IRF MUR820PBF

Bulletin PD-20898 12/04
MUR820PbF
Ultrafast Rectifier
Features
•
•
•
•
•
trr = 25ns
IF(AV) = 8Amp
VR = 200V
Ultrafast Recovery Time
Low Forward Voltage Drop
Low Leakage Current
175°C Operating Junction Temperature
Lead-Free ("PbF" suffix)
Description/ Applications
International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with
optimized performance of forward voltage drop and ultra fast recovery time.
The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness
and reliability characteristics.
These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as
free-wheeling diode in low voltage inverters and chopper motor drives.
Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over
dissipation in the switching element and snubbers.
Absolute Maximum Ratings
Parameters
VRRM
Peak Repetitive Peak Reverse Voltage
IF(AV)
Average Rectified Forward Current
Max
Units
200
V
8
A
Total Device, (Rated V R ), TC = 150°C
IFSM
Non Repetitive Peak Surge Current
100
IFM
Peak Repetitive Forward Current
16
(Rated V R , Square wave, 20 KHz), TC = 150°C
TJ, TSTG
Operating Junction and Storage Temperatures
-65 to 175
°C
Case Styles
MUR820PbF
Base
Cathode
1
Cathode
3
Anode
TO-220AC
www.irf.com
1
MUR820PbF
Bulletin PD-20898 12/04
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
VBR, Vr
Parameters
Min Typ Max Units Test Conditions
Breakdown Voltage,
200
-
-
V
IR = 100µA
-
-
0.975
V
IF = 8A
-
-
0.895
V
IF = 8A, TJ = 150°C
-
-
5
µA
VR = VR Rated
-
-
250
µA
TJ = 150°C, VR = VR Rated
Blocking Voltage
Forward Voltage
VF
IR
Reverse Leakage Current
CT
Junction Capacitance
-
25
-
pF
VR = 200V
LS
Series Inductance
-
8.0
-
nH
Measured lead to lead 5mm
.
from package body
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
Parameters
trr
Min Typ Max Units Test Conditions
Reverse Recovery Time
-
-
35
-
-
25
-
20
-
ns
IF = 0.5A, IR = 1.0A, IREC = 0.25A
34
IRRM
Peak Recovery Current
Reverse Recovery Charge
Qrr
IF = 1.0A, diF/dt = 50A/µs, VR = 30V
A
TJ = 25°C
IF = 8A
TJ = 125°C
VR = 160V
-
1.7
-
-
4.2
-
-
23
-
nC
TJ = 25°C
-
75
-
TJ = 125°C
diF /dt = 200A/µs
TJ = 25°C
TJ = 125°C
Thermal - Mechanical Characteristics
Parameters
Min
Typ
Max
TJ
Max. Junction Temperature Range
- 65
-
175
TStg
Max. Storage Temperature Range
- 65
-
175
RthJC
Thermal Resistance, Junction to Case
-
-
3.0
RthJA
Thermal Resistance, Junction to Ambient
-
-
50
Thermal Resistance, Case to Heatsink
-
0.5
-
Weight
-
2.0
-
RthCS
Wt
c
Mounting Torque
Marking Device
c
2
Units
°C
°C/ W
g
-
0.07
-
(oz)
6.0
-
12
Kg-cm
5.0
-
10
lbf.in
MUR820
Mounting Surface, Flat, Smooth and Greased
www.irf.com
MUR820PbF
Bulletin PD-20898 12/04
100
(µA)
100
T J = 175˚C
10
Reverse Current - I
10
T = 175˚C
125˚C
1
100˚C
0.1
25˚C
0.01
0.001
J
0
TJ = 150˚C
50
100
150
200
250
Reverse Voltage - VR (V)
Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage
TJ = 25˚C
1000
Junction Capacitance - C T (pF)
Instantaneous Forward Current - I F (A)
R
150˚C
1
0.1
T = 25˚C
J
100
10
0
0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8
Forward Voltage Drop - VFM (V)
1
10
100
1000
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage
Fig. 1 - Typical Forward Voltage Drop Characteristics
Thermal Impedance Z thJC (°C/W)
10
1
D = 0.50
D = 0.20
D = 0.10
D = 0.05
D = 0.02
D = 0.01
PDM
t1
t2
0.1
Notes:
Single Pulse
(Thermal Resistance)
0.01
0.00001
0.0001
0.001
1. Duty factor D = t1/ t2
2. Peak Tj = Pdm x ZthJC + Tc
0.01
0.1
1
t1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
www.irf.com
3
MUR820PbF
Bulletin PD-20898 12/04
10
Average Power Loss ( Watts )
Allowable Case Temperature (°C)
180
170
DC
160
150 Square wave (D = 0.50)
Rated Vr applied
140
see note (2)
130
0
4 RMS Limit
DC
2
0
3
6
9
12
Average Forward Current - I F(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
200
50
VR = 160V
TJ = 125˚C
TJ = 25˚C
IF = 16A
IF = 8 A
IF = 4 A
160
Qrr ( nC )
40
trr ( nC )
D = 0.01
D = 0.02
D = 0.05
D = 0.10
D = 0.20
D = 0.50
6
0
3
6
9
12
Average Forward Current - IF(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current
8
30
IF = 16A
IF = 8 A
IF = 4 A
120
80
20
40
VR = 160V
TJ = 125˚C
TJ = 25˚C
10
100
1000
0
100
1000
di F /dt (A/µs )
di F /dt (A/µs )
Fig. 7 - Typical Reverse Recovery vs. di F /dt
Fig. 8 - Typical Stored Charge vs. di F /dt
(2) Formula used: TC = TJ - (Pd + PdREV) x RthJC ;
Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6);
PdREV = Inverse Power Loss = V R1 x IR (1 - D); IR @ VR1 = rated VR
4
www.irf.com
MUR820PbF
Bulletin PD-20898 12/04
Reverse Recovery Circuit
VR = 200V
0.01 Ω
L = 70µH
D.U.T.
