
XXXX
F0
Byte Program
(3)
Product ID Exit
Product ID Exit
Notes:
6th Bus
Cycle
(5)
AAA
55
SA
30
AAA
55
555
40
1. The DATA FORMAT in each bus cycle is as follows: I/O7 - I/O0 (Hex). The address format in each bus cycle is as follows:
A11 - A0 (Hex); A11 - A17 (don’t care).
2. Since A11 is don’t care, AAA can be replaced with 2AA.
3. The 16K byte boot sector has the address range 00000H to 03FFFH for the AT49F002A(N) and 3C000H to 3FFFFH for the
AT49F002A(N)T
4. Either one of the Product ID Exit commands can be used.
5. SA = sector addresses:
For the AT49F002A(N):
SA = 00000 to 03FFF for BOOT BLOCK
SA = 04000 to 05FFF for PARAMETER BLOCK 1
SA = 06000 to 07FFF for PARAMETER BLOCK 2
SA = 08000 to FFFF for MAIN MEMORY ARRAY BLOCK 1
SA = 10000 to 1FFFF for MAIN MEMORY ARRAY BLOCK 2
SA = 20000 to 2FFFF for MAIN MEMORY ARRAY BLOCK 3
SA = 30000 to 3FFFF for MAIN MEMORY ARRAY BLOCK 4
For the AT49F002A(N)T:
SA = 3C000 to 3FFFF for BOOT BLOCK
SA = 3A000 to 3BFFF for PARAMETER BLOCK 1
SA = 38000 to 39FFF for PARAMETER BLOCK 2
SA = 30000 to 37FFF for MAIN MEMORY ARRAY BLOCK 1
SA = 20000 to 2FFFF for MAIN MEMORY ARRAY BLOCK 2
SA = 10000 to 1FFFF for MAIN MEMORY ARRAY BLOCK 3
SA = 00000 to 0FFFF for MAIN MEMORY ARRAY BLOCK 4
6. Absolute Maximum Ratings*
Temperature Under Bias................................ -55°C to +125°C
Storage Temperature ..................................... -65°C to +150°C
All Input Voltages
(including NC Pins)
with Respect to Ground ...................................-0.6V to +6.25V
All Output Voltages
with Respect to Ground .............................-0.6V to VCC + 0.6V
*NOTICE:
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the
device. This is a stress rating only and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to
absolute maximum rating conditions for extended
periods may affect device reliability.
Voltage on OE
with Respect to Ground ...................................-0.6V to +13.5V
7
3354F–FLASH–2/05
7. DC and AC Operating Range
AT49F002A(N)(T)-55
Operating Temperature (Case)
Ind.
-40°C - 85°C
VCC Power Supply
5V ± 10%
8. Operating Modes
Mode
Read
Program/Erase
(2)
Standby/Write Inhibit
CE
OE
WE
RESET(6)
Ai
I/O
VIL
VIL
VIH
VIH
Ai
DOUT
VIL
VIH
VIL
VIH
Ai
DIN
X
High Z
(1)
VIH
X
X
VIH
X
X
VIH
VIH
X
VIL
X
VIH
Output Disable
X
VIH
X
VIH
Reset
X
X
X
VIL
VIL
VIL
VIH
Program Inhibit
High Z
X
High Z
A1 - A17 = VIL, A9 = VH,(3) A0 = VIL
Manufacturer Code(4)
A1 - A17 = VIL, A9 = VH,(3) A0 = VIH
Device Code(4)
A0 = VIL, A1 - A17=VIL
Manufacturer Code(4)
A0 = VIH, A1 - A17=VIL
Device Code(4)
Product Identification
Hardware
Software(5)
Notes:
1.
2.
3.
4.
5.
6.
X can be VIL or VIH.
Refer to AC Programming Waveforms.
VH = 12.0V ± 0.5V.
Manufacturer Code: 1FH, Device Code: 07H - AT49F002A(N), 08H – AT49F002A(N)T
See details under Software Product Identification Entry/Exit.
