TDK_CXA-0463.pdf

MESSRS :
PRODUCT DRAWING
CUSTOMER'S PRODUCT NAME:
TDK PRODUCT NAME:
T
DC/AC INVERTER UNIT
CXA-0463
A
T
N
E
E
V
I
T
TDK Corporation
Corporate Headquarters
13-1,Nihonbashi 1-chome,Chuo-ku,
Tokyo 103, JAPAN
Telephone : 03-3278-5111
2-15-7,Higashi-Ohwada,Ichikawa-shi,
Chiba,272-8558 JAPAN
Telephone : 047-378-9671
Fax : 047-378-9673
PREPARED BY
APPROVED BY
AUTHORIZED BY
Dec.15.2005
H.Mitsumoto
Dec.15.2005
E.Takahashi
Dec.15.2005
K.Hanabusa
DWG.No.
CTR-2052-X
Precautionary Notes Regarding the Use of This Inverter
When using this product, give due consideration to the precautionary notes described below and ensure
a safe design. Inappropriate use may result in electric shock, injury or fire.
Warning
● This product is subject to high voltage. Do not touch it while the power is on.
Failing to do so may result in electric shock.
Caution
● This product is designed for the lighting of a Cold Cathode Fluorescent Lamp.
Do not use it with any other load.
● Store this product under the conditions defined in the specification document.
● Do not store this product in an environment where dust, dirt or corrosive gas(salt,acid,base, etc.) is present.
● This product is subject to high voltage. If there is a possibility that the user may touch the product,
provide a proper indication in order to draw the user's attention.
● This product is designed for use with general electronic equipment.
If it is to be used with medical equipment that directly affects human life or for the control of
transportation equipment to which passengers entrust their lives, provide thorough fail-safe measures.
● Avoid using this product under high temperatures or high humidity or in an environment in which
dust, dirt or any corrosive gas (salt,acid,base, etc .) is present.
Also,be careful not to allow the formation of dew condensation. It may result in damage or electric shock.
● If the product does not have a built-in protective circuit (circuit breaker, fuse, etc.),
it is recommended that a fuse be used at the input stage to prevent the generation of
smoke or fire in the event of a malfunction.
Even when the product has a built-in protective circuit (circuit breaker, fuse, etc.),
the circuit may not function properly due to inappropriate operating conditions or power-supply capacity.
It is recommended that an appropriate protective circuit (circuit breaker, fuse, etc.)
be provided separately from the built-in circuit.
● Use the product only within the specified input voltage, output power, output voltage
and operating temperature ranges. Exceeding these values may result in damage, etc.
● Provide a measure for the prevention of surge voltage due to lightning, etc.
Abnormal voltage may result in damage, etc.
● To prevent problems arising from short-circuiting of the high-voltage section,
provide appropriate measures to prevent the entry of foreign substances following installation.
● This product is not designed to provide resistance to radiation.
● Ripples could be superimposed on the voltage and the current in the input source connected to the inverter ,
depending on the impedance in the input source, wiring, etc.
When you select an input source, please check waveforms, etc on the final set.
T
A
T
N
E
E
V
I
T
Handling Precautions
● This product uses thin wires. Observe the following precautions and handle it with care so
as not to cause wire breakage. Broken wire may result in damage, etc.
・Do not stack multiple products on top of one another.
・Do not allow the product to come in contact with tools, etc.
● Do not apply excessive stress during installation.
It may cause chipping and cracking,resulting in damage, etc.
● Provide a clearance of 2 mm or more between the high-voltag e section of this product and
the frame body on which the product is installed and also the conductor section (pattern , pad etc. ).
● Please do not use the product, when dropping it, since there is a possibility of the parts damage.
Please confirm abnormality is not found in the product enough when using it by any chance.
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0463
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2052-X
1
<The specifications may be changed without an y notice.>
・The specifications may be changed without any notice.
・When placing orders,
please confirm "Specifications" or "Product Drawing" through TDK sales or distributors.
[1] Outline
①
③
(1)
(0.5)
CN24
CN1
(11)
CAUTION
HIGH
VOLTAGE
CN21
CN1-8
12±0.5
4±0.3
CN2
CN1-1
14±0.3
22±0.5
②
2-φ3.5±0.2
(9.4)
1-1. Outline
84±0.3
110±0.5
E
V
I
T
8.5MAX.
SILICONE
A
T
N
E
a:60mm
(a:High Voltage generation area)
CXA-0463
541 5
MADE IN CHINA
T
Label (Examlpe)
TDK part No, Date code, Country of origin
*Please secure the air clearance of 2mm or more from the high voltage generation area up and down and right and left.
Please refer to Note1-3. for details.