D
di F /dt
dif/dt
ADJUST G
IRFP250
S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
t rr
IF
tb
ta
0
2
Q rr
I RRM
4
0.5 I RRM
di(rec)M/dt
5
0.75 I RRM
1
/dt
di fF/dt
1. diF/dt - Rate of change of current through zero
crossing
2. IRRM - Peak reverse recovery current
3. trr - Reverse recovery time measured from zero
crossing point of negative going I F to point where
a line passing through 0.75 IRRM and 0.50 IRRM
extrapolated to zero current
4. Qrr - Area under curve defined by t rr
and IRRM
t rr x I RRM
Q rr =
2
5. di (rec) M / dt - Peak rate of change of
current during t b portion of t rr
Fig. 10 - Reverse Recovery Waveform and Definitions
www.irf.com
5
MUR820PbF
Bulletin PD-20898 12/04
Outline Table
10.54 (0.41)
MAX.
1.32 (0.05)
3.78 (0.15)
3.54 (0.14)
2.92 (0.11)
2.54 (0.10)
TERM 2
15.24 (0.60)
14.84 (0.58)
1
6.48 (0.25)
6.23 (0.24)
2°
3
14.09 (0.55)
3.96 (0.16)
13.47 (0.53)
3.55 (0.14)
Base
Cathode
1.22 (0.05)
DIA.
0.10 (0.004)
2.04 (0.080) MAX.
1
1.40 (0.05)
2.89 (0.11)
1.15 (0.04)
3
Cathode
Anode
2.64 (0.10)
0.94 (0.04)
0.69 (0.03)
1
3
0.61 (0.02) MAX.
4.57 (0.18)
4.32 (0.17)
5.08 (0.20) REF.
Conforms to JEDEC Outline TO-220AC
Dimensions in millimeters and (inches)
Part Marking Information
IRXC Assembly Line
EXAMPLE: THIS IS A MUR820
LOT CODE 1789
ASSEMBLED ON WW 19, 2001
IN THE ASSEMBLY LINE "C"
PART NUMBER
INTERNATIONAL
RECTIFIER
LOGO
DATE CODE
ASSEMBLY
LOT CODE
IRMX Assembly Line
EXAMPLE: THIS IS A MUR820
LOT CODE 1789
ASSEMBLED ON WW 19, 2001
IN THE ASSEMBLY LINE "C"
6
P = LEAD-FREE
YEAR 1 = 2001
WEEK 19
LINE C
PART NUMBER
INTERNATIONAL
RECTIFIER
LOGO
DATE CODE
ASSEMBLY
LOT CODE
YEAR 1 = 2001
WEEK 19
P = LEAD-FREE
www.irf.com
MUR820PbF
Bulletin PD-20898 12/04
Ordering Information Table
Device Code
MUR
8
20
PbF
1
2
3
4
1
-
Ultrafast MUR Series
2
-
Current Rating (8 = 8A)
3
-
Voltage Rating (20 = 200V)
4
-
y none = Standard Production
y PbF = Lead-Free
Tube Standard Pack Quantity : 50 pieces
Data and specifications subject to change without notice.
This product has been designed and qualified for Industrial Level and Lead-Free.
Qualification Standards can be found on IR's Web site.
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105
TAC Fax: (310) 252-7309
Visit us at www.irf.com for sales contact information. 12/04
www.irf.com
7