This pin is not available on the AT49F002AN(T).
9. DC Characteristics
Symbol
Parameter
Condition
ILI
Input Load Current
ILO
Max
Units
VIN = 0V to VCC
10
µA
Output Leakage Current
VI/O = 0V to VCC
10
µA
ISB1
VCC Standby Current CMOS
CE = VCC - 0.3V to VCC
100
µA
ISB2
VCC Standby Current TTL
CE = 2.0V to VCC
3
mA
ICC(1)
VCC Active Current
f = 5 MHz; IOUT = 0 mA
25
mA
VIL
Input Low Voltage
0.8
V
VIH
Input High Voltage
VOL
Output Low Voltage
IOL = 2.1 mA
VOH1
Output High Voltage
IOH = -400 µA
2.4
V
VOH2
Output High Voltage CMOS
IOH = -100 µA; VCC = 4.5V
4.2
V
Note:
8
Min
2.0
V
0.45
V
1. In the erase mode, ICC is 90 mA.
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
10. AC Read Characteristics
AT49F002A(N)(T)-55
Symbol
Parameter
tACC
Min
Max
Units
Address to Output Delay
55
ns
(1)
CE to Output Delay
55
ns
tOE(2)
OE to Output Delay
0
30
ns
tDF(3)(4)
CE or OE to Output Float
0
25
ns
tOH
Output Hold from OE, CE or Address, whichever
occurred first
0
tCE
ns
11. AC Read Waveforms (1)(2)(3)(4)
ADDRESS
ADDRESS
VALID
CE
OE
tCE
tOE
t DF
tACC
OUTPUT
Notes:
HIGH Z
tOH
OUTPUT
VALID
1. CE may be delayed up to tACC - tCE after the address transition without impact on tACC.
2. OE may be delayed up to tCE - tOE after the falling edge of CE without impact on tCE or by tACC - tOE after an address change
without impact on tACC.
3. tDF is specified from OE or CE whichever occurs first (CL = 5 pF).
4. This parameter is characterized and is not 100% tested.
9
3354F–FLASH–2/05
12. Input Test Waveform and Measurement Level
tR, tF < 5 ns
13. Output Load Test
55 ns
5.0V
1.3K
1.8K
OUTPUT
PIN
30 pF
14. Pin Capacitance
f = 1 MHz, T = 25°C(1)
Symbol
Typ
Max
Units
Conditions
CIN
4
6
pF
VIN = 0V
COUT
8
12
pF
VOUT = 0V
Note:
10
1. This parameter is characterized and is not 100% tested.
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
15. AC Byte Load Characteristics
Symbol
Parameter
Min
Max
Units
tAS, tOES
Address, OE Set-up Time
0
ns
tAH
Address Hold Time
25
ns
tCS
Chip Select Set-up Time
0
ns
tCH
Chip Select Hold Time
0
ns
tWP
Write Pulse Width (WE or CE)
25
ns
tDS
Data Set-up Time
25
ns
tDH, tOEH
Data, OE Hold Time
0
ns
tWPH
Write Pulse Width High
20
ns
16. AC Byte Load Waveforms
16.1
WE Controlled
OE
tOES
tOEH
ADDRESS
CE
WE
tAS
tAH
tCH
tCS
tWPH
tWP
tDH
tDS
DATA IN
16.2
CE Controlled
OE
tOES
tOEH
ADDRESS
tAS
tAH
tCH
WE
tCS
CE
tWPH
tWP
tDS
tDH
DATA IN
11
3354F–FLASH–2/05
17. Program Cycle Characteristics
Symbol
Parameter
Min
Typ
Max
Units
tBP
Byte Programming Time
20
50
µs
tAS
Address Set-up Time
0
ns
tAH
Address Hold Time
25
ns
tDS
Data Set-up Time
25
ns
tDH
Data Hold Time
0
ns
tWP
Write Pulse Width
25
ns
tWPH
Write Pulse Width High
20
ns
tEC
Erase Cycle Time
4
8
seconds
18. Program Cycle Waveforms
19. Sector or Chip Erase Cycle Waveforms
Notes:
12
1. OE must be high only when WE and CE are both low.
2. For chip erase, the address should be 555. For sector erase, the address depends on what sector is to be erased.
(See note 4 under command definitions.)
3. For chip erase, the data should be 10H, and for sector erase, the data should be 30H.
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
20. Data Polling Characteristics(1)
Symbol
Parameter
Min
tDH
Data Hold Time
10
ns
tOEH
OE Hold Time
10
ns
Max
(2)
tOE
OE to Output Delay
tWR
Write Recovery Time
Notes:
Typ
Units
ns
0
ns
1. These parameters are characterized and not 100% tested.
2. See tOE spec in AC Read Characteristics.
21. Data Polling Waveforms
WE
CE
tOEH
OE
tDH
tOE
I/O7
A0-A17
An
tWR
HIGH Z
An
An
An
An
22. Toggle Bit Characteristics(1)
Symbol
Parameter
Min
Typ
tDH
Data Hold Time
10
ns
tOEH
OE Hold Time
10
ns
(2)
Max
Units
tOE
OE to Output Delay
tOEHP
OE High Pulse
50
ns
Write Recovery Time
0
ns
tWR
Notes:
ns
1. These parameters are characterized and not 100% tested.
2. See tOE spec in AC Read Characteristics.
23. Toggle Bit Waveforms(1)(2)(3)
WE
CE
tOEH
tOEHP
OE
tDH
I/O6
Notes:
tOE
HIGH Z
tWR
1. Toggling either OE or CE or both OE and CE will operate toggle bit. The tOEHP specification must be met by the toggling
input(s).
2. Beginning and ending state of I/O6 will vary.
3. Any address location may be used but the address should not vary.
13
3354F–FLASH–2/05
24. Software Product Identification
Entry(1)
26. Boot Block Lockout Feature Enable
Algorithm(1)
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA 55
TO
ADDRESS AAA
LOAD DATA 90
TO
ADDRESS 555
LOAD DATA 80
TO
ADDRESS 555
ENTER PRODUCT
IDENTIFICATION
MODE(2)(3)(5)
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
25. Software Product Identification
Exit(1)
LOAD DATA AA
TO
ADDRESS 555
LOAD DATA 55
TO
ADDRESS AAA
OR
LOAD DATA 40
TO
ADDRESS 555
LOAD DATA F0
TO
ANY ADDRESS
EXIT PRODUCT
IDENTIFICATION
MODE(4)
LOAD DATA F0
TO
ADDRESS 555
PAUSE 1 second(2)
Notes:
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. Boot block lockout feature enabled.
EXIT PRODUCT
IDENTIFICATION
MODE(4)
Notes:
14
1. Data Format: I/O7 - I/O0 (Hex);
Address Format: A14 - A0 (Hex).
2. A1 - A17 = VIL.
Manufacture Code is read for A0 = VIL;
Device Code is read for A0 = VIH.
Additional Device Code is read for address 0003H
3. The device does not remain in identification mode if
powered down.
4. The device returns to standard operation mode.
5. Manufacturer Code: 1FH
Device Code: 07H - AT49F002A(N)
08H - AT49F002A(N)T
Additional Device Code: 0FH - AT49F002A(N)(T)
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
27. Ordering Information
27.1
Standard Package
ICC (mA)
tACC
(ns)
Active
Standby
55
25
Ordering Code
Package
Operation Range
0.1
AT49F002A-55JI
AT49F002A-55TI
AT49F002A-55VI
32J
32T
32V
Industrial
(-40° to 85°C)
32J
32T
32V
Industrial
(-40° to 85°C)
55
25
0.1
AT49F002AN-55JI
AT49F002AN-55TI
AT49F002AN-55VI
55
25
0.1
AT49F002AT-55JI
AT49F002AT-55TI
AT49F002AT-55VI
32J
32T
32V
Industrial
(-40° to 85°C)
55
25
0.1
AT49F002ANT-55JI
AT49F002ANT-55TI
AT49F002ANT-55VI
32J
32T
32V
Industrial
(-40° to 85°C)
27.2
Green Package Option (Pb/Halide-free)
ICC (mA)
tACC
(ns)
Active
Standby
55
25
55
25
Ordering Code
Package
Operation Range
0.1
AT49F002AN-55JU
AT49F002AN-55TU
AT49F002AN-55VU
32J
32T
32V
Industrial
(-40° to 85°C)
0.1
AT49F002ANT-55JU
AT49F002ANT-55TU
AT49F002ANT-55VU
32J
32T
32V
Industrial
(-40° to 85°C)
Package Type
32J
32-lead, Plastic J-leaded Chip Carrier Package (PLCC)
32T
32-lead, Plastic Thin Small Outline Package (TSOP) (8 x 20 mm)
32V
32-lead, Plastic Thin Small Outline Package (VSOP) (8 x 14 mm)
15
3354F–FLASH–2/05
28. Packaging Information
28.1
32J – PLCC
1.14(0.045) X 45˚
PIN NO. 1
IDENTIFIER
1.14(0.045) X 45˚
0.318(0.0125)
0.191(0.0075)
E1
E2
B1
E
B
e
A2
D1
A1
D
A
0.51(0.020)MAX
45˚ MAX (3X)
COMMON DIMENSIONS
(Unit of Measure = mm)
D2
Notes:
1. This package conforms to JEDEC reference MS-016, Variation AE.
2. Dimensions D1 and E1 do not include mold protrusion.
Allowable protrusion is .010"(0.254 mm) per side. Dimension D1
and E1 include mold mismatch and are measured at the extreme
material condition at the upper or lower parting line.
3. Lead coplanarity is 0.004" (0.102 mm) maximum.
SYMBOL
MIN
NOM
MAX
A
3.175
–
3.556
A1
1.524
–
2.413
A2
0.381
–
–
D
12.319
–
12.573
D1
11.354
–
11.506
D2
9.906
–
10.922
E
14.859
–
15.113
E1
13.894
–
14.046
E2
12.471
–
13.487
B
0.660
–
0.813
B1
0.330
–
0.533
e
NOTE
Note 2
Note 2
1.270 TYP
10/04/01
R
16
2325 Orchard Parkway
San Jose, CA 95131
TITLE
32J, 32-lead, Plastic J-leaded Chip Carrier (PLCC)
DRAWING NO.
REV.
32J
B
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
28.2
32T – TSOP
PIN 1
0º ~ 8º
c
Pin 1 Identifier
D1 D
L
b
e
L1
A2
E
A
GAGE PLANE
SEATING PLANE
COMMON DIMENSIONS
(Unit of Measure = mm)
A1
MIN
NOM
MAX
A
–
–
1.20
A1
0.05
–
0.15
A2
0.95
1.00
1.05
D
19.80
20.00
20.20
D1
18.30
18.40
18.50
Note 2
E
7.90
8.00
8.10
Note 2
L
0.50
0.60
0.70
SYMBOL
Notes:
1. This package conforms to JEDEC reference MO-142, Variation BD.
2. Dimensions D1 and E do not include mold protrusion. Allowable
protrusion on E is 0.15 mm per side and on D1 is 0.25 mm per side.
3. Lead coplanarity is 0.10 mm maximum.
L1
0.25 BASIC
b
0.17
0.22
0.27
c
0.10
–
0.21
e
NOTE
0.50 BASIC
10/18/01
R
2325 Orchard Parkway
San Jose, CA 95131
TITLE
32T, 32-lead (8 x 20 mm Package) Plastic Thin Small Outline
Package, Type I (TSOP)
DRAWING NO.
REV.
