DR058-F1_2016.pdf

2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058-F1
2 to 18GHz Instantaneous Frequency Measurement Unit
The DR058-F1 utilises proprietary Teledyne Defence Limited
(TDL) technology to provide state of the art performance in a
package measuring only 152mm x 147mm x 30mm and
weighing 1.55kg.
Designed specifically for fast jet applications this product will
withstand the most demanding of environments. It is
characterised for –40ºC to +85ºC. For applications outside
this range, please contact the TDL sales team.
The DR058-F1 is a clocked sampling IFM, providing a digital
14-bit output word of the RF input frequency for each clock
cycle. An external trigger will force a sample to be taken
asynchronously. The internal analogue bandwidth is sufficient
to capture a 50ns pulse.
External connections are made via a 51 way high density D
type for power and digital I/O and SMA for the RF input.
With a resolution of 14 bits, the DR058-F1 gives a nominal
frequency resolution of 1 MHz and an rms accuracy of
≤4.5MHz with an input SNR of 3dB or better.
FEATURES
•
•
•
•
•
•
•
14 Bit resolution
External trigger or clocked sampling
50ns pulse capable
16GHz Instantaneous bandwidth
-50dBm sensitivity
Small form factor
Low weight
Low power consumption
This product is recommended for new designs. Other IFM
configurations are available and for further information,
please contact the TDL Sales Team.
APPLICATIONS
•
Electronic Support Measures (ESM)
•
Radar Warning Receivers (RWR)
•
ECM Set-on
•
Airborne, Fixed Wing & Rotary
•
Land
•
Naval
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058-F1 | 022016 | Page 1 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058-F1
ELECTRICAL SPECIFICATIONS
Ref
Parameter
Units
Value
Min
1
Operating Frequency Range
2
3
Nom
Notes
Max
GHz
1.955
Unambiguous Bandwidth
GHz
1.5
Frequency Resolution
MHz
1
4
Digital Frequency Resolution
Bits
14
5
Clock Rate
MHz
15
50
6
Throughput Time
ns
88
118
7
RF Input Dynamic Range
dBm
-50
10
8
RF Input Signal/Noise Ratio
dB
3
50
9
RF Input Pulse Width
ns
10
Recovery Time
ns
11
RF Input VSWR
12
Frequency Error (RMS) at 3 dB SNR
MHz
Frequency Peak Error at 3 dB SNR
MHz
14
Peak Error Rate at 3 dB SNR
15
16
18
18.5
1
3
CW
4
50
5
4.5
6
%
0.04
7
Bad Data Error Rate at 3 dB SNR
%
1
8
Simultaneous Signal: Level
Simultaneous Signal: Frequency
Separation
Overload Power
dBc
15
6
10
MHz
9
100
dBm
9
20
19
Temperature Range (operating)
20
Power Consumption
21
Power Supply Current: +12v Rail
mA
900
22
Power Supply Current: +5v Rail
mA
2500
23
Power Supply Current: -5v Rail
mA
350
24
Weight (Approx.)
kg
1.55
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
2
2.2:1
13
17
18.045
°C
Watts
-40
10
85
25
Nominal frequency resolution is unambiguous bandwidth divided by number of bits.
See timing diagrams. Based on a 50 MHz clock.
Minimum SNR required for nominal operation.
Minimum pulse width is defined by internal video bandwidth.
Given as the maximum time required between the removal of a pulse of RF at any power within the operating
dynamic range and the arrival of the next pulse to ensure the correct measurement of the second pulse.
The actual resolution, i.e.,the change of frequency required to change 1 bit of the output word varies with
frequency. The rms accuracy is calculated as the standard deviation of the frequency distribution. The rms
accuracy is specified for 3dB and 0dB input SNR. The rms error excludes those measurements that are
flagged as “bad data”.
The percentage number of measurements that exceed the peak error frequency.
The percentage number of measurements that cause the ‘bad data’ signal to be asserted.
Simultaneous signals are defined as signals which overlap by at least 30ns during a measurement cycle. A
valid measurement will be made on the larger of two signals provided that a) the amplitude difference between
them is 10dB and b) there is at least 100MHz frequency separation.
Maximum input power without damage.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058-F1 | 022016 | Page 2 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058-F1
TIMING INFORMATION
Continuously Clocked Mode
Parameter
Tclk
Trfpw
Topdly
Tvs
Tmeas
Description
ClockPeriod
RF Pulse Width
Data Output Delay
Video Settling time
Throughput Time from settled video
digitisation
Min
Timings
Nominal
20 ns
Tclk+30 ns
0 ns
15 ns
Max
67 ns
CW
10 ns
25 ns
Tclk(3.5±0.5)+Topdly
Note that the recovery time between two consecutive pulses can be as low asTclk.
