Light Management Systems: Energy Savings.

www.osram.com/lms
Light Management Systems:
Energy Savings.
Complete LMS range for daylight-dependent
and presence-dependent lighting.
ENERGY-SAVING LMS
Good for our climate and good for
your business: LMS Energy Savings.
© spectral Gesellschaft für Lichttechnik mbH; Anin Jeromin Fitilidis & Partner,
Architekten & Ingenieure; LOOK UP GmbH & Co. KG, Agentur für Kommunikation
Constantly rising energy costs and a growing focus on climate protection are driving the need
for energy savings more and more into the forefront. Particularly in applications with high energy
consumption, energy-efficient lighting solutions are assuming an increasingly important role.
Only as much light as needed.
In daylight-dependent and motion/presence-dependent
lighting control systems, the available daylight in a room is
supplemented as needed by artificial light from luminaires
with dimmable electronic ballasts. Light sensors detect the
lighting level comprising artificial light and natural daylight.
The groups of luminaires are controlled according to their
position in the room and the amount of available daylight,
so that a predefined lighting level is maintained. Users can
adjust the lighting at any time to a level that meets their
specific needs. If a motion/presence sensor is also used,
the lighting is automatically switched on only when someone
enters an empty room or if someone is in the room. This
significantly increases the potential energy savings even
further.
2
For intelligent luminaires to lighting solutions
for open-plan offices.
In the LMS Energy Savings sector, OSRAM offers alternative
solutions to cover a variety of requirements.
• Touch DIM®
(Single luminaires)
• MULTIeco
(Single and group offices)
• MULTI 3
(Strip lighting, hallways)
• Sensoren
(Sensors for stand-alone solutions)
TOUCH DIM®
Simple dimming without a controller
or dimmer switch: Touch DIM®.
OSRAM has come up with a cost-effective idea for providing simple lighting control with DALI® ECGs.
A new function has been added to DALI® ECGs: Touch DIM®.
The benefits of Touch DIM®:
• Standard switches can be used
• Radio version for flexible upgrade solutions
• Switch-on value can be saved in the ECG by double-clicking
• Suitable for fluorescent lamps, LV halogen lamps,
and LED modules
• Versions: Touch DIM®, Touch DIM® Remote,
Touch DIM® Sensor
Photo: © Waldmann
Dimming with line voltage.
With Touch DIM® it is now possible to dim and switch the
control gears directly with line voltage at the DALI® control
terminals. There is no longer any need for a separate
controller, as the ECG itself acts as the controller.
3
TOUCH DIM®
Touch DIM® – Dimming without
a dimmer switch.
Touch DIM® Sensor – for intelligent
single luminaires.
Applications:
• Simple manual dimming using conventional switches
• For individual offices or small conference rooms
Technical attributes:
• Maximum total control cable length 25 m
• Extendable by respectively 64 ECGs and a cable length of
300 m with the DALI® Repeater (cascadable system size)
• 2 mA control current per ECG
• Double-click to save switch-on value
Applications:
• Daylight-dependent control with presence function
and combination option for individual adjustment of
the lighting level
• For intelligent luminaires
Technical attributes:
• Compact dimensions for unobtrusive installation of luminaires
• A set point for daylight-dependent control can be stored
by double-clicking
• TOUCH DIM® Sensor available purely as a light sensor,
purely as a presence sensor with 4 different sensor elements,
or as a combination sensor for light and presence
• Stand-by consumption < 0.5 W
Optional: DALI® REPEATER
Dimmable
1…100 %
Dimmable
0,2…100 %
Dimmable
0,2…100 %
Light and
presence sensor
Up to 6
QTi DALI®
ECGs
Up to 6
HTi DALI® ECGs
Up to 6
OTi DALI®
ECGs
Products:
• QTi DALI® ECG for fluorescent lamps
• HTi DALI® ECG for LV halogen lamps
• OTi DALI® ECG for LED modules
Dimmable
1…100 %
Dimmable
0,2…100 %
Dimmable
0,2…100 %
Up to 4
QTi DALI®
ECGs
Up to 4
HTi DALI®
ECGs
Up to 4
OTi DALI®
ECGs
Up to 64
DALI®
ECGs
Products:
• QTi DALI®/HTi DALI®/OTi DALI® ECG
• Touch DIM® LS/PD LI luminaire installation sensor
TOUCH DIM® PRODUCT OVERVIEW
TOUCH DIM® LS/PD LI – Light
and presence sensor, luminaire
installation.
