NCP1421EVB_TEST_PROCEDURE.REV1.PDF - 115.0 KB

Test Procedure for the NCP1421
h
01/01/2004
Oscilloscope
Adjust
Setting
Agilent E3632A
Ch1 : 20mV/div
Ch2 : 2V/div
Time base : 1 uS/div
3.000V 0.0000A
CHANNEL
1
+S
+
-
2
3
-S
KIKUSUI
PLZ153W
IOUT = 1mA ~ 500mA
POWER
34401A
Agilent
MULTIMETER
3.3V
5.0V
VOUT =
DCV
ACV
OHM
<
>
w
FREQ
LO
ON
OFF
LO
<
>
4
Test Procedure:
1.
2.
3.
4.
5.
Connect the test setup as shown above.
Turn OFF the JP1; (Enable the device).
Set the Power Supply to 3.0V and apply to TP1, TP2 (T1, T2).
Apply 500mA loading from the electronic load.
Check the input current (IIN ), output voltage (VOUT) and output ripple;
• For VOUT = 3.3V; JP2 OFF
IIN = 590.7mA ~ 608.7mA
VOUT = 3.267 ~ 3.367V
VRIPPLE ≤ 35mV
• For VOUT = 5V; JP2 ON
IIN = 931.07mA ~ 957.4mA
VOUT = 4.859 ~ 5.0075V
VRIPPLE ≤ 40mV
6. Check the switching waveform at scope CH1 to see whether it is a normal continuous conduction mode switching
node waveform and switching ON time (TON ) is between 0.46µs ~ 1.15µs.