ITT is a diversified leading manufacturer of highly engineered critical
components and customized technology solutions for the energy, transportation and industrial markets. Building on its heritage of innovation,
ITT partners with its customers to deliver enduring solutions to the key
industries that underpin our modern way of life. Founded in 1920, ITT
is headquartered in White Plains, N. Y., with employees in more than 35
countries and sales in a total of approximately 125 countries. The company generated 2012 revenues of $ 2.2 billion. For more information,
visit www.itt.com.
Our connector portfolio remains the most extensive in the industry, offering a reliable and cost effective range of interconnect solutions with the brands of Cannon, VEAM and BIW Connector Systems.
Continuous investment in technology and research & development have enabled ITT to provide new,
innovative products and solutions to markets including:
2
www.ittcannon.com
lndustrial / lnstrumentation
Transportation
Defense Vehicles
Oil & Gas
Automotive
Commercial & Military Aerospace
Our connector portfolio
remains the most extensive
in the industry, offering a reliable and
cost effective range of interconnect
solutions
Computer, Telecom &
Consumer Electronics
www.ittcannon.com
3
Introduction to CGL
Circular connectors featured by metal shells are usually only good for an
operating voltage of 50 Volts. Voltages in access to that are considered to
be potentially hazardous for any human body. ITT Cannon already in 1987
took appropriate measures to develop the essential design features to
respond to this fact.
There was an increasing need for connectors of such nature seen in
industrial applications like motors and drives and numerous other options
wherever goods or things have to be moved. Usually such applications are
featured by the utilization of mains power which often has to be connected.
Features and benefits
••The products in this catalogue are designed to be utilized with mains power which means 250 – 700 VRMS depending on the insulator
style and the contact arrangement.
••All the plugs and receptacles equipped with a first to mate last to break grounding contact are electrically linked to the shell.
••There are various backshell or adapter options available like PG and metric gland adapters. As there are hundreds of PG and
metric gland versions on the market available we would like our valued customers to purchase these parts separately.
••The Universal Endbell is an ITT Cannon development which offers a shielding option and sealing up to IP69k.
••The 700 V products are coined by a UL certification.
Contact us for detail or your request for a customized solution.
Dimensions shown in mm | Specifications and dimensions subject to change
4
www.ittcannon.com
Table of contents
How to use this catalogue..................................... 6
CGL 250 V– 500 V versions
Product overview.................................................. 7
Ordering reference..................................................9
Contact arrangements...........................................10
Box mounting receptacle CGL02............................12
Straight plug CGL06..............................................13
90˚ plug CGL08.....................................................14
Connectors with Universal Endbells.......................15
300 V special versions............................................16
Accessories...........................................................18
Tooling.................................................................20
CGL 700 V special versions
Product overview..................................................21
Contact arrangements...........................................22
Size 28..................................................................23
Size 36..................................................................24
Tooling.................................................................25
Product safety information....................................26
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
5
How to use
This catalog is split in several sections that help you to
•• get a general overview of all product lines (product overview)
•• get all required detail information (dimensions, product details)
•• get all required support products (accessories, tooling)
The fastest way to find your product of choice is to follow these steps
First section: CGL 250 V–500 V (see page 7–20)
1
Select your product using the “ordering reference”
3
Add accessories and tooling as required on the related
pages
2
Use the detail pages to better understand the available
options and choose the best solution for your needs
4
Use the contact information on the back cover to contact
us for further questions or to get advise on where you can
purchase our products
Second section: CGL 700 V special versions (see page 21–25)
1
Select your product using the “contact arrangement” on
page 22
3
Add contacts from the contact tables and tooling as
required on the related pages
2
Use the detail pages to better understand the available
options and choose the best solution for your needs
4
Use the contact information on the back cover to contact
us for further questions or to get advise on where you can
purchase our products
Dimensions shown in mm | Specifications and dimensions subject to change
6
www.ittcannon.com
CGL 250 V– 500 V VERSIONS
Product overview CGL 250 V–500 V
MECHANICAL FEATURES
ELECTRICAL DATA
Contact rating at 20°C (68°F)
Contact size (AWG/metric)
Ambient temperature
–55/125°C (-67/257°F)
Rated Current (Amax.)
16S /15S
22
16 /15
22
Safety provisions
12
41
Bayonet coupling: IP 68 acc. to ISO 20653 (1 bar pressure within 16 hours)
8/60/100
74
Threaded coupling: IP65 acc. to ISO 20653
4 /160
135
For air and creepage paths, test and operating voltage see page 10 -11
Vibration test
200 m /s² at 10 – 2000 Hz
Mating cycles
Current rating
min. 500
Separating force per contact
The separating force has to be measured acc. to VG 95319 part 2, test no 5.7. using
the required test gage.
Contact size
Separating force
metric
AWG
N min
Gage
15S /15
16S /16
1,0
G 1,56
25
12
1,5
G 2,36
60/100
8
3,0
G 3,58
160
4
4,0
G 5,69
Gage see also VG95234 Part 1
Gage
Contacts resistance
The contact resistance has to be tested acc. to VG95319 part 2, Test no 5.10.1
d DIA
l
+0,01
–1
G 1,56
1,56
9
G 2,36
2,36
12
G 3,58
3,58
13
G 5,69
5,69
13
Contact retention
The contact retention has to be tested acc. to VG95319 part 2, Test no 5.4. Apply
test force in mating direction
Contact size
Contact size
Contact resistance
metric
AWG
mΩ max..
15S /15
16S /16
6,0
25
12
3,0
60 /100
8
1,0
160
4
0,3
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
7
Test force
metric
AWG
N
15S /15
16S /16
35
25
12
55
60/100
8
80
160
4
90
CGL 250 V– 500 V VERSIONS
Product overview CGL 250 V–500 V
MECHANICAL FEATURES (continued)
MECHANICAL FEATURES (continued)
Separating and mating force
Mounting dimension
A
B
Mounting holes for box
mounting connectors,
Style CGL02/CGL02-B
CGL 02A-B
CGL 02A
CGL 06PG-B / CGL 06ME-B
CGL 06PG / CGL 06ME
Shell size
A
B
min.
max
10SL
80
7,2
18
90
20
100
Shell size
CGL02
CGL02-B
CGL02/CGL02-B
ØD H12
ØD H13
ØD H12
ØD H13
10SL
16,0
3,1
18,5
3,2
E±0,1
7,2
18
28,7
3,1
31,1
3,2
27,0
7,2
20
31,8
3,1
34,5
3,2
29,4
18,2
22
100
8,0
22
35,0
3,1
37,8
3,2
31,8
24
110
9,5
24
38,2
3,7
41,3
3,7
34,9
28
110
9,5
28
44,5
3,7
47,1
3,7
39,7
Coupling torques
The allowable coupling torques have to be tested under full bundle conditions of
the connectors acc. to VG95319 part 2, Test no. 5.8.2.
