Mounting:
The touch panel must to be mounted onto LCD panel by double-side sponge tape.
It will keep the touch panel away from LCD metal frame to prevent electric interfere. We
strong recommend using the thicker than 2.5mm tape to mount touch panel on the LCD
display for the optimal performance of the touch sensor. Never use the tape thickness less
than 1.5mm.
Sponge tape between touch panel and LCD monitor
Power Systems – The Power Solution
Web: www.Power-Systems.de
Email: [email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 – 800
Page (1/6)
Version 1.0.0, 20th July 2010
Touch Screen
Installation Instruction
Basic Mounting Procedure:
A sample for small size
The position of controller
Power Systems – The Power Solution
Web: www.Power-Systems.de
Email: [email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 – 800
Page (2/6)
Version 1.0.0, 20th July 2010
Touch Screen
Installation Instruction
Controller Plug-In:
Connect to the PC-side
Connect to the panel-side
Pin out of USB and RS232
Power Systems – The Power Solution
Web: www.Power-Systems.de
Email: [email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 – 800
Page (3/6)
Version 1.0.0, 20th July 2010
Touch Screen
Installation Instruction
ESD discharge path:
The controllers must be mounted inside the systems and kept away from high voltage,
electronics, high power cables and LCD inverter. The tail of the touch screen must not
cross the inverter.
The controller has internal protection to +/-27KV for ESD discharges to the screen. Use
diameter 3mm metal screws to mount the controller board at its two diagonal mounting
holes. At least one of the mounting holes should be grounded through the metal part of the
system for ESD discharge path.
Power Systems – The Power Solution
Web: www.Power-Systems.de
Email: [email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 – 800
Page (4/6)
Version 1.0.0, 20th July 2010
Touch Screen
Installation Instruction
Tail Considerations:
a) Never pick up the touch panel by holding the tail.
b) If necessary, the tail can be bent only once.
c) Never bend the tail close to the edge within 5 mm from the panel edge.
d) Do not route the tail near the backlight inverter of the LCD panel.
Touch Panel Considerations:
The glass has been grinding in all corners and the edges to prevent the crack and damage
from installation.
But it’s still not so strong and please takes care when mounting.
Broken edge
Unbroken edge
Power Systems – The Power Solution
Web: www.Power-Systems.de
Email: [email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. : + 49 / 70 62 / 67 59 - 6
Fax: + 49 / 70 62 / 67 59 – 800
Page (5/6)
Version 1.0.0, 20th July 2010
Touch Screen
Installation Instruction
General:
1. Front bezel: the noise may come from the front bezel (epically metal bezel). For plastic
bezel, do not touch the touch panel in any place. For metal type of bezel, please keep
2.5mm from the touch panel and the metal bezel must be well grounded.
2. Sealing tape: 3M VHB 4962 single-side sponge tape as the sealing tape.
3. Touch panel: Keep away from the parts of the LCD module. We also provide the
product with back side shielding coating to reduce the noise from the system.
4. Double-Side sponge tape: Never use the tape thickness less than 1.5mm.
5. LCD panel & chassis: Keep the tail in good condition and well grounded for controller.
Inverter may be the noise sourer, too.
6. Back shield: provide the protection for controller.