ZL9117M Datasheet

DATASHEET
Digital DC/DC PMBus 17A Module
ZL9117M
Features
The ZL9117M is a 17A, variable output, step-down
PMBus-compliant digital power supply. Included in the module
is a high-performance digital PWM controller, power MOSFETs,
an inductor, and all the passive components required for a
highly integrated DC/DC power solution. This power module
has built-in auto-compensation algorithms, which eliminates
the need for manual compensation design work. The ZL9117M
operates over a wide input voltage range and supports an
output voltage range of 0.6V to 3.6V, which can be set by
external resistors or via PMBus. This high-efficiency power
module is capable of delivering 17A. Only bulk input and
output capacitors are needed to finish the design. The output
voltage can be precisely regulated to as low as 0.6V with ±1%
output voltage regulation over line, load, and temperature
variations.
• Complete digital switch mode power supply
The ZL9117M features auto-compensation, internal soft-start,
auto-recovery overcurrent protection, an enable option, and
prebiased output start-up capabilities.
• Industrial and medical equipment
• Fast transient response
• Auto compensating PID filter
• External synchronization
• Output voltage tracking
• Current sharing
• Programmable soft-start delay and ramp
• Overcurrent/undercurrent protection
• PMBus compliant
Applications
• Server, telecom, and datacom
• General purpose point of load
Related Literature
The ZL9117M is packaged in a thermally enhanced, compact
(15mmx15mm) and low profile (3.5mm) over-molded QFN
package module suitable for automated assembly by standard
surface mount equipment. The ZL9117M is RoHS compliant.
• AN2034, “Configuring Current Sharing on the ZL2004 and
ZL2006”
Figure 1 represents a typical implementation of the ZL9117M.
For PMBus operation, it is recommended to tie the Enable pin
(EN) to SGND.
V DRV
4.7µF
16V
10µF
16V
4.5V TO 6.5V
10µF
16V
4.7µF
16V
V IN
4.5V TO 13.2V
ENABLE
EN
EXT SYNC
DDC BUS
VR
VDD
PG
V25
POWER GOOD OUTPUT
VDRV
CIN
VIN
(EPAD)
VOUT
VOUT
(EPAD)
SYNC
ZL9117M
SW
(EPAD)
DDC
COUT
SCL
RTN
FB-
PGND
(EPAD)
FB+
SGND
SA
VTRK
SDA
VSET
I2C/SMBus
R SA
R SET
FIGURE 1. A COMPLETE DIGITAL SWITCH MODE POWER SUPPLY, ONLY BULK INPUT AND OUTPUT CAPACITORS ARE REQUIRED TO FINISH THE
DESIGN
December 16, 2014
FN7914.4
1
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 1-888-468-3774 | Copyright Intersil Americas LLC 2011-2014. All Rights Reserved
Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries.
All other trademarks mentioned are the property of their respective owners.
ZL9117M
Table of Contents
Related Literature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Pin Configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Pin Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ZL9117M Internal Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Typical Application - Single Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Thermal Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Recommended Operating Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Typical Performance Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Derating Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I2C/SMBus Communications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Voltage Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Soft-start Delay and Ramp Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power-Good . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Switching Frequency and PLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Loop Compensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Adaptive Diode Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input Undervoltage Lockout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Overvoltage Protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Prebias Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Overcurrent Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Overload Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I2C/SMBus Module Address Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital-DC Bus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Spreading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Voltage Tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output Sequencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fault Spreading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Active Current Sharing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Adding/Dropping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Monitoring via I2C/SMBus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Snapshot Parameter Capture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Non-Volatile Memory and Device Security Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
11
11
11
11
12
12
12
12
12
13
13
14
14
14
15
15
15
16
16
16
17
17
17
Layout Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Consideration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PCB Layout Pattern Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Vias. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stencil Pattern Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
18
18
19
19
19
19
PMBus Command Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
PMBus™ Data Formats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Firmware Revision History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Revision History. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
About Intersil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Package Outline Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Submit Document Feedback
2
FN7914.4
December 16, 2014
ZL9117M
Pin Configuration
SGND
VR
DDC
EN
PG
SYNC
SA
SCL
ZL9117M
(21 LD QFN)
TOP VIEW
9
8
7
6
5
4
3
2
1
SDA
PGND
10
21
VSET
V25
11
20
VTRK
VDD
12
19
FB+
VDRV
13
18
FB-
SW
14
VOUT
17
VIN
15
PGND
16
Pin Descriptions
PIN
LABEL
TYPE
1
SDA
I/O
Serial data. A pull-up resistor is required for this application.
2
SCL
I/O
Serial clock. A pull-up resistor is required for this application.
3
SA
I
Serial address select pin. Used to assign unique SMBus address to each module.
4
SYNC
I/O
Clock synchronization. Used for synchronization to external frequency reference.
5
PG
O
Power-good output.
6
EN
I
Enable input (factory setting active high). Pull-up to enable PWM switching and pull-down to disable PWM switching.
7
DDC
I/O
8
VR
PWR
Internal 5V reference used to power internal drivers. Connect 4.7μF bypass capacitor to this pin.
9
SGND
PWR
Signal ground. Connect to low impedance ground plane.
10
PGND
PWR
Power ground. Connect to low impedance ground plane.
11
V25
PWR
Internal 2.5V reference used to power internal circuitry. Connect 4.7μF bypass capacitor to this pin.
12
VDD
PWR
Input supply voltage for controller. Connect 4.7μF bypass capacitor to this pin.
13
VDRV
PWR
Power supply for internal FET drivers. Connect 10μF bypass capacitor to this pin.
14 (epad)
SW
PWR
Drive train switch node.
15 (epad)
VIN
PWR
Power supply input FET voltage.
16 (epad)
PGND
PWR
Power ground. Connect to low impedance ground plane.
17 (epad)
VOUT
PWR
Power supply output voltage. Output voltage from PWM.
18
FB-
I
Output voltage feedback. Connect to load return of ground regulation point.
19
FB+
I
Output voltage feedback. Connect to output regulation point.
20
VTRK
I
Tracking sense input. Used to track an external voltage source.
21
VSET
I
Output voltage selection pin. Used to set VOUT set point and VOUT max.
Submit Document Feedback
DESCRIPTION
Digital-DC bus (open drain). Interoperability between Intersil digital modules. A pull-up resistor is required for this
application.
3
FN7914.4
December 16, 2014
ZL9117M
Ordering Information
PART NUMBER
(Notes 1, 2, 3)
PART
MARKING
FIRMWARE REVISION
(Note 4)
TEMP RANGE
(°C)
PACKAGE
(RoHS Compliant)
PKG.
DWG. #
ZL9117MIRZ
ZL9117M
FC04
-40 to +85
21 Ld 15x15 QFN
L21.15x15
ZL9117MAIRZ
ZL9117M
FC05
-40 to +85
21 Ld 15x15 QFN
L21.15x15
NOTES:
1. Add “-T*” suffix for tape and reel. Please refer to TB347 for details on reel specifications.
2. These Intersil plastic packaged products are RoHS compliant by EU exemption 7C-I and employ special Pb-free material sets, molding compounds/die
attach materials, and 100% matte tin plate plus anneal (e3) termination finish which is compatible with both SnPb and Pb-free soldering operations.
Intersil RoHS compliant products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC
J STD-020.
3. For Moisture Sensitivity Level (MSL), please see product information page for ZL9117M. For more information on MSL please see Tech Brief TB363.
4. See “Firmware Revision History” on page 55; only the latest firmware revision is recommended for new designs.
ZL
xxxxM
DIGITAL MODULE DESIGNATOR
BASE PART NUMBER
FIRMWARE REVISION
BLANK: FC04
A: FC05
OPERATING TEMPERATURE
I: INDUSTRIAL (‐ 40°C TO +85°C)
Submit Document Feedback
4
F
T
R
Z
S
SHIPPING OPTION
BLANK: BULK
T: TAPE AND REEL
RoHS
Z: RoHS COMPLIANT
PACKAGE DESIGNATOR
R: QUAD FLAT NO‐LEAD (QFN)
FN7914.4
December 16, 2014
ZL9117M
MGN
LDO
OV/UV POWER MANAGEMENT
INTERLEAVE
OC/UC
AUTOCOMP
CURRENT SHARE
VDRV
SYNC
OUT
SYNC
VIN
V25
VR
VDD
VSET
LDO
PLL
D-PWM
NVM
GATE DRIVE LOGIC
SS
VTRK
EN
PG
FB
VDRV
ZL9117M Internal Block Diagram
GH
SW
PWMH
0.22µH
BST
PWML
VOUT
SW
GL
NLR
GND
SUPERVISOR
DIGITAL
COMPENSATOR
POWER STAGE
GATE DRIVER
PROTECTION
CSA
22
SCL
SDA
ADC
COMMUNICATION
VDD
DDC
FB+
VSA
VDRV
22
FB-
ADC
SA
TEMP
SENSOR
SGND
DGND
Submit Document Feedback
5
SGND
PGND
DIGITAL CONTROLLER
FN7914.4
December 16, 2014
ZL9117M
Typical Application - Single Module
330µF
BULK
VIN
4.5 to 13.2V
C1
+
2X22µF
CERAMIC
C2
VR
VIN
VDD
V25
C3
10µF
CERAMIC
VDRV
4.5 to 6.5V
VLOGIC 10k 10k 4.75k
3.0 to 6.0V
4.7µF
CERAMIC
C6
4.7µF
CERAMIC
R1
R2
VDRV
4X100µF
CERAMIC
C4
ZL9117M
VOUT
R3
SCL
SCL
SDA
SDA
DDC
DDC
FB-
EN
SYNC
RSA = 51.1k
SMBUS ADD = 0X2A
VOUT
1.2V 17A
R4 = 200
SGND
SYNC
C7
2x330µF
POSCAP
C8 +
FB+
PGND
VTRK
VSET
EN
VTRK
SA
VDD
4.5 to 13.2V
C5
10µF
CERAMIC
RSET = 31.6k
VOUT = 1.2V
NOTES:
5. R1 and R2 are not required if the PMBus host already has I2C pull-up resistors.
6. Only one R3 per DDC bus is required when DDC bus is shared with other modules.
7. The VR, V25, VDRV, and VDD capacitors should be placed no farther than 0.5cm from the pin.
8. R4 is optional but recommended to sink possible ~100µA backflow current from the FB+ pin. Backflow current is present only when the module is
in a disabled state with power still available at the VDD pin.
Submit Document Feedback
6
FN7914.4
December 16, 2014
ZL9117M
Absolute Maximum Ratings
Thermal Information
(Note 9)
Thermal Resistance (Typical)
JA (°C/W) JC (°C/W)
QFN Package (Notes 12, 13) . . . . . . . . . . .
11.5
2.2
Junction Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-55°C to +150°C
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-55°C to +150°C
Pb-Free Reflow Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . see TB493
DC Supply Voltage for VDD Pin . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 15.7V
Input Voltage for VIN Pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 15.7V
MOSFET Drive Reference for VR Pin . . . . . . . . . . . . . . . . . . . . -0.3V to 6.5V
2.5V Logic Reference for V25 Pin. . . . . . . . . . . . . . . . . . . . . . . . . -0.3V to 3V
MOSFET Driver Power for VDRV Pin . . . . . . . . . . . . . . . . . . . . . .-0.3V to 7.5V
Logic I/O Voltage for DDC, EN,
FB+, FB-, PG, SA, SCL, SDA, SYNC, VSET Pins . . . . . . . . . . . . -0.3V to 6V
ESD Rating
Human Body Model (Tested per JESD22-A114F) . . . . . . . . . . . . . . 2000V
Machine Model (Tested per JESD22-A115C) . . . . . . . . . . . . . . . . . . 200V
Charged Device Model (Tested per JESD22-C110D) . . . . . . . . . . . 1000V
Latch Up (Tested per JESD78C; Class 2, Level A) . . . . . . . . . . . . . . . 100mA
Recommended Operating Conditions
Input Supply Voltage Range, VIN . . . . . . . . . . . . . . . . . . . . . . 4.5V to 13.2V
Input Supply For Controller, VDD (Note 10) . . . . . . . . . . . . . . . 4.5V to 13.2V
Driver Supply Voltage, VDRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.5V to 6.5V
Output Voltage Range, VOUT (Note 11) . . . . . . . . . . . . . . . . . . 0.54V to 3.6V
Output Current Range, IOUT(DC) (Note 24). . . . . . . . . . . . . . . . . . . 0A to 17A
Operating Junction Temperature Range, TJ. . . . . . . . . . . .-40°C to +125°C
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
9. Voltage measured with respect to SGND.
10. VIN supplies the power FETs. VDD supplies the controller. VIN can be tied to VDD. For VDD ≤ 5.5V, VDD should be tied to VR.
11. Includes ±10% margin limits.
12. JA is simulated in free air with device mounted on a four-layer FR-4 test board (76.2 x 114.3 x 1.6mm) with 80% coverage, 2oz Cu on top and bottom
layers, plus two, buried, one-ounce Cu layers with coverage across the entire test board area. Multiple vias were used, with via
diameter = 0.3mm on 1.2mm pitch.
13. For JC, the “case” temperature is measured at the center of the package underside.
Electrical Specifications VDD = 12V, TA = -40°C to +85°C unless otherwise noted. Typical values are at TA = +25°C. Boldface limits
apply across the operating temperature range, -40°C to +85°C.
PARAMETER
CONDITIONS
MIN
TYP
MAX
(Note 14) (Note 15) (Note 14)
UNIT
INPUT AND SUPPLY CHARACTERISTICS
Input Bias Supply Current, IDD
VIN = VDD = 13.2V, fSW = 571kHz, No load
–
Input Bias Shutdown Current, IDDS
EN = 0V, No I2C/SMBus activity
20
40
mA
Input Supply Current, IVIN
VIN = 12V, IOUT = 17A, VOUT = 1.0V
–
15.5
20
mA
–
1.78
–
A
Driver Supply Current, IVDRV
VDRV = 6V, VOUT = 1.0V, fSW = 571Hz, IOUT = 17A
–
30
VR Reference Output Voltage (Note 16)
VDD > 6V, IVR < 20mA
4.5
5.2
5.7
mA
V
V25 Reference Output Voltage (Note 16)
VR > 3V, IV25 < 20mA
2.25
2.5
2.75
V
–
OUTPUT CHARACTERISTICS
Output Load Current (Notes 23, 24)
VIN = 12V, VOUT = 1.0V
–
Output Voltage Accuracy (Notes 16, 17)
Include Line, Load, Temp
–1
Peak-to-peak Output Ripple Voltage, ΔVOUT (Note 17) IOUT = 17A, VOUT = 1.0V, COUT = 3000µF
17
A
+1
%
–
6
–
mV
Soft-start Delay Duration Range (Notes 16, 18)
Set using I2C/SMBus
2
–
200
ms
Soft-start Delay Duration Accuracy (Note 16)
Turn-on delay (precise mode) (Notes 18, 19)
–
±0.25
–
ms
Turn-on delay (normal mode) (Note 20)
–
-0.25/+4
–
ms
Turn-off delay (Note 20)
–
-0.25/+4
–
ms
Set using I2C
0
–
200
ms
–
100
–
µs
Soft-start Ramp Duration Range (Note 16)
Soft-start Ramp Duration Accuracy (Note 16)
DYNAMIC CHARACTERISTICS
Voltage Change for Positive Load Step
ΔIOUT = 6A, slew rate = 2.5A/μs, VOUT = 1.0V,
COUT = 3000µF
–
3
–
%
Voltage Change for Negative Load Step
ΔIOUT = 6A, slew rate = 2.5A/μs, VOUT = 1.0V,
COUT = 3000µF
–
3
–
%
Submit Document Feedback
7
FN7914.4
December 16, 2014
ZL9117M
Electrical Specifications VDD = 12V, TA = -40°C to +85°C unless otherwise noted. Typical values are at TA = +25°C. Boldface limits
apply across the operating temperature range, -40°C to +85°C. (Continued)
PARAMETER
CONDITIONS
MIN
TYP
MAX
(Note 14) (Note 15) (Note 14)
UNIT
OSCILLATOR AND SWITCHING CHARACTERISTICS (Note 16)
Switching Frequency Range
400
Maximum PWM Duty Cycle
Factory setting
1000
kHz
95
–
–
%
150
–
–
ns
External clock source
-13
–
13
%
EN, PG, SCL, SDA pins
-10
–
10
µA
–
–
0.8
V
Minimum SYNC Pulse Width
Input Clock Frequency Drift Tolerance
571
LOGIC INPUT/OUTPUT CHARACTERISTICS (Note 16)
Logic Input Bias Current
Logic Input Low, VIL
2.0
–
–
V
Logic Output Low, VOL
IOL ≤ 4mA (Note 22)
–
–
0.4
V
Logic Output High, VOH
IOH ≥ -2mA (Note 22)
2.25
–
–
V
Logic Input High, VIH
FAULT PROTECTION CHARACTERISTICS (Note 16)
Configurable via I2C/SMBus
UVLO Threshold Range
UVLO Set-point Accuracy
UVLO Hysteresis
2.85
–
16
V
-150
–
150
mV
Factory setting
–
3
–
%
Configurable via I2C/SMBus
0
–
100
%
–
–
2.5
µs
–
90
–
% VOUT
UVLO Delay
Power-Good VOUT Threshold
Factory setting
Power-Good VOUT Hysteresis
Factory setting
–
5
–
%
Power-Good Delay (Note 21)
Configurable via I2C/SMBus
0
–
200
ms
VSEN Undervoltage Threshold
Factory setting
–
85
–
% VOUT
Configurable via I2C/SMBus
0
–
110
% VOUT
Factory setting
–
115
–
% VOUT
Configurable via I2C/SMBus
0
–
115
% VOUT
VSEN Overvoltage Threshold
VSEN Undervoltage Hysteresis
–
5
–
% VOUT
VSEN Undervoltage/Overvoltage Fault Response
Time
Factory setting
–
16
–
µs
Configurable via I2C/SMBus
5
–
60
µs
Thermal Protection Threshold
(Controller Junction Temperature)
Factory setting
–
125
–
°C
-40
–
125
°C
–
15
–
°C
Configurable via I2C/SMBus
Thermal Protection Hysteresis
NOTES:
14. Compliance to datasheet limits is assured by one or more methods: production test, characterization and/or design.
15. Parameters with TYP limits are not production tested unless otherwise specified.
16. Parameters are 100% tested for internal controller prior to module assembly.
17. VOUT measured at the termination of the FB+ and FB- sense points.
18. The device requires a delay period following an enable signal and prior to ramping its output. Precise timing mode limits this delay period to
approximately 2ms, where in normal mode it may vary up to 4ms.
