Test Procedure for the NCP1063BUCKGEVB Evaluation Board
Necessary Equipment:
•
•
•
•
•
1 Current limited 90 ~ 264Vrms AC source (current limited to avoid board destruction in
case of a defective part) (e.g. KIKUSUI PCR500M)
1 Power Meter (e.g. YOKOGAWA WT210)
1 DC Volt-Meter able to measure up to 50V DC. (e.g. Agilent 34401A)
1 DC Amp-Meter able to measure up to 5A DC. (e.g. Agilent 34401A)
1 DC Electronic Load 0 - 60A (e.g. Chroma 6312A with 63115A Module )
Figure 1: Test Setup for Buck Convertor
Test Procedure (Buck convertor):
1. Connect the test setup as shown in Figure 1.
2. Apply an input voltage, Uin =90 - 264Vac
3. Apply Iout(load) = 0A
4. Check that Uout is no higher than 15V
5. Increate Iout(load) load to: 350 mA
6. Check that Vout is 12V
7. Power down the load
8. Power down Vin
9. End of test