PS_PS-M06D12S4-NJ4L-124.pdf

DC-AC INVERTER UNIT
PS-M06D12S4-NJ4L-124(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for Optrex: T-51512J121FW-A-AFN
APPLICABLE LCD:
6.4 to 12 inches double lamp type
Lamp Voltage 540 Vrms
Lamp Current 6 mArms
Lamp Start Up Voltage 1.300 Vrms (Vin : 12 Vdc)
FEATURES :
RoHS compliant (S)
Remote ON/OFF
Ext. PWM
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
0°C ~ +60°C
-20°C ~ +85°C
95 %RH max
105 x 22,5 x 10mm
Unit : mm
Weight :20 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Pin No.
CN 1-1
CN 1-2
CN 1-3
CN 1-4
CN 1-5
Part Description
PCB
Connector CN1
Connector CN2
Symbols
Vin
GND
Ext. PWM
N.C.
Vrm t
Qty.
1
1
1
Material
UL94V-0 (CEM-3)
S5B-PH-SM3
SM04(4.0)B-BHS
Ratings
12 Vdc
0Vdc
0~5 Vdc (L activ)
Output side CN2:
Pin No. Symbols
CN 2-1+2 VHIGH1
N.C.
CN 2-3
VLOW
CN 2-4
Note
t=1.0m m
JST or equal
JST or equal
Ratings
540 Vrm s ( 6m Arm s )
0 Vdc
0/5 Vdc (H activ)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0, 24th February 2009
DC-AC INVERTER UNIT
PS-M06D12S4-NJ4L-124(S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Note 1 :
Note 2:
Note 3:
Symbols
Iout
Vin (V)
12±0.12
Iout
Iin1
F
Vopen
12±1.2
12±1.2
12±01.2
11.4 m in.
Conditions
Vrmt (V) Tu (°C)
0
0~+60
0
0
0
0
0~+60
0~+60
0~+60
0~+60
Min.
5.5
Specification
Typ.
Max.
6.0
6.5
5.0
45
1.200
6.0
0.7
55
1.300
7.0
1.2
65
-
Unit
Note
m Arm s
Duty 100%
m Arm s
A
kHz
Vrm s
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
PWM Disable (CN1-5) has priority over the Brightness PWM signal (CN1-3). When dimming via the
Brightness PWM signal (CN1-3) is requested, PWM Disable has to be set to L or left open.
The Brightness PWM should be in a range of 100 ~ 500 Hz. For other frequency please request.
The optimum is 250 Hz. Here you will normally not get a interference to the vertical sync. frequency.
TEST CIRCUIT :
F
Vin
12 V
Iin
A
1000:1
PROBE
F
CN1-1
Vopen V
~
SW3
V
CN2-1
CN1-2
SW4
CN1-3
Brightness PWM
0% = max. Brightness
100% = min. Brightness
0~0.5=OFF/
2,5~Vin=ON
T1
RL2
RL1
TTL-Level
NC
PWM Disable
H = max. Brightness
L = Brightness set per PWM
CN2-2
CN2-3
CN1-4
b
CL1
SW5
a
V
CL2
A
A
N.C.
~
~
Iout
Iout1
2
SW1
CN2-4
CN1-5
*) Only active when Vrmt is 0 Vdc or floating
Backlight Mode
Full
bright
Dimming
support
OFF
PWM Disable
H
L
L
BRIGHTNESS
PWM
X
0%=full on
100%=full off
100%=H
(high Z)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specifications are subject to change without notice.
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)
Version 1.0, 24th February 2009