8 7 6 5 4 3 2 ALUMINUM COMPATIBLE LASER WELDABLE 50 OHM FEEDTHROUGH SMP ADAPTABLE, .015 DIAMETER CENTER CONTACT, PRESS-IN D SRIFT1011 DOCUMENT REVISIONS REV CHANGE NO. DATE CFG APPROVAL - INIT RLSE 2010-10-27 J. PETRI • FULL SHROUD/FULL BODY CONFIGURATION FOR INTERFACING TO SMP "BULLET" STYLE ADAPTER • DESIGNED TO LASER WELD INTO AN ELECTRONIC CHASSIS D • INDUSTRY STANDARD NICKEL-IRON-COBALT ALLOY CONTACT WITH CORNING 7070 EQUIVALENT GLASS • INTEGRAL RF GROUNDING TAB FOR EXCELLENT PERFORMANCE OVER TEMPERATURE 1. LEAK RATE: LESS THAN OR EQUAL TO 1X10E-9 CC/SEC He AT ONE ATMOSPHERE DIFFERENTIAL PRESSURE. 2. NOMINAL IMPEDANCE: 50 OHMS 3. INTERFACE IN ACCORDANCE WITH MIL-STD-348, SMP (FULL BODY). 4. MATERIALS: PIN: NICKEL-IRON-COBALT ALLOY IN ACCORDANCE WITH ASTM F15. DIELECTRIC: CORNING 7070 EQUIVALENT GLASS (MATCHED SEAL). SHELL (WELD FLANGE): ALUMINUM ALLOY 4047 IN ACCORDANCE WITH AWS A5.8. RF GROUNDING SPRING: BERYLLIUM-COPPER ALLOY 172/173 IN ACCORDANCE WITH ASTM B 194 (NICKEL/GOLD PLATE) C 5. FINISH: FERRULE, PIN AND GROUNDING SPRING: NICKEL PLATE PER QQ-N-290, CLASS 2, .000100/.000250 THICK GOLD PLATE PER ASTM B488-01, TYPE III, CODE A, .000050/.000100 THICK. C 6. ORDERING INSTRUCTIONS: SPECIFY BASE NUMBER FOLLOWED BY DASH NUMBER INDICATING DETENT TYPE, PIN EXTENSION AND DIELECTRIC APPLICATION TYPE: EXAMPLE: SRIFT1011 - FD 130 A DIELECTRIC APPLICATION TYPE (A-AIR, T-TEFLON) PIN EXTENSION (L) DETENT TYPE (FD -FULL, LD - LIMITED, SB - SMOOTH) BASE NUMBER B B VIEWS SHOWN WITHOUT GROUNDING SPRING UNLESS OTHERWISE SPECIFIED A DIMENSIONING IAW ASME Y14.5M-1994 DIMENSIONS APPLY AFTER PROCESSES DIMENSIONS IAW US CUSTOMARY UNITS .X .1, .XX .01, .XXX .005, .5 .010 MAX OUTSIDE R, .005 MAX INSIDE R 125 RMS SURFACE FINISH THIRD ANGLE PROJECTION SRI HERMETICS TITLE FEEDTHROUGH, SMP, AC LBW, PRESS-IN (FULL/FULL) SIZE DOCUMENT A SCALE FORM 300067 REV - 7 6 5 4 3 (321) 254-4067 WWW.SRIHERMETICS.COM 8:1 2 CAGE CODE SRIFT1011 3PJY7 SHEET 1 REV - 1 OF 2 A 8 6 7 4 5 3 2 SRIFT1011 DOCUMENT .182 L .003 D D .015±.001 .207 MAX (OVER KNURL) PIN INSTALL THIS DIRECTION C WELD FLANGE SHELL .072±.002 FERRULE VIEW SHOWN WITHOUT RF GROUNDING SPRING STRAIGHT KNURL DETENT C 8X 45° .190±.002 .036 (AIR DIELECTRIC APPLICATION) .050 (TEFLON DIELECTRIC APPLICATION) .049 .001 B .035 .001 THRU (AIR DIELECTRIC) AS REQUIRED (TEFLON DIELECTRIC) .193 .001 AS SHOWN .203 .001 .100 .002 AS SHOWN .005 .002 .0020±.0005 8X .012 .182±.001 AS REQUIRED B RF GROUNDING SPRING PART NUMBER SRIFT1010-GS-A (AIR DIELECTRIC APPLICATION) PART NUMBER SRIFT1010-GS-T (TEFLON DIELECTRIC APPLICATION) SHIPPED UNINSTALLED .030 MIN .003 MAX BRK O (TEFLON DIELECTRIC, OPTIONAL) THRU (AIR DIELECTRIC) UNLESS OTHERWISE SPECIFIED A DIMENSIONING IAW ASME Y14.5M-1994 DIMENSIONS APPLY AFTER PROCESSES DIMENSIONS IAW US CUSTOMARY UNITS .X .1, .XX .01, .XXX .005, .5 .010 MAX OUTSIDE R, .005 MAX INSIDE R 125 RMS SURFACE FINISH NO PLATING THIRD ANGLE PROJECTION SUGGESTED HOLE DETAIL FORM 300067 REV - 7 6 SRI HERMETICS TITLE FEEDTHROUGH, SMP, AC LBW, PRESS-IN (FULL/FULL) SIZE DOCUMENT A SCALE 5 4 3 (321) 254-4067 WWW.SRIHERMETICS.COM 8:1 2 CAGE CODE SRIFT1011 3PJY7 SHEET 1 REV - 2 OF 2 A