Shell size
Allowable coupling torque Nm
Closing and opening
Opening
CGL-B max.
CGL/CGL-B min.
10SL
1,7
0,23
18
8,0
0,58
20
9,0
0,70
22
11,0
0,80
24
14,0
0,80
28
17,0
0,92
Dimensions shown in mm | Specifications and dimensions subject to change
8
www.ittcannon.com
CGL 250 V– 500 V VERSIONS
Ordering reference
Part number explanation
CGL 08 IN 28 A16 PD1L– B– F80 D14 ***
Series
Shell type
02 – box mounting receptacle with square flange
see page 12
06 – straight plug
see page 13
08 – plug with 90° adapter
see page 14
Class
IN – Universal Endbell (nickel plated)
PG – with PG adapter (nickel plated)
ME – with metric adapter (nickel plated)
A – without endbell (style 02 only)
Shell size
10SL, 18, 20, 22, 24, 28
Contact arrangement
see page 10–11
Contact type
P – pin
S – socket
Performance class
D1 – Grounding contact
Insulator type
L – long insulator = 250 V / 500 V
Bayonet coupling (for threaded version: omit indication)
Contacts*
F80 – crimp contacts
Outer cable diameter (Universal Endbell only)
Modification
F0 – without contacts
F42 – without endbell
*Crimp contacts are solderable
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
9
CGL 250 V– 500 V VERSIONS
CONTACT ARRANGEMENTS
Shell size
Figure
Contact arrangement
Contact number
Contact size
Grounding contact
in cavity
Admissible operating
voltage (VAC)
Examples of
available connectors
CGL02A10SL-3P-C1L***
10SL
C
A
10SL-3
B
 3
16S
C
250
CGL06PG10SL-3S-C1L-***
CGL02A18-10P-D1L-***
18
CGL02A18-10S-D1L-***
18-10
 4
12
D
500
CGL06PG18-10P-D1L-***
CGL06PG18-10S-D1L-***
CGL08PG18-10S-D1L-***
CGL06IN18-10S-D1L-***
CGL02A18-11P-C1L-***
18-11
 5
12
C
500
CGL06PG18-11S-C1L-***
CGL08PG18-11S-C1L-***
CGL02A20G10P-A1L-***
20
20G10
10
10x16
A
400
CGL02A20G10S-A1L-***
CGL06PG20G10P-A1L-***
CGL06PG20G10S-A1L-***
CGL02A22-22P-D1L-***
22
D
A
C
B
22-22
CGL02A22-22S-D1L-***
4
8
D
500
CGL06PG22-22P-D1L-***
CGL06PG22-22S-D1L-***
CGL08PG22-22S-D1L-***
CGL02A22-23P-D1L-***
22-23
CGL02A22-23S-D1L-***
 8
12
D
400
CGL06PG22-23P-D1L-***
CGL06PG22-23S-D1L-***
CGL08PG22-23S-D1L-***
24
G
B
H
F
C
A
B
D
24G8*
 8
12
A
400
D
E
28
CGL02AH24G8P-A1L-***
A
CGL06PGH24G28P-A1L-***
CGL06PGH24G28S-A1L-***
C
E
F
H
G
CGL02AH24G8S-A1L-***
28A16
J
28G24*
CGL02A28A16P-D1L-***
 9
4x4
5x36
D
400
CGL02A28A16S-D1L-***
CGL06PG28A16P-D1L-***
CGL06PG28A16S-D1L-***
CGL02AH28G24P-A1L-***
24
4x12
20x16
A
500
CGL02AH28G24S-A1L-***
CGL06PGH28G24P-A1L-***
CGL06PGH28G24S-A1L-***
* The insulator material is FKM.
***Modification codes please see ordering reference, page 9
Dimensions shown in mm | Specifications and dimensions subject to change
10
www.ittcannon.com
CGL 250 V– 500 V VERSIONS
CONTACT ARRANGEMENTS
LAYOUT SPECIFIC DATA
Min. air distance (mm) / mating face
Contact arrangement
Power-Contact Power-Grounding Signal-Contact
10SL-3
3,3
3,3
Rated Voltage
Signal-Grounding
Class
–
250 V
–
18-10
5,0
5,0
–
–
500 V
18-11
5,0
5,0
–
–
500 V
20G10
4,3
4,0
–
–
400 V
22-22
6,1
5,4
–
–
500 V
22-23
4,3
4,0
–
–
400 V
24G8
5,9
4,0
–
–
400 V
28A16
8,0
4,6
6,1
5,0
400 V
28G24
7,5
5,6
3,4
2,7
500 V
Min. creepage distance (mm) / mating face
Contact arrangement
Power-Contact Power-Grounding Signal-Contact
10SL-3
3,3
3,3
–
Rated Voltage
Signal-Grounding
Class
–
250 V
18-10
5,0
5,0
–
–
500 V
18-11
5,0
5,0
–
–
500 V
20G10
4,3
4,3
–
–
400 V
22-22
6,1
6,1
–
–
500 V
22-23
4,3
4,3
–
–
400 V
24G8
5,9
4,0
–
–
400 V
28A16
8,0
4,6
6,1
5,0
400 V
28G24
7,5
5,6
3,4
2,7
500 V
Admissible operating voltage
The admissible operating voltages indicated in this catalogue are mainly based on customer information for certain projects. The
tables above indicate the actual value for the air and creepage distances and can be used as a calculation basis in connection with
DIN EN 61984. All the plugs and receptacles equipped with a first to mate last to break grounding contact are electrically linked
to the shell.
Basis and assumptions
The pollution degree for industrial plants is normally "3". However, the calculation of the admissible operating voltage is based on the
pollutiondegree "2", as the connectors are completely sealed and the contact parts are not subject to direct contamination or humidity.
Caculation basis for rated connector impulse voltage
Overvoltage category 250/500 V III
Material class 250/500 V III
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
11
CGL 250 V– 500 V VERSIONS
BOX MOUNTING RECEPTACLE CLASS E CGL02
CGL02A-B with bayonet coupling
CGL02-B is a box mounting receptacle for front panel mounting. It mates with plugs CGL06-B and CGL08-B
Part No. (pin insert)
ØA
max.
E
± 0,1
L
max.
M
+0,4
N
± 0,3
ØP
max.
