DC-AC INVERTER UNIT
PS-DA0211-05(S) (11 W DUAL OUTPUTS)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
APPLICABLE LCD:
6.4 to 15 inches double lamp type
Lamp Voltage 650 Vrms
Lamp Current 2 x 5.5 mArms
Lamp Start Up Voltage 1.500 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
140 x 24 x 14 mm
Q2
C3
C6
R21
C8
R15
R18
C12
R4
T1
CN3
CAUTION
Q11
R8
L2
? ?
R2
C4
C5
C10
R9
Q12
R20
R3
? ?
R7
!
R5
?
CAUTION
CN2
1
CN1
F1
D4
D3
DA0211-
D1
CN1
D2
1
Q1
REV:1.0
A0
!
T2
R6
CN3
3.2Ø X2
PIN 1
PIN 1
C2
?
LxWxH
R1
DIMENSIONS :
-10°C ~ +60°C
-40°C ~ +85°C
95 %RH max
1
C1
CN2
L1
Unit : mm
Weight :39,8 (g) typ.
PIN 1
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Description
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
Note
t=1m m
JST or equal
3
Connector CN2 + CN3
2
SM02(8.0)B-BHS-1-TB
JST or equal
Input side CN1:
Output side CN2:
Pin No.
CN 1-1
CN 1-2
CN 1-3
CN 1-4
Symbols
Vin
GND
Vbr
GND
Ratings
10.8 ~ 13.2 Vdc
CN 1-5
Vrm t
0 ~ 0.4 = OFF / 4.5 ~ Vin = ON
Pin No.
CN 2-1
Symbols
Vhigh
Ratings
650 Vrms (5.5 mArms)
CN 2-2
Vlow
(GND)
0 ~ 4.2 Vdc
Output side CN3:
Pin No.
CN 3-1
Symbols
Vhigh
Ratings
650 Vrms (5.5 mArms)
CN 3-2
Vlow
(GND)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.2.1, 10th March 2011
DC-AC INVERTER UNIT
PS-DA0211-05(S) (11 W DUAL OUTPUTS)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No load Shutdown
Iout
Iout
Iin
F
Vopen
Tsd
Note 1 :
Note 2:
Conditions
Vrmt
Vin (V)
Tu (°C)
(V)
12±1.2 5±0.25 0 ~ +50
12±0.6 5±0.25 0 ~ +50
12±1.2 5±0.25 0 ~ +50
12±1.2 5±0.25 0 ~ +50
11.4
5±0.25 0 ~ +50
12±1.2 5±0.25 0 ~ +50
Specification
Min.
Typ.
Max.
5.0
2.0
44.5
1.300
1.0
5.5
2.5
0.84
52
1.500
-
6.0
3.0
1.23
59.5
1.700
-
Unit
Note
mArms
mArms
Adc
kHz
Vrms
sec
Vbr = 0 Vdc
Vbr = 4.2 Vdc
wit hout load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Dimming function: Brightness max. @ Vbr = 0 Vdc, Brightness min. @ Vbr. = 4,2 Vdc.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.2.1, 10th March 2011