NCS1 Series - power, Murata

NCS1 Series
www.murata-ps.com
Isolated 1W 4:1 Input Single Output DC/DC Converters
Order Code
NCS1S1203SC
NCS1S1205SC
NCS1S1212SC
NCS1S2403SC
NCS1S2405SC
NCS1S2412SC
FEATURES
„
UL 60950 recognised
„
4:1 Wide range voltage input
„
Operating temperature range -40°C to
105°C with derating
„
1kVDC Isolation “Hi Pot Test”
Efficiency
Input
Voltage Output Output 5V or 24V Input.
Voltage Current
Efficiency
12V Input.
Nom.
V
V
mA
Min.
%
Typ.
%
Min.
%
Typ.
%
12
12
12
24
24
24
3.3
5
12
3.3
5
12
303
200
83
303
200
83
73
76
75
76
79
80
77
79
78
78.5
82
83
71
74
75
73
77
77
75
77
79
76
80
80
Ripple and Noise
Typ.
Max.
mVp/p mVp/p
24
25
40
35
27
28
70
50
120
70
50
120
Isolation
Capacitance
SELECTION GUIDE
pF
kHrs
24
30
35
28
42
42
1020
915
1130
1217
1022
943
Units
INPUT CHARACTERISTICS
Parameter
Voltage range
Conditions
Min.
Typ.
Max.
12V input types
4.5
12
18
24V input types
9
24
36
NCS1S12XX
Input current
5V input voltage
0.26
12V input voltage
0.1
12V input voltage
0.1
24V input voltage
0.05
„
3.3V, 5V & 12V outputs
„
No electrolytic capacitors
NCS1S12XX
5
30
NCS1S24XX
5
15
Input reflected ripple
current
V
A
NCS1S24XX
„
Continuous short circuit protection
MTTF1
mA p-p
OUTPUT CHARACTERISTICS
PRODUCT OVERVIEW
Parameter
The NCS1 series of DC/DC converters offers a
single output voltage from input voltage ranges
of 4.5-18V and 9-36V. The NCS1 is housed in an
industry standard package with a standard pinout.
Rated power
All output types
Minimal load to meet datasheet specification
Voltage set point accuracy All output types
Line regulation
Low line to high line
Load regulation
All output types
Peak deviation (12.5-37.5% & 37.5-12.5% swing)
Transient response
Settling time
(within 5% Vout Nom.)
Applications include telecommunications, battery
powered systems, process control and distributed
power systems.
Conditions
Min.
Typ.
Max.
1
Units
W
±2
±0.5
0.5
5
%
%
%
%
%Vout
10
±1
2
ms
ISOLATION CHARACTERISTICS
Parameter
Conditions
Min.
Isolation test voltage
Resistance
Flash tested for 1 second
Viso = 1kVDC
1000
1
Typ.
Max.
Units
VDC
GΩ
GENERAL CHARACTERISTICS
Parameter
Conditions
Min.
Switching frequency
Control pin input
Typ.
100
Module on, pin unconnected or open collector floating
Module off
Max.
Units
400
kHz
0.8
V
1 Calculated using MIL-HDBK-217 FN2, parts stress method with nominal input voltage at full load.
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 1 of 8
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Operation
Storage
Case temperature rise above ambient
Min.
Typ.
Max.
Units
°C
15
105
125
22
-40
-50
100% Load, Nom VIN, Still Air
ABSOLUTE MAXIMUM RATINGS
Short-circuit protection (for SELV input voltages)
Control pin input voltage
Lead temperature 1.0mm from case for 10 seconds (to JEDEC JESD22-B106 ISS C)
Input voltage, NCS1 12V input types
Input voltage, NCS1 24V input types
Continuous
18V Max
260°C
25V
40V
APPLICATION NOTES
Maximum Output Capacitance
Maximum output capacitance should not exceed:
Output Voltage
V
3.3
5
12
Maximum Load Capacitance
μF
470
470
220
Start-up times
Typical start up times for this series, with a typical input voltage rise time of 2.2μs and output capacitance of 10μF, are shown in the table below. The product series will
start into the maximum output capacitance with increased start times.
Start-up times
ms
6
9
20
12
7
12
Part No.