TOUCH DIM® LS LI – Light
sensor, luminaire installation.
•
•
•
•
•
•
•
•
•
•
Light and presence sensor
Can also operate purely as a presence sensor
Signal line length: max. 10 m
Power draw: max. 0.5 W
Delay time: 15 min
A set point for daylight-dependent control can
be stored by double-clicking
• Approx. 80° angle of detection, detection area
max. diameter 5 m, max. 5 m installation height
• Operated via standard switches
• Up to 4 QTi DALI® ECGs or 4 HTi DALI® ECGs
or 4 OTI DALI® ECGs can be connected
Light sensor
Signal line length: max. 10 m
Power draw: max. 0.5 W
A set point for daylight-dependent control can
be stored by double-clicking
• Operated via standard switches
• max. 4 m installation height
• Up to 4 QTi DALI® ECGs or 4 HTi DALI® ECGs
or 4 OTI DALI® ECGs can be connected
TOUCH DIM® PD LI 2P WOS – Presence sensor.
• Presence sensor with sensor head extension: 25 cm
• Different sensor elements available: spot type, 5 m type, 10 m type, type for
small movements
• Signal line length: max. 10 m
• Power draw: max. 0.5 W
• Delay time: 15 min
• Operated via standard switches
• Angle of detection, detection area, and max. installation height dependent
on sensor element selected
• Up to 4 QTi DALI® ECGs or 4 HTi DALI® ECGs or 4 OTI DALI® ECGs can be connected
5
TOUCH DIM® SYSTEM OVERVIEW
Touch DIM®
Radio switch
Remote control
TD WCU
TD RMC
Standard switch
User interface
**
Sensors
Sensor
SWITCH
RC
TD RC
TD LS LI
TD LS/PD LI
TD PD LI
2P WOS
Controller / Receiver
SOLAR
ECG / Ballast
Switching contact
*
HTM®
*
OT
QTi DALI®
HTi DALI®
OTi DALI® 75
Light sources
*
QT
6
Additional information on all radio products can be found in the brochure “Components”
* Non-dimmable QT, HT, and OT electronic control gears
** Battery-less radio standar
MULTIECO
Clever system for single and
group offices: MULTIeco.
The compact modular light management system MULTIeco offers varied daylight-dependent
and presence-dependent lighting control with minimal standby consumtion power.
The right solution for every need.
MULTIeco is extremely versatile. The controller is available
in a DALI® version, a 1…10 V version, and a switching
version. There are also six different light and presence
sensors for luminaire and ceiling installation. Possible
applications include offices, restrooms, and common areas.
The benefits of MULTIeco:
• Standby consumption < 0.5 W
• Luminaire integration or independent mounting
with ECO CI KIT
• Control of up to 20 ECGs
• Extremely compact dimensions
• Already meets the Swiss MINERGIE® Directive and
the EU Ecodesign Specifications planned for 2012
7
MULTIECO
DALI® MULTIeco in the office.
Energy-efficient light management for offices.
Simple operation and versatile functions make DALI®
MULTIeco an ideal light control system for office areas.
The perfect solution here is a daylight-dependent control
combined with presence detection. The 50 mm small mini
ceiling installation sensor for light and presence detection
Produkte:
• DALI® MULTIeco controller
• ECO CI KIT
• LS/PD MULTI 3 CI ceiling installation sensor
8
do not interfere with the ceiling look or the architecture of
the room. The controller can be installed in the intermediate
ceiling, in the small distributor, or directly in the luminaire.
The entire installation is extremely simple and can also be
done afterwards.
DALI® MULTIeco.
DIM MULTIeco.
