PS_PS-M06D05S5-NJ1L-108.pdf

DC-AC INVERTER UNIT
PS-M06D05S5-NJ1L-108 (S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION :
This low profile DC to AC Inverter is developed for dual lamps.
Optimized for Sharp: LQ104V1DG61
APPLICABLE LCD:
6.4 to 12 inches double lamp type
Lamp Voltage 466 Vrms
Lamp Current 6.0 mArms
Lamp Start Up Voltage 1500 Vrms (Vin : 5 Vdc)
FEATURES :
Remote ON/OFF
Ext. PWM-Dimming Function
RoHS complain (S)
TEMPERATURE & HUMDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
5 ± 0.5
122,5 ± 0.5
30,5 ± 0.5
82 ± 0.3
(2)
PS-M06D05-NJ1L
29/01/2004
MADE IN
GERMANY
CN1
1
15 ± 0.3
22,5 ± 0.5
-30°C ~ +70°C
-40°C ~ +85°C
95 %RH max
CN2
CAUTION
HIGH VOLTAGE
CN3
1
1
10.0MAX
3
2 - Ø2.5 ± 0.2
2
Unit : mm
Weight :20 (g) typ.
1
High Voltage generation area 60mm
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
Part Discription
PCB
Connector CN1
Qty.
1
1
Material
UL94V-0 (FR-4 or CEM-3)
S5B-PH-SM3
Note
t=1.6m m
JST or equal
3
Connector CN2 + CN3
2
SM02(8.0)B-BHS
JST or equal
Input side CN1:
Pin No.
CN 1-1
CN 1-2
CN 1-3
CN 1-4
Symbols
Vin
GND
Ext. PWM
N.C.
CN 1-5
Vrm t
Output side CN2 + CN3:
Ratings
5 Vdc
Pin No.
CN 2-1
CN 2-2
Symbols
VHIGH1
N.C.
Ratings
466Vrm s (6.0m Arm s )
-
0 ~ 5 Vdc (L activ)
CN 2-3
VLOW
0Vdc
0 / 5 Vdc (H activ)
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (1)
Version 1.0, 26th October 2006
DC-AC INVERTER UNIT
PS-M06D05S5-NJ1L-108 (S) (6,5 W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
ELECTRICAL CHARACTERISTICS :
Parameters
Symbols
Output Current
Output Current
Input Current
Frequency
Open Circuit Voltage
Iout
Iout
Iin
F
Vopen
Note 1 :
Note 2:
Note 3:
Vin (V)
5±0.05
5±0.5
5±0.5
5±0.5
4.75
Conditions
Vrmt
Tu (°C)
(V)
5±0.25 -30 ~ +70
5±0.25 -30 ~ +70
5±0.25 -30 ~ +70
5±0.25 -30 ~ +70
5±0.25 -30 ~ +70
Specification
Min.
Typ.
Max.
5.2
5.0
50
1.500
6.0
6.0
1.6
60
-
6.8
7.0
2.5
70
-
Unit
Note
m Arm s
m Arm s
Adc
kHz
Vrm s
Dut y Cycle 100 %
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked on
mechanical drawing and any conductors.
Remote ON/OFF (CN1-5) has priority and can not be used in combination with External PWM Dimming
(CN1-3). When 'Ext.PWM' (CN1-3) is used 'Vrmt' (CN1-5) should not be connected.
The external PWM frequency should be in a range of 100 ~ 500 Hz. For other frequency please
request. The optimum is 250 Hz. Here you will normally not get a interference to the vertical sync. frequency.
TEST CIRCUIT :
SW 1
Operation of unit
a
Operation
b
Non operation
EXTERNAL PWM-DIMMING ( Remote ON / OFF Detailed Circuit Diagram ):
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Page (2)