S
± 0,3
ØT
+0,2/– 0,1
CGL02A10SL-3P-C1L-B-F80
18,2
18,2
33,6
14,2
2,8
16,2
25,4
3,2
CGL02A18-10P-D1L-B-F80
30,8
27,0
46,0
19,0
4,0
25,6
35,0
3,2
CGL02A18-11P-C1L-B-F80
30,8
27,0
33,8
19,0
4,0
25,6
35,0
3,2
CGL02A20G10P-A1L-B-F80
34,2
29,4
33,8
19,0
4,0
29,0
38,0
3,2
CGL02A22-22P-D1L-B-F80
37,4
31,8
46,0
19,0
4,0
32,2
41,0
3,2
CGL02A22-23P-D1L-B-F80
37,4
31,8
46,0
19,0
4,0
32,2
41,0
3,2
CGL02AH24G8P-A1L-B-F80
40,9
34,9
46,0
20,6
4,0
35,3
44,5
3,7
CGL02A28A16P-D1L-B-F80
CGL02AH28G24P-A1L-B-F80
46,7
46,7
39,7
39,7
46,0
46,0
20,6
20,6
4,0
4,0
41,4
41,4
50,8
50,8
3,7
3,7
N
±0,3
ØP
max.
S
±0,3
ØT
+0,2/– 0,1
For socket inserts substitute P with S
CGL02A with threaded coupling
CGL02A is a box mounting receptacle for front panel mounting. It mates with plugs CGL06 and CGL08
Part No. (pin insert)
A
Thread
E
±0,1
L
max.
M
+0,4
CGL02A10SL-3P-C1L-F80
5/8-24UNEF-2A
18,2
33,6
14,2
2,8
15,9
25,4
3,1
CGL02A18-10P-D1L-F80
1-1/8-18UNEF-2A
27,0
46,0
19,0
4,0
25,4
35,0
3,1
CGL02A18-11P-C1L-F80
1-1/8-18UNEF-2A
27,0
46,0
19,0
4,0
25,4
35,0
3,1
CGL02A20G10P-A1L-F80
1-1/4-18UNEF-2A
29,4
47,0
19,0
4,0
29,0
38,0
3,1
CGL02A22-22P-D1L-F80
1-3/8-18UNEF-2A
31,8
46,0
19,0
4,0
32,2
41,0
3,1
CGL02A22-23P-D1L-F80
1-3/8-18UNEF-2A
31,8
46,0
19,0
4,0
32,2
41,0
3,1
CGL02AH24G8P-A1L-F80
1-1/2-18UNEF-2A
34,9
46,0
20,6
4,0
35,3
44,5
3,7
CGL02A28A16P-D1L-F80
1-3/4-18UNS-2A
39,7
46,0
20,6
4,0
41,2
50,8
3,7
CGL02AH28G24P-A1L-F80
1-3/4-18UNS-2A
39,7
46,0
20,6
4,0
41,2
50,8
3,7
For socket inserts substitute P with S
Dimensions shown in mm | Specifications and dimensions subject to change
12
www.ittcannon.com
CGL 250 V– 500 V VERSIONS
STRAIGHT PLUG CLASS PG CGL06
CGL06PG/ME-B with bayonet coupling
CGL06PG/ME-B designates a straight plug for the use of heat shrink boots or PG terminations (optional a metric adapter is available). It mates with receptacle CGL02A-B
Part No. (socket insert)
ØA
max.
ØE
max.
L
max.
PG Thread
W
ME Thread
CGL06PG10SL-3S-C1L-B-F80
22,8
21,0
58,0
PG9
M 16 x 1,5
CGL06PG18-10S-D1L-B-F80
36,5
32,0
70,0
PG21
M 25 x 1,5
CGL06PG18-11S-C1L-B-F80
36,5
32,0
70,0
PG21
M 25 x 1,5
CGL06PG20G10S-A1L-B-F80
39,9
32,0
77,0
PG21
M 25 x 1,5
CGL06PG22-22S-D1L-B-F80
43,1
32,0
82,0
PG21
M 32 x 1,5
CGL06PG22-23S-D1L-B-F80
43,1
32,0
82,0
PG21
M 32 x 1,5
CGL06PGH24G8S-A1L-B-F80
46,6
40,0
82,0
PG28
M 32 x 1,5
CGL06PG28A16S-D1L-B-F80
CGL06PGH28G24S-A1L-B-F80
53,4
53,4
50,0
50,0
87,0
87,0
PG36
PG36
M 32 x 1,5
M 32 x 1,5
For pin inserts substitute S with P
For ME-adapter substitute PG with ME
CGL06PG/ME with threaded coupling
CGL06PG/ME designates a straight plug for the use of heat shrink boots or PG terminations (optional a metric adapter is available). It mates with receptacle CGL02A.
Part No. (socket insert)
ØA
max.
C
Thread
ØE
max.
L
max.
PG Thread
W
ME Thread
CGL06PG10SL-3S-C1L-F80
24,1
5/8-24UNEF-2B
21,0
60,0
PG9
M 16 x 1,5
CGL06PG18-10S-D1L-F80
36,5
1-1/8-18UNEF-2B
32,0
70,0
PG21
M 25 x 1,5
CGL06PG18-11S-C1L-F80
36,5
1-1/8-18UNEF-2B
32,0
70,0
PG21
M 25 x 1,5
CGL06PG20G10S-A1L-F80
37,3
1-1/4-18UNEF-2B
32,0
77,0
PG21
M 25 x 1,5
CGL06PG22-22S-D1L-F80
43,1
1-3/8-18UNEF-2B
32,0
82,0
PG21
M 32 x 1,5
CGL06PG22-23S-D1L-F80
40,5
1-3/8-18UNEF-2B
32,0
82,0
PG21
M 32 x 1,5
CGL06PGH24G8S-A1L-F80
43,7
1-1/2-18UNEF-2B
40,0
82,0
PG29
M 32 x 1,5
CGL06PG28A16S-D1L-F80
50,0
1-3/4-18UNS-2B
50,0
87,0
PG36
M 32 x 1,5
CGL06PGH28G24S-A1L-F80
50,0
1-3/4-18UNS-2B
50,0
87,0
PG36
For pin inserts substitute S with P
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
M 32 x 1,5
For ME-adapter substitute PG with ME
13
CGL 250 V– 500 V VERSIONS
90° PLUG CLASS PG CGL08
CGL08PG-B with bayonet coupling
CGL08PG-B designates a 90° plug for the use of heat shrink boots or PG terminations. It mates with receptacle CGL02A-B (metric thread option not available)
Part No. (pin Insert)
ØA
max.
L
max.
