RMB962 PCB power relays

RMB962
PCB power relays
57
BISTABLE
• Height 15 mm
• for PCB mounting
• Insulation 4 kV / 8 mm
• High switching capacity
• Wash proof IP 67 version
• Low power consumption
• 2-coil bistable relays
Contacts
Contact number & arrangement
Contact material
Max. switching voltage
Min. switching voltage
AC/DC
1C/O, 1NO
AgCdO, AgSnO2, AgCdO/Au 3,5 µm
400 V / 300 V
24 V AgCdO, 24 V AgSnO2,
AgCdO/Au 3,5 µm - contact Relpol S.A.
Rated load
Min. switching current
AC1
8 A / 250 V AC
100 mA AgCdO, 100 mA AgSnO2,
AgCdO/Au 3,5 µm - contact Relpol S.A.
Max. inrush current
Rated current
Max. breaking capacity
Min. breaking capacity
AC1
10 A
8A
2 000 VA
2,4 W AgCdO, 2,4 W AgSnO2,
AgCdO/Au 3,5 µm - contact Relpol S.A.
Resistance
Max. operating frequency
• at rated load
• no load
≤ 100 mΩ
AC1
3 600 cycles/hour
20 000 cycles/hour
Coil
Rated voltage
Operating range of supply voltage
Duration of supply voltage pulse
DC
3...24 V
see Table 1
min. 10 ms; max. 5 s
Insulation
Insulation category
Insulation rated voltage
Insulation max. voltage
Dielectric strength
• coil - contact
• contact - contact
Contact - coil distance
• clearance
• creepage
C250
250 V AC
400 V AC
4 000 V AC
1 000 V AC
≥ 8 mm
≥ 8 mm
General data
Operating time (typical value)
Release time (typical value)
Electrical life
• resistive AC1
• cos φ = 0,4
Mechanical life (cycles)
Dimensions (L x W x H)
Weight
Ambient temperature
• storing
• operating
Cover protection category
Vibration resistance
Solder bath temperature
Soldering time
10 ms
7 ms
> 105
8 A, 250 V AC
> 105
5 A, 250 V
> 3 x 107
29 x 10 x 15 mm
10 g
-40...+80 oC
-40...+70 oC
IP 67
10 g 10...100 Hz
max. 270 oC
max. 5 s
Standard contact material marked with bolt type.
Note: At IP 67 version it is recommended that the vent pin is removed after soldering and washing process.
www.relpol.com.pl
RMB962
PCB power relays
58
Mounting
Relays RMB962 are mounted anly on PCBs.
www.relpol.com.pl
RMB962
PCB power relays
59
see Table 1 page 58
www.relpol.com.pl