8 7 6 5 4 3 ALUMINUM COMPATIBLE LASER WELDABLE 50 OHM FEEDTHROUGH SMP ADAPTABLE, .015 DIAMETER CENTER CONTACT, PRESS-IN D 2 SRIFT1021 DOCUMENT REVISIONS REV DCN REV DATE RELEASE APPROVAL - INIT RLSE 2011-06-28 J. PETRI A DCN001209 2013-10-15 Jim Petri 2015.08.20 17:37:15 -04'00' • CONFIGURATION FOR INTERFACING TO SMP "BULLET" STYLE ADAPTER D • DESIGNED TO LASER WELD INTO AN ELECTRONIC CHASSIS WALL • INDUSTRY STANDARD NICKEL-IRON-COBALT ALLOY CONTACT WITH CORNING 7070 EQUIVALENT GLASS • INTEGRAL RF GROUNDING TAB FOR EXCELLENT PERFORMANCE OVER TEMPERATURE • DROP-IN HIGHER PERFORMANCE REPLACEMENT FOR SRIFT1001 STYLE CONNECTORS. 1. LEAK RATE: LESS THAN OR EQUAL TO 1X10E-9 CC/SEC He AT ONE ATMOSPHERE DIFFERENTIAL PRESSURE. 2. NOMINAL IMPEDANCE: 50 OHMS 3. INTERFACE IN ACCORDANCE WITH MIL-STD-348, SMP. 4. PERFORMANCE: VSWR (TYP) 1.4:1 TO 30 GHZ. C 5. MATERIALS: PIN: NICKEL-IRON-COBALT ALLOY IN ACCORDANCE WITH ASTM F15 DIELECTRIC: CORNING 7070 EQUIVALENT GLASS (MATCHED SEAL) SHELL (WELD FLANGE): ALUMINUM ALLOY 4047 IN ACCORDANCE WITH AWS A5.8 RF GROUNDING SPRING: BERYLLIUM-COPPER ALLOY 172/173 IN ACCORDANCE WITH ASTM B 194 (NICKEL AND GOLD PLATED) C 6. FINISH, CONTACT AND SHELL (EXCEPT WELD FLANGE): NICKEL PLATE PER QQ-N-290, CLASS 2, .000100/.000250 THICK. GOLD PLATE PER ASTM B488, TYPE III, CODE A, .000050/.000150 THICK. A 7. ORDERING INSTRUCTIONS: SPECIFY BASE NUMBER FOLLOWED BY DASH NUMBERS INDICATING DETENT TYPE, PIN LENGTH, AND DIELECTRIC APPLICATION. EXAMPLE: SRIFT1021 - FD 130 A R ADD R FOR FULL RADIUS PIN END CONFIGURATION A=GROUNDING SPRING FOR AIR DIELECTRIC T=GROUNDING SPRING FOR TEFLON DIELECTRIC PIN LENGTH, L=.130 DETENT (FD=FULL, LD=LIMITED, SB=SMOOTH) BASE NUMBER B B A A DIMENSIONING IAW ASME Y14.5M-1994 DIMENSIONS APPLY AFTER PROCESSES DIMENSIONS IAW US CUSTOMARY UNITS .X .1, .XX .01, .XXX .005, .5 .010 MAX OUTSIDE R, .005 MAX INSIDE R 63 RMS SURFACE FINISH THIRD ANGLE PROJECTION (321) 254-4067 a division of WINCHESTER TITLE FEEDTHROUGH, SMP, AC LBW, PRESS-IN SIZE DOCUMENT A DO NOT SCALE DRAWING FORM 300067 REV A 7 6 5 4 3 www.srihermetics.com SCALE 8:1 2 CAGE CODE SRIFT1021 3PJY7 SHEET 1 REV A 1 OF 2 6 7 8 4 5 2 3 DOCUMENT SRIFT1021 .200 L±.003 .108 D D A .015±.001 .207 MAX OVER KNURL PIN END CONFIGURATION CONTACT WELD FLANGE FERRULE SHELL STRAIGHT KNURL C VIEW SHOWN WITHOUT GROUNDING SPRING C .049 .001 .035 .001 THRU (AIR DIELECTRIC) SHOWN (TEFLON DIELECTRIC, OPTIONAL) .118 .0005 SHOWN .203 .001 SHOWN .263 MIN .005 .002 .195±.001 A A INSTALL THIS DIRECTION .161±.002 AS REQUIRED .035 (AIR DIELECTRIC APPLICATION) .050 (TEFLON DIELECTRIC APPLICATION) A .115±.002 8X 45° NO PLATING A B B .010 MAX BRK ALL AROUND .0020±.0005 8X .012 .003 MAX BRK RF GROUNDING SPRING, SHIPPED UNINSTALLED PART NUMBER SRIFT1021-GS1, AIR DIELECTRIC PART NUMBER SRIFT1021-GS2, TEFLON DIELECTRIC O UNLESS OTHERWISE SPECIFIED A DIMENSIONING IAW ASME Y14.5M-1994 DIMENSIONS APPLY AFTER PROCESSES DIMENSIONS IAW US CUSTOMARY UNITS .X .1, .XX .01, .XXX .005, .5 .010 MAX OUTSIDE R, .005 MAX INSIDE R 125 RMS SURFACE FINISH SUGGESTED HOLE DETAIL THIRD ANGLE PROJECTION SRI HERMETICS TITLE FEEDTHROUGH, SMP, AC LBW, PRESS-IN SIZE DOCUMENT A SCALE FORM 300067 REV - 7 6 5 4 3 (321) 254-4067 WWW.SRIHERMETICS.COM 10:1 2 CAGE CODE SRIFT1021 3PJY7 SHEET 1 REV A 2 OF 2 A