W
PG Thread
CGL08PG10SL-3P-C1L-B-F80
22,8
57,0
PG9
CGL08PG18-10P-D1L-B-F80
36,5
77,0
PG16
CGL08PG18-11P-C1L-B-F80
36,5
77,0
PG16
CGL08PG20G10P-D1L-B-F80
39,9
82,0
PG21
CGL08PG22-22P-D1L-B-F80
43,1
82,0
PG21
CGL08PG22-23P-F1L-B-F80
43,1
82,0
PG21
For socket inserts substitute P with S
CGL08PG with threaded coupling
CGL08PG designates a 90° plug for the use of heat shrink boots or PG terminations. It mates with receptacle CGL02A (metric thread option not available)
Part No. (pin Insert)
ØA
max.
C
Thread
L
max.
W
PG Thread
CGL08PG10SL-3P-C1L-F80
24,1
5/8-24UNEF-2B
57,0
PG9
CGL08PG18-10P-D1L-F80
34,1
1-1/8-18UNEF-2B
77,0
PG16
CGL08PG18-11P-C1L-F80
34,1
1-1/8-18UNEF-2B
77,0
PG16
CGL08PG20G10P-D1L-F80
37,4
1-1/4-18UNEF-2B
82,0
PG21
CGL08PG22-22P-D1L-F80
40,5
1-3/8-18UNEF-2B
82,0
PG21
CGL08PG22-23P-F1L-F80
40,5
1-3/8-18UNEF-2B
82,0
PG21
For socket inserts substitute P with S
Dimensions shown in mm | Specifications and dimensions subject to change
14
www.ittcannon.com
CGL 250 V– 500 V VERSIONS
CONNECTORS WITH UNIVERSAL ENDBELL, STRAIGHT PLUG
CGL06IN-B with bayonet coupling
Part No. (pin Insert)
ØA
max.
ØE
±0,2
L
max.
Cable entry diameter D
Cable sealing area
CGL06IN10SL-3P-C1L-B-F80
22,8
17,9
82
D07 = 4,5 mm – 7,2 mm
D07
CGL06IN18-10P-D1L-B-F80
36,5
30,0
88
D11 = 8,0 mm – 10,3 mm
D11, D13, D14
CGL06IN18-11P-C1L-B-F80
36,5
30,0
88
D13 = 9,0 mm – 12,5 mm
D11, D13, D14
CGL06IN20G10P-A1L-B-F80
39,9
33,6
92
D14 =11,5 mm – 14,2 mm
D13, D14, D17
CGL06IN22-22P-D1L-B-F80
43,1
33,6
98
D17 =14,5 mm – 16,6 mm
D14, D17, D19
CGL06IN22-23P-D1L-B-F80
43,1
33,6
98
D19 =16,1 mm – 18,4 mm
D14, D17, D19
CGL06IN28-A16P-D1L-B-F80
53,4
33,6
105
D20 =17,8 mm – 20,0 mm
D14, D17, D19, D20
CGL06INH28G24P-A1L-B-F80
53,4
33,6
105
D14, D17, D19, D20
For socket inserts substitute P with S
CGL06IN with threaded coupling
Part No. (pin Insert)
ØA
max.
ØE
±0,2
L
max.
C
Thread
Cable entry diameter D
Cable sealing area
CGL06IN10SL-3P-C1L-F80
22,8
17,9
82,0
5/8-24UNEF-2B
CGL06IN18-10P-D1L-F80
36,5
30,0
88,0
1-1/8-18UNEF-2B
D07 = 4,5 mm – 7,2 mm
D07
D11 = 8,0 mm – 10,3 mm
CGL06IN18-11P-C1L-F80
36,5
30,0
88,0
D11, D13, D14
1-1/8-18UNEF-2B
D13 = 9,0 mm – 12,5 mm
CGL06IN20G10P-A1L-F80
39,9
33,6
D11, D13, D14
92,0
1-1/4-18UNEF-2B
D14 =11,5 mm – 14,2 mm
CGL06IN22-22P-D1L-F80
43,1
D13, D14, D17
33,6
98,0
1-3/8-18UNEF-2B
D17 =14,5 mm – 16,6 mm
CGL06IN22-23P-D1L-F80
D14, D17, D19
40,5
33,6
98,0
1-3/8-18UNEF-2B
D19 =16,1 mm – 18,4 mm
D14, D17, D19
CGL06IN28-A16P-D1L-F80
53,4
33,6
105,0
1-3/4-18UNS-2B
D20 =17,8 mm – 20,0 mm
D14, D17, D19, D20
CGL06INH28G24P-A1L-F80
53,4
33,6
105,0
1-3/4-18UNS-2B
For socket inserts substitute P with S
CONNECTORS WITH UNIVERSAL ENDBELL, 90°-VERSION
CGL08IN-B with bayonet coupling
CGL08IN with threaded coupling
For more information
please contact your local
ITT customer service.
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
15
D14, D17, D19, D20
CA (CGL) 300V #22, SPECIAL VERSION
STRAIGHT PLUG WITH SHORT PG GLAND ADAPTER PIN AND SOCKET CONTACTS*
Pin contacts*
Socket contacts*
Part number description
CA06COM-E22-23P-F0-SPL
Ordering designation
CA120001-47
Part number description
CA06COM-E22-23S-F0-SPL
Ordering designation
CA120001-48
WALL MOUNTING RECEPTACLE PIN AND SOCKET CONTACTS*
Pin contacts*
Part number description
CA02COM-E22-23P-F0-SPL
Ordering designation
CA120001-49
Socket contacts*
Part number description
CA02COM-E22-23S-F0-SPL
Ordering designation
CA120001-50
CABLE CONNECTING PLUG WITH SHORT PG GLAND ADAPTER PIN CONTACTS*
Pin contacts*
Part number description
CA01COM-E22-23P-F0-SPL
Ordering designation
CA120001-51
*Ordering table for contacts (Contacts to be ordered separately)
Number of contacts permitted
Contact size
Terminal size
Socket contact crimp
Pin contact crimp
7
7
7
12
12
12
0,5²
1,5²
2,5²
031-8557-040
031-8557-020
031-8557-000
330-8515-104
330-8515-102
330-8515-101
Grounding screw
–
–
–
7
12
4,0²
031-8557-010
330-8515-103
–
7
12
6,0²
031-8557-030
330-8515-105
1
12 Ground
0,5²
031-8665-020
330-8723-022
250-8501-023
1
12 Ground
1,5²
031-8665-021
330-8723-023
250-8501-023
1
12 Ground
2,5²
031-8665-010
330-8723-010
250-8501-023
1
12 Ground
4,0²
031-8665-002
330-8723-003
250-8501-023
1
12 Ground
6,0²
031-8665-024
330-8723-026
250-8501-023
–
Dimensions shown in mm | Specifications and dimensions subject to change
16
www.ittcannon.com
CA (CGL) 300V #28, SPECIAL VERSION
STRAIGHT PLUG WITH SHORT PG ADAPTER PIN AND SOCKET CONTACTS*
Pin contacts*
Socket contacts*
Part number description
CA06COM-E28-2009-16P-F0-SPL
Ordering designation
CA120001-52
Part number description
CA06COM-E28-2009-16S-F0-SPL
Ordering designation
CA120001-53
WALL MOUNTING RECEPTACLE, PIN AND SOCKET CONTACTS*
Pin contacts*
Part number description
CA02CO M-E28-16P-2009-F0-SPL
Socket contacts*
Part number description
CA02COM-E28-16S-2009-F0-SPL
Ordering designation
CA120001-54
Ordering designation
CA120001-55
CABLE CONNECTING PLUG WITH SHORT PG GLAND ADAPTER PIN CONTACTS*
Pin contacts*
Part number description
CA00COM-E28-2009-16P-F0-SPL
Ordering designation
CA120001-56
*Ordering table for contacts (Contacts to be ordered separately)
Number of contacts permitted
5
5
3
Contact size
16
16
 4
Terminal size
0,5²
1,5²
10,0²
Socket contact crimp
031-8639-120
031-8556-110
031-8560-020
Pin contact crimp
330-8659-000
030-8587-000
030-8658-010
3
 4
16,0²
031-8560-000
030-8658-020
1
4 Ground
10,0²
031-8502-003
030-8593-002
250-8501-023
1
4 Ground
16,0²
031-8502-002
030-8593-003
250-8501-023
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
17
Grounding screw
–
–
–
–
CGL 250 V– 500 V VERSIONS
ACCESSORIES
PROTECTIVE CAPS for receptacles with bayonet coupling
Part No.