19. Precise ramp timing mode is only valid when using the EN pin to enable the device rather than PMBus enable.
20. The devices may require up to a 4ms delay following the assertion of the enable signal (normal mode) or following the de-assertion of the enable
signal.
21. Factory setting for Power-Good delay is set to the same value as the soft-start ramp time.
22. Nominal capacitance of logic pins is 5pF.
23. This condition is tested on the Intersil 3-module evaluation board at +50°C ambient temperature and 400LFM air flow.
24. The load current is related to the thermal derating curves. The maximum allowed current is derated while the output voltage goes higher than 2.5V.
Submit Document Feedback
8
FN7914.4
December 16, 2014
ZL9117M
Typical Performance Curves
Operating condition: TA = +25°C, No air flow, FSW = 571kHz. VDRV = 5V. COUT = 3000µF.
Typical values are used unless otherwise noted.
100
100
VOUT = 3.3V, fSW = 615kHz
VOUT = 2.5V, fSW = 727kHz
90
85
80
VOUT = 1.8V,
fSW = 571kHz
75
VOUT = 1.2V,
fSW = 571kHz
VOUT = 1V,
fSW = 571Hz
2
4
6
8
10
12
14
16
85
80
VOUT = 1.8V,
fSW = 571kHz
75
70
18
0
2
4
14
16
18
FIGURE 3. EFFICIENCY, VIN = 9V, FOR VARIOUS OUTPUT VOLTAGES
FIGURE 2. EFFICIENCY, VIN = 5V, FOR VARIOUS OUTPUT VOLTAGES
100
VOUT = 3.3V, fSW = 800kHz
VOLTAGE DEVIATION (mV)
35
95
EFFICIENCY (%)
VOUT = 1.2V,
fSW = 571kHz
VOUT = 1V,
fSW = 571kH
6
8
10
12
OUTPUT CURRENT (A)
OUTPUT CURRENT (A)
VOUT = 2.5V, fSW = 727kHz
90
85
80
75
70
VOUT = 2.5V, fSW = 727kHz
90
70
0
VOUT = 3.3V, fSW = 800kHz
95
EFFICIENCY (%)
EFFICIENCY (%)
95
0
2
4
VOUT = 1.2V,
fSW = 571kHz
VOUT = 1V,
fSW = 571kH
VOUT = 1.8V,
fSW = 571kHz
6
8
10
12
14
16
VIN = 12V
30 VOUT = 1.2V
I
STEP = 12A TO 6A
25 OUT
SLEW 2.5A/µs
20
15
10
5
0
-5
18
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
TIME (ms)
OUTPUT CURRENT (A)
FIGURE 4. EFFICIENCY, VIN = 12V, FOR VARIOUS OUTPUT
VOLTAGES
FIGURE 5. DYNAMIC RESPONSE, UNLOAD
TIME (ms)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
1.4
0
-5
VOUT (V)
VOLTAGE DEVIATION (mV)
5
0
-10
-15
VIN = 12V
-20 V
OUT = 1.2V
-25 IOUT STEP = 6A TO 12A
VOUT = 1.2V
1.0
tRISE = 5ms
0.8
0.6
0.4
0.2
0
SLEW 2.5A/µs
-0.2
-30
FIGURE 6. DYNAMIC RESPONSE, LOAD
Submit Document Feedback
VIN = 12V
1.2
9
0
1
2
3
4
5
6
TIME (ms)
7
8
9
10
FIGURE 7. SOFT-START RAMP-UP
FN7914.4
December 16, 2014
ZL9117M
Typical Performance Curves
Operating condition: TA = +25°C, No air flow, FSW = 571kHz. VDRV = 5V. COUT = 3000µF.
Typical values are used unless otherwise noted. (Continued)
1.4
VIN = 12V
1.2
VOUT = 1.2V
1.0
tFALL = 5ms
VOUT (V)
0.8
0.6
0.4
0.2
0
-0.2
0
1
2
3
4
5
6
TIME (ms)
7
8
9
10
FIGURE 8. RAMP-DOWN
Derating Curves
Operating conditions: TA = +25°C, FSW = 571kHz. VDRV = 5V. COUT = 3000µF. Typical values are used unless
otherwise noted.
20
20
NO AIR FLOW
MAX. LOAD CURRENT (A)
MAX. LOAD CURRENT (A)
18
16
14
12
10
3.3V
8
1.0V
6
4
16
14
12
10
0
120
130
FIGURE 9. DERATING CURVE, 5VIN, FOR VARIOUS OUTPUT
VOLTAGES LISTED
1.8V
4
0
70
80
90
100
110
AMBIENT TEMPERATURE (°C)
2.5V
6
2
60
3.3V
8
2
50
NO AIR FLOW
18
1.0V
50
60
70
80
90
100
110
AMBIENT TEMPERATURE (°C)
120
130
FIGURE 10. DERATING CURVE, 12VIN, FOR VARIOUS OUTPUT
VOLTAGES LISTED
7
7
1.8V
6
6
5
4
LOSS (W)
LOSS (W)
5
3.3V
3
1.0V
2
3.3V
3
1.2V
1
0
2
4
6
8
10
12
14
16
OUTPUT CURRENT (A)
FIGURE 11. POWER LOSS CURVE, 5VIN, FOR VARIOUS OUTPUT
VOLTAGES LISTED
Submit Document Feedback
10
2.5V
4
2
1.2V
1
0
1.8V
2.5V
18
0
1.0V
0
2
4
6
8
10
12
OUTPUT CURRENT (A)
14
16
18
FIGURE 12. POWER LOSS CURVE, 12VIN, FOR VARIOUS OUTPUT
VOLTAGES LISTED
FN7914.4
December 16, 2014
ZL9117M
Functional Description
TABLE 1. OUTPUT VOLTAGE RESISTOR SETTINGS (Continued)
I2C/SMBus Communications
The ZL9117M provides an I2C/SMBus digital interface that
enables the user to configure all aspects of the module operation
as well as monitor the input and output parameters. The
ZL9117M can be used with any I2C host device. In addition, the
module is compatible with SMBus version 2.0. Pull-up resistors
are required on the I2C/SMBus as specified in the SMBus 2.0
specification. The ZL9117M accepts most standard PMBus
commands. When controlling the device with PMBus commands,
it is recommended that the enable pin is tied to SGND.
The SMBus device address and VOUT_MAX are the only
parameters that must be set by external pins. All other device
parameters can be set via the I2C/SMBus. The device address is
set using the SA pin. VOUT_MAX is determined as 10% greater
than the voltage set by the VSET pin. Standard 1% resistor values
are used between the respective pin and SGND.
Output Voltage Selection
The output voltage may be set to a voltage between 0.6V and
3.6V provided that the input voltage is higher than the desired
output voltage by an amount sufficient to prevent the device
from exceeding its maximum duty cycle specification.
The VSET pin is used to set the output voltage to levels as shown
in Table 1. The RSET resistor is placed between the VSET pin and
SGND.
TABLE 1. OUTPUT VOLTAGE RESISTOR SETTINGS
VOUT
(V)
RSET
(kΩ)
1.80
61.9
1.90
68.1
2.00
75
2.10
82.5
2.20
90.9
2.30
100
2.50
110
2.80
121
3.00
133
3.30
147
The output voltage may also be set to any value between 0.6V
and 3.6V using a PMBus command over the I2C/SMBus
interface.
The RSET resistor program places an upper limit in output
voltage setting through PMBUS programming to 10% above the
value set by the resistor.
Soft-start Delay and Ramp Times
It may be necessary to set a delay from when an enable signal is
received until the output voltage starts to ramp to its target
value. In addition, the designer may wish to precisely set the time
required for VOUT to ramp to its target value after the delay
period has expired. These features may be used as part of an
overall in-rush current management strategy or to precisely
control how fast a load IC is turned on. The ZL9117M gives the
system designer several options for precisely and independently
controlling both the delay and ramp time periods.
VOUT
(V)
RSET
(kΩ)
0.60
10
0.65
11
0.70
12.1
0.75
13.3
0.80
14.7
0.85
16.2
0.90
17.8
0.95
19.6
1.00
21.5
1.05
23.7
1.10
26.1
1.15
28.7
Power-Good
1.20
31.6
1.25
34.8
1.30
38.3
1.40
42.2
1.50
46.4
The ZL9117M provides a Power-Good (PG) signal that indicates
the output voltage is within a specified tolerance of its target
level and no fault condition exists. By default, the PG pin asserts
if the output is within 10% of the target voltage. These limits and
the polarity of the pin may be changed via the I2C/SMBus
interface.
1.60
51.1
1.70
56.2
Submit Document Feedback
11
The soft-start delay period begins when the EN pin is asserted
and ends when the delay time expires.
The soft-start delay and ramp times are set to custom values via
the I2C/SMBus interface. When the delay time is set to 0ms, the
device begins its ramp-up after the internal circuitry has
initialized (approximately 2ms). When the soft-start ramp period
is set to 0ms, the output ramps up as quickly as the output load
capacitance and loop settings allow. It is generally
recommended to set the soft-start ramp to a value greater than
500µs to prevent inadvertent fault conditions due to excessive
in-rush current.
A PG delay period is defined as the time from when all conditions
within the ZL9117M for asserting PG are met to when the PG pin
is actually asserted. This feature is commonly used instead of
FN7914.4
December 16, 2014
ZL9117M
using an external reset controller to control external digital logic.
By default, the ZL9117M PG delay is set equal to the soft-start
ramp time setting. Therefore, if the soft-start ramp time is set to
10ms, the PG delay is set to 10ms. The PG delay may be set
independently of the soft-start ramp using the I2C/SMBus.
Switching Frequency and PLL
The ZL9117M incorporates an internal phase-locked loop (PLL) to
clock the internal circuitry. The PLL can be driven by an external
clock source connected to the SYNC pin. When using the internal
oscillator, the SYNC pin can be configured as a clock source.
If a clock signal is present, the ZL9117M’s oscillator will then
synchronize the rising edge of the external clock. If no incoming
clock signal is present, the ZL9117M will configure the switching
frequency according to the state of the SYNC pin as listed in
Table 2. The internal switching frequency of the ZL9117M is
571kHz. ZL9117M will only read the SYNC pin connection during
the start-up sequence. Changes to the SYNC pin connections will
not affect fSW until the power (VDD) is cycled off and on.
TABLE 2. SWITCHING FREQUENCY SELECTION
SYNC PIN
FREQUENCY
LOW
400kHz
OPEN
571kHz
HIGH
1MHz
Resistor
See Table 3
If the user desires to configure other frequencies not listed in
Tables 2 or 3, the switching frequency can also be set to any
value between 400kHz and 1MHz using the I2C/SMBus
interface.
TABLE 3. RSYNC RESISTOR VALUES
synchronize with each other. One of the devices must be
configured as a Sync source and the remaining devices must be
configured as a Sync input. The I2C/SMBus must be used to
configure the Sync pin.
NOTE: The switching frequency read back using the appropriate
PMBus command will differ slightly from the selected values in
Tables 2 and 3. The difference is due to hardware quantization.
Loop Compensation
The ZL9117M operates as a voltage-mode synchronous buck
controller with a fixed frequency PWM scheme. The module is
internally compensated via the I2C/SMBus interface.
The ZL9117M has an auto compensation feature that measures
the characteristics of the power train and calculates the proper
tap coefficients. By default, auto compensation is configured to
execute one time after ramp with 50% auto compensation Gain
with Power-Good asserted immediately after the first auto
compensation cycle completes.
Adaptive Diode Emulation
Adaptive diode emulation mode turns off the low-side FET gate
drive at low load currents to prevent the inductor current from
going negative, reducing the energy losses and increasing overall
efficiency. Diode emulation is available to single-phase devices
only.
Note: the overall bandwidth of the device may be reduced when
in diode emulation mode. Disabling the diode emulation prior to
applying significant load steps is recommended.
Input Undervoltage Lockout
The input undervoltage lockout (UVLO) prevents the ZL9117M
from operating when the input falls below a preset threshold,
indicating the input supply is out of its specified range. The UVLO
threshold (VUVLO) can be set between 2.85V and 16V using the
I2C/SMBus interface.
RSYNC (kΩ)
FREQUENCY (kHz)
19.6, or connect to SGND
400
21.5
421
23.7
471
1. Continue operating without interruption.
26.1
533
28.7, or Open
571
2. Continue operating for a given delay period, followed by
shutdown if the fault still exists. The device remains in
shutdown until instructed to restart.
31.6
615
34.8
727
37.3
800
46.4
889
51.1, or connect to V25 or VR
1000
If a value other than fSW = 8MHz/N is entered using a PMBus
command, the internal circuitry will select the switching
frequency value using N as a whole number to achieve a value
close to the entered value. For example, if 810kH is entered, the
device will select 800kHz (N = 10).
When multiple Intersil digital devices are used together,
connecting the SYNC pins together will force all devices to
Submit Document Feedback
12
Once an input undervoltage fault condition occurs, the device
can respond in a number of ways, as follows:
3. Initiate an immediate shutdown until the fault is cleared. The
user can select a specific number of retry attempts.
The default response from a UVLO fault is an immediate
shutdown of the module. The controller continuously checks for
the presence of the fault condition. If the fault condition is no
longer present, the ZL9117M is re-enabled.
Output Overvoltage Protection
The ZL9117M offers an internal output overvoltage protection
circuit that can be used to protect sensitive load circuitry from
being subjected to a voltage higher than its prescribed limits. A
hardware comparator is used to compare the actual output
voltage (seen at the FB+ pin) to a threshold set to 15% higher
than the target output voltage (the default setting). If the FB+
FN7914.4
December 16, 2014
ZL9117M
voltage exceeds this threshold, the PG pin de-asserts, and the
controller can then respond in a number of ways, as follows:
1. Initiate an immediate shutdown until the fault is cleared. The
user can select a specific number of retry attempts.
2. Turn off the high-side MOSFET and turn on the low-side
MOSFET. The low-side MOSFET remains ON until the device
attempts a restart.
The default response from an overvoltage fault is to immediately
shut down. The controller continuously checks for the presence
of the fault condition, and when the fault condition no longer
exists, the device is re-enabled.
For continuous overvoltage protection when operating from an
external clock, the only allowed response is an immediate
shutdown.
Output Prebias Protection
An output prebias condition exists when an externally applied
voltage is present on a power supply’s output before the power
supply’s control IC is enabled. Certain applications require that
the converter not be allowed to sink current during start-up if a
prebias condition exists at the output. The ZL9117M provides
prebias protection by sampling the output voltage prior to
initiating an output ramp.
If a prebias voltage lower than the target voltage exists after the
pre-configured delay period has expired, the target voltage is set
to match the existing prebias voltage, and both drivers are
enabled. The output voltage is then ramped to the final
regulation value at the preconfigured ramp rate.
The actual time the output takes to ramp from the prebias
voltage to the target voltage varies, depending on the prebias
voltage, however, the total time elapsed from when the delay
period expires and when the output reaches its target value will
match the pre-configured ramp time (see Figure 13).
FIGURE 13. OUTPUT RESPONSES TO PREBIAS VOLTAGES
If a prebias voltage higher than the target voltage exists after the
pre-configured delay period has expired, the target voltage is set
to match the existing prebias voltage, and both drivers are
enabled with a PWM duty cycle that would ideally create the
pre-bias voltage.
Once the pre-configured soft-start ramp period has expired, the
PG pin is asserted (assuming the prebias voltage is not higher
than the overvoltage limit). The PWM then adjusts its duty cycle
to match the original target voltage, and the output ramps down
to the preconfigured output voltage.
If a prebias voltage higher than the overvoltage limit exists, the
device does not initiate a turn-on sequence and declares an
overvoltage fault condition to exist. In this case, the device
responds based on the output overvoltage fault response method
that has been selected. See “Output Overvoltage Protection” on
page 12 for response options due to an overvoltage condition.
Note that prebias protection is not offered for current sharing
groups that also have tracking enabled. VDD must be tied to VIN
for proper prebias start-up in single module operation.
Output Overcurrent Protection
The ZL9117M can protect the power supply from damage if the
output is shorted to ground or if an overload condition is imposed
on the output. The following overcurrent protection response
options are available:
1. Initiate a shutdown and attempt to restart an infinite number
of times with a preset delay period between attempts.
2. Initiate a shutdown and attempt to restart a preset number of
times with a preset delay period between attempts.
Submit Document Feedback
13
FN7914.4
December 16, 2014
ZL9117M
3. Continue operating for a given delay period, followed by
shutdown if the fault still exists.
4. Continue operating through the fault (this could result in
permanent damage to the power supply).
5. Initiate an immediate shutdown.
The default response from an overcurrent fault is an immediate
shutdown of the controller. The controller continuously checks for
the presence of the fault condition, and if the fault condition no
longer exists, the device is re-enabled.
Thermal Overload Protection
The ZL9117M includes a thermal sensor that continuously
measures the internal temperature of the module and shuts
down the controller when the temperature exceeds the preset
limit. The default temperature limit is set to +125°C in the
factory, but the user may set the limit to a different value if
desired. Note that setting a higher thermal limit via the
I2C/SMBus interface may result in permanent damage to the
controller. Once the module has been disabled due to an internal
temperature fault, the user may select one of several fault
response options as follows:
1. Initiate a shutdown and attempt to restart an infinite number
of times with a preset delay period between attempts.
2. Initiate a shutdown and attempt to restart a preset number of
times with a preset delay period between attempts.
3. Continue operating for a given delay period, followed by
shutdown if the fault still exists.
4. Continue operating through the fault (this could result in
permanent damage to the power supply).
5. Initiate an immediate shutdown.
If the user has configured the module to restart, the controller
waits the preset delay period (if configured to do so) and then
checks the module temperature. If the temperature has dropped
below a threshold that is approximately +15°C lower than the
selected temperature fault limit, the controller attempts to
re-start. If the temperature still exceeds the fault limit, the
controller waits the preset delay period and retries again.
The default response from a temperature fault is an immediate
shutdown of the module. The controller continuously checks for
the fault condition, and once the fault has cleared, the ZL9117M
is re-enabled.
