Filled Core Cables Outside Voice & Data Filled Solid CACSP Cable Spec. 2002 RUS (REA) PE-39 CACSP Core Construction: Conductors: • Solid, annealed copper; sizes 19, 22 and 24 AWG Insulation: • Solid, high density polyethylene, color coded in accordance with telephone industry standards Nominal Cable Data CATALOG NUMBER PAIRS AWG O.D. INCHES WEIGHT LBS/MFT STANDARD LENGTH (FT) 7529647 7529654 7529662 7529670 7529688 7529746 7529753 7529761 7529779 7529787 7529795 7529803 7529811 7529829 7529837 7529845 7529852 7529860 7529878 7529886 7529894 7529902 7529910 7529928 7529936 7529944 7529951 7529969 7529977 7529985 7529993 7530009 7530017 7530025 6/19 12/19 18/19 25/19 50/19 6/22 12/22 18/22 25/22 50/22 75/22 100/22 150/22 200/22 300/22 400/22 600/22 900/22 6/24 12/24 18/24 25/24 50/24 75/24 100/24 150/24 200/24 300/24 400/24 600/24 900/24 1200/24 1500/24 1800/24 0.55 0.75 0.87 0.97 1.3 0.45 0.56 0.66 0.71 0.95 1.1 1.2 1.4 1.7 2.0 2.3 2.8 3.4 0.43 0.51 0.57 0.61 0.81 0.92 1.0 1.2 1.3 1.6 1.9 2.2 2.7 3.1 3.4 3.7 185 325 440 555 1000 120 185 255 305 540 750 920 1310 1740 2520 3300 4910 7110 105 150 190 220 385 510 650 900 1120 1680 2150 3120 4550 6020 7370 8630 5000 5000 5000 5000 2500 5000 5000 5000 5000 5000 5000 2500 2500 2500 1250 1250 1250 800 5000 5000 5000 5000 5000 5000 5000 5000 2500 2500 2500 1250 1250 1000 800 700 Data subject to change without notice. Contact your Customer Service Representative for latest information. Twisted Pairs: • Insulated conductors are twisted into pairs with varying lay lengths to minimize crosstalk Core Assembly: • 25 pairs and less: pairs are assembled together in a single group • More than 25 pairs: pairs are arranged in groups, each group having a color coded unit binder Filling Compound: • The entire core assembly is completely filled with ETPR compound, filling the interstices between the pairs and under the core tape Core Wrap: • Non-hygroscopic dielectric tape applied longitudinally with an overlap CACSP Sheath: Aluminum Shield: • Corrugated, copolymer coated, 0.008" aluminum tape applied longitudinally over the core wrap Steel Shield: • Corrugated, copolymer coated, 0.006" steel tape applied longitudinally over the aluminum tape with an overlap • The sheath interfaces are flooded with an adhesive water blocking compound Jacket: • Black, linear low density polyethylene Application(s): • Intended for duct and direct buried installations where protection against water and moisture entry is required • The addition of the steel tape armor provides increased mechanical protection and gopher resistance Compliance: • Rural Utilities Service (RUS) 7 CFR 1755.390 (REA PE-39) Packaging: • Standard lengths are shipped on non-returnable wood reels • Non-standard packaging is available upon request 15