Shell size
B
max.
ØD
max.
L
±10
ØT
+0,5
CA121003-701
10SL
19,5
23,4
100
4,3
CA121003-706
18
24,5
36,7
113
4,3
CA121003-707
20
24,5
40,1
127
4,3
CA121003-708
22
24,5
43,3
127
4,3
CA121003-709
CA121003-710
24
28
24,5
24,5
46,8
52,6
127
169
4,3
5,5
PROTECTIVE CAPS for receptacles with threaded coupling
Part No.
Shell size
A
B
L
ØT
ØD
Thread
max.
max.
+0,4
max.
CA121003-601
10SL
5/8-24UNEF-2B
11,7
107
3,4
20,2
CA121003-606
18
1-1/8-20UNEF-2B
11,7
120
3,4
32,9
CA121003-607
20
1-1/4-18UNEF-2B
11,7
134
3,4
36,1
CA121003-608
22
1-3/8-18UNEF-2B
11,7
134
3,4
39,4
CA121003-609
24
1-1/2-18UNEF-2B
11,7
147
4,2
42,6
CA121003-610
28
1-3/4-18UNS-2B
13,3
200
4,2
48,9
Dimensions shown in mm | Specifications and dimensions subject to change
18
www.ittcannon.com
CGL 250 V– 500 V VERSIONS
ACCESSORIES
PROTECTIVE CAPS for plugs with bayonet coupling
Part No.
Shell size
B
max.
ØD
max.
L
±10
ØT
+0,5
CA121004-701
10SL
29,0
20,7
100
4,3
CA121004-706
18
37,0
33,3
127
4,3
CA121004-707
20
37,0
36,7
140
4,7
CA121004-708
22
37,0
39,9
140
4,7
CA121004-709
CA121004-710
24
28
37,0
37,0
43,4
49,2
140
197
4,7
4,7
PROTECTIVE CAPS for plugs with threated coupling
Part No.
Shell size
A
B
L
ØT
ØD
Thread
max
max
+0,4
max.
4
CA121004-601
10SL
5/8-24UNEF-2A
20,5
16,7
107
CA121004-606
18
1-1/8-18UNEF-2A
25,0
29,4
120
4
CA121004-607
20
1-1/4-18UNEF-2A
25,0
32,5
134
4,8
CA121004-608
22
1-3/8-18UNEF-2A
25,0
35,7
134
4,8
CA121004-609
24
1-1/2-18UNEF-2A
25,0
38,9
147
4,8
CA121004-610
28
1-3/4-18UNS-2A
25,0
45,2
207
4,8
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
19
CGL 250 V– 500 V VERSIONS
TOOLING
HYDRAULIC HAND CRIMPING TOOL HPW400U-ITT
for crimping contacts of size 60/100/8, 160/4 and 500/0.
Order No. 121586-5257
CRIMP DIE
Contact size
Crimp dies for hydraulic tool
Wrench Size
60/100/8
CT 121586-5231
5,20
160/4
CT 121586-5230
7,25
Locator
CT 121586-5232
HAND CRIMPING TOOL M22520-1/01 for contacts 0,75 – 6,0 mm²
Order No. 121586-5257
CRIMP LOCATOR TH452*
Order No. 995-0002-052
HAND CRIMPING TOOL CCT-CGF-E for ground contacts 0,75 – 6,0 mm²
Order No. 121586-0087
*modified locators are availabe for connectors shown on page 16 –17. Please contact factory!
INSERTION TOOLS
Description
Name
Order No. ref.
Insertion tool for contact size #16
16CIT-1612
121086-3008
Insertion pliers for contact size #16
CIT-F80-16
121086-0097
Insertion tool for contact size #12
CIT-12
121086-3007
Insertion pliers for contact size #12
CIT-F80-12
121086-0096
Insertion tool for contact size #8
CIT-8
121086-0095
Insertion tool for contact size #4
CIT-4
121086-0094
Guide pin #12
27977-12T8
Guide pin #16
27977-16T50
Extraction tool for #16
CET-F80-16
121086-0081
Extraction tool #12
CET-F80-12
121086-0080
Extraction tool #8
CET-8
121086-0079
Extraction tool #4
CET-4
121086-0078
Dimensions shown in mm | Specifications and dimensions subject to change
20
www.ittcannon.com
CGL 700 V SPECIAL VERSIONS
Product overview CGL 700 V
700 V POWER INPUT CONNECTOR
Specification
CGL #II (28-11)
CGL #III (36-11)
Operating voltage
700 V (DC)
700 V (DC)
Insulation category (DIN/VDE 0110)
II
II
Degree of pollution (DIN/VDE 0110)
3
3
Rated insulation voltage (DIN/VDE 0110)
7,2 KV
7,2 KV
Insulation resistance
20 – 80 TΩ (Tera=10¹²)
20 – 80 TΩ (Tera=10¹²)
Temperature range
– 50 / 140°C
– 50/140°C
Power contacts
41 A
100 A
Signal contacts
22 A
22 A
Mating cycles
500 min.