TABLE 4. SMBus ADDRESS RESISTOR SELECTION (Continued)
RSA (kΩ)
SMBus ADDRESS
14.7
0x1D
16.2
0x1E
17.8
0x1F
19.6
0x20
21.5
0x21
23.7
0x22
26.1, or connect to SGND
0x23
28.7, or Open
0x24
31.6, or connect to V25 or VR
0x25
34.8
0x26
38.3
0x27
42.2
0x28
46.4
0x29
51.1
0x2A
56.2
0x2B
61.9
0x2C
68.1
0x2D
75
0x2E
82.5
0x2F
90.9
0x30
100
0x31
Digital-DC Bus
The Digital-DC Communications (DDC) bus is used to
communicate between Intersil digital modules and devices. This
dedicated bus provides the communication channel between
devices for features such as sequencing, fault spreading, and
current sharing. The DDC pin on all Digital-DC devices in an
application should be connected together. A pull-up resistor is
required on the DDC bus in order to guarantee the rise time as
shown in Equation 1:
(EQ. 1)
I2C/SMBus Module Address Selection
Rise Time = R PU C LOAD  1s
Each module must have its own unique serial address to
distinguish between other devices on the bus. The module
address is set by connecting a resistor between the SA pin and
SGND. Table 4 lists the available module addresses.
where RPU is the DDC bus pull-up resistance and CLOAD is the
bus loading. The pull-up resistor may be tied to an external 3.3V
or 5V supply as long as this voltage is present prior to or during
device power-up. As rules of thumb, each device connected to the
DDC bus presents approximately 10pF of capacitive loading, and
each inch of FR4 PCB trace introduces approximately 2pF. The
ideal design uses a central pull-up resistor that is well-matched
to the total load capacitance. The minimum pull-up resistance
should be limited to a value that enables any device to assert the
bus to a voltage that ensures a logic 0 (typically 0.8V at the
device monitoring point), given the pull-up voltage and the
pull-down current capability of the ZL9117M (nominally 4mA).
TABLE 4. SMBus ADDRESS RESISTOR SELECTION
RSA (kΩ)
SMBus ADDRESS
10
0x19
11
0x1A
12.1
0x1B
13.3
0x1C
Submit Document Feedback
14
FN7914.4
December 16, 2014
ZL9117M
Phase Spreading
To enable phase spreading, all converters must be synchronized
to the same switching clock. The phase offset of each device
may also be set to any value between 0° and 360° in 22.5°
increments via the I2C/SMBus interface.
Output Voltage Tracking
High performance systems place stringent demands on the order
in which the power supply voltages turn on. This is particularly
true when powering FPGAs, ASICs, and other advanced processor
devices that require multiple supply voltages to power a single
die. In most cases, the I/O interface operates at a higher voltage
than the core and therefore the core supply voltage must not
exceed the I/O supply voltage according to the manufacturers'
specifications. Voltage tracking protects these sensitive ICs by
limiting the differential voltage among multiple power supplies
during the power-up and power-down sequence.
0
Vm em
Vref =1.8V
Vmem=0.9V
To ff D ly
Track @ 100% Vtrk Limited
Vref = Vmem VR ef
~
EN
A.
V mem
Vref =1.8V
Vmem=1.8V
T off D ly
Ton D ly
0
EN
B.
FIGURE 15. COINCIDENT TRACKING
Ratiometric: This mode configures the ZL9117M to ramp its
output voltage as a percentage of the voltage applied to the
VTRK pin. The default setting is 50%, but an external resistor or
PMBus command may be used to configure a different tracking
ratio.
a. Track at 50% VOUT limited. Member rail tracks the
reference rail and stops when the member reaches
50% of the target voltage, Figure 16(A).
b. Track at 50% VTRK limited. Member rail tracks the
reference at the instantaneous voltage value applied
to the VTRK pin until the member rail reaches 50% of
the reference rail voltage, or if the member is
configured to less than 50% of the reference the
member will achieve its configured target,
Figure 16(B).
The ZL9117M integrates a lossless tracking scheme that allows
its output to track a voltage that is applied to the VTRK pin with
no additional components required. The VTRK pin is an analog
input that, when tracking mode is enabled, and configures the
voltage applied to the VTRK pin to act as a reference for the
member device's output regulation.
Voltage tracking can be configured by PMBus only. An example is
shown in Figure 14.
To n Dly
~~
Coincident Tracking
Track @ 1 00% Vout Limited
VR ef
Vref > Vmem
Ratiom etric Tracking
Tra ck @ 50% Vou t Limited
Vref = 1.8V
V R ef
Vmem = 0.9 V
To n Dly
0
SCL
~~
When multiple point-of-load converters share a common DC
input supply, it is desirable to adjust the clock phase offset of
each device such that not all devices start to switch
simultaneously. Setting each converter to start its switching cycle
at a different point in time, can dramatically reduce input
capacitance requirements and efficiency losses. Since the peak
current drawn from the input supply is effectively spread out over
a period of time, the peak current drawn at any given moment is
reduced, and the power losses proportional to the IRMS2 are
reduced dramatically.
b. Track at 100% VTRK limited. Member rail tracks the
reference at the instantaneous voltage value applied
to the VTRK pin, Figure 15(B).
V me m
Vref=1.8V
Vmem=0.9V
Toff Dly
Track @ 50% V trk Limited
V ref = 1.8V
SDA
Vref
SDA
SCL
Vmem
SDA
VTRK
VOUT
V mem = 0.8 V
SCL
VOUT
V ref
To n Dly
0
~~
EN
A.
Vm em
Toff Dly
Vref=1.8V
Vmem=0.8V
EN
B.
ZL9117M
ZL9117M
FIGURE 16. RATIOMETRIC TRACKING
FIGURE 14. PMBUS TRACKING CONFIGURATION
The ZL9117M offers two modes of tracking: coincident and
ratiometric. Figures 15 and 16 illustrate the output voltage
waveform for the two tracking modes.
Coincident: This mode configures the ZL9117M to ramp its
output voltage at the same rate as the voltage applied to the
VTRK pin. Two options are available for this mode:
a. Track at 100% VOUT limited. Member rail tracks the
reference rail and stops when the member reaches
its target voltage, Figure 15(A).
Submit Document Feedback
15
Output Sequencing
A group of Digital-DC modules or devices may be configured to
power-up in a predetermined sequence. This feature is especially
useful when powering advanced processors, FPGAs and ASICs
that require one supply to reach its operating voltage; prior to
another supply reaching its operating voltage in order to avoid
latch-up. Multi-device sequencing can be achieved by configuring
each device through the I2C/SMBus interface.
Multiple device sequencing is configured by issuing PMBus
commands to assign the preceding device in the sequencing
chain as well as the device that follows in the sequencing chain.
FN7914.4
December 16, 2014
ZL9117M
The Enable pins of all devices in a sequencing group must be tied
together and driven high to initiate a sequenced turn-on of the
group. Enable must be driven low to initiate a sequenced turnoff
of the group.
VREFERENCE
Fault Spreading
Active Current Sharing
VOUT
-R
Digital DC modules and devices can be configured to broadcast a
fault event over the DDC bus to the other devices in the group.
When a non-destructive fault occurs and the device is configured
to shut down on a fault, the device shuts down and broadcasts
the fault event over the DDC bus. The other devices on the DDC
bus shut down simultaneously and attempt to re-start in their
prescribed order, if configured to do so.
VMEMBER
-R
I MEMBER
Paralleling multiple ZL9117M modules can be used to increase
the output current capability of a single power rail. By connecting
the DDC pins of each module together and configuring the
modules as a current sharing rail, the units share the current
equally within a few percent. Figure 17 illustrates a typical
connection for two modules.
I OUT
I REFERENCE
FIGURE 18. ACTIVE CURRENT SHARING
Figure 18 shows that, for load lines with identical slopes, the
member voltage is increased towards the reference voltage,
which closes the gap between the inductor currents.
The relation between reference and member current and voltage
is given by Equation 2:
.
VIN
3.3V TO 5V
V MEMBER = V OUT + R   I REFERENCE – I MEMBER 
CIN
(EQ. 2)
where R is the value of the droop resistance.
DDC ZL9117M
The ISHARE_CONFIG command is used to configure the module
for active current sharing. The default setting is a stand-alone
non-current sharing module. A current sharing rail can be part of
a system sequencing group.
COUT
CIN
DDC ZL9117M
VOUT
COUT
FIGURE 17. CURRENT SHARING GROUP
The ZL9117M uses a low-bandwidth, first-order digital current
sharing technique to balance the unequal module output loading
by aligning the load lines of member modules to a reference
module.
Droop resistance is used to add artificial resistance in the output
voltage path to control the slope of the load line curve,
calibrating out the physical parasitic mismatches due to power
train components and PCB layout.
Upon system start-up, the module with the lowest member
position as selected in ISHARE_CONFIG is defined as the
reference module. The remaining modules are members. The
reference module broadcasts its current over the DDC bus. The
members use the reference current information to trim their
voltages (VMEMBER) to balance the current loading of each
module in the system.
For fault configuration, the current share rail is configured in a
quasi-redundant mode. In this mode, when a member module
fails, the remaining members continue to operate and attempt to
maintain regulation. Of the remaining modules, the module with
the lowest member position becomes the reference. If fault
spreading is enabled, the current share rail failure is not
broadcast until the entire current share rail fails.
The phase offset of (multi-phase) current sharing modules is
automatically set to a value between 0° and 337.5° in 22.5°
increments as in Equation 3:
Phase Offset = SMBus Address  4:0  – Current
Share Position 22.5
(EQ. 3)
Please refer to Application Note AN2034 for additional details on
current sharing.
Phase Adding/Dropping
The ZL9117M allows multiple power converters to be connected
in parallel to supply higher load currents than can be addressed
using a single-phase design. In doing so, the power converter is
optimized at a load current range that requires all phases to be
operational. During periods of light loading, it may be beneficial
to disable one or more phases to eliminate the current drain and
switching losses associated with those phases, resulting in
higher efficiency.
The ZL9117M offers the ability to add and drop phases using a
PMBus command in response to an observed load current
Submit Document Feedback
16
FN7914.4
December 16, 2014
ZL9117M
change. All phases in a current share rail are considered active
prior to the current sharing rail ramp to power-good.
Any member of the current sharing rail can be dropped. If the
reference module is dropped, the remaining active module with
the lowest member position becomes the new reference.
Additionally, any change to the number of members of a current
sharing rail will precipitate autonomous phase distribution within
the rail where all active phases realign their phase position
based on their order within the number of active members.
If the members of a current sharing rail are forced to shut down
due to an observed fault, all members of the rail attempt to
re-start simultaneously after the fault has cleared.
Monitoring via I2C/SMBus
A system controller can monitor a wide variety of different
ZL9117M system parameters through the I2C/SMBus interface.
The module can monitor for any number of power conversion
parameters including but not limited to the following:
• Input voltage/Output voltage
DATA
VALUE
DESCRIPTION
1
Copies current SNAPSHOT values from Flash memory to
RAM for immediate access using SNAPSHOT command.
2
Writes current SNAPSHOT values to Flash memory. Only
available when device is disabled.
It should be noted that the device's VDD voltage must be
maintained during the time when the device is writing the data to
flash memory; a process that requires up to 1400µs. Undesirable
results may be observed if the device's VDD supply drops below
3.0V during the process.
The following is a recommended procedure for using the
SnapShot parameter capture after a fault:
1. Configure the module using config file (optional)
2. Enable the SnapShot mode by setting bit 1 of MISC_CONFIG
command to 1. This can be done before or after the module
is enabled. Note: do not store MISC_CONFIG: SNAPSHOT
setting in default/user store.
3. At this point the module starts capturing operational
parameters in RAM for SNAPSHOT, in every firmware cycle.
• Output current
• Internal temperature
4. The module is configured to capture operational parameters
after a fault during operation.
• Switching frequency
• Duty cycle
Snapshot Parameter Capture
The ZL9117M offers a special feature that enables the user to
capture parametric data during normal operation or following a
fault. The Snapshot functionality is enabled by setting Bit 1 of the
MISC_CONFIG command to 1. The SnapShot feature enables the
user to read parameters via a block read transfer through the
SMBus. This can be done during normal operation, although it
should be noted that reading the 32 bytes occupies the SMBus
for a period of time.
The SNAPSHOT_CONTROL command enables the user to store
the SnapShot parameters to flash memory in response to a
pending fault, as well as to read the stored data from flash
memory after a fault has occurred. In order to read the stored
data from flash memory, two conditions must apply:
1. The module should be disabled.
2. SnapShot mode should be disabled by changing Bit 1 of
MISC_CONFIG to 0. This is to prevent firmware from updating
RAM values after the fault with current values.
Table 5 describes the usage of SNAPSHOT_CONTROL command.
Automatic writes to flash memory following a fault are triggered
when any fault threshold level is exceeded, provided that the
specific fault's response is to shut down (writing to flash memory
is not allowed if the device is configured to retry following the
specific fault conditions).
Submit Document Feedback
TABLE 5. SNAPSHOT_CONTROL COMMAND
17
5. After the fault, disable the SnapShot mode by setting Bit 1 of
MISC_CONFIG command to 0. This is to prevent the firmware
from updating RAM values after the fault with current values.
6. Disable the module.
7. Send SNAPSHOT_CONTROL command 1 to read the stored
data from flash memory into RAM at any time. Issue a
SNAPSHOT command to read the data from RAM via SMBus.
8. Repeat Step 7 to retrieve SNAPSHOT parameters after a
power cycle. It is important to make sure SnapShot mode is
disabled in the MISC_CONFIG command.
Non-Volatile Memory and Device Security
Features
The ZL9117M has internal non-volatile memory where user
configurations are stored. Integrated security measures ensure
that the user can only restore the module to a level that has been
made available to them.
During the initialization process, the ZL9117M checks for stored
values contained in its internal non-volatile memory. The
ZL9117M offers two internal memory storage units that are
accessible by the user as follows:
1. Default Store: The ZL9117M has a default configuration that is
stored in the default store in the controller. The module can be
restored to its default settings by issuing a
RESTORE_DEFAULT_ALL command over the SMBus.
2. User Store: The user can modify certain power supply settings
as described in this data sheet. The user stores their
configuration in the user store.
FN7914.4
December 16, 2014
ZL9117M
OUTPUT CAPACITOR SELECTION
Several trade-offs must also be considered when selecting an
output capacitor. Low ESR values are needed to have a small
output deviation during transient load steps (Vosag) and low
output voltage ripple (Vorip). However, capacitors with low ESR,
such as semi-stable (X5R and X7R) dielectric ceramic capacitors,
also have relatively low capacitance values. Many designs can
use a combination of high capacitance devices and low ESR
devices in parallel.
For high ripple currents, a low capacitance value can cause a
significant amount of output voltage ripple. Likewise, in high
transient load steps, a relatively large amount of capacitance is
needed to minimize the output voltage deviation while the
inductor current ramps up or down to the new steady state
output current value.
As a starting point, apportion one-half of the output ripple
voltage to the capacitor ESR and the other half to capacitance, as
shown in Equations 4 and 5:
I L  P-P 
C OUT = --------------------------------------V orip
8  f sw  -------------2
(EQ. 4)
(EQ. 5)
V orip
ESR = --------------------------2  I L  P-P 
current, which can cause premature failure. Ceramic capacitors
with X7R or X5R dielectric with low ESR and 1.1x the maximum
expected input voltage are recommended.
Layout Guide
To achieve stable operation, low losses, and good thermal
performance some layout considerations are necessary.
• Establish a separate ground plane for SGND (pin 9) and PGND
(pin 10 and pin 16) and connect them at a single point as
shown in the Figure 19. CV25, CVR, RSA, and RVSET are
placed on the bottom layer and are connected to a single
SGND plane that is connected to the PGND at a single point.
This will help to block the high frequency noise from entering
to the controller via SGND.
• Place a high frequency ceramic capacitor between (1) VIN and
PGND (pin 16), (2) VOUT and PGND (pin 16) and (3) bypass
capacitors between VDRV, VDD, V25, VR and the ground plane,
as close to the module as possible to minimize high frequency
noise. High frequency ceramic capacitors close to the module
between VOUT and PGND will help to minimize noise at the
output ripple.
• Use large copper areas for power path (VIN, PGND, VOUT) to
minimize conduction loss and thermal stress. Also, use
multiple vias to connect the power planes in different layers.
After a capacitor has been selected, the resulting output voltage
ripple can be calculated using Equation 6:
• Connect remote sensed traces to the regulation point to
achieve a tight output voltage regulation, and keep them in
parallel. Route a trace from FB- to a location near the load
ground, and a trace from FB+ to the point-of-load where the
tight output voltage is desired.
I L  P-P 
V orip = I L  P-P   ESR + ------------------------------------8  f sw  C out
• Avoid routing any sensitive signal traces, such as the VOUT,
FB+, FB- sensing point near the PHASE pin.
Because each part of this equation was made to be less than or
equal to half of the allowed output ripple voltage, the Vorip should
be less than the desired maximum output ripple.
PG
S Y NC
SA
S CL
8
7
6
5
4
3
2
RSA
CVR
SGND
PGND
Usually, at higher output voltages, inductor ripple current is very
high so it is recommend to use a combination of several ceramic
capacitor with low ESR bulk capacitors to ensure low output
ripple voltage and loop stability. Inadequate amount of
capacitance at the output can cause instability to the control
loop.
EN
SG N D
RVSET
VR
(EQ. 6)
DDC
Use these values to make an initial capacitor selection, using a
single capacitor or several capacitors in parallel.
9
SDA
VSET
PGND
10
21
V25
11
20
VTRK
CVDD VDD
12
19
FB+
TO
VOUT
CVDRV
13 VDRV
18
FB-
TO
LOAD GND
CV25
SW
14
INPUT CAPACITOR
VOUT
17
It is highly recommended that dedicated input capacitors be
used in any point-of-load design, even when the supply is
powered from a heavily filtered 5V or 12V “bulk” supply from an
off-line power supply. This is because of the high RMS ripple
current that is drawn by the buck converter topology. This ripple
(ICINrms) can be determined from Equation 7:
(EQ. 7)
I CINrms = I OUT  D   1 – D 
Without capacitive filtering near the power supply circuit, this
current would flow through the supply bus and return planes,
coupling noise into other system circuitry. The input capacitors
should be rated at 1.2x the ripple current calculated in Equation 7
to avoid overheating of the capacitors due to the high ripple
Submit Document Feedback
1
18
VIN
15
PGND
16
CIN
COUT
FIGURE 19. RECOMMENDED LAYOUT
Thermal Consideration
Experimental power loss curves along with θJA from thermal
modeling analysis can be used to evaluate the thermal
consideration for the module. The derating curves are derived
from the maximum power allowed while maintaining the
FN7914.4
December 16, 2014
ZL9117M
temperature below the maximum junction temperature of
+125°C. In actual application, other heat sources and design
margin should be considered.
Package Description
The structure of the ZL9117M belongs to the Quad Flat-pack
No-lead package (QFN). This kind of package has advantages,
such as good thermal and electrical conductivity, low weight and
small size. The QFN package is applicable for surface mounting
technology and is being more readily used in the industry. The
ZL9117M contains several types of devices, including resistors,
capacitors, inductors and control ICs. The ZL9117M is a copper
lead-frame based package with exposed copper thermal pads,
which have good electrical and thermal conductivity. The copper
lead frame and multi component assembly is overmolded with
polymer mold compound to protect these devices.