NCS1S1203SC
NCS1S1205SC
NCS1S1212SC
NCS1S2403SC
NCS1S2405SC
NCS1S2412SC
Control Pin
The NCS1 converters have a shutdown feature which enables the user to put the converter into a low power state. The control pin connects directly to the base of an internal
transistor, and the switch off mechanism for the NCS1 works by forward biasing this NPN transistor. If the pin is left open (high impedance), the converter will be ON (there is
no allowed low state for this pin), but once a control voltage is applied with sufficient drive current, the converter will be switched OFF. A suitable application circuit is shown
below.
D1 (e.g. 1N4003) is required to provide high impedence when the signal is
low. From the NCS1 specification, the drive current to operate this function is
recommended to be 3mA, and hence the value of R1 can be derived as follows:
NCS1
VIN
R2
VC
OV
-VIN
R1
www.murata-ps.com
D1
CTRL
Q1
R1 =
VC - VD - VQ
IC
Assuming VC=5V, VD=0.7V and VQ=1V:
R1=
5 - 0.7 - 1.0
= 1100Ω
3 x 10-3
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 2 of 8
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions NCS1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The NCS1 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The NCS1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The NCS1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation to a maximum case temperature of 105°C. File number E151252
applies.
The NCS1 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
NCS1S12xxSC: 1A
NCS1S24xxSC: 0.5A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
RoHS COMPLIANCE INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature of 260ºC for 10 seconds. The pin termination finish
on this product series is Tin Plate, Hot Dipped over Matte Tin with Nickel Preplate. The series is backward compatible with Sn/Pb soldering
systems.
CHARACTERISATION TEST METHODS
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1μF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
10μF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter with an ESR of less
C2
than 100mΩ at 100 kHz
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film, ±1% tolerance
R2
50Ω BNC termination
T1
3T of the coax cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
DC/DC Converter
OSCILLOSCOPE
C1 C2 C3
+
SUPPLY
Input
-
+
R1
T1
R2
Y INPUT
Output
-
R LOAD
www.murata-ps.com
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 3 of 8
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
EFFICIENCY VS LOAD
NCS1S1203SC
NCS1S1205SC
90
80
80
70
70
60
60
40
4.5 Vin
5 Vin
12 Vin
30
18 Vin
Efficiency (%)
Efficiency (%)
50
50
4.5 Vin
40
5 Vin
12 Vin
18 Vin
30
20
20
10
10
0
0
0
10
20
30
40
50
60
70
80
90
0
100
10
20
30
40
Load (%)
50
60
70
80
90
100
Load (%)
NCS1S1212SC
NCS1S2403SC
90
90
80
80
70
70
60
Efficiency (%)
4.5 Vin
40
5 Vin
12 Vin
Efficiency (%)
60
50
18 Vin
30
50
9 Vin
12 Vin
40
24 Vin
36 Vin
30
20
20
10
10
0
0
0
10
20
30
40
50
60
70
80
90
0
100
10
20
30
40
50
60
70
80
90
100
Load (%)
Load (%)
NCS1S2405SC
NCS1S2412SC
90
90
80
80
70
70
60
9 Vin
12 Vin
40
24 Vin
36 Vin
Efficiency (%)
Efficiency (%)
60
50
50
9 Vin
12 Vin
40
24 Vin
30
30
20
20
10
10
36 Vin
0
0
0
10
20
30
40
50
Load (%)
www.murata-ps.com
60
70
80
90
100
0
10
20
30
40
50
60
70
80
90
100
Load (%)
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 4 of 8
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
TEMPERATURE DERATING
NCS1S1203SC
NCS1S1205SC
100%
100%
90%
90%
80%
70%
60%
still air
50%
100 lfm
40%
200 lfm
30%
400 lfm
Load (%)
Load (%)
80%
70%
60%
still air
50%
100 lfm
40%
200 lfm
30%
400 lfm
20%
20%
10%
10%
0%
0%
70
80
90
100
Ambient Temperature
110
80
110
OC
NCS1S2403SC
100%
100%
90%
90%
80%
70%
still air
60%
50%
100 lfm
40%
200 lfm
30%
Load (%)
80%
Load (%)
100
Ambient Temperature
NCS1S1212SC
400 lfm
70%
60%
still air
50%
100 LFM
40%
200 LFM
30%
400 LFM
20%
20%
10%
10%
0%
0%
80
90
100
110
Ambient Temperature
70
OC
75
80
85
90
95
100
Ambient Temperature
NCS1S2405SC
105
OC
NCS1S2412SC
100%
100%
90%
90%
80%
70%
60%
still air
50%
100 LFM
40%
200 LFM
30%
400 LFM
20%
Load (%)
80%
Load (%)
90
OC
70%
60%
still air
50%
100 lfm
40%
200 lfm
30%
400 lfm
20%
10%
10%
0%
70
80
90
100
Ambient Temperature
www.murata-ps.com
110
OC
0%
80
90
100
Ambient Temperature
110
OC
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 5 of 8
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
EMC FILTERING AND SPECTRA
FILTERING
The module includes a basic level of filtering, the following table shows the additional input capacitor and input inductor typically required to meet EN 55022 Curve A
Quasi-Peak EMC limit, as shown in the following plots.
