NCP1027ATXGEVB_TEST_PROCEDURE.PDF - 92.0 KB

Test Procedure for the NCP1027ATXGEVB
04/20/2006
Figure 1: Test Setup
Table 1: Required Equipment
Yokogawa Power Meter WT210
ac Power Supply, 85 Vac – 265
Vac, 1 A
Electronic Load, 5 V up to 3 A
NCP1027ATX Evaluation Board
Test Procedure:
1. Connect the test setup as shown in Figure 1.
2. Apply an input voltage, 85 Vac < VIN < 265 Vac, 50 Hz or 60 Hz.
3. Connect electronic load to output connector.
4. Test the conditions given in Table 2.
Multimeter
Table 2: Desired Results
Measurments
1 Output Voltage
2
3
4
5
Input consumption at
high line and no load
Input consumption at
high line line and low
load
Output voltage at high
line and full load
Output voltage at low
line and full load
6 Brownout detection
Maximum output at low
7 line
Maximum output at high
8 line
Conditions
VIN = 100 Vac,
no load
VIN = 230 Vac,
no load
VIN= 230 Vac,
Iload= 0.1 A
VIN = 230 Vac,
Iload = 2.5 A
VIN = 85 Vac,
Iload = 2.5 A
VIN ↓ until VOUT = 0 V,
IOUT = 2 A
VIN = 85 Vac,
IOUT ↑
VIN = 230 Vac,
IOUT ↑
Results
Comments
VOUT = 5 V ± 5%
PIN = 0.09 W ± 15%,
VOUT = 5 V
PIN = 0.83 W ± 10%
VOUT = 5 V
POUT = 0.5 W
No load measurment can
fluctuate, run WT210 in
average mode
VOUT = 5 V ± 5%
VOUT = 5 V ± 5%
VIN = 56 Vac ± 15%
POUTmax = 14 W ± 15%
POUTmax = 18 W ± 15%
Output voltage must
collapse under 56 Vac
Output voltage must
collapse above 14 W
Output voltage must
collapse above 18 W