DR058_2016.pdf

2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058
2 to 18GHz Instantaneous Frequency Measurement Unit
The DR058 utilises proprietary Teledyne Defence Limited (TDL)
technology to provide state of the art performance in a package
measuring only 152mm x 147mm x 30mm and weighing 1.55kg.
The DR058 is a clocked sampling IFM, providing a digital 12-bit
output word of the RF input frequency for each clock cycle. An
external trigger will force a sample to be taken asynchronously.
The internal analogue bandwidth is sufficient to capture a 50ns
pulse.
with an input SNR of 3dB or better. Designed specifically for
fast jet applications, this product will withstand the most
demanding of environments. It is characterised for –40ºC to
+85ºC. For applications outside this range, please contact the
TDL sales team.
External connections are made via a 51 way high density D
type for power and digital I/O and SMA for the RF input.
With a resolution of 12 bits, the DR058 gives a nominal
frequency resolution of 3.93MHz and an rms accuracy of 4.5MHz
This product is recommended for new designs. Other IFM
configurations are available and for further information, please
contact the TDL Sales Team.
FEATURES
APPLICATIONS
•
•
•
•
•
•
•
•
•
•
•
•
•
•
12 Bit Resolution
External trigger or clocked sampling
50ns pulse capable
16GHz Instantaneous bandwidth
-50dBm sensitivity
Small form factor
Low Weight
Low Power Consumption
Electronic Support Measures (ESM)
Radar Warning Receivers (RWR)
ECM Set-on
Airborne, Fixed Wing & Rotary
Land
Naval
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058 | 022016 | Page 1 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058
ELECTRICAL SPECIFICATIONS
Ref
Parameter
Units
Value
Min
1
Operating Frequency Range
2
3
4
Nom
Notes
Max
GHz
1.955
Unambiguous Bandwidth
GHz
1.5
Frequency Resolution
MHz
3.93
Digital Frequency Resolution
Bits
12
5
Clock Rate
MHz
10
50
6
Throughput Time
ns
106
139
7
RF Input Dynamic Range
dBm
-50
10
8
RF Input Signal/Noise Ratio
dB
3
50
9
RF Input Pulse Width
ns
10
Recovery Time
ns
11
RF Input VSWR
12
Frequency Error (RMS) at 3 dB SNR
MHz
13
Frequency Peak Error at 3 dB SNR
MHz
14
Peak Error Rate at 3 dB SNR
15
16
17
18
18.045
18.5
1
3
CW
4
50
5
2.2:1
4.5
6
%
0.04
7
Bad Data Error Rate at 3 dB SNR
%
1
8
Simultaneous Signal: Level
Simultaneous Signal: Frequency
Separation
Overload Power
dBc
15
10
MHz
9
100
dBm
9
20
Temperature Range (operating)
Power Consumption
21
Power Supply Current: +15v Rail
mA
900
22
Power Supply Current: +5v Rail
mA
2500
23
Power Supply Current: -5v Rail
mA
350
24
Weight (Approx.)
kg
1.55
•
•
•
•
Watts
-40
10
20
•
°C
6
19
•
•
•
•
•
2
85
25
Nominal frequency resolution is unambiguous bandwidth divided by number of bits.
See timing diagrams. Based on a 40 MHz clock.
Minimum SNR required for nominal operation.
Minimum pulse width is defined by internal video bandwidth.
Given as the maximum time required between the removal of a pulse of RF at any power within the operating
dynamic range and the arrival of the next pulse to ensure the correct measurement of the second pulse.
The actual resolution, i.e.,the change of frequency required to change 1 bit of the output word varies with
frequency. The rms accuracy is calculated as the standard deviation of the frequency distribution. The rms
accuracy is specified for 3dB and 0dB input SNR. The rms error excludes those measurements that are flagged
as “bad data”.
The percentage number of measurements that exceed the peak error frequency.
The percentage number of measurements that cause the ‘bad data’ signal to be asserted.
Simultaneous signals are defined as signals which overlap by at least 30ns during a measurement cycle. A valid
measurement will be made on the larger of two signals provided that a) the amplitude difference between them is
10dB and b) there is at least 100MHz frequency separation.
Maximum input power without damage.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058 | 022016 | Page 2 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058
TIMING INFORMATION
Continuously Clocked Mode
Parameter
Description
Tclk
ClockPeriod
Trfpw
RF Pulse Width
Topdly
Timings
Nominal
Min
Max
20 ns
67 ns
Tclk+30 ns
CW
Data Output Delay
0 ns
10 ns
Tvs
Video Settling time
15 ns
25 ns
Tmeas
Throughput Time from settled video
digitisation
Tclk(3.5±0.5)+Topdly
Note that the recovery time between two consecutive pulses can be as low as Tclk.
