EZBEND .034 DIA. 50 OHM COPPER Military (Mil-C-17) Cables HCMC PART NUMBERS HC 20000-1 M17/154-00001 HC 20000-3 M17/154-00002 Impedance (Ohms) 50 +/- 1.0 50 +/- 1.0 Dielectric Strength (KVRMS 60 Hz) 2 2 Corona Extinction (KVRMS 60 Hz) 75.0 Min 75.0 Min Max Operating Frequency (GHz) 40 40 ELECTRICAL DATA MAX ATTENUATION, db/100 FT. AT 20°C AND AVG. PWR., WATTS, UNITY VSWR, 40°C AMB., STILL AIR FREQUENCY GHz ATTEN. AVG. PWR. ATTEN. AVG. PWR. 1.0 60.0 10.0 60.0 10.0 10.0 190.0 3.1 190.0 3.1 20.0 280.0 2.0 280.0 2.0 MECHANICAL DATA Inner Conductor O.D. (inches) .0080 +/- .0005 .0080 +/- .0005 Inner Conductor Material SPCW SPCW Inner Dielectric Material PTFE, F1 PTFE, F1 Dielectric O.D. (inches) .026 +/- .001 .026 +/- .001 Outer Conductor O.D. (inches) .034 +/- .001 .034 +/- .002 -.001 Outer Conductor Material COPPER COPPER/TIN Safe Bend Radius (proper tooling) (inch) .50 .50 Max. Weight (lbs./1000 ft.) 2.6 2.8 Operating Temp. Max. Degrees C -55 / +100 -55 / +100 SRC Haverhill - Division of Winchester Electronics 5590 Skylane Boulevard, Santa Rosa, CA 95403-1086 Telephone: 707-573-1900 Fax: 707-573-1999