• Up to 75 %* energy savings
compared to conventional solutions
• 14 different operating modes can
be set over DIP switches
MULTIeco.
• Up to 75 %* energy savings
compared to conventional solutions
• 14 different operating modes can
be set over DIP switches
DALI® MULTIeco
• Up to 45 %* energy savings
compared to conventional solutions
• 8 different operating modes can
be set over DIP switches
DIM MULTIeco
MULTIeco
1…10 V
Up to 10 ECGs
Up to 2 Sensors
Up to 10 ECGs
Up to 2 Sensors
Up to 20 ECGs**
Up to 2 Sensors
Connectable sensors (see also page 10)
LS/PD MULTI 3 FL
LS/PD MULTI 3
LS/PD MULTI 3 B
LS/PD MULTI 3 CI
LS/PD MULTI 3 A
LS/PD MULTI 3 A-W
* Compared to conventional systems: T8 lamp, conventional control gear, no sensors
** Taking into consideration the load capacity of the switching contact
9
MULTIECO PRODUCT OVERVIEW
10
LS/PD MULTI 3 – Light and presence
sensor, luminaire installation.
LS/PD MULTI 3 FL – Light and presence
sensor, luminaire installation, flat.
• Connection via modular 4p4c connector
• Connecting cable length: 2.1 m (detachable)
• Approx. 80° angle of detection, detection area max.
diameter 5 m, max. 4 m installation height
•
•
•
•
LS/PD MULTI 3 B – Light and presence
sensor, luminaire installation, moveable.
LS/PD MULTI 3 CI – Light and presence
sensor, ceiling installation, moveable.
•
•
•
•
•
•
•
•
Moveable sensor head
Connection via modular 4p4c connector
Connecting cable length: 2.1 m (permanently connected)
Approx. 80° angle of detection, detection area max.
diameter 5 m, max. 4 m installation height
Low-profile casing design
Connection via modular 4p4c connector
Connecting cable length: 2.1 m (permanently connected)
Approx. 80° angle of detection, detection area max.
diameter 5 m, max. 4 m installation height
Ceiling installation sensor with moveable sensor head
Connection via modular 4p4c connector/screw terminals
Surface mounting with SENSOR KIT
Approx. 80° angle of detection, detection area max.
diameter 5 m, max. 4 m installation height
LS/PD MULTI 3 A – Light and presence
sensor, luminaire installation, pluggable.
LS/PD MULTI 3 A-W – Light and
presence sensor, luminaire installation,
pluggable, white.
•
•
•
•
• Luminaire mounting possible via provided clip
• Connection via modular 4p4c connector
• High-temperature cable (125°), white,
connecting cable length: 2.1 m (detachable)
• Approx. 80° angle of detection, detection area max.
diameter 5 m, max. 4 m installation height
Luminaire mounting possible via optional clip
Connection via modular 4p4c connector
Connecting cable length: 2.1 m (detachable)
Approx. 80° angle of detection, detection area max.
diameter 5 m, max. 4 m installation height
DALI® MULTIeco
controller.
DIM MULTIeco
controller.
MULTIeco
controller.
• Suitable for daylight-dependent
control with presence function
• Standby consumption:
max. 0.5 W
• Integrated load contact for
disconnection
• Complies with MINERGIE® and
EU Ecodesign requirements
planned for 2012
• 14 different operating modes
can be set up via DIP switches
for daylight-dependent and
presence-dependent lighting
control
• Independent installation possible
with ECO CI KIT
• Up to 2 sensors can be
connected (compatible with all
MULTI 3 sensors)
• Up to 10 DALI® ECGs can be
connected
• Potential energy savings of
up to 75 %*
• Suitable for daylight-dependent
control with presence function
• Standby consumption:
max. 0.5 W
• Integrated load contact for
disconnection
• Complies with MINERGIE®
and EU Ecodesign requirements
planned for 2012
• 14 different operating modes
can be set up via DIP switches
for daylight-dependent and
presence-dependent lighting
control
• Independent installation possible
with ECO CI KIT
• Up to 2 sensors can be
connected (compatible with all
MULTI 3 sensors)
• Up to 10 1…10-V ECGs can be
connected
• Potential energy savings of
up to 75 %*
• Suitable for daylight-dependent
control with presence function
• Standby consumption:
max. 0.5 W
• Integrated load contact
• Complies with MINERGIE®
and EU Ecodesign requirements
planned for 2012
• 8 different operating modes
can be set up via DIP switches
for daylight-dependent and
presence-dependent lighting
control
• Independent installation possible
with ECO CI KIT
• Up to 2 sensors can be
connected (compatible with all
MULTI 3 sensors)
• Up to 20 ECGs can be
connected (if the contact load
capacity is exceeded, an external
power relay is required)
• Potential energy savings of
up to 45 %*
SENSOR KIT – Adapter for surface mounting.
