Filled Solid CACSP Cable Spec. 2002

Filled Core Cables
Outside Voice & Data
Filled Solid CACSP Cable
Spec. 2002
RUS (REA) PE-39 CACSP
Core Construction:
Conductors:
• Solid, annealed copper; sizes 19, 22 and
24 AWG
Insulation:
• Solid, high density polyethylene, color
coded in accordance with telephone
industry standards
Nominal Cable Data
CATALOG
NUMBER
PAIRS
AWG
O.D.
INCHES
WEIGHT
LBS/MFT
STANDARD
LENGTH (FT)
7529647
7529654
7529662
7529670
7529688
7529746
7529753
7529761
7529779
7529787
7529795
7529803
7529811
7529829
7529837
7529845
7529852
7529860
7529878
7529886
7529894
7529902
7529910
7529928
7529936
7529944
7529951
7529969
7529977
7529985
7529993
7530009
7530017
7530025
6/19
12/19
18/19
25/19
50/19
6/22
12/22
18/22
25/22
50/22
75/22
100/22
150/22
200/22
300/22
400/22
600/22
900/22
6/24
12/24
18/24
25/24
50/24
75/24
100/24
150/24
200/24
300/24
400/24
600/24
900/24
1200/24
1500/24
1800/24
0.55
0.75
0.87
0.97
1.3
0.45
0.56
0.66
0.71
0.95
1.1
1.2
1.4
1.7
2.0
2.3
2.8
3.4
0.43
0.51
0.57
0.61
0.81
0.92
1.0
1.2
1.3
1.6
1.9
2.2
2.7
3.1
3.4
3.7
185
325
440
555
1000
120
185
255
305
540
750
920
1310
1740
2520
3300
4910
7110
105
150
190
220
385
510
650
900
1120
1680
2150
3120
4550
6020
7370
8630
5000
5000
5000
5000
2500
5000
5000
5000
5000
5000
5000
2500
2500
2500
1250
1250
1250
800
5000
5000
5000
5000
5000
5000
5000
5000
2500
2500
2500
1250
1250
1000
800
700
Data subject to change without notice. Contact your Customer Service Representative for latest information.
Twisted Pairs:
• Insulated conductors are twisted into
pairs with varying lay lengths to minimize
crosstalk
Core Assembly:
• 25 pairs and less: pairs are assembled
together in a single group
• More than 25 pairs: pairs are arranged in
groups, each group having a color coded
unit binder
Filling Compound:
• The entire core assembly is completely
filled with ETPR compound, filling the
interstices between the pairs and under
the core tape
Core Wrap:
• Non-hygroscopic dielectric tape applied
longitudinally with an overlap
CACSP Sheath:
Aluminum Shield:
• Corrugated, copolymer coated, 0.008"
aluminum tape applied longitudinally over
the core wrap
Steel Shield:
• Corrugated, copolymer coated, 0.006"
steel tape applied longitudinally over the
aluminum tape with an overlap
• The sheath interfaces are flooded with an
adhesive water blocking compound
Jacket:
• Black, linear low density polyethylene
Application(s):
• Intended for duct and direct buried
installations where protection against
water and moisture entry is required
• The addition of the steel tape armor
provides increased mechanical protection
and gopher resistance
Compliance:
• Rural Utilities Service (RUS)
7 CFR 1755.390
(REA PE-39)
Packaging:
• Standard lengths are shipped on
non-returnable wood reels
• Non-standard packaging is available upon
request
15