The package outline and typical PCB layout pattern design and
typical stencil pattern design are shown on the second page of
the package outline drawing L21.15x15 on page 58. The module
has a small size of 15mmx15mmx3.5mm. Figure 20 shows
typical reflow profile parameters. These guidelines are general
design rules. Users could modify parameters according to their
application.
stencil pattern is shown on the second page of the Package
Outline Drawing L21.15x15 on page 58. The gap width between
pad to pad is 0.6mm. The user should consider the symmetry of
the whole stencil pattern when designing its pads. A laser cut,
stainless steel stencil with electropolished trapezoidal walls is
recommended. Electropolishing “smooths” the aperture walls
resulting in reduced surface friction and better paste release which
reduces voids. Using a Trapezoidal Section Aperture (TSA) also
promotes paste release and forms a "brick like" paste deposit that
assists in firm component placement. A 0.1mm to 0.15mm stencil
thickness is recommended for this large pitch (1.3mm) QFN.
Reflow Parameters
Due to the low mount height of the QFN, "No Clean" Type 3 solder
paste per ANSI/J-STD-005 is recommended. Nitrogen purge is
also recommended during reflow. A system board reflow profile
depends on the thermal mass of the entire populated board, so it
is not practical to define a specific soldering profile just for the
QFN. The profile given in Figure 20 is provided as a guideline, to
be customized for varying manufacturing practices and
applications.
300
PCB Layout Pattern Design
Thermal Vias
250
TEMPERATURE (°C)
The bottom of ZL9117M is a lead-frame footprint, which is
attached to the PCB by surface mounting process. The PCB
layout pattern is shown on the second page of the Package
Outline Drawing L21.15x15 on page 58. The PCB layout pattern is
essentially 1:1 with the QFN exposed pad and I/O termination
dimensions, except for the PCB lands being a slightly extended
distance of 0.2mm (0.4mm max) longer than the QFN
terminations, which allows for solder filleting around the
periphery of the package. This ensures a more complete and
inspectable solder joint. The thermal lands on the PCB layout
should match 1:1 with the package exposed die pads.
PEAK TEMPERATURE ~+245°C;
TYPICALLY 60s-150s ABOVE +217°C
KEEP LESS THAN 30s WITHIN 5°C OF PEAK TEMP.
200
SLOW RAMP (3°C/s MAX)
AND SOAK FROM +150°C
TO +200°C FOR 60s~180s
150
100
RAMP RATE 1.5°C FROM +70°C TO +90°C
50
0
0
100
150
200
250
300
350
DURATION (s)
A grid of 1.0mm to 1.2mm pitch thermal vias, which drops down
and connects to buried copper plane(s), should be placed under
the thermal land. The vias should be about 0.3mm to 0.33mm in
diameter with the barrel plated to about 1.0 ounce copper.
Although adding more vias (by decreasing via pitch) will improve
the thermal performance, diminishing returns will be seen as
more and more vias are added. Simply use as many vias as
practical for the thermal land size and your board design rules
allow.
FIGURE 20. TYPICAL REFLOW PROFILE
Stencil Pattern Design
Reflowed solder joints on the perimeter I/O lands should have
about a 50µm to 75µm (2mil to 3mil) standoff height. The solder
paste stencil design is the first step in developing optimized,
reliable solder joints. Stencil aperture size to land size ratio
should typically be 1:1. The aperture width may be reduced slightly
to help prevent solder bridging between adjacent I/O lands. To
reduce solder paste volume on the larger thermal lands, it is
recommended that an array of smaller apertures be used instead
of one large aperture. It is recommended that the stencil printing
area cover 50% to 80% of the PCB layout pattern. A typical solder
Submit Document Feedback
19
FN7914.4
December 16, 2014
ZL9117M
PMBus Command Summary
COMMAND
CODE
COMMAND NAME
DESCRIPTION
TYPE
DATA
FORMAT
DEFAULT
VALUE
DEFAULT
SETTING
PAGE
01h
OPERATION
Sets Enable, Disable and VOUT
Margin modes.
R/W BYTE
BIT
page 24
02h
ON_OFF_CONFIG
Configures device to enable from
EN pin or OPEARTION command.
R/W BYTE
BIT
03h
CLEAR_FAULTS
Clear fault indications
SEND BYTE
page 25
11h
STORE_DEFAULT_ALL
Stores all PMBus values written
since last restore at default level.
SEND BYTE
page 25
12h
RESTORE_DEFAULT_ALL
Restores PMBus settings that
were stored at default level.
SEND BYTE
page 25
15h
STORE_USER_ALL
Stores all PMBus values written
since last restore at user level.
SEND BYTE
page 25
16h
RESTORE_USER_ALL
Restores PMBus settings that
were stored in user level.
SEND BYTE
page 26
20h
VOUT_MODE
Preset to defined data format of
VOUT commands.
READ BYTE
BIT
16h
13h
Pin Enable
Soft Off
page 25
Linear Mode,
Exponent = -13
page 26
21h
VOUT_COMMAND
Sets the nominal value of VOUT.
R/W WORD
L16u
Pin Strap
page 26
22h
VOUT_TRIM
Sets trim value on VOUT.
R/W WORD
L16s
0000h
0V
page 26
23h
VOUT_CAL_OFFSET
Applies a fixed offset voltage to
the VOUT_COMMAND.
R/W WORD
L16s
0000h
0V
page 26
24h
VOUT_MAX
Sets the maximum possible value
of VOUT.
R/W WORD
L16u
1.1*VOUT
Pin Strap
page 26
25h
VOUT_MARGIN_HIGH
Sets the value of the VOUT during
a margin high.
R/W WORD
L16u
1.05*VOUT
Pin Strap
page 27
26h
VOUT_MARGIN_LOW
Sets the value of the VOUT during
a margin low.
R/W WORD
L16u
0.95*VOUT
Pin Strap
page 27
27h
VOUT_TRANSITION_RATE
Sets the transition rate during
margin or other change of VOUT.
R/W WORD
L11
BA00h
1V/ms
page 27
28h
VOUT_DROOP
Sets the loadline (V/I Slope)
resistance for the rail.
R/W WORD
L11
0000h
0mV/A
page 27
32h
MAX_DUTY
Sets the maximum allowable
duty cycle.
R/W WORD
L11
EADBh
91.375%
page 27
33h
FREQUENCY_SWITCH
Sets the switching frequency.
R/W WORD
L11
Pin Strap
page 28
37h
INTERLEAVE
Sets a phase offset between
devices sharing a SYNC clock.
R/W WORD
BIT
Set based on
PMBus Address
page 28
38h
IOUT_CAL_GAIN
Sense resistance for inductor
DCR current sensing.
R/W WORD
L11
BA2Ah
1.083mΩ
page 28
39h
IOUT_CAL_OFFSET
Sets the current-sense offset.
R/W WORD
L11
BE00h
-1A
page 28
40h
VOUT_OV_FAULT_LIMIT
Sets the VOUT overvoltage fault
threshold.
R/W WORD
L16u
1.15 * VOUT
Pin Strap
page 28
41h
VOUT_OV_FAULT_RESPONSE
Configures the VOUT overvoltage
fault response.
R/W BYTE
BIT
44h
VOUT_UV_FAULT_LIMIT
Sets the VOUT undervoltage fault
threshold.
R/W WORD
L16u
45h
VOUT_UV_FAULT_RESPONSE
Configures the VOUT undervoltage
fault response.
R/W BYTE
BIT
80h
46h
IOUT_OC_FAULT_LIMIT
Sets the IOUT peak overcurrent
fault threshold.
R/W WORD
L11
4Bh
IOUT_UC_FAULT_LIMIT
Sets the IOUT valley undercurrent
fault threshold.
R/W WORD
4Fh
OT_FAULT_LIMIT
Sets the over-temperature fault
threshold.
R/W WORD
Submit Document Feedback
20
80h
page 29
0.85*VOUT
Pin Strap
page 29
Disable and
No Retry
page 29
E250h
37A
page 30
L11
E5B0h
-37A
page 30
L11
EBE8h
125°C
page 30
FN7914.4
December 16, 2014
ZL9117M
PMBus Command Summary (Continued)
COMMAND
CODE
COMMAND NAME
DESCRIPTION
TYPE
DATA
FORMAT
DEFAULT
VALUE
R/W BYTE
BIT
80h
50h
OT_FAULT_RESPONSE
Configures the over-temperature
fault response.
51h
OT_WARN_LIMIT
Sets the over-temperature
warning limit.
R/W WORD
L11
52h
UT_WARN_LIMIT
Sets the under-temperature
warning limit.
R/W WORD
53h
UT_FAULT_LIMIT
Sets the under-temperature fault
threshold.
54h
UT_FAULT_RESPONSE
Configures the undertemperature fault response.
55h
VIN_OV_FAULT_LIMIT
56h
DEFAULT
SETTING
PAGE
Disable and
No Retry
page 30
Eb70h
+110°C
page 31
L11
E4E0h
-50°C
page 31
R/W WORD
L11
E490h
-55°C
page 31
R/W BYTE
BIT
80h
Disable and
No Retry
page 31
Sets the VIN overvoltage fault
threshold.
R/W WORD
L11
D3A0h
14.5V
page 32
VIN_OV_FAULT_RESPONSE
Configures the VIN overvoltage
fault response.
R/W BYTE
BIT
80h
Disable and
No Retry
page 32
57h
VIN_OV_WARN_LIMIT
Sets the VIN overvoltage warning
limit.
R/W WORD
L11
D34Dh
13.2V
page 33
58h
VIN_UV_WARN_LIMIT
Sets the VIN undervoltage fault
threshold.
R/W WORD
L11
CA30h
4.38V
page 33
59h
VIN_UV_FAULT_LIMIT
Sets the VIN undervoltage
warning limit.
R/W WORD
L11
CA00h
4V
page 33
5Ah
VIN_UV_FAULT_RESPONSE
Configures the VIN undervoltage
fault response.
R/W BYTE
BIT
80h
Disable and
No Retry
page 33
5Eh
POWER_GOOD_ON
Sets the voltage threshold for
Power Good indication.
R/W WORD
L16u
0.9*VOUT
Pin Strap
page 34
60h
TON_DELAY
Sets the delay time from ENABLE
to start of VOUT rise.
R/W WORD
L11
CA80h
5ms
page 34
61h
TON_RISE
Sets the rise time of VOUT after
ENABLE and TON_DELAY.
R/W WORD
L11
D280h
10ms
page 34
64h
TOFF_DELAY
Sets the delay time from DISABLE
to START of VOUT fall.
R/W WORD
L11
CA80h
5ms
page 34
65h
TOFF_FALL
Sets the fall time of VOUT after
DISABLE and TOFF_DELAY.
R/W WORD
L11
D280h
10ms
page 34
78h
STATUS_BYTE
Summary of most critical faults
79h
STATUS_WORD
Summary of critical faults
READ BYTE
BIT
00h
No faults
page 34
READ WORD
BIT
0000h
No faults
page 35
7Ah
STATUS_VOUT
Reports VOUT warnings/faults
READ BYTE
BIT
00h
No faults
page 35
7Bh
STATUS_IOUT
Reports IOUT warnings/faults
READ BYTE
BIT
00h
No faults
page 36
7Ch
STATUS_INPUT
Reports input warnings/faults
READ BYTE
BIT
00h
No faults
page 36
7Dh
STATUS_TEMPERATURE
Reports temperature
warnings/faults
READ BYTE
BIT
00h
No faults
page 36
7Eh
STATUS_CML
Reports Communication,
memory, logic errors
READ BYTE
BIT
00h
No faults
page 37
80h
STATUS_MFR_SPECIFIC
Reports voltage monitoring/clock
sync faults
READ BYTE
BIT
00h
No faults
page 37
88h
READ_VIN
Reports input voltage
measurement
READ WORD
L11
page 37
8Bh
READ_VOUT
Reports input current
measurement
READ WORD
L16u
page 37
8Ch
READ_IOUT
Reports output current
measurement
READ WORD
L11
page 38
8Dh
READ_TEMPERATURE_1
Reports temperature reading
internal to the device
READ WORD
L11
page 38
Submit Document Feedback
21
FN7914.4
December 16, 2014
ZL9117M
PMBus Command Summary (Continued)
COMMAND
CODE
COMMAND NAME
DESCRIPTION
TYPE
DATA
FORMAT
DEFAULT
VALUE
DEFAULT
SETTING
PAGE
94h
READ_DUTY_CYCLE
Reports actual duty cycle
READ WORD
L11
page 38
95h
READ_FREQUENCY
Reports actual switching
frequency
READ WORD
L11
page 38
98h
PMBUS_REVISION
Returns the revision of the
PMBus.
READ BYTE
HEX
page 38
99h
MFR_ID
Sets a user defined identification. R/W BLOCK
ASC
<null>
page 38
9Ah
MFR_MODEL
Sets a user defined model.
R/W BLOCK
ASC
<null>
page 38
9Bh
MFR_REVISION
Sets a user defined revision.
R/W BLOCK
ASC
<null>
page 39
9Ch
MFR_LOCATION
Sets a user defined location
identifier.
R/W BLOCK
ASC
<null>
page 39
9Dh
MFR_DATE
Sets a user defined data.
R/W BLOCK
ASC
<null>
page 39
9Eh
MFR_SERIAL
Sets a user defined serialized
identifier.
R/W BLOCK
ASC
<null>
page 39
B0h
USER_DATA_00
Sets a user defined data.
R/W BLOCK
ASC
<null>
page 39
BCh
AUTO_COMP_CONFIG
Configures the Auto
Compensation features.
R/W BYTE
CUS
BDh
AUTO_COMP_CONTROL
Causes the Auto Comp algorithm
to initiate.
SEND BYTE
BIT
BFh
DEADTIME_MAX
Sets the maximum deadtime
values.
R/W WORD
CUS
3838h
H-L = 56ns
L-H = 56ns
page 40
D0h
MFR_CONFIG
Configures several manufacturer
level features.
R/W WORD
BIT
6A11h
Refer to
description
page 41
D1h
USER_CONFIG
Configures several user level
features.
R/W WORD
BIT
2011h
Refer to
description
page 41
D2h
ISHARE_CONFIG
Configures the device for current
sharing mode.
R/W WORD
BIT
0000h
Current share
disabled
page 42
D3h
DDC_CONFIG
Configures the DDC bus.
R/W WORD
BIT
Set based on
PMBus Address
page 42
D4h
POWER_GOOD_DELAY
Sets the delay PG threshold and
asserting the PG pin.
R/W WORD
L11
1ms
page 43
D5h
PID_TAPS
Configures the control loop
compensator coefficients.
R/W BLOCK
CUS
Calculated by
Autocomp
page 43
69h
Autocomp Enabled page 40
Gain = 70%
page 40
BA00h
D6h
INDUCTOR
Sets the inductor value
R/W WORD
L11
D7h
NLR_CONFIG
Configures the non-linear
response (NLR) control.
R/W WORD
BIT
D8h
OVUV_CONFIG
Configures output voltage OV/UV
fault detection
R/W BYTE
BIT
00h
Fastest Response
No Crowbar
page 44
DCh
TEMPCO_CONFIG
Sets tempco settings
R/W BYTE
CUS
2Ch
4400 ppm/°C
page 45
DDh
DEADTIME
Sets default dead time settings
R/W WORD
CUS
1018h
H-L = 16ns
L-H = 24ns
page 45
DEh
DEADTIME_CONFIG
Configures the adaptive dead
time optimization mode
R/W WORD
CUS
8686h
Adaptive dead
time Disabled
page 45
E0h
SEQUENCE
DDC rail sequencing
configuration
R/W WORD
BIT
0000h
Prequel and
Sequel Disabled
page 46
E1h
TRACK_CONFIG
Configures voltage tracking
modes
R/W BYTE
BIT
00h
Tracking
Disabled
page 46
E2h
DDC_GROUP
Configures group ID, fault
R/W BLOCK
spreading, OPERATION and VOUT
BIT
E4h
DEVICE_ID
Returns the device identifier
string
ASC
Submit Document Feedback
22
READ BLOCK
B0E1h
0.22µH
page 44
00000000h Refer description
section
00000000h Ignore Fault
Spread
Reads Device
Version
page 44
page 47
page 47
FN7914.4
December 16, 2014
ZL9117M
PMBus Command Summary (Continued)
COMMAND
CODE
COMMAND NAME
DESCRIPTION
TYPE
DATA
FORMAT
DEFAULT
VALUE
DEFAULT
SETTING
PAGE
E5h
MFR_IOUT_OC_FAULT_RESPONSE Configures the IOUT overcurrent
fault response.
R/W BYTE
BIT
80h
Disable and
No Retry
page 47
E6h
MFR_IOUT_UC_FAULT_RESPONSE Configures the IOUT undercurrent
fault response.
R/W BYTE
BIT
80h
Disable and
No Retry
page 48
E7h
IOUT_AVG_OC_FAULT_LIMIT
Sets the IOUT average overcurrent R/W WORD
fault threshold.
L11
DB20h
25A
page 48
E8h
IOUT_AVG_UC_FAULT_LIMIT
Sets the IOUT average
undercurrent fault threshold.
R/W WORD
L11
DCE0h
-25A
page 48
E9h
MISC_CONFIG
Sets options pertaining to
advanced features.
R/W WORD
BIT
0800h
Broadcast
Disabled
page 49
EAh
SNAPSHOT
32-byte read-back of parametric
and status values
READ BLOCK
BIT
N/A
page 49
EBh
BLANK_PARAMS
Indicates recently saved
parameter values
READ BLOCK
BIT
FF...FFh
F0h
PHASE_CONTROL
Controls Phase adding/dropping
for current sharing configuration.
R/W BYTE
BIT
00h
F3h
SNAPSHOT_CONTROL
Controls how SNAPSHOT values
are handled.