ECO CI KIT – Installation kit.
• Adapter for surface mounting the EASY IR CI receiver element
• Can be used for separate mounting
of all OSRAM controllers measuring
118 × 30 × 21 mm (L × W × H)
* Compared to conventional systems: T8 lamp, conventional control gear, no sensors
11
MULTIECO SYSTEM OVERVIEW
MULTIeco
Standard switch
User interface
Sensors
Controller / Receiver
LS/PD
MULTI 3
LS/PD
MULTI 3 FL
LS/PD
MULTI 3 B
LS/PD
MULTI 3 CI
DALI® MULTIeco
LS/PD
MULTI 3 A
LS/PD
MULTI 3 A-W
DIM MULTIeco
MULTIeco
Switching
contact
ECG / Ballast
1...10 V DIM
HTi DALI®
OTi DALI® 75
QTi DIM
HT 1…10 V
**
OT DIM
*
QT
*
OT
Light sources
QTi DALI®
12
* Non-dimmable QT, HT, and OT electronic control gears
** Suitable power supply required
MULTI 3
Flexible and powerful:
Light group control with MULTI 3.
With its sophisticated functions and modular design, the MULTI 3 system offers versatile design options
for intelligent and cost-effective energy-saving solutions
New standards.
With a height of only 21 mm, the MULTI 3 controller now has
an even lower profile. It therefore complies with the standard
dimensions for T5 ECGs and is ideal for installation in
ceilings.
Remarkably unobtrusive.
The ceiling sensor in the MULTI 3 system has a diameter
of only 50 mm and can be installed inconspicuously almost
anywhere with no loss of functionality. Other light and
presence sensors are available to extend the system.
Simple setup.
The system can be installed very quickly and is immediately
ready for use.
Versatile modular system.
With only a few components you can create solutions with
MULTI 3 for luminaire groups and strip lighting in open-plan
offices.
13
MULTI 3
DALI® MULTI 3.
DIM MULTI 3.
• Up to 70 %* energy savings compared with
conventional solutions
• Choice of 10 different operating modes
• Up to 70 %* energy savings compared with
conventional solutions
• Choice of 10 different operating modes
DALI® MULTI 3
DIM MULTI 3
1…10 V
Up to 32 ECGs
Up to 4 sensors
Up to 32 ECGs
Up to 4 sensors
Connectable sensors (see also page 10)
LS/PD MULTI 3 FL
LS/PD MULTI 3
LS/PD MULTI 3 B
LS/PD MULTI 3 CI
LS/PD MULTI 3 A
LS/PD MULTI 3 A-W
* Compared to conventional systems: T8 lamp, conventional control gear, no sensors
14
DALI® MULTI 3 in strip lights.
DALI® MULTI 3 in open-plan offices.
Thanks to its modular design, DALI® MULTI 3
can also be used in large areas, such as group and
open-plan offices.
Up to four lighting groups can be synchronized with one
another, so that up to 16 light and presence sensors can
capture a larger area. Just like the smaller solutions for
individual offices, this entire light management system can
be unobtrusively integrated into the existing architecture
of the room.
