PS_PS-DA0253-124-E-B.pdf

DC-AC INVERTER UNIT
PS-DA0253-124(S) (8 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for Sharp: LQ104S1DG21 and LQ121S1LW01
APPLICABLE LCD:
10 to 15 inches dual lamp type
Lamp Voltage 466 Vrms
Lamp Current 2 x 6.0 mArms
Lamp Start Up Voltage 1.700 Vrms (Vin : 12 Vdc)
FEATURES :
Current Feedback Circuit
High Efficiency
Low noise with voltage resonant circuit
Regulated output current
RoHS compliant (S)
Coating on request
Wide temperature range
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-30°C ~ +80°C
-30°C ~ +85°C
95 %RH max
153 x 22 x 10 mm
Pin1
Pin1
Pin1
Unit : mm
Weight :20 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Description
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
53261-0790
Note
t=1.6mm
Molex or equal
3
Connector CN2 ~ CN3
2
SM02(8.0)B-BHS-1-TB
JST or equal
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.1, 12th January 2010
DC-AC INVERTER UNIT
PS-DA0253-124(S) (8 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
Input side CN1:
Pin No.
CN 1-1+2
CN 1-3+4
CN 1-5
CN 1-6
CN 1-7
Output side CN2 ~ CN3
Symbols
Ratings
Vin
10.8 ~ 13.2 Vdc
GND
Vrmt
0 ~ 0.4 = OFF / 2.5 ~ Vin = ON
Vbr
0 ~ 2.5 Vdc
N.C.
Pin No.
CN 2/3-1
CN 2/3-2
Symbols
Vhigh
N.C.
Ratings
446 Vrms (6.0 mArms)
-
CN 2/3-3
Vlow
(GND)
-
ELECTRICAL CHARACTERISTICS :
Conditions
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
No Load Shutdown
Iout
Iout
Iin
F
Vopen
Tsd
Note 1 :
Note 2 :
Specification
Vin (V)
Vbr (V)
Tu (°C)
Min.
Typ.
Max.
12±1.2
12±0.6
12±1.2
12±1.2
11.4
12±1.2
0.0
2.5
0.0
0.0
0.0
0.0
-30 ~ +80
-30 ~ +80
-30 ~ +80
-30 ~ +80
-30 ~ +80
-30 ~ +80
5.5
1.5
32.5
1.500
1.0
6.0
2.0
0.75
40
1.700
-
6.5
2.5
1.0
47.5
-
Unit
Note
mArms
mArms
Adc
kHz
Vrms
sec
Duty 100%
without load
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
Open circuit on all lamps for more than 3 seconds, will shut the inverter down.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.1, 12th January 2010