R/W BYTE
BIT
F4h
RESTORE_FACTORY
Restores device to the hard-coded
default values
SEND BYTE
F5h
MFR_VMON_OV_FAULT_LIMIT
Sets the VDRV overvoltage fault
threshold
R/W WORD
L11
CB80
7V
page 50
F6h
MFR_VMON_UV_FAULT_LIMIT
Sets the VDRV undervoltage fault
threshold
R/W WORD
L11
CA40h
4.5V
page 51
F7h
MFR_READ_VMON
Reads the VDRV voltage
READ WORD
L11
F8h
VMON_OV_FAULT_RESPONSE
Configures the VDRV overvoltage
fault response
R/W BYTE
BIT
80h
Disable and
No Retry
page 51
F9h
VMON_UV_FAULT_RESPONSE
Configures the VDRV
undervoltage fault response
R/W BYTE
BIT
80h
Disable and
No Retry
page 51
FAh
SECURITY_LEVEL
Reports the security level
READ BYTE
HEX
1
Public Security
Level
page 52
FBh
PRIVATE_PASSWORD
Sets the private password string
R/W BLOCK
ASC
000...00h
FCh
PUBLIC_PASSWORD
Sets the public password string
R/W BLOCK
ASC
00...00h
FDh
UNPROTECT
Identifies which commands are
protected
R/W BLOCK
BIT
FF...FFh
Submit Document Feedback
23
page 50
All Phases active
page 50
page 50
page 50
page 51
page 54
page 54
N/A
page 54
FN7914.4
December 16, 2014
ZL9117M
PMBus™ Data Formats
Linear-11 (L11)
L11 data format uses 5-bit two’s compliment exponent (N) and 11-bit two’s compliment mantissa (Y) to represent real world decimal
value (X).
Data Byte High
Data Byte Low
7 6 5 4 3 2 1 0
7 6 5 4 3 2 1 0
Exponent (N)
Mantissa (Y)
Relation between real world decimal value (X), N and Y is: X = Y·2N
Linear-16 Unsigned (L16u)
L16u data format uses a fixed exponent (hard-coded to N = -13h) and a 16-bit unsigned integer mantissa (Y) to represent real world
decimal value (X). Relation between real world decimal value (X), N and Y is: X = Y·2-13
Linear-16 Signed (L16s)
L16s data format uses a fixed exponent (hard-coded to N = -13h) and a 16-bit two’s compliment mantissa (Y) to represent real world
decimal value (X).
Relation between real world decimal value (X), N and Y is: X = Y·2-13
Bit Field (BIT)
Break down of Bit Field is provided in the following PMBus™ Command Description Section
Custom (CUS)
Break down of Custom data format is provided in the following PMBus™ Command Description section. A combination of Bit Field and
integer are common type of Custom data format.
ASCII (ASC)
A variable length string of text characters uses ASCII data format.
PMBus Commands Description
OPERATION (01h)
Definition: Sets Enable, Disable and VOUT Margin settings. If multiple ZL9117M modules are configured as a current sharing rail, and at
the mean time are configured to start/shutdown from ENABLE pin (in the ON_OFF_CONFIG), then the margining of the current sharing
rail should follow this procedure: the desired OPERATION command should be sent to all the member modules first, then the same
OPERATION command is sent to the reference module at last.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value:
Units: N/A
SETTINGS
ACTIONS
04h
Immediate off (no sequencing)
44h
Soft off (with sequencing)
84h
On - Nominal
94h
On - Margin low
A4h
On - Margin high
Submit Document Feedback
24
FN7914.4
December 16, 2014
ZL9117M
ON_OFF_CONFIG (02h)
Definition: Configures the interpretation and coordination of the OPERATION command and the ENABLE pin (EN).
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 16h (Device starts/shutdown from ENABLE pin with soft off)
Units: N/A
SETTINGS
ACTIONS
00h
Device starts any time power is present regardless of ENABLE pin or OPERATION command states.
16h
Device starts/shutdowns from ENABLE pin with soft off option
17h
Device starts/shutdowns from ENABLE pin with immediate off option
1Ah
Device starts/shutdowns from OPERATION command
CLEAR_FAULTS (03h)
Definition: Clears all fault bits in all registers. If a fault condition still exists, the bit will reassert immediately. This command will not
restart a device if it has shut down, it will only clear the faults.
Data Length in Bytes: 0
Data Format: N/A
Type: Send Byte
Default Value: N/A
Units: N/A
STORE_DEFAULT_ALL (11h)
Definition: Stores all current PMBus™ values from the operating memory into the non-volatile DEFAULT Store memory. To clear the
DEFAULT store, perform a RESTORE_FACTORY then STORE_DEFAULT_ALL. To add to the DEFAULT store, perform a
RESTORE_DEFAULT_ALL, write commands to be added, then STORE_DEFAULT_ALL. This command should not be used during device
operation, the device will be unresponsive for 20ms while storing values.
Data Length in Bytes: 0
Data Format: N/A
Type: Send Byte
Default Value: N/A
Units: N/A
RESTORE_DEFAULT_ALL (12h)
Definition: Restores PMBus™ settings from the non-volatile DEFAULT Store memory into the operating memory. These settings are
loaded at power up if not superseded by settings in USER store. Security level is changed to level 1 following this command. This
command should not be used during device operation.
Data Length in Bytes: 0
Data Format: N/A
Type: Send Byte
Default Value: N/A
Units: N/A
STORE_USER_ALL (15h)
Definition: Stores all PMBus settings from the operating memory to the non-volatile USER store memory. To clear the USER store,
perform a RESTORE_FACTORY then STORE_USER_ALL. To add to the USER store, perform a RESTORE_USER_ALL, write commands to
be added, then STORE_USER_ALL. This command can be used during device operation, but the device will be unresponsive for 20ms
while storing values.
Data Length in Bytes: 0
Data Format: N/A
Type: Send Byte
Default Value: N/A
Units: N/A
Submit Document Feedback
25
FN7914.4
December 16, 2014
ZL9117M
RESTORE_USER_ALL (16h)
Definition: Restores all PMBus settings from the USER store memory to the operating memory. Command performed at power-up.
Security level is changed to Level 1 following this command. This command can be used during device operation.
Data Length in Bytes: 0
Data Format: N/A
Type: Send Byte
Default Value: N/A
Units: N/A
VOUT_MODE (20h)
Definition: Reports the VOUT mode and provides the exponent used in calculating several VOUT settings. Fixed with linear mode with
default exponent (N) = -13.
Data Length in Bytes: 1
Data Format: BIT
Type: Read only
Default Value: 13h (Linear Mode, N = -13)
Units: N/A
VOUT_COMMAND (21h)
Definition: This command sets or reports the target output voltage. This command cannot set a value higher than either VOUT_MAX or
110% of the pin strap VOUT setting.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W Word
Default Value: Pin strap setting
Units: Volts
Range: 0V to VOUT_MAX
VOUT_TRIM (22h)
Definition: Sets a trim value on VOUT
Data Length in Bytes: 2
Data Format: L16s
Type: R/W Word
Default Value: 0000h
Units: Volts
Range: -4V to 4V
VOUT_CAL_OFFSET (23h)
Definition: The VOUT_CAL_OFFSET command is used to apply a fixed offset voltage to the output voltage command value. This
command is typically used by the user to calibrate a device in the application circuit.
Data Length in Bytes: 2
Data Format: L16s
Type: R/W Word
Default Value: 0000h
Units: Volts
Range: -4V to 4V
VOUT_MAX (24h)
Definition: The VOUT_ MAX command sets an upper limit on the output voltage the unit can command regardless of any other
commands or combinations. The intent of this command is to provide a safeguard against a user accidentally setting the output
voltage to a possibly destructive level rather than to be the primary output overprotection.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W Word
Default Value: 1.10 x VOUT_COMMAND pin strap setting
Units: Volts
Range: 0V to 4V
Submit Document Feedback
26
FN7914.4
December 16, 2014
ZL9117M
VOUT_MARGIN_HIGH (25h)
Definition: Sets the value of the VOUT during a margin high. This VOUT_MARGIN_HIGH command loads the unit with the voltage to
which the output is to be changed when the OPERATION command is set to “Margin High”.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W Word
Default value: 1.05 x VOUT_COMMAND pin strap setting
Units: Volts
Range: 0V to VOUT_MAX
VOUT_MARGIN_LOW (26h)
Definition: Sets the value of the VOUT during a margin low. This VOUT_MARGIN_LOW command loads the unit with the voltage to which
the output is to be changed when the OPERATION command is set to “Margin Low”.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W Word
Default value: 0.95 x VOUT_COMMAND pin strap setting
Units: Volts
Range: 0V to VOUT_MAX
VOUT_TRANSITION_RATE (27h)
Definition: This command sets the rate at which the output should change voltage when the device receives an OPERATION command
(Margin High, Margin Low) that causes the output voltage to change. The maximum possible positive value of the two data bytes
indicates that the device should make the transition as quickly as possible.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default value: BA00h (1.0 V/ms)
Units: V/ms
Range: 0.1 to 4V/ms
VOUT_DROOP (28h)
Definition: The VOUT_DROOP sets the effective load line (V/I slope) for the rail in which the device is used. It is the rate, in mV/A, at
which the output voltage decreases (or increases) with increasing (or decreasing) output current for use with Adaptive Voltage
Positioning requirements and passive current sharing schemes.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default value: 0000h (0mV/A)
Units: mV/A
Range: 0 to 40 mV/A
MAX_DUTY (32h)
Definition: Sets the maximum allowable duty cycle
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: EABDh (91.375%)
Units: %
Submit Document Feedback
27
FN7914.4
December 16, 2014
ZL9117M
FREQUENCY_SWITCH (33h)
Definition: Sets the switching frequency of the device. Initial default value is defined by a pin strap and this value can be overridden by
writing this command via PMBus. If an external SYNC is utilized, this value should be set as close as possible to the external clock value.
The output must be disabled when writing this command.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: Pin strap setting
Units: kHz
Range: 400kHz to 1000kHz
INTERLEAVE (37h)
Definition: Configures the phase offset of a device that is sharing a common SYNC clock with other devices. A value of 0 for the Number
in Group field is interpreted as 16, to allow for phase spreading groups of up to 16 devices. For current sharing rails, INTERLEAVE is used
to set the initial phase of the rail. The current share devices then automatically distribute their phase relative to the INTERLEAVE.
setting.
Data Length in Bytes: 2
Data Format: BIT
Type: R/W Word
Default Value: Set based on pin-strap PMBus address
Units: N/A
BITS
PURPOSE
VALUE
15:2
Reserved
0
DESCRIPTION
Reserved
11:8
Group Number
0 to 15
Sets a number to a group of interleaved rails
7:4
Number in Group
0 to 15
Sets the number of rails in the group A value of 0 is interpreted as 16
3:0
Position in Group
0 to 15
Sets position of the device's rail within the group
IOUT_CAL_GAIN (38h)
Definition: Sets the effective impedance across the current sense circuit for use in calculating output current at +25°C.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: BA2Ah (1.083mΩ)
Units: mΩ
IOUT_CAL_OFFSET (39h)
Definition: Used to null out any offsets in the output current sensing circuit, and to compensate for delayed measurements of current
ramp due to Isense blanking time.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: BE00h (-1A)
Units: A
VOUT_OV_FAULT_LIMIT (40h)
Definition: Sets the VOUT overvoltage fault threshold.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W Word
Default Value: 1.15 x VOUT_COMMAND pin strap setting
Units: V
Range: 0V to VOUT_MAX
Submit Document Feedback
28
FN7914.4
December 16, 2014
ZL9117M
VOUT_OV_FAULT_RESPONSE (41h)
Definition: Configures the VOUT overvoltage fault response. Note that the device cannot be set to ignore this fault mode. The retry time
is the time between restart attempts.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable and no retry)
Units: N/A
BIT
7:6
5:3
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110 The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
Retry Setting
111
2:0
DESCRIPTION
00
Retry and Delay Time
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
000-111 This time count is used for both the amount of time between retry attempts and for the amount
of time a rail is to delay its response after a fault is detected. The retry time and delay time units
are defined by the type of fault within each device.
VOUT_UV_FAULT_LIMIT (44h)
Definition: Sets the VOUT undervoltage fault threshold. This fault is masked during ramp or when the device is disabled.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W Word
Default Value: 0.85 x VOUT_COMMAND pin strap setting
Units: V
Range: 0V to VOUT_MAX
VOUT_UV_FAULT_RESPONSE (45h)
Definition: Configures the VOUT undervoltage fault response.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable, no retry)
Units: N/A
BIT
7:6
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
Submit Document Feedback
29
DESCRIPTION
00
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
FN7914.4
December 16, 2014
ZL9117M
BIT
FIELD NAME
VALUE
000
5:3
2:0
Retry Setting
Retry and Delay Time
DESCRIPTION
No Retry. The output remains disabled until the device is restarted.
001-110
The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
111
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
This time count is used for both the amount of time between retry attempts and for the
000-111 amount of time a rail is to delay its response after a fault is detected. The retry time and delay
time units are defined by the type of fault within each device.
IOUT_OC_FAULT_LIMIT (46h)
Definition: Sets the inductor peak overcurrent fault threshold. This limit is applied to current measurement samples taken after the
current sense blanking time has expired. A fault occurs after this limit is exceeded for the number of consecutive samples as defined in
MFR_CONFIG.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: E250h (37A)
Units: A
Range: -100 to 100A
IOUT_UC_FAULT_LIMIT (4Bh)
Definition: Sets the inductor valley undercurrent fault threshold. This limit is applied to current measurement samples taken after the
current sense blanking time has expired. A fault occurs after this limit is exceeded for the number of consecutive samples as defined in
MFR_CONFIG.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: E5B0h (-37A)
Units: A
Range: -100 to 100A
OT_FAULT_LIMIT (4Fh)
Definition: Sets the temperature at which the device should indicate an over-temperature fault. Note that the temperature must drop
below OT_WARN_LIMIT to clear this fault.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: EBE8h (+125°C)
Units: Celsius
Range: 0 to +175°C
OT_FAULT_RESPONSE (50h)
Definition: Instructs the device on what action to take in response to an over-temperature fault. The delay time is the time between
restart attempts.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable and no retry)
Units: N/A
Submit Document Feedback
30
FN7914.4
December 16, 2014
ZL9117M
BIT
7:6
5:3
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
00
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110 The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
Retry Setting
111
2:0
DESCRIPTION
Retry and Delay Time
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
000-111 This time count is used for both the amount of time between retry attempts and for the amount
of time a rail is to delay its response after a fault is detected. The retry time and delay time units
are defined by the type of fault within each device.
OT_WARN_LIMIT (51h)
Definition: Sets the temperature at which the device should indicate an over-temperature warning alarm. In response to the
OT_WARN_LIMIT being exceeded, the device: Sets the TEMPERATURE bit in STATUS_WORD, Sets the OT_WARNING bit in
STATUS_TEMPERATURE, and notifies the host.
Data Length in Bytes: 2
Data Format: L11.
Type: R/W Word
Default Value: EB70h (+110°C)
Units: Celsius
Range: 0 to +175°C
UT_WARN_LIMIT (52h)
Definition: Set the temperature at which the device should indicate an under-temperature warning alarm. In response to the
UT_WARN_LIMIT being exceeded, the device sets the TEMPERATURE bit in STATUS_WORD, sets the UT_WARNING bit in
STATUS_TEMPERATURE, and notifies the host.
Data Length in Bytes: 2
Data Format: L11.
Type: R/W Word
Default Value: E4E0h (-50°C)
Units: Celsius
Range: -55 to +25°C
UT_FAULT_LIMIT (53h)
Definition: Sets the temperature at which the device should indicate an under-temperature fault. Note that the temperature must rise
above UT_WARN_LIMIT to clear this fault.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: E490h (-55°C)
Units: Celsius
Range: -55 to +25°C
UT_FAULT_RESPONSE (54h)
Definition: Instructs the device on what action to take in response to an under-temperature fault. The delay time is the time between
restart attempts.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable, no retry)
Units: N/A
Submit Document Feedback
31
FN7914.4
December 16, 2014
ZL9117M
BIT
7:6
5:3
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
00
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110 The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
Retry Setting
111
2:0
DESCRIPTION
Retry and Delay Time
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
000-111 This time count is used for both the amount of time between retry attempts and for the amount
of time a rail is to delay its response after a fault is detected. The retry time and delay time units
are defined by the type of fault within each device.
VIN_OV_FAULT_LIMIT (55h)
Definition: Sets the VIN overvoltage fault threshold.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: D3A0h (14.5V)
Units: V
Range: 0 to 16V
VIN_OV_FAULT_RESPONSE (56h)
Definition: Configures the VIN overvoltage fault response. The delay time is the time between restart attempts.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable and no retry)
Units:
BIT
7:6
5:3
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
00
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110 The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
Retry Setting
111
2:0
Retry and Delay Time
Submit Document Feedback
DESCRIPTION
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
000-111 This time count is used for both the amount of time between retry attempts and for the amount
of time a rail is to delay its response after a fault is detected. The retry time and delay time units
are defined by the type of fault within each device.
32
FN7914.4
December 16, 2014
ZL9117M
VIN_OV_WARN_LIMIT (57h)
Definition: Sets the VIN overvoltage warning threshold. In response to the VIN_OV_WARN_LIMIT being exceeded, the device sets the
NONE OF THE ABOVE and INPUT bits in STATUS_WORD, sets the VIN_OV_WARNING bit in STATUS_INPUT, and notifies the host.
Data Length in Bytes: 2
Data Format: L11.
Type: R/W Word
Default Value: D34Dh (13.2V)
Units: V
Range: 0 to 19V
VIN_UV_WARN_LIMIT (58h)
Definition: Sets the VIN undervoltage warning threshold. If a VIN_UV_FAULT occurs, the input voltage must rise above
VIN_UV_WARN_LIMIT to clear the fault, which provides hysteresis to the fault threshold. In response to the UV_WARN_LIMIT being
exceeded, the device sets the NONE OF THE ABOVE and INPUT bits in STATUS_WORD, sets the VIN_UV_WARNING bit in STATUS_INPUT,
and notifies the host.
Data Length in Bytes: 2
Data Format: L11.
Type: R/W Word
Default Value: CA30h (4.38V)
Units: V
Range: 0 to 19V
VIN_UV_FAULT_LIMIT (59h)
Definition: Sets the VIN undervoltage fault threshold.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: CA00h (4V)
Units: V
Range: 0 to 12V
VIN_UV_FAULT_RESPONSE (5Ah)
Definition: Configures the VIN undervoltage fault response. The delay time is the time between restart attempts.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable and no retry)
Units:
BIT
7:6
5:3
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110 The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
Retry Setting
111
2:0
Retry and Delay Time
Submit Document Feedback
DESCRIPTION
00
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
000-111 This time count is used for both the amount of time between retry attempts and for the amount
of time a rail is to delay its response after a fault is detected. The retry time and delay time units
are defined by the type of fault within each device.
33
FN7914.4
December 16, 2014
ZL9117M
POWER_GOOD_ON (5Eh)
Definition: Sets the voltage threshold for Power-Good indication. Power-Good asserts when the output voltage exceeds
POWER_GOOD_ON and de-asserts when the output voltage is less than VOUT_UV_FAULT_LIMIT.