Unit:mm
Weight:22g
No.
Part Description
Material
QU
REMARK
(i)
PCB
Conposite (CEM-3)
1
UL94V-0 t=1.0
(ii)
Input Connector CN1
53261-0871
1
(MOLEX)
(iii)
Output Connector CN2
SM03(7-D1)B-BHS-1-TB(LF)(SN)
1
JST
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0463
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2052-X
2
<The specifications may be changed without an y notice.>
Note1-2. Marking of TDK part No, Date code, Country of origin.
1) TDK part No., Date code, Country of origin, is marked on the trans former.
2)Date code example. (ex.Apr. 15. 2005)
5
4
1
5
Two digits of production day.
One digit of production month. (Oct. : X, Nov. : Y, Dec. : Z).
Last digit of production y ear.
3) Country of origin code example. (ex. MADE IN JAPAN. MADE IN CHINA).
1-2. Connector Configuration
Input side CN1
Pin No.
CN1-1
CN1-2
CN1-3
CN1-4
Output side CN2
Symbol
Rating
Notes
Vin
10.8~13.2V
Input Voltage
GND
0V
GND
CN1-5
Vrmt
-1∼Vin+1V
CN1-6
Rbr1/Vbr
0~2.5V
/0~50kW
CN1-7
Rbr2/Vbr2
GND/0∼50kW
CN1-8
Vst
(Output)
0V/5V
Note1-3.
A
T
N
E
0~0.4V:OFF
2.5~Vin V:ON
E
V
I
T
Pin No.
Symbol
Rating
Notes
CN2-1
VHIGH1
370Vrms
Output 1
CN2-2
VHIGH2
370Vrms
Output 2
CN2-3
N.C.
CN2-4
VLOW
N.C.
(2V)
Output 1,2Return
VR1/Control
T
GND/VR2
The warning output
5V in avnormal
circumstances
Please use minimum of 2mm clearance (all directions) between inverter high voltage ar ea and any conductors.
Please refer to mechanical drawing for marking of high voltage area.
Note1-4.
Don't connect the output Vlow(CN2-4) terminal and the input GND(CN1-3,4).
Note1-5.
For proper operation of circuit protection (fuse or IC protector),Please use minimum of 2A capacity
for input power supply.
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0463
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2052-X
3
<The specifications may be changed without an y notice.>
[2] Absolute maximum ratings
Item
Symbol
Specification
Vin
0~14
Input Voltage
Vrmt
-1~Vin+1
Vbr
0~14
Load Resistanve
RL1/2
TBD
kΩ
Operating Temp. range
Ta
-30~+80
°C
Storage Temp. range
Ts
-35~85
°C
Humidity range
RH
95
%RH
T
Unit
Notes
V
A
T
N
E
A maximum wet ball temperature is 39°C
No dew.
E
V
I
T
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0463
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2052-X
4
<The specifications may be changed without an y notice.>
[3] Electrical specifications
Conditions
Item
Symbol
Output Current
(Brightness
max.)
Specifications
Vrmt(V)
lo1/2
12±1.2
5±0.25
0Ω / 0V
0∼60
TBD
TBD
5.5
6.0
6.5
Output Current
(Brightness min.)
lo1/2
12±1.2
5±0.25
50kΩ / 2.5V
0∼60
TBD
TBD
1.8
2.5
3.2
Input Current 1
lin1
12±1.2
5±0.25
0Ω / 0V
0∼60
-
0.62
1.0
A DC
Input Current 2
lin2
12±1.2
0
0Ω/ 0V
0∼60
-
0
1
mA
Input Current3
*3-1
lin2
12±1.2
5±0.25
0Ω/ 0V
0∼60
-
10
30
mA
Frequency
F1
12±1.2
5±0.25
0Ω/ 0V
0∼60
45
50
55
kHz
Frequency
(Duty)
F2
12±1.2
5±0.25
50kΩ / 2.5V
0∼6 0
23 0
25 5
28 0
Hz
Open Circuit
Voltage
Vopen
12±1.2
5±0.25
0Ω/ 0V
0∼6 0
130 0
150 0
170 0
kVrms
12±1.2
5±0.25
0Ω/ 0V
0∼6 0
4.5
5.1
5.5
12±1.2
5±0.25
0Ω/ 0V
0∼6 0
4.5
5.1
5.5
12±1.2
5±0.25
0Ω/ 0V
0∼6 0
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
-
0
0.5
Warning Signal
*3-2
Ta(°C)
RL1(kΩ)
RL2(kΩ)
MIN.
TYP.
MAX.