No Data Valid output is provided in continuous clock mode.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058 | 022016 | Page 3 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058
TIMING INFORMATION
Triggered Mode
Timings
Nominal
Parameter
Description
Tclk
Clock Period
20 ns
67 ns
Trfpw
RF Pulse Width
50 ns
CW
Textrpw
External Trigger Width
35 ns
CW
Topdly
Data Output Delay
0 ns
10 ns
Trec (Note 1)
Recovery Time
Ttrd (Note 2)
Trigger Delay from RF
4 ns
12 ns
Tvs
Video Setting Time
15ns
25ns
Tmeas
Throughput Time
Min
Max
50 ns
Trd+Tclk
(4.5±0.5)+Topdly
Note 1 If a second pulse starts within this period the frequency measured may not be correct.
Note 2 This timing will ensure that the frequency within a 50 ns pulse is measured correctly.
When no external trigger is supplied, but RF is present, the device will run in continuous clock mode. The rising edge
of ExtTrigger causes the digitized tier video data at the front of the pipeline to be held (frozen) after a delay of
approximately 25 ns (to allow video to settle) for a minimum period of 1 clock cycle to guarantee that this data enters
the pipeline at the next rising clock edge.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058 | 022016 | Page 4 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058
PIN DESIGNATIONS
Pin
Signal
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
IFM Clock +
0V
0V
Ext Trigger Freq 1 Ext Trigger +
Freq 3 Bad Data Freq 7 Freq 9 Data Valid Freq 11 Data Valid +
Not used
0V
0V
-5V
0V
IFM Clock +
0V
0V
Freq 0 Freq 1 +
Freq 2 Freq 3 +
Freq 4 Bad Data +
Freq 8 Freq 11 +
Freq 10 Not used
0V
POST 0V
POST +
+12V
0V
Freq 0 +
Freq 2 +
Freq 4 +
Freq 5 +
Freq 5 Freq 7 +
Freq 6 +
Freq 6 Freq 9 +
Freq 8 +
Freq 10 +
OV
+5V
+5V
Direction
Input
Return
Return
Input
Output
Input
Output
Output
Output
Output
Output
Output
Output
Return
Return
Power
Return
Input
Return
Return
Output
Output
Output
Output
Output
Output
Output
Output
Output
Return
Output
Return
Output
Power
Return
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Output
Return
Power
Power
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058 | 022016 | Page 5 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058
ENVIRONMENTAL SCREENING
100% of units subjected to: burn in 8 hours operational at 71ºC, random vibration (as below), 5min per axis,
thermal shock (as below), random vibration (as below), 5min per axis.
Environmental Data
Compliance can be shown by similarity to the following environmental conditions:
Sinusoidal Vibration: MIL-STD-202F, Method 204 - 5g profile between 5 and 104Hz for 90 min per axis
Random Vibration: MIL-STD-810D, Method 514.3 – specified profile (below) with max of 0.2g²/Hz for 60 min
per axis, 20 to 2000Hz
Mechanical Shock: MIL-STD-202F, Method 213B – 15g/11ms, 3 shocks in each axis in each direction (18
total) Acceleration: MIL-STD-202F, Method 212A, condition B, 6 to 14g
High Temperature storage: MIL-STD-810D, Method 501.2 - 95ºC for 8 hours
High Temperature operational: MIL-STD-820D, Method 501.2 – 71ºC / 30min, 60ºC / 60min, 55ºC / 4hr
Thermal Shock: 10 Cycles of –40ºC to 71ºC, 5 min ramp, 2hr dwell
Low Temperature storage: MIL-STD-810D, Method 502.2 - -54ºC for 8 hours.
Low temperature operational: MIL-STD-810D, Method 502.2 - -40ºC / 60min.
DR058 Combined temperature, altitude & humidity: MIL-STD-810D. Method 520 – temperature –40ºC to 70ºC,
storage condition sea level to 17000m (87.6mb), operating condition sea level to 11000m (228mb), relative
humidity at sea level 75%, 10 Cycles.
Humidity: MIL-STD-810D, Method 507.2, procedure 2 – RH 85% to 95%, temperature 30ºC to 60ºC, 24
hour cycle, 10 cycles.
EMI/EMC: Generally in accordance with MIL-STD-461E. Please note that system precautions must be taken
to prevent interfering signals entering the high gain RF front end.
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058 | 022016 | Page 6 of 7
2 to 18GHz Instantaneous
Frequency Measurement Unit
DR058
OUTLINE DRAWING
See restrictions on published datasheets at www.teledynedefence.co.uk/
Teledyne Defence, Airedale House
Royal London Industrial Estate Acorn Park, Charlestown Shipley,
West Yorkshire | UK, BD17 7SW
Tel: +44 (0) 1274 531` 602 | Fax: +44 (0) 1274 595 724
Email: [email protected] | Web: www.teledynedefence.co.uk
DR058 | 022016 | Page 7 of 7