500 min.
IP67 (mated condition)
IP67 (mated condition)
Number of contacts
3 Power, 1 Ground, 7 Signal
3 Power, 1 Ground, 7 Signal
Contact plating
Silver
Silver
Wire size
Crimp 2,5 / 4 / 6 mm²
Crimp 6 / 10 / 16 / 25 mm²
Grounding (pin first to mate last to break)
Crimp 2,5 / 4 / 6 mm²
Crimp 6 / 10 / 16 /25 mm²
Signal contacts
Crimp 1,5 mm²
Crimp 1,5 mm²
Coupling system
Bayonet
Bayonet
Plating
Nickel
Nickel
Polarization
5 key way
5 key way
Material
Aluminium alloy
Aluminium alloy
Available types
see pages 23
see pages 24
Material
Plastic (UL94-V0)
Plastic (UL94-V0)
Design
Fully insulated pin contact for increased creepage distance Fully insulated pin contact for increased creepage distance
Contact insertion extraction principle
Rear release
Rear release
Fluor elastomere
Fluor elastomere
Electrical conditions
Current rating
Degree of protection by enclosures
ISO 20653
Contact arrangement / Plating / Termination
Receptacle housing and straight plug
Insulator
Sealing gaskets
Material
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
21
CGL 700 V SPECIAL VERSIONS
CONTACT ARRANGEMENTS
Shell size
Figure
Contact arrangement
Contact number
Contact size
Grounding contact
in cavity
Admissible operating
voltage (VAC)
Available connectors
CGL66PG28-11P-E1D-B-F0-SPL
28
28-11
CGL66PG28-11S-E1D-B-F0-SPL
11
4x12
7x16
D
700
CGL61PG28-11P-E1D-B-F0-SPL
CGL62A28-11P-E1D-B-F0-SPL
CGL62A28-11S-E1D-B-F0-SPL
CGL66PG36-11S-E1D-B-F0-SPL
36
36-11
CGL61PG36-11P-E1D-B-F0-SPL
11
4x4
7x16
D
700
CGL62A36-11P-E1D-B-F0-SPL
CGL66PG36-11P-E1D-B-F0-SPL
CGL62A36-11S-E1D-B-F0-SPL
LAYOUT SPECIFIC DATA
Contact arrangement
Min. air distance (mm) /mating face Min. creepage distance (mm) /mating face Rated Voltage
Power-Contact Power-Grounding
Power-Power
Power-Grounding
Class
28-11
19,7
12,5
19,7
12,5
700 V
36-11
10,3
10,3
10,3
10,3
700 V
Admissible operating voltage
The admissible operating voltages indicated in this catalogue are mainly based on customer information for certain projects. The
table aboved indicates the actual value for the air and creepage paths and can be used as a calculation basis in connection with
DIN EN 61984. All the plugs and receptacles equipped with a first to mate last to break grounding contact are electrically linked
to the shell.
Basis and assumptions
The pollution degree for industrial plants is normally "3". However, the calculation of the admissible operating voltage is based on the
pollution degree "2", as the connectors are completely sealed and the contact parts are not subject to direct contamination or humidity.
Caculation basis for rated connector impulse voltage
Overvoltage category 700 V III
Material class 700 V II
Dimensions shown in mm | Specifications and dimensions subject to change
22
www.ittcannon.com
CGL 700V #28, SPECIAL VERSION
STRAIGHT PLUG WITH PG GLAND ADAPTER PIN AND SOCKET CONTACTS*
Pin contacts*
Part number description
CGL66PG28-11P-E1D-B-F0-SPL
Socket contacts*
Ordering designation
CGL 120015-9
Part number description
CGL66PG28-11S-E1D-B-F0-SPL
Ordering designation
CGL120015-8
CABLE CONNECTING PLUG WITH PG GLAND ADAPTER PIN CONTACTS*
Pin contacts*
Part number description
CGL61PG28-11P-E1D-B-F0-SPL
Ordering designation
CGL120015-10
WALL MOUNTING RECEPTACLE PIN AND SOCKET CONTACTS*
Pin contacts*
Part number description
CGL62A28-11P-E1D-B-F0-SPL
Socket contacts*
Ordering designation
CGL120015-11
Part number description
CGL62A28-11S-E1D-B-F0-SPL
Ordering designation
CGL120015-12
*Ordering table for contacts (Contacts to be ordered separately)
Number of contacts permitted
Terminal size
Socket contact crimp
Pin contact crimp
Grounding screw
3
3
3
Contact size
12
12
12
2,5²
4,0²
6.0²
031-8716-021
031-8716-022
031-8716-025
030-8719-049
030-8719-070
030-8719-071
–
–
–
1
12 Ground
2,5²
031-8716-031
030-8719-074
250-8501-023
1
12 Ground
4,0²
031-8716-032
030-8719-075
250-8501-023
1
12 Ground
6,0²
031-8716-033
030-8719-076
250-8501-023
7
16
1,5²
031-8716-019
030-8719-045
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
23
–
CGL 700 V #36, SPECIAL VERSIONS
STRAIGHT PLUG WITH PG GLAND ADAPTER PIN AND SOCKET CONTACTS*
Pin contacts*
Socket contacts*
Part number description
CGL66PG36-11P-E1D-B-F0-SPL
Ordering designation
CGL120015-2
Part number description
CGL66PG36-11S-E1D-B-F0-SPL
Ordering designation
CGL120015-1
CABLE CONNECTING PLUG WITH PG GLAND ADAPTER PIN CONTACTS*
Pin contacts*
Part number description
CGL61PG36-11P-E1D-B-F0-SPL
Ordering designation
CGL120015-3
WALL MOUNTING RECEPTACLE PIN AND SOCKET CONTACTS*
Pin contacts*
Socket contacts*
Part number description
CGL62A36-11P-E1D-B-F0-SPL
Ordering designation
CGL120015-4
Part number description
CGL62A36-11S-E1D-B-F0-SPL
Ordering designation
CGL120015-5
*Ordering table for contacts (Contacts to be ordered separately)
Number of contacts permitted
3
3
3
Contact size
4
4
4
Terminal size
6²
10²
16²
Socket contact crimp
031-8716-014
031-8716-015
031-8716-016
Pin contact crimp
030-8719-057
030-8719-058
030-8719-059
Grounding screw
3
4
25²
031-8716-017
030-8719-043
1
4 Ground
6²
031-8716-020
030-8719-060
250-8501-023
1
4 Ground
10²
031-8716-028
030-8719-061
250-8501-023
1
4 Ground
16²
031-8716-029
030-8719-062
250-8501-023
1
4 Ground
25²
031-8716-027
030-8719-044
250-8501-023
7
16
1,5²
031-8716-019
030-8719-045
Dimensions shown in mm | Specifications and dimensions subject to change
24
www.ittcannon.com
CGL 700 V SPECIAL VERSIONS
TOOLING
TOOLS FOR CGL #28
Type
Hand crimp tool (for #12 and #16 contacts as indicated)
EUS101-2
Crimp positioner
CT120090-113
Contact insertion tool, #12 contacts
CIT12
Contact extraction tool, #12 contacts
CT121586-300
Contact insertion tool, #16 contacts
CIT16
Contact extraction tool, #16 contacts
CET-ATR-2160
Contacts
Socket
030-8719-049
031-8716-021
2,5²
030-8719-070
031-8716-022
4,0²
030-8719-071
031-8716-025
6,0²
030-8719-045
031-8716-019
Type
Hand crimp tool for grounding contact,
crimp positioner included in the tool above,
no insertion or extraction tool needed
TOOLS FOR CGL #36
CCT-CGF-E
Contacts
EUS101-2
Crimp positioner
CT120090-113
Contact insertion tool #16 contacts
CIT16
Contact extraction tool #16 contacts
CET-ATR-2160