Unit
Vin(V)
Rbr(kΩ )/
Vbr(V)
mArms
Vs t
A
T
N
E
E
V
I
T
V
*3-1.When the inverter detects open circuit all of the lam ps
for more than 3 seconds it will sh ut down.
*3-2.In test circuit[4] ,when any switches open,
the warning signal will be activated (+5V).
T
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0463
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2052-X
5
<The specifications may be changed without an y notice.>
[4] Test circuit
F
Vin
10.8∼13.2V
A Iin
−
1000:1
PROBE
F
CN1-1
CN1-2
V
−
a
Vrmt
0/5V
Vbr
0∼2.5V
V
−
SW3
CN2-1
CN1-3
CN1-4
b
SW1
C10
Q6
RL1
RL2
C25
Io2
a
V
−
SW4
CN2-2
T1
CN1-5
Vopen V
∼
A
∼
Io1
A
∼
CN1-6
SW2
b
CN2-4
SW5
CN1-7
Rbr
0∼50kΩ
CN1-8
Vst
V
−
Note4-1. SW1(ON/OFF) Operation is as fol lowing;
SW1
Operation of unit
a
Operation
b
Non operation
E
V
I
T
RL1,2:Load resistance (7Ω MIN.)
Note4-2. SW2(ON/OFF) Operation is as fol lowing;
A
T
N
E
SW2
Operation of unit
a
Voltage dimming
Vbr=0~2.5V
b
Variable resistance dimming
VR=0~50kW
Note4-3. SW3∼5(ON/OFF) Operation is as follow ing;
T
SW3∼5
Operation of unit
Open
Operation (5V out put)
Close
Non operation(0V out put)
Note4-4.Test Equipments
V
Digital Multiple Meter(ADVANTESTR6451A or equivalent)
A
DC Current Meter(ADVANTEST R6451A or equivalent)
F
Frequency Countor(ADVANTEST R6452A or equivalent)
V
~
True RMS Meter(KEITHLEY 2001 or equivalent.)
A
~
High Frequency Current Meter(KEITHLEY 2001 or equivalent)
1000:1
High Voltage Probe(Tektronix P3000 or equivalent)
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0463
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2052-X
6
<The specifications may be changed without an y notice.>
Note4-5.
Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the reading at the
output connector would be less than the actual value.
Note4-6.
If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily specially at lo wer
ambient temperature. Please review mounting instruction to avoid any abnormal operation due to coupling/leakage
capacitance of inverter high voltage area to any surrounding conductor.
[5] Reliability test
Following test items are assured.
Item
Condition
Low Temp.Non
operational
-30°C 500h
Low Temp.operational
-30°C 500h
Load cond.:TYP
High Temp.Non
operational
85°C 500h
High Temp.operational
80°C 500h
Load cond.:TYP
Heat shock
-20°C 75°C
30min.Each 100 Cycles
Humidity
(Non operational)
60°C 90~95%RH 500h
T
Judgement
A
T
N
E
E
V
I
T
Electrical and apperrance should be in the
spec.
10~57Hz Amplitude
58~500Hz 1G
Sweep:11min
60min each axis X,Y,Z
Vibration
100G 11ms Harf-sine pulse
1 time each axis ±X,Y,Z
Shock
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0463
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2052-X
7
<The specifications may be changed without an y notice.>
[6] Packing and Marking
A shipping box is packaged to avoid from damage. Fol lowing items are printed on the box.
6-1.
6-2.
6-3.
6-4.
6-5.
6-6.
CXA-0463
TDK part No.
TDK
Manufacture
Customer part No.
QTY.
Inspection No.
Country of origin
Anti static bag
10pcs / box
A
T
N
E
E
V
I
T
Marking
TDK Part No.
Manufacture
Customer Part No.
QTY.
Inspection No.
Countory of origin
10pcs/Inner box × 10
=100pcs/Outer carton
Inner box
(237mm:L)×(223mm:W)×(40mm:H)
T
Marking
TDK Part No.
Manufacture
Customer Part No.
QTY.
Inspection No.
Countory of origin
Outer carton
(500mm:L)×(244mm:W)×(234mm:H)
[7] Others
7-1. Test cond.
A normal test condition :Temperature (20±15°C), Humidity (65±20%RH).
7-2. Std warrantry
One year after shipment.This covers any defects in material or workmanship.
Defective units will be replaces at no charge.
7-3. Others
TDK and customer are to discuss changes,problems, and modifica tions and etc, when needed.
PRODUCT NAME or MODEL,TITLE
DC-AC INVERTER UNIT CXA-0463
TDK CORPORATION
NAME OF DRAWING
DRAWING No.
PAGE
PRODUCT DRAWING
CTR-2052-X
8
<The specifications may be changed without an y notice.>