Up to 4
sensors
Up to 32
DALI® ECGs
Up to 4
sensors
Up to 32
DALI® ECGs
Up to 4
sensors
Up to 32
DALI® ECGs
Up to 4 DALI® MULTI 3 controllers
o
can be
synchronized for centralized presence detection
Up to 4
sensors
Up to 32
DALI® ECGs
Up to 4
sensors
Up to 32
DALI® ECGs
Up to 4
sensors
Up to 32
DALI® ECGs
Intelligent energy-efficient luminaires and luminaire
groups.
Daylight-dependent control combined with a presence
function can also be provided for strip lights. DALI® MULTI 3
allows new freedom in luminaire design: with their minimal
dimensions, the sensors are easy to integrate while retaining
maximum functionality. The sensors can simply be
connected in parallel to enlarge the area.
Strip light 1
Strip light 2
Strip light 3
Products:
• DALI® MULTI 3 controller
• QTi DALI® ECG
• LS/PD MULTI 3 A-W luminaire installation sensor
• Optional: Y-connector
Group A
Group B
Group C
Products:
• DALI® MULTI 3 controller
• LMS CI BOX ceiling installation box
• LS/PD MULTI 3 CI ceiling installation sensor
• Y-connector
15
MULTI 3 PRODUCT OVERVIEW
DALI® MULTI 3 controller.
DIM MULTI 3 controller.
• Controller for up to 32 DALI® ECGs for daylightdependent control with presence function
• Different operating modes depending on the application
• 21 mm height for simple installation in luminaires;
ceiling installation with LMS CI Box
• Sensor connection via modular 4p4c socket
• Up to 70 %* energy savings
• Controller for up to 32 DALI® 1…10-V ECGs for
daylight-dependent control with presence function
• Different operating modes depending on the application
• 21 mm height for simple installation in luminaires;
ceiling installation with LMS CI Box
• Sensor connection via modular 4p4c socket
• Up to 70 %* energy savings
Y-CONNECTOR.
Y-CONNECTOR SCREW – Y-Connector
with screw terminals.
• Y-connector for system expansion with 2 ready-made
modular 4p4c cables (2 m)
• Allows the detection range to be expanded by
connecting additional sensors
• Allows synchronization of multiple MULTI 3 or MULTIeco
controllers for central presence detection
• 2 ready-made modular 4p4c cables (2 m) included
LMS CI BOX – Ceiling installation box for controller.
• LMS CI Box for ceiling mounting of the radio receiver and also for MULTI 3 controllers
SENSOR KIT – Adapter for surface mounting.
• Adapter for surface mounting the EASY IR CI receiver element
* Compared to conventional systems: T8 lamp, conventional control gear, no sensors
16
MULTI 3 SYSTEM OVERVIEW
MULTI 3
Standard switch
User interface
Sensors
Controller / Receiver
LS/PD
MULTI 3
LS/PD
MULTI 3 FL
LS/PD
MULTI 3 B
LS/PD
MULTI 3 CI
LS/PD
MULTI 3 A
DALI® MULTI 3
LS/PD
MULTI 3 A-W
DIM MULTI 3
ECG / Ballast
1...10 V DIM
HTi DALI®
OTi DALI® 75
QTi DIM
HT 1…10 V
*
OT DIM
Light sources
QTi DALI®
* Suitable power supply required
17
STAND-ALONE SENSORS
Stand-alone sensors for autonomous use
as starting point for energy-saving lighting.
Thanks to their ease of installation, stand-alone sensors offer especially cost-effective energy saving
solutions and are ideal for retrofitting.
Modern, easy-to-install sensors for a wide variety of
applications
OSRAM offers a large number of innovative sensors for
indoor and outdoor use. They provide the basis for energy
savings of up to 70 %* and are particularly easy to install
or retrofit.
* Compared to conventional systems: T8 lamp, conventional control gear, no sensors
18
•
•
•
•
•
•
•
•
•
Offices: single and group workplaces
Waiting rooms and conference rooms
Hallways and foyers
Stairwells
Retail and commercial areas
Restrooms and washrooms
Factories and warehouses
Single luminaires
Strip lighting
STAND-ALONE SENSORS PRODUCT OVERVIEW
Light and presence sensors.