Pin
Socket
031-8716-031
2,5²
030-8719-075
031-8716-032
4,0²
030-8719-076
031-8716-033
6,0²
Contacts
Socket
030-8719-045
031-8716-019
Contacts
Pin
1,5²
Terminal size
Socket
030-8719-057
031-8716-014
6²
030-8719-058
031-8716-015
10²
Crimp die for hydraulic tool
121586-5230
030-8719-059
031-8716-016
16²
Contact insertion tool
CIT4
030-8719-043
031-8716-017
25²
Contact extraction tool #4 contacts
CT120090-56
Dimensions shown in mm | Specifications and dimensions subject to change
www.ittcannon.com
HPW400U-ITT
121586-5257
Terminal size
Pin
Type
Hydraulic crimp tool for power and
grounding contacts
Terminal size
030-8719-074
Type
Hand crimp tool (for #16 contacts as indicated)
Terminal size
Pin
25
030-8719-060
031-8716-020
6²
030-8719-061
031-8716-028
10²
030-8719-062
031-8716-029
16²
030-8719-044
031-8716-027
25²
PRODUCT SAFETY INFORMATION
1. MATERIAL CONTENT AND PHYSICAL
FORM
Electrical connectors do not usually contain
hazardous materials. They contain
conducting and non-conducting materials
and can be divided into two groups.
a) Printed circuit types and low cost audio
types which employ all plastic insulators and
casings.
b) Rugged, Fire Barrier and High Reliability
types with metal casings and either natural
rubber, synthetic rubber, plastic or glass
insulating materials. Contact materials vary
with type of connector and also application
and are usually manufactured from either:
Copper, copper alloys, nickel, alumel,
chromel or steel. In special applications,
other alloys may be specified.
2. FIRE CHARACTERISTICS AND ELECTRIC
SHOCK HAZARD
There is no fire hazard when the connector
is correctly wired and used within the specified parameters.
Incorrect wiring or assembly of the connector
or careless use of metal tools or conductive
fluids, or transit damage to any of the
component parts may cause electric shock
or burns. Live circuits must not be broken
by separating mated connectors as this may
cause arcing, ionization and burning. Heat
dissipation is greater at maximum resistance
in a circuit. Hot spots may occur when resistance is raised locally by damage, e.g.
cracked or deformed contacts, broken
strands of wire. Local overheating may also
result from the use of the incorrect application tools or from poor quality soldering or
slack screw terminals. Overheating may
occur if the ratings in the product Data
Sheet/Catalog are exceeded and can cause
breakdown of insulation and hence electric
shock. If heating is allowed to continue it
intensifies by further increasing the local
resistance through loss of temper of spring
contacts, formation of oxide film on contacts
and wires and leakage currents through
carbonization of insulation and tracking
paths. Fire can then result in the presence
of combustible materials and this may
release noxious fumes. Overheating may not
be visually apparent. Burns may result from
touching overheated components.
3. HANDLING
Care must be taken to avoid damage to any
component parts of electrical connectors
during installation and use. Although there
are normally no sharp edges, care must be
taken when handling certain components
to avoid injury to fingers.
Electrical connectors may be damaged in
transit to the customers, and damage may
result in creation of hazards. Products
should therefore be examined prior to installation/use and rejected if found to be
damaged.
4. DISPOSAL
Incineration of certain materials may release
noxious or even toxic fumes.
5. APPLICATION
Connectors with exposed contacts should
not be selected for use on the current supply
side of an electrical circuit, because an electric shock could result from touching
exposed contacts on an unmated connector.
Voltages in excess of 30 V ac or 42.5 V DC
are potentially hazardous and care should
be taken to ensure that such voltages cannot
be transmitted in any way to exposed metal
parts of the connector body. The connector
and wiring should be checked, before
making live, to have no damage to metal
parts or insulators, no solder blobs, loose
strands, conducting lubricants, swarf, or any
other undesired conducting particles. Circuit
resistance and continuity check should be
made to make certain that there are no high
resistance joints or spurious conducting
paths. Always use the correct application
tools as specified in the Data Sheet/Catalog.
Do not permit untrained personnel to wire,
assemble or tamper with connectors. For
operation voltage please see appropriate
national regulations.
IMPORTANT GENERAL INFORMATION
(i) Air and creepage paths/Operating
voltage. The admissible operating voltages
depend on the individual applications and
the valid national and other applicable
safety regulations. For this reason the air
and creepage path data are only reference
values. Observe reduction of air and
creepage paths due to PC board and/or
harnessing.
(ii) Temperature
All information given are temperature limits.
The operation temperature depends on the
individual application.
intended to be used in accordance with the
specifications in this publication. Any use or
application that deviates from the stated
operating specifications is not recommended and may be unsafe. No information
and data contained in this publication shall
be construed to create any liability on the
part of Cannon. Any new issue of this publication shall automatically invalidate and
supersede any and all previous issues.
Product Warranty
A limited warranty applies to Cannon products. In general, except for obligations
assumed by Cannon under this warranty,
Cannon shall not be liable for any loss,
damage, cost of repairs, incidental or consequential damages of any kind, whether or
not based on express or implied warranty,
contract, negligence or strict liability arising
in connection with the design, manufacture,
sale, use or repair of the products. Product
availability, prices and delivery dates are
exclusively subject to our respective order
confirmation form; the same applies to
orders based on development samples delivered. Please refer to www.ittcannon.com
(General Terms of Sale) for the complete text
of Cannon’s applicable Terms and Conditions, including Warranty.