Data Length in Bytes: 2
Data Format: L16u
Type: R/W Word
Default Value: 0.9 x VOUT_COMMAND pin strap setting
Units: V
TON_DELAY (60h)
Definition: Sets the delay time from when the device is enabled to the start of VOUT rise.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: CA80h (5ms)
Units: ms
Range: 0 to 500s
TON_RISE (61h)
Definition: Sets the rise time of VOUT after ENABLE and TON_DELAY.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: D280h (10ms)
Units: ms
Range: 0 to 200ms
TOFF_DELAY (64h)
Definition: Sets the delay time from DISABLE to start of VOUT fall.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: CA80h (5ms)
Units: ms
Range: 0 to 500s
TOFF_FALL (65h)
Definition: Sets the fall time for VOUT after DISABLE and TOFF_DELAY.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: D280h (10ms)
Units: ms
Range: 0 to 200ms
STATUS_BYTE (78h)
Definition: The STATUS_BYTE command returns one byte of information with a summary of the most critical faults.
Data Length in Bytes: 1
Data Format: BIT
Type: Read Only
Default Value: 00h
Units: N/A
BIT NUMBER
STATUS BIT NAME
7
BUSY
6
OFF
5
VOUT_OV_FAULT
An output overvoltage fault has occurred.
4
IOUT_OC_FAULT
An output overcurrent fault has occurred.
Submit Document Feedback
34
MEANING
A fault was declared because the device was busy and unable to respond.
This bit is asserted if the unit is not providing power to the output, regardless of
the reason, including simply not being enabled.
FN7914.4
December 16, 2014
ZL9117M
BIT NUMBER
STATUS BIT NAME
MEANING
3
VIN_UV_FAULT
An input undervoltage fault has occurred.
2
TEMPERATURE
A temperature fault or warning has occurred.
1
CML
0
NONE OF THE ABOVE
A communications, memory or logic fault has occurred.
A fault or warning not listed in bits 7:1 has occurred.
STATUS_WORD (79h)
Definition: The STATUS_WORD command returns two bytes of information with a summary of the unit's fault condition. Based on the
information in these bytes, the host can get more information by reading the appropriate status registers. The low byte of the
STATUS_WORD is the same register as the STATUS_BYTE (78h) command.
Data Length in Bytes: 2
Data Format: BIT
Type: Read Only
Default Value: 0000h
Units: N/A
BIT NUMBER
STATUS BIT NAME
MEANING
15
VOUT
14
IOUT/POUT
13
INPUT
12
MFG_SPECIFIC
11
POWER_GOOD#
10
FANS
9
OTHER
8
UNKNOWN
7
BUSY
6
OFF
5
VOUT_OV_FAULT
An output overvoltage fault has occurred.
4
IOUT_OC_FAULT
An output overcurrent fault has occurred.
3
VIN_UV_FAULT
An input undervoltage fault has occurred.
2
TEMPERATURE
A temperature fault or warning has occurred.
1
CML
0
NONE OF THE ABOVE
An output voltage fault or warning has occurred.
An output current or output power fault or warning has occurred.
An input voltage, input current, or input power fault or warning has occurred.
A manufacturer specific fault or warning has occurred.
The POWER_GOOD signal, if present, is negated. (1)
A fan or airflow fault or warning has occurred.
A bit in STATUS_OTHER is set.
A fault type not given in bits 15:1 of the STATUS_WORD has been detected.
A fault was declared because the device was busy and unable to respond.
This bit is asserted if the unit is not providing power to the output, regardless of
the reason, including simply not being enabled.
A communications, memory or logic fault has occurred.
A fault or warning not listed in bits 7:1 has occurred.
STATUS_VOUT (7Ah)
Definition: The STATUS_VOUT command returns one data byte with the status of the output voltage.
Data Length in Bytes: 1
Data Format: BIT
Type: Read Only
Default Value: 00h
Units: N/A
BIT NUMBER
STATUS BIT NAME
7
VOUT_OV_FAULT
6
VOUT_OV_WARNING
Indicates an output overvoltage warning.
5
VOUT_UV_WARNING
Indicates an output undervoltage warning.
4
VOUT_UV_FAULT
3:0
N/A
Submit Document Feedback
35
MEANING
Indicates an output overvoltage fault.
Indicates an output undervoltage fault.
These bits are not used.
FN7914.4
December 16, 2014
ZL9117M
STATUS_IOUT (7Bh)
Definition: The STATUS_IOUT command returns one data byte with the status of the output current.
Data Length in Bytes: 1
Data Format: BIT
Type: Read Only
Default Value: 00h
Units: N/A
BIT NUMBER
STATUS BIT NAME
7
IOUT_OC_FAULT
6
IOUT_OC_LV_FAULT
5
IOUT_OC_WARNING (not used)
4
IOUT_UC_FAULT
3:0
N/A
MEANING
An output overcurrent fault has occurred.
An output overcurrent and low voltage fault has occurred.
Reserved
An output undercurrent fault has occurred.
These bits are not used.
STATUS_INPUT (7Ch)
Definition: The STATUS_INPUT command returns input voltage and input current status information.
Data Length in Bytes: 1
Data Format: BIT
Type: Read Only
Default Value: 00h
Units: N/A
BIT NUMBER
STATUS BIT NAME
MEANING
7
VIN_OV_FAULT
6
VIN_OV_WARNING
An input overvoltage warning has occurred.
5
VIN_UV_WARNING
An input undervoltage warning has occurred.
4
VIN_UV_FAULT
3:0
N/A
An input overvoltage fault has occurred.
An input undervoltage fault has occurred.
These bits are not used.
STATUS_TEMPERATURE (7Dh)
Definition: The STATUS_TEMP command returns one byte of information with a summary of any temperature related faults or warnings.
Data Length in Bytes: 1
Data Format: BIT
Type: Read Only
Default Value: 00h
Units: N/A
BIT NUMBER
STATUS BIT NAME
7
OT_FAULT
6
OT_WARNING
An over-temperature warning has occurred.
5
UT_WARNING
An under-temperature warning has occurred.
4
UT_FAULT
3:0
N/A
Submit Document Feedback
36
MEANING
An over-temperature fault has occurred.
An under-temperature fault has occurred.
These bits are not used.
FN7914.4
December 16, 2014
ZL9117M
STATUS_CML (7Eh)
Definition: The STATUS_WORD command returns one byte of information with a summary of any Communications, Logic and/or
Memory errors.
Data Length in Bytes: 1
Data Format: BIT
Type: Read Only
Default Value: 00h
Units: N/A
BIT NUMBER
MEANING
7
Invalid or unsupported PMBus™ Command was received.
6
The PMBus™ command was sent with Invalid or Unsupported data.
5
A packet error was detected in the PMBus™ command.
4:2
Not Used
1
A PMBus™ command tried to write to a read-only or protected command, or a communication fault other than the ones listed in
this table has occurred.
0
Not Used
STATUS_MFR_SPECIFIC (80h)
Definition: The STATUS_MFR_SPECIFIC command returns one byte of information providing the status of the device's voltage
monitoring and clock synchronization faults. VDRV OV/UV warnings are set at +/-10% of the VMON_OV_FAULT/VMON_UV_FAULT
commands.
Data Length in Bytes: 1
Data Format: BIT
Type: Read Only
Default value: 00h
Units: N/A
BIT NUMBER
7:6
5
FIELD NAME
MEANING
Reserved
VDRV UV Warning
The voltage on the VMON pin has dropped 10% below the level set by
MFR_VMON_UV_FAULT_LIMIT.
VDRV OV Warning
The voltage on the VMON pin has risen 10% above the level set by
MFR_VMON_OV_FAULT_LIMIT.
3
External Switching Period Fault
Loss of external clock synchronization has occurred.
2
Reserved
4
1
0
VDRV UV Fault
VDRV OV Fault
The voltage on the VMON pin has dropped below the level set by
MFR_VMON_UV_FAULT_LIMIT.
The voltage on the VMON pin has risen above the level set by
MFR_VMON_OV_FAULT_LIMIT.
READ_VIN (88h)
Definition: Returns the input voltage reading.
Data Length in Bytes: 2
Data Format: L11
Type: Read Only
Units: V
READ_VOUT (8Bh)
Definition: Returns the output voltage reading.
Data Length in Bytes: 2
Data Format: L16u
Type: Read Only
Units: V
Submit Document Feedback
37
FN7914.4
December 16, 2014
ZL9117M
READ_IOUT (8Ch)
Definition: Returns the output current reading.
Data Length in Bytes: 2
Data Format: L11
Type: Read Only
Default Value: N/A
Units: A
READ_TEMPERATURE_1 (8Dh)
Definition: Returns the controller junction temperature reading from internal temperature sensor.
Data Length in Bytes: 2
Data Format: L11
Type: Read Only
Units: °C
READ_DUTY_CYCLE (94h)
Definition: Reports the actual duty cycle of the converter during the enable state.
Data Length in Bytes: 2
Data Format: L11
Type: Read Only
Units:%
READ_FREQUENCY (95h)
Definition: Reports the actual switching frequency of the converter during the enable state.
Data Length in Bytes: 2
Data Format: L11
Type: Read Only
Units: kHz
PMBUS_REVISION (98h)
Definition: Returns the revision of the PMBus implemented in the device.
Data Length in Bytes: 1
Data Format: HEX
Type: Read Only
Units: N/A
MFR_ID (99h)
Definition: MFR_ID sets user defined identification. The sum total of characters in MFR_ID, MFR_MODEL, MFR_REVISION,
MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 characters. This
limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write this
command then perform a STORE/RESTORE.
Data Length in Bytes: user defined
Data Format: ASC
Type: Block R/W
Default Value: null
Units: N/A
MFR_MODEL (9Ah)
Definition: MFR_MODEL sets a user defined model. The sum total of characters in MFR_ID, MFR_MODEL, MFR_REVISION,
MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 characters. This
limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write this
command then perform a STORE/RESTORE.
Data Length in Bytes: user defined
Data Format: ASC
Type: Block R/W
Default Value: null
Units: N/A
Submit Document Feedback
38
FN7914.4
December 16, 2014
ZL9117M
MFR_REVISION (9Bh)
Definition: MFR_REVISION sets a user defined revision. The sum total of characters in MFR_ID, MFR_MODEL, MFR_REVISION,
MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 characters. This
limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write this
command then perform a STORE/RESTORE.
Data Length in Bytes: user defined
Data Format: ASC
Type: Block R/W
Default Value: null
Units: N/A
MFR_LOCATION (9Ch)
Definition: MFR_LOCATION sets a user defined location identifier. The sum total of characters in MFR_ID, MFR_MODEL, MFR_REVISION,
MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 characters. This
limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write this
command then perform a STORE/RESTORE.
Data Length in Bytes: user defined
Data Format: ASC
Type: Block R/W
Default Value: null
Units: N/A
MFR_DATE (9Dh)
Definition: MFR_DATE sets a user defined date. The sum total of characters in MFR_ID, MFR_MODEL, MFR_REVISION, MFR_LOCATION,
MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 characters. This limitation includes
multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write this command then
perform a STORE/RESTORE.
Data Length in Bytes: user defined
Data Format: ASC
Type: Block R/W
Default Value: null
Units: N/A
MFR_SERIAL (9Eh)
Definition: MFR_SERIAL sets a user defined serialized identifier. The sum total of characters in MFR_ID, MFR_MODEL, MFR_REVISION,
MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 characters. This
limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write this
command then perform a STORE/RESTORE.
Data Length in Bytes: user defined
Data Format: ASC
Type: Block R/W
Default Value: null
Units: N/A
USER_DATA_00 (B0h)
Definition: USER_DATA_00 sets a user defined data. The sum total of characters in MFR_ID, MFR_MODEL, MFR_REVISION,
MFR_LOCATION, MFR_DATE, MFR_SERIAL and USER_DATA_00 plus one byte per command cannot exceed 128 characters. This
limitation includes multiple writes of this command before a STORE command. To clear multiple writes, perform a RESTORE, write this
command then perform a STORE/RESTORE.
Data Length in Bytes: user defined
Data Format: ASCII
Type: Block R/W
Default Value: null
Units: N/A
Submit Document Feedback
39
FN7914.4
December 16, 2014
ZL9117M
AUTO_COMP_CONFIG (BCh)
Definition: Controls configuration of Auto Compensation features.
Data Length in Bytes: 1
Data Format: CUS
Type: R/W Byte
Default Value: 69h (Auto Comp Once, Do not store results, PG assertion after Auto Comp, and Gain = 70%)
Units: N/A
BITS
PURPOSE
7:4
VALUE
DESCRIPTION
G
Scale the Gain of the Auto-Compensation results by a factor of
(G+1)*10%, where 0 ≤ G ≤ 9. G = 0 yields lowest jitter; G = 9 yields
tightest transient response.
0
Use PG_DELAY
1
Assert PG after Auto Comp completes
0
Do not store Auto Comp results
1
Store Auto Comp results for use on future ramps
0
Off (Disabled). Compensation stored in PID_TAPS will be used.
1
Once (results are storable)
2
Repeat every ~1 second (only the first results are storable)
3
Repeat every ~1 minute (only the first results are storable)
Auto Comp Gain Percentage
3
Power Good Assertion
2
Auto Comp Store
1:0
Auto Comp Mode
AUTO_COMP_CONTROL (BDh)
Definition: Causes the Auto Comp algorithm to initiate when the Auto Comp feature is enabled in AUTO_COMP_CONFIG.
Data Length in Bytes: 0
Data Format: BIT
Type: Send Byte
Default Value:
Units: N/A
DEADTIME_MAX (BFh)
Definition: Sets the maximum dead time value for the PWMH and PWML outputs. This limit applies during frozen or adaptive dead time
algorithm modes (see DEADTIME_CONFIG).
Data Length in Bytes: 2
Data Format: CUS
Type: R/W Word
Default Value: 3838h (56ns/56ns)
Units: ns
Range: 0 to 60ns
BITS
15
14:8
7
6:0
PURPOSE
VALUE
DESCRIPTION
Not Used
0
Not Used
Sets the maximum H-to-L dead time
H
Limits the maximum allowed H-to-L dead time when using the adaptive
dead time algorithm. dead time = Hns (signed)
Not Used
0
Not Used
Sets the maximum L-to-H dead time
L
Limits the maximum allowed L-to-H dead time when using the adaptive
dead time algorithm. dead time = Lns (signed)
Submit Document Feedback
40
FN7914.4
December 16, 2014
ZL9117M
MFR_CONFIG (D0h)
Definition: Configures several manufacturer-level features.
Data Length in Bytes: 2
Data Format: BIT
Type: R/W Word
Default Value: 6A11h (416ns, 5 Count, Down Slope, NLR wait for PG, PG Open Drain, Sync Push-Pull)
Units: N/A
BITS
15:11
10:8
7:6
5:4
PURPOSE
VALUE
DESCRIPTION
Current Sense Blanking Delay
D
Sets the delay, D, in 32ns steps
Current Sense Fault Count
C
Sets the number of consecutive OC or UC violations required for a fault to 2C+1.
Reserved
Current Sense Control
3
NLR During Ramp
2
Alternate Ramp Control
1
PG Pin Output Control
0
SYNC Pin Output Control
00
Current sense uses GND-referenced, down-slope sense
01
Current sense uses VOUT-referenced, down-slope sensing
10
Current sense uses VOUT-referenced, up-slope sensing
11
Reserved
0
Wait for PG
1
Always on
0
Alternate Ramp Disabled
1
Alternate Ramp Enabled
0
PG is open-drain
1
PG is push-pull
0
SYNC is open-drain
1
SYNC is push-pull
USER_CONFIG (D1h)
Definition: Configures several user-level features.
Data Length in Bytes: 2
Data Format: BIT
Type: R/W Word
Default Value: 2011h (Min Duty Enabled = 1* Tsw/256, PID feed forward correct for VDD, Ignore Fault spread, Clock SYNC pin strap
mode, use internal clock, Lowside MOSFET off when disabled, Monitor mode enabled)
Units: N/A
BITS
15:14
13
PURPOSE
VALUE
DESCRIPTION
Minimum Duty Cycle
N
Sets the minimum duty cycle ((N+1)/(2^8)) during a ramp when “Minimum Duty Cycle”
(Bit 13) is enabled. For example, if Minimum Duty Cycle input N is set to 3, the minimum duty
cycle is (3+1)/(28) = (1/64).
Minimum Duty Cycle Control
0
Minimum Duty Cycle is Disabled
1
Minimum Duty Cycle is Enabled
12
Reserved
0
11
SYNC Time-out Enable
0
SYNC output remains on after device is disabled
1
SYNC turns off 500ms after device is disabled
10
Reserved
-
Reserved
9
PID Feed-Forward Control
0
PID Coefficients are corrected for VDD variation
1
PID Coefficients are not corrected for VDD variations
Submit Document Feedback
41
FN7914.4
December 16, 2014
ZL9117M
BITS
PURPOSE
VALUE
DESCRIPTION
0
If sequencing is disabled, this device will ignore faults from other devices. If sequencing is
enabled, the devices will sequence down from the failed device outward.
1
Faults received from any device selected by the DDC_GROUP command will cause this device
to shut down immediately.
0
* SMBus transmit is always disabled in DDC devices
0
Auto-configure using the SYNC pin and FREQUENCY_SWITCH parameter
1
Switch using the SYNC input
0
Configure the SYNC pin as an input-only
1
Drive the switch clock out of SYNC when using the internal oscillator
8
Fault Spreading Mode
7
SMBus Transmit Clk Rate
6
SYNC Utilization Control
5
SYNC Output Control
4
SMBus Transmit Inhibit
0
* SMBus transmit is always disabled in DDC devices
3
SMBus Timeout Inhibit
0
* SMBus transmit is always disabled in DDC devices
2
OFF Low-side Control
0
The low-side drive is off when device is disabled
1
The low-side drive is on when device is disabled
1:0
Standby Mode
00
Enter low-power mode when device is disabled (no READ_xxxx data available)
01
Monitor for faults when device is disabled (READ_xxxx data available)
10
Reserved
11
Monitor for faults using pulsed mode. (READ_xxxx data available upon read command)
ISHARE_CONFIG (D2h)
Definition: Configures the device for current sharing communication over the DDC bus.
Data Length in Bytes: 2
Data Format: BIT
Type: R/W Word
Default Value: 0000h (Device configured to operate in signal phase mode)
Units:
BITS
15:8
PURPOSE
IShare
DDC ID
VALUE
DESCRIPTION
0 to 31
(0x00 to 0x1F)
Sets the current share rail’s DDC ID for each device within a current share rail.
Set to the same DDC ID as in DDC_CONFIG.
This DDC ID is used for sequencing and fault spreading when used in a current share rail.