SOLAR light and presence sensor.
DUO light and presence sensor.
• Suitable for such areas as hallways, waiting rooms, and wash rooms
• Choice of different operating modes: daylight detection only, presence detection only,
daylight and presence detection
• All the functions can be selected on the rotary switch on the front of the casing
and DIP switches in the casing
• Minimal installation costs due to surface mounting or simple clip-on installation for T5
(diameter 16 mm) or T8 (diameter 26 mm) fluorescent lamps
• Up to 30 ECGs can be connected
• Adjustable switch-off delay: 1 min to 60 min
• Standby consumption: max. 0.7 W
• Load capacity of switching contact: 5 A ohmic load
• Multiple sensors can be networked
• Approx. 110° detection angle, detection area: max. diameter 12 m, max. installation height 5 m
• Potential energy savings of up to 45 %*
DIM MULTI light and presence sensor.
• Suitable for such areas as individual and group offices
• 1…10-V sensor for daylight-dependent and presence-dependent control
• For ceiling surface mounting and simple clip-on installation for T5 (diameter 16 mm) or T8
(diameter 26 mm) fluorescent lamps
• Choice of different operating modes: daylight detection only, daylight and presence detection
• Approx. 110° detection angle, detection area: max. diameter 12 m, max. installation height 5 m
• All the functions can be selected on the rotary switch and pushbutton on the front of the casing
• Up to 30 ECGs can be connected
• Adjustable switch-off delay: 1 to 30 min + 10 min switch-off time
• Compensates for 100 % of the incoming daylight
• Load capacity of switching contact: 5 A ohmic load
• Multiple sensors can be networked
• Potential energy savings of up to 70 %*
* Compared to conventional systems: T8 lamp, conventional control gear, no sensors
19
STAND-ALONE SENSORS PRODUCT OVERVIEW
Light and motion sensors.
WALL SWITCH light and motion sensor with
flush-mount relay insert.
• Suitable for touch-free switching
(e. g. hallways, stairwells)
• Choice of different operating modes: stairwell,
time switch, constant light
• Can be combined with conventional light switches
• Can be installed in standard wall flush-mount boxes
• Manual constant light can be activated
• Up to 14 ECGs can be connected
• Delay time can be adjusted to any length
up to 30 minutes
• Multiple sensors can be networked
• Approx. 180° detection angle, detection area max.
diameter 8 m, max. installation height 2 m
• Potential energy savings of up to 45 %*
OUTDOOR light and motion sensor.
• Suitable for outdoor applications
• Choice of different operating modes:
motion detection only, daylight and motion detection
• Adjustable switch-off delay: 5 seconds to 30 minutes
• Up to 14 ECGs can be connected
• Manual control with optional switch or pushbutton
• Swivel arm for wall or ceiling mounting
• Approx. 120° detection angle, detection area
max. diameter 16 m, max. installation height 4 m
• Potential energy savings of up to 45 %*
Light sensors.
DIM PICO light sensor.
• Suitable for individual luminaires in single and small
group offices
• 1…10-V mini light sensor for simple retrofitting
• Direct connection to the 1…10-V interface
• Simple clip-on installation for T5 (diameter 16 mm) or
T8 (diameter 26 mm) fluorescent lamps
• Simple setting of the set point using a potentiometer
• Load capacity of the control output: max. 10 1…10-V
ECGs or max. 6 mA
• Cable length: 700 mm
• Compensates for 50 % of the incoming daylight
• Approx. 50° detection angle, max. installation height 5 m
• Potential energy savings of up to 30 %*
DIM MICO light sensor.
• Suitable for strip lights in individual and group offices
• 1…10-V mini light sensor for simple retrofitting
• Direct connection to the 1…10-V interface
• Simple clip-on installation for T5 (diameter 16 mm) or
T8 (diameter 26 mm) fluorescent lamps
• Simple setting of the set point using a potentiometer
• Load capacity of the control output: max. 10 1…10-V
ECGs or max. 16 signal amplifiers
• Cable length: 700 mm
• Compensates for 100 % of the incoming daylight
• Approx. 80° detection angle,
max. installation height 8 m
• Potential energy savings of up to 40 %*
Motion sensors.