Part Number
Capacitor
Inductor
NCS1S1203SC
NCS1S1205SC
NCS1S1212SC
NCS1S2403SC
NCS1S2405SC
NCS1S2412SC
330nF
330nF
2.2μF
330nF
330nF
330nF
500μH
500μH
2.2mH
500μH
500μH
500μH
www.murata-ps.com
Common Mode Choke
700μH
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 6 of 8
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
EMC FILTERING AND SPECTRA
80
70
60
50
40
30
20
10
0
1.00E+05
NCS1S1205SC
dBuV
dBuV
NCS1S1203SC
1.00E+06
1.00E+07
1.00E+08
80
70
60
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
80
70
60
50
40
30
20
10
0
1.00E+05
Frequency (Hz)
1.00E+06
1.00E+07
1.00E+08
NCS1S2412SC
dBuV
dBuV
1.00E+08
Frequency (Hz)
NCS1S2405SC
80
70
60
50
40
30
20
10
0
1.00E+05
1.00E+07
NCS1S2403SC
dBuV
dBuV
NCS1S1212SC
80
70
60
50
40
30
20
10
0
1.00E+05
1.00E+06
Frequency (Hz)
Frequency (Hz)
1.00E+06
1.00E+07
Frequency (Hz)
www.murata-ps.com
1.00E+08
80
70
60
50
40
30
20
10
0
1.00E+05
1.00E+06
1.00E+07
1.00E+08
Frequency (Hz)
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 7 of 8
NCS1 Series
Isolated 1W 4:1 Input Single Output DC/DC Converters
PACKAGE SPECIFICATIONS
MECHANICAL DIMENSIONS
PIN CONNECTIONS
21.87 [0.861] MAX
8.2 [0.323] MAX
Pin
Function
Single
1
2
3
6
7
-VIN
+VIN
Control
+VOUT
-VOUT
TUBE OUTLINE DIMENSIONS
0.50 (0.0197)
NCS1S1205SC
11.30 [0.445] MAX
XYYWW
12.30 (0.484)
0.40 [0.016] MIN
4.10±0.50
[0.161±0.020]
1 2 3
0.75 (0.0295)
±0.20 (0.0079)
6 7
0.50±0.05
[0.020±0.002]
2.54 [0.100]
5.00 (0.1969)
2.00 (0.0787)
2.00 (0.0787)
8.20
(0.3228)
15.24 [0.600]
All dimensions in millimetres ±0.5 (inches ±0.01).
Tube length: 520±2 (20.47 inches ±0.079).
3.52
2.87
0.25±0.05 [0
0.113 ]
[0.139
RECOMMENDED FOOTPRINT DETAILS
.010±0.002]
2.62
1.92
Quantity: 23
2.54 [0.100]
0.076 ]
[0.103
x6 HOLES
Ø 0.045
0.039
Ø 1.15
1.00
2.54 [0.100]
All dimensions in millimetres (inches) ± 0.5 (0.020) except pin to pin tolerance ±0.25 (0.010).
All pins on a 2.54 (0.100) pitch and within 0.25 (0.010) of true position.
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
www.murata-ps.com/support
Weight: 3.3g
[
]
0.1
All dimensions in mm (inches) ±0.25 (± 0.010).
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2015 Murata Power Solutions, Inc.
All enquiries: www.murata-ps.com/support
KDC_NCS1.D01 Page 8 of 8