7:5
Number of Members
0 to 7
Number of devices in current share rail -1.
Example: 3 device current share rail, use 3 – 1 = 2
4:2
Member Position
0 to 7
Position of device within current share rail
1
0
Reserved
I-Share Control
0
Reserved
1
Device is a member of a current share rail
0
Device is not a member of a current share rail
DDC_CONFIG (D3h)
Definition: Configures the DDC bus.
Data Length in Bytes: 2
Data Format: BIT
Type: R/W Word
Default Value: 5 bit LSB of SMBus address
Units:
Submit Document Feedback
42
FN7914.4
December 16, 2014
ZL9117M
BITS
PURPOSE
15:13
VALUE
Reserved
12:8
0
Broadcast Group
7:6
0 to 31
Reserved
5
DDC TX Inhibit
4:0
DDC ID
DESCRIPTION
Reserved
Group number used for broadcast events.
(i.e., Broadcast Enable and Broadcast Margin)
Set this number to the same value for all rails/devices that should respond to each
other’s broadcasted event. This function is enabled by the bits 15 and 14 in the
MISC_CONFIG command.
0
Reserved
1
DDC Transmission Inhibited
0
DDC Transmission Enabled
0 to 31
Sets the rail’s DDC ID for sequencing and fault spreading. For the current-sharing
applications, set this value the same as the ID value in ISHARE_CONFIG for all devices
in the current sharing rail.
POWER_GOOD_DELAY (D4h)
Definition: Sets the delay applied between the output exceeding the PG threshold (POWER_GOOD_ON) and asserting the PG pin. The
delay time can range from 0ms up to 500s, in steps of 125ns. A 1ms minimum configured value is recommended to apply proper debounce to this signal.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: BA00h (1ms)
Units: ms
Range: 0 to 5s
PID_TAPS (D5h)
Definition: Configures the control lop compensator coefficients.
The PID algorithm implements the following Z-domain function in Equation 8:
–1
–2
A + Bz + Cz
-------------------------------------------–1
1–z
(EQ. 8)
The coefficients A, B, and C are represented using a pseudo-floating point format similar to the VOUT parameters (with the addition of a
sign bit), defined as Equation 9:
S
E
A =  –1   2  M
(EQ. 9)
where M is a two-byte unsigned mantissa, S is a sign-bit, and E is a 7-bit two’s-complement signed integer. The 9-byte data field is
defined in the table below. S is stored as the MSB of the E byte
Data Length in Bytes: 9
Data Format: CUS
Type: R/W
Default Value: Auto Comp stores when algorithm is initiated during start up. When Auto Comp is disabled PID_TAPS can be stored via
PMBus.
Units:
BYTE
PURPOSE
DEFINITION
8
Tap C - E
Coefficient C exponent + S
7
Tap C - M [15:8]
Coefficient C mantissa, high-byte
6
Tap C - M [7:0]
Coefficient C mantissa, low-byte
5
Tap B - E
Coefficient B exponent + S
4
Tap B - M [15:8]
Coefficient B mantissa, high-byte
3
Tap B - M [7:0]
Coefficient B mantissa, low-byte
2
Tap A - E
Coefficient A exponent + S
1
Tap A - M [15:8]
Coefficient A mantissa, high-byte
0
Tap A - M [7:0]
Coefficient A mantissa, low-byte
NOTE: Data bytes are transmitted on the PMBus in the order of Byte 0 through Byte 8.
Submit Document Feedback
43
FN7914.4
December 16, 2014
ZL9117M
INDUCTOR (D6h)
Definition: Informs the device of the circuit’s inductor value. This is used in adaptive algorithm calculations relating to the inductor
ripple current.
Data Length in Bytes: 2
Data Format: L11.
Type: R/W Word
Default Value: B0E1h (0.22 µH)
Units: µH
NLR_CONFIG(D7h)
Definition: Configures the non-linear response control parameters.
Data Length in Bytes: 4
Data Format: BIT
Type: R/W
Default Value: 00000000h
Units:
BITS
PURPOSE
VALUE
DESCRIPTION
31:30
Outer threshold multiplier
O
Sets multiplier of inner threshold for outer threshold setting, O*LI and O*UI
29:27
NLR comparator threshold: Loading-Inner
LI
Sets inner threshold for a loading event to ~0.5%*(LI+1)*VOUT
26:24
NLR comparator threshold: Unloading-Inner
UI
Sets inner threshold for an unloading event to ~0.5%*(UI+1)*VOUT
23:20
Loading-Outer threshold max correction time
LOT
Sets outer threshold, maximum correction time for a loading event to
LOT*tSW/64 (s)
19:16
Loading-Inner threshold max correction time
LIT
Sets inner threshold, maximum correction time for a loading event to
LIT*tSW/64 (s)
15:12
Unloading-Outer threshold max correction time
UOT
Sets outer threshold, maximum correction time for an unloading event to
UOT*tSW/64 (s)
11:8
Unloading-Inner threshold max correction time
UIT
Sets inner threshold, maximum correction time for an unloading event to
UIT*tSW/64 (s)
7:4
Load Blanking time control
LB
Sets NLR blanking time for a loading event.
3:0
Unload Blanking time control
UB
Sets NLR blanking time for an unloading event.
TABLE 6. LOADING/UNLOADING BLANKING TIMES
LB OR UB
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
tSW/64 UNITS
1
2
3
5
9
17
33
49
65
81
97
129
161
177
193
225
OVUV_CONFIG (D8h)
Definition: Configures the output voltage OV and UV fault detection feature. The default value of 00h is recommended.
Data Length in Bytes: 1
Data Format: Bit
Type: R/W Byte
Default Value: 00h (One violation trigger VOUT fault, OV fault does not enable low-side power device)
Units: N/A
BITS
PURPOSE
VALUE
DESCRIPTION
Controls how an OV fault response shutdown sets the output
driver state
0
1
An OV fault enables the low-side power device
6:4
Not Used
0
Not Used
3:0
Defines the number of consecutive limit violations required to
declare an OV or UV fault
N
N+1 consecutive OV or UV violations initiate a fault response
7
Submit Document Feedback
44
An OV fault does not enable low-side power device
FN7914.4
December 16, 2014
ZL9117M
TEMPCO_CONFIG (DCh)
Definition: Configures the correction factor and temperature measurement source when performing temperature coefficient correction
for current sense. TEMPCO_CONFIG values are applied as negative correction to a positive temperature coefficient.
Data Length in Bytes: 1
Data Format: CUS
Type: R/W Byte
Protectable: Yes
Default Value: 2Ch (4400ppm/°C)
Equation: To determine the hex value of the Tempco Correction factor (TC) for current scale of a power stage current sensing, first
determine the temperature coefficient of resistance for the sensing element, α. This is found with the following equation:
RREF  R

RREF (TREF  T )
Where:
R = Sensing element resistance at temperature “T”
RREF = Sensing element resistance at reference temperature TREF
α = Temperature coefficient of resistance for the sensing element material
T = Temperature measured by temperature sensor, in °C
TREF = Reference temperature that α is specified at for the sensing element material
After α is determined, convert the value in units of 100ppm/°C. This value is then converted to a hex value with the following equation:
TC 
 106
100
Typical Values: Copper = 3900ppm/°C (27h), silicon = 4800ppm/°C (30h)
Range: 0 to 6300ppm/°C
BITS
PURPOSE
VALUE
DESCRIPTION
7
Selects the temp sensor source for tempco correction
0
Selects the internal temperature sensor
6:0
Sets the tempco correction in units of 100ppm/˚C for
IOUT_CAL_GAIN
TC
RSEN (DCR) = IOUT_CAL_GAIN x (1+TC x (T-25))
where RSEN = resistance of sense element
DEADTIME (DDh)
Definition: Sets the non-overlap between PWM transitions using a 2-byte data field. The most significant byte controls the high side to
low side dead time value as a single 2’s-complement signed value in units of ns. The least-significant byte controls the low side to high
side dead time value. Positive values imply a non-overlap of the FET drive on-times. Negative values imply an overlap of the FET drive
on-times. The device will operate at the dead time values written to this command when adaptive dead time is disabled, between the
minimum dead time specified in DEADTIME_CONFIG and the maximum dead time specified in DEADTIME_MAX. When switching from
adaptive dead time mode to frozen mode (by writing to bit 15 of DEADTIME_CONFIG) the frozen dead time will be whatever the last
dead time was before the device switches to frozen dead time mode.
Data Length in Bytes: 2
Data Format: CUS
Type: R/W Word
Default Value: 1018h (H-L = 16ns, L-H = 24ns)
Units: ns
Range: -15ns to 60ns
DEADTIME_CONFIG (DEh)
Definition: Configures the adaptive dead time optimization mode. Also sets the minimum dead time value for the adaptive dead time
mode range.
Data Length in Bytes: 2
Data Format: CUS
Type: R/W Word
Default Value: 8686h (Adaptive dead time disabled)
Units: N/A
Submit Document Feedback
45
FN7914.4
December 16, 2014
ZL9117M
BITS
15
14:8
7
6:0
PURPOSE
VALUE
Sets the high to low transition dead time mode
Sets the minimum H-to-L dead time
0
Adaptive H-to-L dead time control
1
Freeze the H-to-L dead time
0-126d
Sets the low to high transition dead time mode
Sets the minimum L-to-H dead time
DESCRIPTION
Limits the minimum allowed H-to-L dead time when using the
adaptive dead time algorithm (2ns resolution)
0
Adaptive L-to-H dead time control
1
Freeze the L-to-H dead time
0-126d
Limits the minimum allowed L-to-H dead time when using the
adaptive dead time algorithm (2ns resolution)
SEQUENCE (E0h)
Definition: Identifies the Rail DDC ID of the prequel and sequel rails when performing multi-rail sequencing. The device will enable its
output when its EN or OPERATION enable state, as defined by ON_OFF_CONFIG, is set and the prequel device has issued a Power-Good
event on the DDC bus. The device will disable its output (using the programmed delay values) when the sequel device has issued a
Power-Down event on the DDC bus.
The data field is a two-byte value. The most-significant byte contains the 5-bit Rail DDC ID of the prequel device. The least-significant
byte contains the 5-bit Rail DDC ID of the sequel device. The most significant bit of each byte contains the enable of the prequel or
sequel mode. This command overrides the corresponding sequence configuration set by the CONFIG pin settings.
Data Length in Bytes: 2
Data Format: BIT
Type: R/W Word
Default Value: 0000h (Prequel and Sequel disabled)
BIT
15
FIELD NAME
Prequel Enable
14:13
Reserved
12:8
Prequel Rail DDC ID
7
VALUE
Sequel Enable
6:5
Reserved
4:0
Sequel Rail DDC ID
SETTING
DESCRIPTION
0
Disable
Disable, no prequel preceding this rail.
1
Enable
Enable, prequel to this rail is defined by bits 12:8.
0
Reserved
Reserved.
0-31
DDC ID
Set to the DDC ID of the prequel rail.
0
Disable
Disable, no sequel following this rail.
1
Enable
Enable, sequel to this rail is defined by bits 4:0.
0
Reserved
Reserved.
DDC ID
Set to the DDC ID of the sequel rail.
0-31
TRACK_CONFIG (E1h)
Definition: Configures the voltage tracking modes of the device.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 00h (Tracking Disabled)
BIT
7
6:3
FIELD NAME
VALUE
Voltage Tracking Control
Tracking Ratio Control
1
Tracking Upper Limit
0
Ramp-Up Behavior
Submit Document Feedback
46
DESCRIPTION
Disable
Tracking is Disabled.
1
Enable
Tracking is Enabled.
Reserved
Reserved.
0
100%
Output Tracks at 100% ratio of VTRK input.
1
50%
Output Tracks at 50% ratio of VTRK input.
0
Target Voltage
Output Voltage is Limited by Target Voltage.
1
VTRK Voltage
Output Voltage is Limited by VTRK Voltage.
0
Track after PG
The output is not allowed to track VTRK down before power-good.
1
Track always
The output is allowed to track VTRK down before power-good.
Reserved
2
SETTING
0
FN7914.4
December 16, 2014
ZL9117M
DDC_GROUP (E2h)
Definition: This command sets which rail DDC IDs a device should listen to for fault spreading information. A device can follow multiple
DDC ID rails. Example is provided in following table.
DDC ID
Configuration
DDC_GROUP
DESCRIPTION
0
3xZL9117M Current sharing
0000000Ah
This rail will listen to Rail-1 and Rail-3
1
2xZL9117M Current sharing
00000004h
This rail will listen to Rail-2
2
1xZL9117M Single Phase
00000000h
This rail will ignore fault spread
3
1xZL9117M Single Phase
00000002h
This rail will listen to Rail-1
Note: The device/rail’s own DDC ID should not be set within the DDC_GROUP command for that device/rail.
All devices in a current share rail must shutdown for the rail to report a shutdown.
If fault spread mode is enabled in USER_CONFIG (Bit 8 set to 1), the device will immediately shut down if one of its DDC_GROUP
members fail. The device/rail will attempt its configured restart only after all devices/rails within the DDC_GROUP have cleared their
faults.
If fault spread mode is disabled in USER_CONFIG (Bit 8 cleared to 0), the device will perform a sequenced shutdown as defined by the
SEQUENCE command setting. The rails/devices in a sequencing set only attempt their configured restart after all faults have cleared
within the DDC_GROUP. If fault spread mode is disabled and sequencing is also disabled, the device will ignore faults from other
devices and stay enabled.
Data Length in Bytes: 4
Data Format: BIT
Type: R/W
Default Value: 00000000h (Ignore fault spread)
DEVICE_ID (E4h)
Definition: Returns the 16-byte (character) device identifier string.
Data Length in Bytes: 16
Data Format: ASC
Type: Block Read
Default Value: Current Firmware revision
MFR_IOUT_OC_FAULT_RESPONSE (E5h)
Definition: Configures the IOUT overcurrent fault response as defined by the table below. sets the overcurrent status bit in STATUS_IOUT.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable, and no retry)
Units:
BIT
7:6
5:3
2:0
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
Retry Setting
00
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110
The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
111
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
This time count is used for both the amount of time between retry attempts and for the
000-111 amount of time a rail is to delay its response after a fault is detected. The retry time and delay
time units are defined by the type of fault within each device.
Retry and Delay Time
Submit Document Feedback
DESCRIPTION
47
FN7914.4
December 16, 2014
ZL9117M
MFR_IOUT_UC_FAULT_RESPONSE (E6h)
Definition: Configures the IOUT undercurrent fault response as defined by the table below. Sets the undercurrent status bit in
STATUS_IOUT.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable and no retry)
Units:
BIT
7:6
5:3
2:0
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
Retry Setting
DESCRIPTION
00
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110
The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
111
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
This time count is used for both the amount of time between retry attempts and for the
000-111 amount of time a rail is to delay its response after a fault is detected. The retry time and delay
time units are defined by the type of fault within each device.
Retry and Delay Time
IOUT_AVG_OC_FAULT_LIMIT (E7h)
Definition: Sets the IOUT average overcurrent fault threshold. For down-slope sensing, this corresponds to the average of all the current
samples taken during the (1-D) time interval, excluding the Current Sense Blanking time (which occurs at the beginning of the 1-D
interval). For up-slope sensing, this corresponds to the average of all the current samples taken during the D time interval, excluding the
Current Sense Blanking time (which occurs at the beginning of the D interval). This feature shares the OC fault bit operation (in
STATUS_IOUT) and OC fault response with IOUT_ OC_FAULT_LIMIT.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: DB20h (25A)
Units: A
Range: -100 to 100A
IOUT_AVG_UC_FAULT_LIMIT (E8h)
II
Definition: Sets the IOUT average undercurrent fault threshold. For down-slope sensing, this corresponds to the average of all the
current samples taken during the (1-D) time interval, excluding the Current Sense Blanking time (which occurs at the beginning of the
1-D interval). For up-slope sensing, this corresponds to the average of all the current samples taken during the D time interval,
excluding the Current Sense Blanking time (which occurs at the beginning of the D interval). This feature shares the UC fault bit
operation (in STATUS_IOUT) and UC fault response with IOUT_ UC_FAULT_LIMIT.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: DCE0h (-25A)
Units: A
Range: -100 to 100A
Submit Document Feedback
48
FN7914.4
December 16, 2014
ZL9117M
MISC_CONFIG (E9h)
Definition: Sets options pertaining to advanced features.
Data Length in Bytes: 2
Data Format: BIT
Type: R/W Word
Default Value: 0800h
Units:
BITS
PURPOSE
VALUE
DESCRIPTION
15
Broadcast Margin
(see DDC_CONFIG)
0
Disabled
1
Enabled
14
Broadcast Enable
(see DDC_CONFIG)
0
Disabled
1
Enabled
00
Reserved
00
DCR = 25mV
01
DCR = 35mV
10
DCR = 50mV
11
Reserved
000
Reserved
0
Disabled
1
Enabled, enter diode emulation at light loads to improve efficiency
13:12
11:10
9:7
6
Reserved
I-sense gain factor
Reserved
Diode Emulation
5:2
Reserved
1
Snapshot
0
Reserved
0000
Reserved
0
Disabled
1
Enabled
0
Reserved
SNAPSHOT (EAh)
Definition: The SNAPSHOT command is a 32-byte read-back of parametric and status values. It allows monitoring and status data to be
stored to flash either during a fault condition or via a system-defined time using the SNAPSHOT_CONTROL command. In case of a fault,
last updated values are stored to the flash memory. Use SNAPSHOT_CONTROL command to read stored values.
Data Length in Bytes: 32
Data Format: BIT
Type: Block Read
BYTE NUMBER
31:22
VALUE
PMBUS COMMAND
FORMAT
Reserved
Reserved
00h
21
Manufacturer Specific Status Byte
STATUS_MFR_SPECIFIC (80h)
Byte
20
CML Status Byte
STATUS_CML (7Eh)
Byte
19
Temperature Status Byte
STATUS_TEMPERATURE (7Dh)
Byte
18
Input Status Byte
STATUS_INPUT (7Ch)
Byte
17
Iout Status Byte
STATUS_IOUT (7Bh)
Byte
16
Vout Status Byte
STATUS_VOUT (7Ah)
Byte
15:14
Switching Frequency
READ_FREQUENCY (95h)
L11
13:12
External Temperature
READ_TEMPERATURE_2 (8Eh)
L11
11:10
Internal Temperature
READ_TEMPERATURE_1 (8Dh)
L11
9:8
Duty Cycle
READ_DUTY_CYCLE (94h)
L11
7:6
Peak Current
N/A
L11
Submit Document Feedback
49
FN7914.4
December 16, 2014
ZL9117M
BYTE NUMBER
VALUE
PMBUS COMMAND
FORMAT
5:4
Load Current
READ_IOUT (8Ch)
L11
3:2
VOUT
READ_VOUT (8Bh)
L16u
1:0
VIN
READ_VIN (88h)
L11
BLANK_PARAMS (EBh)
Definition: Returns a 16-byte string which indicates which parameter values were either retrieved by the last RESTORE operation or
have been written since that time. Reading BLANK_PARAMS immediately after a restore operation allows the user to determine which
parameters are stored in that store. Index to read BLANK_PARAM is provided in “PMBus Command Summary” on page 20. A one
indicates the parameter is not present in the store and has not been written since the RESTORE operation.