HIGH BAY motion sensor.
• Suitable for great installation heights
(factories, warehouses, sports facilities)
• 3 m to 10 m: detection of motion by people
• 3 m to 13 m: detection of vehicle movement
(e.g. fork lift truck)
• Adjustable switch-off delay: 30 seconds to 20 minutes
• Surface mounting for low installation costs
• Up to 15 ECGs can be connected
• Standby consumption: max. 0.5 W
• Can be surface-mounted on ceilings using a
mounting adapter
• Approx. 100° detection angle, detection area
max. diameter 18 m, max. installation height 13 m
• Potential energy savings of up to 35 %*
VISION motion sensor.
• Suitable for large areas, e. g. open-plan offices,
hallways, and storage rooms
• Adjustable switch-off delay: 30 seconds to 20 minutes
• Surface mounting for low installation costs
• Up to 15 ECGs can be connected
• Standby consumption: max. 0.5 W
• Can be surface-mounted on ceilings using
a mounting adapter
• Approx. 140° detection angle, detection area
max. diameter 21 m, max. installation height 4.5 m
• Potential energy savings of up to 35 %*
* Compared to conventional systems: T8 lamp, conventional control gear, no sensors
21
STAND-ALONE SENSORS SYSTEM OVERVIEW
Stand-alone sensors
Sensors
Sensors
HIGH
BAY
WALL
SWITCH
VISION
OUTDOOR
DUO
DIM
MULTI
DIM
PICO
DIM
MICO
Controller / Receiver
User interface
Switch
1...10 V DIM
ECG / Ballast
Switching contact
*
HTM®
*
OT
**
QTi DIM
HT 1…10 V
OT DIM
Light sources
*
QT
22
* Non-dimmable QT, HT, and OT electronic control gears ** Suitable power supply required
ORDER OVERVIEW
Touch DIM®
Graphic
Technical drawing
h
w
l
Order description
Product number
Dimensions
Light and presence sensor,
luminaire installation
Touch DIM® LS/PD LI
4008321023025
63 × 29 × 21 mm
(L × W × H)
Light sensor, luminaire
installation
Touch DIM® LS LI
4008321023087
63 × 29 × 21 mm
(L × W × H)
Presence sensor
TD PD LI 2P WOS
4008321532954
63 × 29 × 21 mm
(L × W × H)
Product description
Order description
Product number
Dimensions
Controller
DALI® MULTIeco
4008321371300
118 × 30 × 21 mm
(L × W × H)
Controller
MULTIeco
4008321405302
118 × 30 × 21 mm
(L × W × H)
Controller
DIM MULTIeco
4008321507273
118 × 30 × 21 mm
(L × W × H)
Y-connector
Y-CONNECTOR
4050300803135
34 × 18 × 16 mm
(L × W × H)
Y-connector incl. screw
terminals
Y-CONNECTOR SCREW
4008321916686
40 × 20 × 16 mm
(L × W × H)
Installation kit
ECO CI KIT
4008321392091
–––––
Adapter for surface mounting
SENSOR KIT
4008321916662
80 × 25 mm
(Ø × H)
h
w
l
Product description
MULTIeco
Graphic
Technical drawing
w
l
h
l
w
h
l
h
w
–––––
h
Ø
23
ORDER OVERVIEW
Sensors for MULTIeco /MULTI 3
Graphic
Technical drawing
l
h
w
w
l
Order description
Product number
Dimensions
Light and presence sensor,
luminaire installation,
standard
LS/PD MULTI 3
4050300802138
55 × 21 × 25 mm
(L × W × H)
Light and presence sensor,
luminaire installation, flat
LS/PD MULTI 3 FL
4050300047342
35 × 21 × 12 mm
(L × W × H)
Light and presence sensor,
luminaire installation,
moveable
LS/PD MULTI 3 B
4050300803081
48 × 30 × 25 mm
(L × W × H)
Light and presence sensor,
ceiling installation, moveable
LS/PD MULTI 3 CI