No Data Valid output is provided in continuous clock mode.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058-F1 | 022016 | Page 3 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058-F1
TIMING INFORMATION
Triggered Mode
Timings
Nominal
Parameter
Description
Tclk
Clock Period
Min
20 ns
Trfpw
RF Pulse Width
50 ns
Textrpw
External Trigger Width
35 ns
CW
Topdly
Data Output Delay
0 ns
Trec (Note 1)
Recovery Time
10 ns
50 ns
Ttrd (Note 2)
Trigger Delay from RF
Tmeas
Throughput Time
Max
67 ns
CW
4 ns
12 ns
Trd+Tclk
(4.5±0.5)+Topdly
Note 1 If a second pulse starts within this period the frequency measured may not be correct.
Note 2 This timing will ensure that the frequency within a 50 ns pulse is measured correctly..
When no external trigger is supplied, but RF is present, the device will run in continuous clock mode. The rising
edge of ExtTrigger causes the digitized tier video data at the front of the pipeline to be held (frozen) after a delay
of approximately 25 ns (to allow video to settle) for a minimum period of 1 clock cycle to guarantee that this data
enters the pipeline at the next rising clock edge.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058-F1 | 022016 | Page 4 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058-F1
PIN DESIGNATIONS
Pin
Signal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
IFM Clock +
0V
0V
Ext Trigger Freq 1 Ext Trigger +
Freq 3 Bad Data Freq 7 Freq 9 Data Valid Freq 11 Data Valid +
Freq 12 0V
0V
-5V
0V
IFM Clock +
0V
0V
Freq 0 Freq 1 +
Freq 2 Freq 3 +
Freq 4 Bad Data +
Freq 8 Freq 11 +
Freq 10 Freq 12 +
0V
Freq 13 0V
Freq 13 +
+12V
0V
Freq 0 +
Freq 2 +
Freq 4 +
Freq 5 +
Freq 5 Freq 7 +
Freq 6 +
Freq 6 Freq 9 +
Freq 8 +
Freq 10 +
OV
+5V
+5V
Direction
Input
Return
Return
Input
Output
Input
Output
Output
Output
Output
Output
Output
Output
Output
Return
Return
Power
Return
Input
Return
Return
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Return
Output
Return
Output
Power
Return
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Return
Power
Power
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058-F1 | 022016 | Page 5 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058-F1
ENVIRONMENTAL SCREENING
100% of units subjected to: burn in 8 hours operational at 71ºC, random vibration (as below), 5min per axis,
thermal shock (as below), random vibration (as below), 5min per axis.
Environmental Data
Compliance can be shown by similarity to the following environmental conditions:
Sinusoidal Vibration: MIL-STD-202F, Method 204 - 5g profile between 5 and 104Hz for 90 min per axis
Random Vibration: MIL-STD-810D, Method 514.3 – specified profile (below) with max of 0.2g²/Hz for 60
min per axis, 20 to 2000Hz
Mechanical Shock: MIL-STD-202F, Method 213B – 15g/11ms, 3 shocks in each axis in each
direction (18 total) Acceleration: MIL-STD-202F, Method 212A, condition B, 6 to 14g
High Temperature storage: MIL-STD-810D, Method 501.2 - 95ºC for 8 hours
High Temperature operational: MIL-STD-820D, Method 501.2 – 71ºC / 30min, 60ºC / 60min,
55ºC / 4hr Thermal Shock: 10 Cycles of –40ºC to 71ºC, 5 min ramp, 2hr dwell
Low Temperature storage: MIL-STD-810D, Method 502.2 - -54ºC for 8 hours.
Low temperature operational: MIL-STD-810D, Method 502.2 - -40ºC / 60min.
DR058- Combined temperature, altitude & humidity: MIL-STD-810D. Method 520 – temperature –40ºC
F1
to 70ºC, storage condition sea level to 17000m (87.6mb), operating condition sea level to
11000m (228mb), relative humidity at sea level 75%, 10 Cycles.
Humidity: MIL-STD-810D, Method 507.2, procedure 2 – RH 85% to 95%, temperature 30ºC to
60ºC, 24 hour cycle, 10 cycles.
EMI/EMC: Generally in accordance with MIL-STD-461E. Please note that system precautions
must be taken to prevent interfering signals entering the high gain RF front end.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058-F1 | 022016 | Page 6 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058-F1
OUTLINE DRAWING
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058-F1 | 022016 | Page 7 of 7