Data Length in Bytes: 16
Data Format: BIT
Type: Default Value: FF...FFh
PHASE_CONTROL (F0h)
Definition: This command controls Phase adding/dropping when the device is setup for current sharing.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W byte
VALUE
DESCRIPTION
00h
The device phase is disabled or dropped
01h
The device phase is active or added
SNAPSHOT_CONTROL (F3h)
Definition: Writing a 01 will cause the device to copy the current SNAPSHOT values from NVRAM to the 32-byte SNAPSHOT parameters.
Writing a 02 will cause the device to write the current SNAPSHOT values to NVRAM. Read from NVRAM (writing a 01) does not work if
SNAPSHOT is enabled in MISC_CONFIG. To read from NVRAM, the device has to be disabled.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W byte
VALUE
DESCRIPTION
01h
Move parametric and status values from Flash to the RAM
02h
Move latest parametric and status values from RAM to the Flash
RESTORE_FACTORY (F4h)
Definition: Restores the device to the hard-coded Factory default values and pin strap definitions. The device retains the DEFAULT and
USER stores for restoring. Security level is changed to Level 1 following this command.
Data Length in Bytes: 0
Data Format: N/A
Type: Send Byte
Default Value: N/A
Units: N/A
MFR_VMON_OV_FAULT_LIMIT (F5h)
Definition: Reads the VDRV OV fault threshold.
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: CB80h (7V)
Units: V
Range: 0 to 19V
Submit Document Feedback
50
FN7914.4
December 16, 2014
ZL9117M
MFR_VMON_UV_FAULT_LIMIT (F6h)
Definition: Reads the VDRV UV fault threshold
Data Length in Bytes: 2
Data Format: L11
Type: R/W Word
Default Value: CA40h (4.5V)
Units: V
Range: 0 to 19V
MFR_READ_VMON (F7h)
Definition: Reads the VDRV voltage.
Data Length in Bytes: 2
Data Format: L11
Type: Read Word
Default Value: N/A
Units: V
MFR_VMON_OV_FAULT_RESPONSE (F8h)
Definition: Configures the VDRV overvoltage fault response.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable and no retry)
Units: N/A
BIT
7:6
5:3
2:0
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
Retry Setting
DESCRIPTION
00
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110
The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
111
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
This time count is used for both the amount of time between retry attempts and for the
000-111 amount of time a rail is to delay its response after a fault is detected. The retry time and delay
time units are defined by the type of fault within each device.
Retry and Delay Time
MFR_VMON_UV_FAULT_RESPONSE (F9h)
Definition: Configures the VDRV undervoltage fault response.
Data Length in Bytes: 1
Data Format: BIT
Type: R/W Byte
Default Value: 80h (Disable and no retry)
Units: N/A
Submit Document Feedback
51
FN7914.4
December 16, 2014
ZL9117M
BIT
7:6
5:3
2:0
FIELD NAME
VALUE
Response Behavior:
Sets the related fault bit in the
status registers. Fault bits are
only cleared by the
CLEAR_FAULTS command.
Retry Setting
DESCRIPTION
00
Continuous operation (Ignore fault)
01
Delay, Disable and Retry
Delay time is specified by bits [2:0] and retry attempt is specified in bits [5:3].
10
Disable and Retry according to the setting in bits [5:3].
11
Output is disabled while the fault is present. Output is enabled when the fault condition no
longer exists.
000
No Retry. The output remains disabled until the device is restarted.
001-110
The PMBus device attempts to restart the number of times set by these bits. The time between
the start is set by the value in bits [2:0].
111
Attempts to restart continuously, without checking if the fault is still present, until it is disabled,
bias power is removed, or another fault condition causes the unit to shut down.
This time count is used for both the amount of time between retry attempts and for the
000-111 amount of time a rail is to delay its response after a fault is detected. The retry time and delay
time units are defined by the type of fault within each device.
Retry and Delay Time
SECURITY_LEVEL (FAh)
Definition: The device provides write protection for individual commands. Each bit in the UNPROTECT parameter controls whether its
corresponding command is writeable (commands are always readable). If a command is not writeable, a password must be entered in
order to change its parameter (i.e., to enable writes to that command). There are two types of passwords, public and private. The public
password provides a simple lock-and-key protection against accidental changes to the device. It would typically be sent to the device in
the application prior to making changes. Private passwords allow commands marked as non-writeable in the UNPROTECT parameter to
be changed. Private passwords are intended for protecting Default-installed configurations and would not typically be used in the
application. Each store (USER and DEFAULT) can have its own UNPROTECT string and private password. If a command is marked as
non-writeable in the DEFAULT UNPROTECT parameter (its corresponding bit is cleared), the private password in the DEFAULT Store must
be sent in order to change that command. If a command is writeable according to the Default UNPROTECT parameter, it may still be
marked as non-writeable in the User Store UNPROTECT parameter. In this case, the User private password can be sent to make the
command writeable.
The device supports four levels of security. Each level is designed to be used by a particular class of users, ranging from module
manufacturers to end users, as discussed below. Levels 0 and 1 correspond to the public password. All other levels require a private
password. Writing a private password can only raise the security level. Writing a public password will reset the level down to 0 or 1.
Figure 21 shows the algorithm used by the device to determine if a particular command write is allowed.
Submit Document Feedback
52
FN7914.4
December 16, 2014
ZL9117M
Write
Attempted
Always
Writeable
?
Y
N
Read
Only
?
Y
N
Security
Level == 3
?
Y
N
Default
UNPROTECT
== 0
?
Y
N
Security
Level == 2
?
Y
N
User
UNPROTECT
== 0
?
Y
N
Write
Prohibited
N
Security
Level == 1
?
Y
Write
Allowed
FIGURE 21. ALGORITHM USED TO DETERMINE WHEN A COMMAND IS WRITEABLE
Security Level 3 – Module Vendor
Level 3 is intended primarily for use by Module vendors to protect device configurations in the Default Store. Clearing a UNPROTECT bit
in the Default Store implies that a command is writeable only at Level 3 and above. The device’s security level is raised to Level 3 by
writing the private password value previously stored in the Default Store. To be effective, the module vendor must clear the UNPROTECT
bit corresponding to the STORE_DEFAULT_ALL and RESTORE_DEFAULT commands. Otherwise, Level 3 protection is ineffective since
the entire store could be replaced by the user, including the enclosed private password.
Security Level 2 – User
Level 2 is intended for use by the end user of the device. Clearing a UNPROTECT bit in the User Store implies that a command is
writeable only at Level 2 and above. The device’s security level is raised to Level 2 by writing the private password value previously
stored in the User Store. To be effective, the user must clear the UNPROTECT bit corresponding to the STORE_USER_ALL,
RESTORE_DEFAULT_ALL, STORE_DEFAULT_ALL, and RESTORE_DEFAULT commands. Otherwise, Level 2 protection is ineffective since
the entire store could be replaced, including the enclosed private password.
Security Level 1 – Public
Level 1 is intended to protect against accidental changes to ordinary commands by providing a global write-enable. It can be used to
protect the device from erroneous bus operations. It provides access to commands whose UNPROTECT bit is set in both the Default and
User Store. Security is raised to Level 1 by writing the public password stored in the User Store using the PUBLIC_PASSWORD
command. The public password stored in the Default Store has no effect.
Submit Document Feedback
53
FN7914.4
December 16, 2014
ZL9117M
Security Level 0 - Unprotected
Level 0 implies that only commands which are always writeable (e.g., PUBLIC_PASSWORD) are available. This represents the lowest
authority level and hence the most protected state of the device. The level can be reduced to 0 by using PUBLIC_PASSWORD to write
any value which does not match the stored public password.
Data Length in Bytes: 1
Data Format: Hex
Type: Read Byte
Default Value: 01h
PRIVATE_PASSWORD (FBh)
Definition: Sets the private password string.
Data Length in Bytes: 9
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Default Value: 000000000000000000h
PUBLIC_PASSWORD (FCh)
Definition: Sets the public password string.
Data Length in Bytes: 4
Data Format: ASCII. ISO/IEC 8859-1
Type: Block R/W
Default Value: 00000000h
UNPROTECT (FDh)
Definition: Sets a 256-bit (32-byte) parameter which identifies which commands are to be protected against write-access at lower
security levels. Each bit in this parameter corresponds to a command according to the command’s code. The command with a code of
00h (PAGE) is protected by the least-significant bit of the least-significant byte, followed by the command with a code of 01h and so
forth. Note that all possible commands have a corresponding bit regardless of whether they are protectable or supported by the device.
Clearing a command’s UNPROTECT bit indicates that write-access to that command is only allowed if the device’s security level has
been raised to an appropriate level. The UNPROTECT bits in the DEFAULT store require a security level 3 or greater to be writeable. The
UNPROTECT bits in the USER store require a security level of 2 or higher.
Data Length in Bytes: 32
Data Format: BIT
Type: Block R/W
Default Value: FF…FFh
Submit Document Feedback
54
FN7914.4
December 16, 2014
ZL9117M
Firmware Revision History
FIRMWARE REVISION CODE
CHANGE DESCRIPTION
FC04
NOTE
Not recommended for a new design.
FC05
1. Fixed bug: clear VMON_UV_WARNING when VMON (VDRV
voltage is ramped up with a delay of >50ms from VIN;
Recommended for a new design.
2. Fixed bug: PID Taps in DEFAULT STORE does not work if PID
Taps are stored in USER STORE on issuing RESTORE DEFAULT
3. Fixed bug: added ADC flash trim registers in the calibration
table
4. MAX_DUTY = 91.375%
5. OVUV_CONFIG = 00h
6. FREQUENCY_SWITCH = 571kHz (SYNC pin open)
7. VOUT_OV_FAULT_LIMIT = 1.15 x VOUT_COMMAND
8. VOUT_UV_FAULT_LIMIT = 0.85 x VOUT_COMMAND
9. IOUT_OC_FAULT_LIMIT = 37A
10. IOUT_UC_FAULT_LIMIT = -37A
11. VIN_OV_FAULT_LIMIT = 14.5V
12. VIN_OV_WARN_LIMIT = 13.2V
13. VIN_UV_WARN_LIMIT = 4.375V
14. VIN_UV_FAULT_LIMIT = 4V
15. TON_RISE = 10ms
16. TON_FALL = 10ms
17. AUTO_COMP_CONFIG = 69h
18. MFR_CONFIG = 6A11h
19. USER_CONFIG = 2011h
20. INDUCTOR = 0.22µH
21. TEMPCO_CONFIG = 2Ch
22. DEADTIME = 1018h (H to L = 16ns, L to H = 24ns)
23. DEADTIME_CONFIG = 8686h, freeze deadtimes
24. DEVICE_ID = ZL9117M-002-FC05
25. IOUT_AVG_OC_FAULT_LIMIT=25A
26. IOUT_AVG_UC_FAULT_LIMIT=-25A
27. MISC_CONFIG = 0800h
For additional products, see www.intersil.com/en/products.html
Intersil products are manufactured, assembled and tested utilizing ISO9001 quality systems as noted
in the quality certifications found at www.intersil.com/en/support/qualandreliability.html
Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time
without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be
accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third
parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
Submit Document Feedback
55
FN7914.4
December 16, 2014
ZL9117M
Revision History
The revision history provided is for informational purposes only and is believed to be accurate, but not warranted. Please go to web to make sure you
have the latest revision.
DATE
REVISION
CHANGE
December 16, 2014
FN7914.4
Removed all references to AN2033
Electrical Spec Table - Driver Supply Current , IVDRV TYP from 25 to 30 and in conditions changed “No Load”
to IOUT = 17A
Switching Frequency Range MIN from 500 to 400
Added Firmware Revision History column to ordering information on page 4 and note referencing the history.
Made correction to Part Marking in ordering information for ZL9117MAIRZ from ZL9117MA to ZL9117M.
Updated Efficiency Curves (Figures 2 through 4)for various voltages with additional information on page 9.
“Switching Frequency and PLL” on page 12 - added text and tables after 1st paragraph.
Updated Equations in “Output Capacitor Selection” on page 18
Added PMBus Command Summary and Description beginning on page 20.
Updated PMBus Command Summary table
Updated “Snapshot Parameter Capture” on page 17.
Added lines 4 to 27 in FCO5 change descriptions in “Firmware Revision History” on page 55.
May 10, 2013
FN7914.3
page 4: Added ZL9117MAIRZ to ordering information table.
Page 6 - Electrical Spec Table changed in Input and Supply Characteristics section
Driver Supply current, IVDRV - Conditions, Typ and Unit
From: Not Switching, 190, µA
To: VDRV = 6V, VOUT = 1.0V, FSW = 571kHz, No Load, 25, mA
December 4, 2012
FN7914.2
Changed CIN and COUT values in Figure 1 on page 1.
Removed Notes from Figure 1 on page 1. Moved to pin description table (page 3) and typical application
(page 6).
Line and load regulation on output characteristic (Electrical Specifications) were combined to provide output
voltage accuracy specification.
Added “ZL9117M Internal Block Diagram” on page 5.
Added “Typical Application - Single Module” on page 6.
Added “Output Voltage Selection” on page 11.
Added “Output Voltage Tracking” on page 15.
Added “Output Capacitor Selection” and “Input Capacitor” on page 18.
Updated first bullet in “Monitoring via I2C/SMBus” on page 17.
Updated Figure 19 on page 18.
October 12, 2011
FN7914.1
On page 1:
Changed ".. required for a complete DC/DC power solution." in first paragraph to ".. required for a highly
integrated DC/DC power solution.”
Added "This power module has built-in auto-compensation algorithms, which eliminates the need for manual
compensation design work." to first paragraph.
Changed "The ZL9117M features internal compensation.." to "The ZL9117M features auto-compensation.."
Added "Auto Compensating PID Filter" to “Features”.
August 30, 2011
FN7914.0
Initial Release
About Intersil
Intersil Corporation is a leading provider of innovative power management and precision analog solutions. The company's products
address some of the largest markets within the industrial and infrastructure, mobile computing and high-end consumer markets.
For the most updated datasheet, application notes, related documentation and related parts, please see the respective product
information page found at www.intersil.com.
You may report errors or suggestions for improving this datasheet by visiting www.intersil.com/ask.
Reliability reports are also available from our website at www.intersil.com/support
Submit Document Feedback
56
FN7914.4
December 16, 2014
L21.15x15
21 LEAD QUAD FLAT NO-LEAD PLASTIC PACKAGE (PUNCH QFN)
Rev 2, 8/11
X4
0.2 S AB
16x 0.80
57
7.25
18
2
3
4
5
6
7
8
8.30
3.10
12.05
1.25
4.20
16
16
14
0.80
9
15
2.95
1.95
13 14 15
13 12 11 10
4.65
5.65
1 x 0.76
15.0±0.2
15.8±0.2
B
0.05
8x 1.80±0.05
TOP VIEW
S AB
BOTTOM VIEW
A
S 0.2
FN7914.4
December 16, 2014
S
SIDE VIEW
18
17
16
A A A
19 20 21 1
2
3
4
5
6
7
8
14
0.50
S 0.05
B
ND
A A A A A A A A
AROU
3.5±0.2
5° ALL
B
9
15
B
A A A A A A
A A A
13
A A A
B
12 11 10
C C
B
A:1.3±0.1
B:2.6±0.1
C:1.13±0.1
ZL9117M
9
10 11 12
19 20 21 1
17 6.25
4.40
15.8±0.2
17
15.0±0.2
2
3
4
5
6
7
8
2.95
18
1.95
1 21 20 19
17x 0.75
9x 1.90±0.05
A
33x 0.50
Submit Document Feedback
Package Outline Drawing
6.90
6.30
5.60
5.00
4.30
3.70
3.00
2.40
0.55
0
0.05
0.90
1.50
2.20
2.80
3.50
4.10
6.78
8.20
6.90
8.30
5.60
4.80
8.30
4.30
6.90
3.50
3.00
5.60
1
2
2.20
1.70
0.90
0.40
0
4.95
4.15
1.05
0.25
0
58
0.40
0.90
1.70
2.20
4.150
4.95
5.60
3.00
4.80
8.30
8.30
0.15
0.65
1.45
2.25
4.85
5.65
6.90
3.60
2.90
1
2
2.30
1.60
1.00
0.30
0
0.30
1.00
1.60
2.30
2.90
4.90
5.50
6.10
Unit: mm
Tolerance: ±0.01mm
Unit: mm
Tolerance: ±0.01mm
8.20
6.82
5.50
5.05
4.05
3.60
2.90
2.30
1.60
1.15
0.15
0
0.30
1.00
1.60
2.30
2.90
3.60
4.05
5.05
5.50
6.82
8.20
STENCIL PATTERN WITH SQUARE PADS-1
6.48
3.42
4.02
0
0.95
TYPICAL RECOMMENDED LAND PATTERN
6.37
5.25
3.85
1
2
1.35
0.75
0
0.05
1.65
2.25
3.85
5.25
6.375
0
1.25
1.85
3.85
4.45
5.80
NOTES:
1.
Dimensions are in millimeters.
2.
Unless otherwise specified, tolerance : Decimal ± 0.2;
Body Tolerance ±0.2mm
3.
The configuration of the pin #1 identifier is optional, but must be
located within the zone indicated. The pin #1 indentifier may be
either a mold or mark feature.
Unit: mm
Tolerance: ±0.01mm
0
0.75
2.45
2.55
3.05
4.215
4.55
4.815
5.80
6.33
6.475
FN7914.4
December 16, 2014
STENCIL PATTERN WITH SQUARE PADS-2
STENCIL PATTERN WITH SQUARE PADS-2
ZL9117M
8.30
6.10
5.50
4.70
4.205
3.445
2.95
2.15
0.65
0
5.60
6.00
6.10
5.50
4.90
4.20
6.20
5.40
4.80
4.105
3.545
2.85
2.25
0.55
0
0.75
1.35
2.35
2.80
3.50
4.10
6.10
6.70
8.20
0.15
0.65
4.20
7.00
6.20
5.70
4.90
4.40
3.60
3.10
2.30
0.65
0
Submit Document Feedback