4008321916648
50 × 25 mm
(Ø × H)
Light and presence sensor,
luminaire installation/
mounting
LS/PD MULTI 3 A
4008321653598
38 × 20 × 22 mm
(L × W × H)
Light and presence sensor,
luminaire installation/
mounting white
LS/PD MULTI 3 A-W
4008321653611
38 × 20 × 22 mm
(L × W × H)
Product description
Order description
Product number
Dimensions
h
Product description
h
w
l
ø
h
l
h
MULTI 3
Graphic
Technical drawing
®
Controller
DALI MULTI 3
4050300802084
189 × 30 × 21 mm
(L × W × H)
Controller
DIM MULTI 3
4050300802107
189 × 30 × 21 mm
(L × W × H)
Y-connector
Y-CONNECTOR
4050300803135
34 × 18 × 16 mm
(L × W × H)
Y-connector incl. screw
terminals
Y-CONNECTOR SCREW
4008321916686
40 × 20 × 16 mm
(L × W × H)
Installation kit
LMS CI BOX
4008321083692
261 × 71/35 × 27 mm
(L × W × H)
Adapter for surface mounting
SENSOR KIT
4008321916662
80 × 25 mm
(Ø × H)
w
l
h
l
w
h
l
h
w
w
h
l
h
Ø
24
ORDER OVERVIEW
Stand-alone sensors
Technical drawing
Product description
Order description
Product number
Dimensions
Light and presence sensor
SOLAR
4008321385628
108 × 108 × 26 mm
(L × W × H)
Light and presence sensor
DUO
4008321496355
71 × 58 × 47 mm
(L × W × H)
Light and presence sensor
DIM MULTI
4050300554471
58 × 71 × 48 mm
(L × W × H)
Light and motion sensor
WALL SWITCH
4008321467386
82 × 82 × 26 mm
(L × W × H)
Light and motion sensor
OUTDOOR
4008321957061
180 × 86 × 74 mm
(L × W × H)
Motion sensor
HIGH BAY
4008321410078
116 × 116 × 39 mm
(L × W × H)
Motion sensor
VISION
4008321957047
116 × 116 × 40 mm
(L × W × H)
Light sensor
DIM PICO
4050300554457
21 × 21 × 31 mm
(L × W × H)
Light sensor
DIM MICO
4050300464411
59 × 28 × 40 mm
(L × W × H)
1-channel radio receiver
SWITCH RC
4008321385642
45 × 37 × 23 mm
(L × W × H)
Adapter for surface mounting
for HIGH BAY and VISION
MOUNTING ADAPTER
4008321480798
116 × 19 mm
(Ø × H)
w
w
w
h
Graphic
l
w
w
l
w
h
w
w
w
25
SYSTEM GUARANTEE / INFO
System guarantee.
Only from OSRAM: System+ Guarante
ee for unique security and quality.
OSRAM offers an extensive three-stage guarantee
g
for light man
nagement systems and
ECG/lamp systems from OSRAM. All the details on the relevant products, registration
and the guarantee requirements can be fo
ound at: www.osram.c
com/system-guarantee
Ambience
➔ EASY Color and white light control for shop and hospitality
Scenes
➔ For multifunctional management of lighting groups and lighting scenes
Components
➔ For expanding, connecting or installing light management products
Light Source Control Gears
➔ For safe, efficient and reliable lamp/luminaire operation
LMS from OSRAM: LMS folder.
Compilation of product brochures on every LMS topic, including
a poster, an application matrix and a CD-ROM, bundled in a folder.
1FZW001GB 10/11 VO OSRAM CRM M
MK AB
Energy saving
➔ For energy-saving daylight-dependent and presence-dependent lighting
Subject to change without notice. OSRAM does not accept liability for errors, changes and omissions.
The perfect solution: the OSRAM LMS product portfolio.
To reflect the principal application requirements, OSRAM’s LMS product portfolio is structured in the following
five categories: