EMC filters 3-line filters Sine-wave output filters Rated current 6 to 35 A Series/Type: B84143V*R027 Date: January 2006 EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS’ prior express consent is prohibited. 3-line filters B84143V*R027 Sine-wave output filters Sine-wave filters for 3-phase systems Rated voltage 440/250 V AC, 50/60 Hz Rated current 6 to 35 A Construction ■ 3-line filter ■ Metal case Features ■ ■ ■ ■ ■ Easy to install Space-saving design Degree of protection: IP 201) Motor cables of more than 100 m possible Minimized motor noise and eddy current losses in the motor windings Applications ■ Sine-wave output filters for frequency converters in – variable speed drivers – solar systems – UPS Terminals ■ Finger-safe terminal blocks Marking Marking on component: Manufacturer’s logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code, terminal assignment Minimum marking on packaging: Manufacturer’s logo, ordering code Further versions ■ Higher currents for sine-wave output filters on request ■ EMC sine-wave filters on request 1) To IEC 60529 Please read Cautions and warnings and Important notes at the end of this document. 2 01/06 3-line filters B84143V*R027 Sine-wave output filters Typical circuit diagram Converter Load U1 U2 V1 V2 W1 W2 SSB1572-D-E Technical data and measuring conditions Rated voltage VR 440/250 V AC, 50/60 Hz Rated current IR Referred to 40 °C ambient temperature Test voltage Vtest 1770 V DC, 2 s (line/line) 2700 V DC, 2 s (lines/case) Overload capability (thermal) 1.5 · IR for 1 min per hour Converter output frequency fM 0 … 100 Hz Converter pulse frequency fP 6 … 16 kHz Voltage drop (input to output) ∆V At IR and 50 Hz Capacitive reactive current Iq At 400/230 V AC, 50 Hz (typical value) Max. voltage Vpeak (e.g. overshot pulse edge max.) 700 V Max. dv/dt at input 5 kV/µs Climatic category (IEC 60068-1) 25/100/21 (–25 °C/+100 °C/21 days damp heat test) Characteristics and ordering codes VR AC V 440/250 Terminal Iq cross section A mm2 ∆V Rtyp V mΩ 6 4 0.24 10 200 5.2 B84143V0006R027 12 4 0.48 8 66 7.9 B84143V0012R027 16 4 0.81 8 49 8.3 B84143V0016R027 25 6 1.20 7 27 11.1 B84143V0025R027 35 6 1.60 7 15 16.6 B84143V0035R027 IR A Please read Cautions and warnings and Important notes at the end of this document. 3 01/06 Approx. weight kg Ordering code 3-line filters B84143V*R027 Sine-wave output filters Dimensional drawings B84143V0006R027 (6 A) 372 45 27.5 95 80 350 54.5 40 20 380 37.5 PE U2 V2 W2 LOAD Marking Inverter PE U1 V1 W1 70±0.3 Thread M5 Terminal blocks 4 mm 2 Tightening torque 0.6 ... 0.8 Nm 91 6.5 365±0.3 SSB1567-C-E B84143V0012R027, B84143V0016R027 (12 A, 16 A) 372 350 95 115 80 27.5 89.5 40 20 380 37.5 PE U2 V2 W2 LOAD Marking Inverter Terminal blocks 4 mm 2 Tightening torque 0.6 ... 0.8 Nm Please read Cautions and warnings and Important notes at the end of this document. PE U1 V1 W1 91 Thread M5 70±0.3 6.5 365±0.3 SSB1568-K-E 4 01/06 3-line filters B84143V*R027 Sine-wave output filters B84143V0025R027 (25 A) 381 27.5 95 150 350 114 104 40 20 37.5 380 PE U2 V2 W2 LOAD Marking Inverter PE U1 V1 W1 Terminal blocks 6 mm 2 Tightening torque 1.5 ... 1.8 Nm 91 Thread M5 70±0.3 6.5 365±0.3 SSB1570-W-E B84143V0035R027 (35 A) 381 45 20 130 114 150 350 104 40 55 380 365±0.3 LOAD Marking Inverter Terminal blocks 6 mm 2 Tightening torque 1.5 ... 1.8 Nm Please read Cautions and warnings and Important notes at the end of this document. PE U1 V1 W1 126 PE U2 V2 W2 105±0.3 6.5 Thread M5 SSB1571-5-E 5 01/06 EMC filters Cautions and warnings Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into ). The same applies to the warning signs on the filter. Please ensure that the signs operation (see are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings ■ It shall be ensured that only qualified persons (electricity specialists) are engaged on work such ■ ■ ■ ■ as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective. 6 01/06 EMC filters Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as “hazardous”). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the “General Terms of Delivery for Products and Services in the Electrical Industry” published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. 7 01/06