XFPM,XFHM Data sheet - www . czujniki . pl

XFPM,XFHM Data sheet
Pre-amplified/5V Excitation/Gauge
Features
.
.
.
.
.
Applications
. Industrial instrumentation
. Pressure switch, Pneumatic device
Two accuracy ranks, 1.5 FS and 2.5 FS available
Volt level output
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
Non-corrosive liquid measurable (XFPMC, XFHMC only)
. Medical device
Part number for ordering
XFPM C - 025KP G R H
Accuracy No mark :
H
:
Model
XFPM
XFHM
Rated pressure (Pa)
Available pressure media
No mark : Non-corrosive gas only Pressure type
C : Non-corrosive gas and liquid G : Gauge (Positive pressure)
Terminal leads direction
(See Outline Diagram)
No mark :
GV : Gauge (Negative pressure)
GW : Gauge (Bipolar pressure)
Pressure type
2.5 FS
1.5 FS
R
:
Gauge pressure
XFPM
XFHM
Dual-In-line-Package (DIP)
Horizontal pressure port DIP
Model
Package configuration
Measurable pressure range (kPa)
100 100
0
100
0 25
0 50
0 100
0 200
0 1000
XFPM-100KPGW(H)
XFPM-100KPGV(H)
XFPM-025KPG(H)
XFPM-050KPG(H)
XFPM-100KPG(H)
XFPM-200KPG(H)
XFPM-001MPG(H)
XFPM-100KPGWR(H)
XFPM-100KPGVR(H)
XFPM-025KPGR(H)
XFPM-050KPGR(H)
XFPM-100KPGR(H)
XFPM-200KPGR(H)
XFPM-001MPGR(H)
XFPMC-100KPGW(H)
XFPMC-100KPGV(H)
XFPMC-025KPG(H)
XFPMC-050KPG(H)
XFPMC-100KPG(H)
XFPMC-200KPG(H)
XFPMC-001MPG(H)
100KPGW(H)
100KPGV(H)
025KPG(H)
Part number for ordering
XFPMC-100KPGWR(H)
XFHM-100KPGW(H)
XFPMC-100KPGVR(H)
XFHM-100KPGV(H)
XFPMC-025KPGR(H)
XFHM-025KPG(H)
XFPMC-050KPGR(H)
XFHM-050KPG(H)
XFPMC-100KPGR(H)
XFHM-100KPG(H)
XFPMC-200KPGR(H)
XFHM-200KPG(H)
XFPMC-001MPGR(H)
XFHM-001MPG(H)
XFHM-100KPGWR(H)
XFHM-100KPGVR(H)
XFHM-025KPGR(H)
XFHM-050KPGR(H)
XFHM-100KPGR(H)
XFHM-200KPGR(H)
XFHM-001MPGR(H)
XFHMC-100KPGW(H)
XFHMC-100KPGV(H)
XFHMC-025KPG(H)
XFHMC-050KPG(H)
XFHMC-100KPG(H)
XFHMC-200KPG(H)
XFHMC-001MPG(H)
XFHMC-100KPGWR(H)
XFHMC-100KPGVR(H)
XFHMC-025KPGR(H)
XFHMC-050KPGR(H)
XFHMC-100KPGR(H)
XFHMC-200KPGR(H)
XFHMC-001MPGR(H)
200KPG(H)
001MPG(H)
Unit
Specifications
Model/Rated pressure
050KPG(H)
100KPG(H)
Recommended operating conditions
Pressure type
Gauge pressure
100
100
25
50
100
200
1000
Rated pressure
1.020
1.020
0.255
0.510
1.020
2.040
10.20
Measurable pressure range
100 100
0
100
0 25
0 50
0 100
0 200
0 1000
Pressure media 1
XFPM, XFHM : Non-corrosive gas only, XFPMC, XFHMC : Non-corrosive gas and liquid
Excitation voltage
5.0 0.25
Absolute maximum rating
1.5times of rated pressure
Maximum load pressure
Twice of rated pressure
Maximum excitation voltage
8
Operating temperature
40 125
Storage temperature
40 125
Operating humidity
30 80 (No dew condensation)
Electric performances/characteristics(Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 )
Current consumption
less than 10
Output impedance
less than 10
Source current
less than 0.2
Sink current
less than 2
Mechanical response time
2 (For the reference)
Full scale span voltage
4.5
Offset voltage 2
0.2 0.1125, 0.2 0.0675(H)
Full scale span voltage 2
4.7 0.1125, 4.7 0.0675(H)
Accuracy 2
2.5, 1.5(H)
Note ;
1) Please consult us available liquid pressure media when you choose the C models.
2) Excluding input voltage error.
1
kPa
kg/cm2
kPa
VDC
VDC
RH
mA
mA
mA
msec
V
V
V
FS/0 85
XFPM,XFHM Data sheet
Pre-amplified/5V Excitation/Gauge
Outline dimensions
unit : mm
XFPM
4
5
6
3
2
1
C0.5
3
2
4
3
14
1
4.5
0.6
Vent hole
R1.5
15.24(600mil)
5
Pressure port
0.8
max 15
2.2
0.5
6
8
5
0.2
4
12
Terminal leads
Labelled faceplate
6.8
2.8
Recommended footprint for PCB
6- 1.8(Diameter of lands)
2.54 2.54
0.5
60
1.2
2.54 2.54
6- 0.9(Diameter of through holes)
15.2
(unit : mm)
unit : mm
XFPM-R
4
0.2
8
0.8
Pressure port
2.2
0.5
3
14
R1.5
4
5
6
3 2
4.5
1
15.24(600mil)
5
max 15
6
4
5
12
C0.5
1
2
0.6
Vent hole
3
Terminal leads
Recommended footprint for PCB
2.54 2.54
6- 0.9(Diameter of through holes)
6- 1.8(Diameter of lands)
2.54 2.54
60
1.2
0.5
Labelled faceplate
2.8
6.8
15.2
2
(unit : mm)
XFPM,XFHM Data sheet
Pre-amplified/5V Excitation/Gauge
Outline dimensions
unit : mm
2.54 2.54
1
2
3
6
5
4
5.5
XFHM
Pressure port
(14)
0.25
1
0.6
3.4
2.6
7.6
3.2
15
6
10.15
1.2
Vent hole
8
Labelled faceplate
6
5
Recommended footprint for PCB
4
6- 1(Diameter of through holes)
2.54 2.54
8
6- 1.8(Diameter of lands)
1
2
3
10
unit : mm
2.54 2.54
XFHM-R
2
3
6
5
4
5.5
1
(unit : mm)
Pressure port
(14)
1.2
4.7
2.6
3.4
(7.6)
1.55
3.2
1
6
0.6
0.25
Recommended footprint for PCB
8
Labelled faceplate
6
5
4
6- 1(Diameter of through holes)
2.54 2.54
8
6- 1.8(Diameter of lands)
1
15
Vent hole
10.16
1
2
3
10
3
(unit : mm)
Pre-amplified/5V Excitation/Gauge
XFPM,XFHM Data sheet
Connection diagram
XFPM, XFHM
Vcc(DC5V)
Vcc
Vout
Vout
GND
C2
C1
GND
Remarks :
1) C1 : Connect 680pF capacitor within 2cm distance from
leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads.
3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or
each other.
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
4
E-mail : [email protected]