This publication is not to be construed as an
offer. It is intended merely as an invitation
to make an offer. By this publication, Cannon
does not assume responsibility or any
liability for any patent infringements or
other rights of third parties which may result
from its use.
Reprinting this publication is generally
permitted, indicating the source. However,
Cannon’s prior consent must be obtained in
all cases. “Engineered for life” is a registered
trademark of ITT Corporation ©2012. All
other trademarks or registered trademarks
are property of their respective owners. All
data subject to change without notice.
This document does not contain technical
data whose export is restricted by the Arms
Export Control Act (Title 22, U.S.C., App
2401 et. Seq.)
(iii) Other important information
Cannon continuously endeavors to improve
their products. Therefore, Cannon products
may deviate from the description, technical
data and shape as shown in this catalog and
data sheets.
ITT's Interconnect Solutions, is a division of
ITT Corporation who manufactures the
highest quality products available in the
marketplace; however these products are
26
www.ittcannon.com
Circular / Filter / Hermetic / Fiber Optic Connectors
As a world leader in circular, filter, and hermetic connectors, ITT can
leverage its design and manufacturing expertise to fit virtually any
application. Our expertise includes fast positive mating for a
wide range of military applications, as well as numerous sizes
and contact configurations for various harsh environments. Our
wide variety of fiber optic products include hybrid contacts,
multi-channel, rack and panel, and hi-rel assemblies, including MIL
and ARINC standard solutions that meet numerous specifications,
including NATO and MIL standards.
D-Subminiature Connectors
Cannon invented D-sub connectors in 1952. Our family of D-Subs
now includes combinations of signal, power and RF, as well as
severe service sealed connectors. Cannon D-Subs are available
with an extensive line of backshells and accessories and are one
of the most economical shielded connector solutions available. ITT
D-Sub connectors are qualified to the MIL-DTL-24308 specification.
Microminiature Connectors
Developed first by Cannon in the 1960’s, ITT's Interconnect Solutions
microminiature connectors offer high performance and reliability
with exceptional versatility. Available in rectangular, circular, and strip
configurations for countless applications, many of our connectors meet
or exceed applicable requirements of the MIL-DTL-83513 specification.
Rack and Panel Connectors
Initially pioneered by Cannon during the 1930s, ITT's Interconnect Solutions
is the world leader in rack and panel connectors, offering unmatched
variety of shell configurations and insert arrangements, materials, plating,
and contact options. Many of our standard and custom designs meet the
stringent requirements of ARINC 600, ARINC 404 (MIL-C-81659), and
MIL-DTL-83733 standards.
Trident
Cannon’s Trident Connector System is a versatile range of electrical
connectors based on a standard contact design. These contacts are fully
interchangeable throughout the Trident Connector System. The connector
options include low cost rectangular, rack and panel, industrial grade
circulars, harsh environment circulars and shielded circulars.
Transportation
The ITT's Interconnect Solutions includes sealed circular and rectangular connectors in
metal or plastic shells. These configurations include board to cable or cable to cable /
bulkhead applications. Both signal and power contacts can be combined in various
layouts. All product lines within the Transportation segment offer very low contact
resistance providing maximum signal integrity.
ITT's Interconnect Solutions is an international manufacturer and supplier of connectors including circular, rectangular, fiber optic, RF, power and
high voltage, audio, PMCIA, Compact Flash Card, enclosures, cable assemblies, and application specific custom solutions. The Interconnect
Solutions portfolio includes the brands Cannon, VEAM, and BIW Connector Systems. As a worldwide leader in connector technology for nearly a
century, ITT offers one of the broadest product offerings, six sigma manufacturing capability, Value Based Product Development with exceptional engineering capability, and an extensive sales, distribution, and customer support network.
www.ittcannon.com
27
ITT Interconnect Solutions
Cannon, VEAM,
BIW Connector Systems
Visit our website at
www.ittcannon.com
Global Design &
Manufacturing
Customer Support
North America
Europe & Middle East
Asia
MEXICO – Cannon, VEAM
Av. Libre Comercio s/nentre Calzada Industrial
Nuevo Nogales y Calzada del Raquet Club,
Parque Industrial Nuevo Nogales
phone:+52.631.3110050
fax:+52.631.3110060
FRANCE – Cannon, VEAM
15, Boulevard Robert Thiboust
Serris, France 77700
phone:+33.1.60.04.93.93
fax:+33.1.60.04.93.90
CHINA – Cannon, VEAM
Tuopandun Industrial Area,
Jinda Cheng, Xiner Village, Shajing Town,
Boan District, Shenzhen City,
Guangdong Province, China 518125
phone: +86.755.2726.7238
fax:
+86.755.2726.7515
USA – Cannon
666 East Dyer Road
Santa Ana, CA 92705
toll free: +1.800.854.3028
phone:+1.714.557.4700
fax:
+1.714.628.2142
USA – BIW Connector Systems
500 Tesconi Circle
Santa Rosa, CA 95401
phone:+1.707.523.2300
fax:+1.707.523.3567
USA - VEAM
100 New Wood Road
Watertown, CT 06795
phone: +1.860.274.9681
fax:
+1.860.274.4963
GERMANY – Cannon, VEAM
Cannonstrasse 1
71384 Weinstadt
phone:+49.7151.699.0
fax:+49.7151.699.217
ITALY – VEAM
Corso Europa 41/43
Lainate (MI), Italy 20020
phone: +39.02938721
fax:
+39.0293872300
LEBANON – BIW Connector
Systems
P.O. Box 199
Jounieh
Lebanon
phone:+961.9.911.560
fax:+961.9.912.126
UK – Cannon, VEAM
Jays Close, Viables Estate
Basingstoke, RG22 4BA
phone: +44.1256.311200
fax: +44.1256.323356
HONG KONG – Cannon, VEAM
Units 2405-6, 24/F, ING Tower
308 Des Voeux Road Central
Hong Kong
phone: +852.2732.2720
fax:
+852.2732.2919
INDIA – Cannon, VEAM
ITT Corporation India Pvt Ltd
Money Chamber, Unit No. 202
#6, KH Road, Bangalore
560027
phone: +91 22 67843000
fax:
+91 22 26783033
JAPAN – Cannon, VEAM
5-11-3, Hibarigaoka,
Zama-shi, Kanagawa, Japan 252-0003
phone: +81.462.57.2010
fax:
+81.462.57.1680
SINGAPORE – Cannon, VEAM
10 Jalan Kilang #06-01
Singapore 159410
phone: +65.62763693 ext 232
fax: +65.62763685
© 2013 ITT Corporation ”Engineered for life” and “Cannon” are registered trademarks of
ITT Corporation. Specification and other data are based on information available at the time
of printing, and are subject to change without notice.