32T
B
17
3354F–FLASH–2/05
28.3
32V – VSOP
PIN 1
0º ~ 8º
c
Pin 1 Identifier
D1 D
L
b
e
L1
A2
E
A
GAGE PLANE
SEATING PLANE
COMMON DIMENSIONS
(Unit of Measure = mm)
A1
MIN
NOM
MAX
A
–
–
1.20
A1
0.05
–
0.15
A2
0.95
1.00
1.05
D
13.80
14.00
14.20
D1
12.30
12.40
12.50
Note 2
E
7.90
8.00
8.10
Note 2
L
0.50
0.60
0.70
SYMBOL
Notes:
1. This package conforms to JEDEC reference MO-142, Variation BA.
2. Dimensions D1 and E do not include mold protrusion. Allowable
protrusion on E is 0.15 mm per side and on D1 is 0.25 mm per side.
3. Lead coplanarity is 0.10 mm maximum.
L1
0.25 BASIC
b
0.17
0.22
0.27
c
0.10
–
0.21
e
NOTE
0.50 BASIC
10/18/01
R
18
2325 Orchard Parkway
San Jose, CA 95131
TITLE
32V, 32-lead (8 x 14 mm Package) Plastic Thin Small Outline
Package, Type I (VSOP)
DRAWING NO.
REV.
32V
B
AT49F002A(N)(T)
3354F–FLASH–2/05
AT49F002A(N)(T)
19
3354F–FLASH–2/05
Atmel Corporation
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 487-2600
Regional Headquarters
Europe
Atmel Sarl
Route des Arsenaux 41
Case Postale 80
CH-1705 Fribourg
Switzerland
Tel: (41) 26-426-5555
Fax: (41) 26-426-5500
Asia
Room 1219
Chinachem Golden Plaza
77 Mody Road Tsimshatsui
East Kowloon
Hong Kong
Tel: (852) 2721-9778
Fax: (852) 2722-1369
Japan
9F, Tonetsu Shinkawa Bldg.
1-24-8 Shinkawa
Chuo-ku, Tokyo 104-0033
Japan
Tel: (81) 3-3523-3551
Fax: (81) 3-3523-7581
Atmel Operations
Memory
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
RF/Automotive
Theresienstrasse 2
Postfach 3535
74025 Heilbronn, Germany
Tel: (49) 71-31-67-0
Fax: (49) 71-31-67-2340
Microcontrollers
2325 Orchard Parkway
San Jose, CA 95131, USA
Tel: 1(408) 441-0311
Fax: 1(408) 436-4314
La Chantrerie
BP 70602
44306 Nantes Cedex 3, France
Tel: (33) 2-40-18-18-18
Fax: (33) 2-40-18-19-60
ASIC/ASSP/Smart Cards
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Biometrics/Imaging/Hi-Rel MPU/
High Speed Converters/RF Datacom
Avenue de Rochepleine
BP 123
38521 Saint-Egreve Cedex, France
Tel: (33) 4-76-58-30-00
Fax: (33) 4-76-58-34-80
Zone Industrielle
13106 Rousset Cedex, France
Tel: (33) 4-42-53-60-00
Fax: (33) 4-42-53-60-01
1150 East Cheyenne Mtn. Blvd.
Colorado Springs, CO 80906, USA
Tel: 1(719) 576-3300
Fax: 1(719) 540-1759
Scottish Enterprise Technology Park
Maxwell Building
East Kilbride G75 0QR, Scotland
Tel: (44) 1355-803-000
Fax: (44) 1355-242-743
Literature Requests
www.atmel.com/literature
Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any
intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL’S TERMS AND CONDITIONS OF SALE LOCATED ON ATMEL’S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY
WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT
OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no
representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications
and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Atmel’s products are not
intended, authorized, or warranted for use as components in applications intended to support or sustain life.
© Atmel Corporation 2005. All rights reserved. Atmel®, logo and combinations thereof, and others, are registered trademarks, and
Everywhere You AreSM and others are the trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be
trademarks of others.
Printed on recycled paper.
3354F–FLASH–2/05