STMICROELECTRONICS HCF4035

HCC/HCF4035B
4-STAGE PARALLEL IN/PARALLEL OUT SHIFT REGISTER
..
..
.
..
.
.
..
..
4-STAGE CLOCKED SHIFT OPERATION
SYNCHRONOUS PARALLEL ENTRY ON ALL 4
STAGES
JK INPUTS ON FIRST STAGE
ASYNCHRONOUS TRUE/COMPLEMENT CONTROL ON ALL OUTPUTS
STATIC FLIP-FLOP OPERATION ; MASTERSLAVE CONFIGURATION
BUFFERED INPUTS AND OUTPUTS
HIGH SPEED 12MHz (typ.) AT VDD = 10V
QUIESCENT CURRENT SPECIFIED TO 20V
FOR HCC DEVICE
STANDARDIZED SYMMETRICAL OUTPUT
CHARACTERISTICS
5V, 10V, AND 15V PARAMETRIC RATINGS
INPUT CURR 100nA AT 18V AND 25°C FOR
HCC DEVICE
100% TESTED FOR QUIESCENT CURRENT
MEETS ALL REQUIREMENTS OF JEDEC TENTATIVE STANDARD N°. 13A, ”STANDARD
SPECIFICATIONS FOR DESCRIPTION OF ”B”
SERIES CMOS DEVICES”
DESCRIPTION
The HCC4035B (extended temperature range) and
HCF4035B (intermediate temperature range) are
monolithic integrated circuit, available in 16-lead
dual in-line plastic or ceramic package and plastic
micro package. The HCC/HCF4035B is a fourstage clocked signal serial register with provision for
synchronous PARALLEL inputs to each stage and
SERIAL inputs to the first stage via JK logic. Register stages 2, 3, and 4 are coupled in a serial D flipflop configuration when the register is in the serial
mode (PARALLEL/SERIAL control low). Parallel
entry into each register stage is permitted when the
PARALLEL/SERIAL control is high. In the parallel or
serial mode information is transferred on positive
clock transitions. When the TRUE/COMPLEMENT
control is high, the true contents of the register are
available at the output terminals. When the
TRUE/COMPLEMENT control is low, the outputs
are the complements of the data in the register. The
TRUE/COMPLEMENT control functions asynchronously with respect to the CLOCK signal. JK
input logic is provided on the first stage SERIAL
input to minimize logic requirements particularly in
counting and sequence-generation applications.
July 1989
Whith JK inputs connected together, the first stage
becomes a D flip-flop. An asynchronous common
RESET is also provided.
EY
(Plastic Package)
M1
(Micro Package)
F
(Ceramic Frit Seal Package)
C1
(Plastic Chip Carrier)
ORDER CODES :
HCC4035BF
HCF4035BM1
HCF4035BEY
HCF4035BC1
PIN CONNECTIONS
1/14
HCC/HCF4035B
FUNCTIONAL DIAGRAM
ABSOLUTE MAXIMUM RATINGS
Symbol
V DD*
Parameter
Supply Voltage : HC C Types
H C F Types
Value
Unit
– 0.5 to + 20
– 0.5 to + 18
V
V
Vi
Input Voltage
– 0.5 to V DD + 0.5
V
II
DC Input Current (any one input)
± 10
mA
Total Power Dissipation (per package)
Dissipation per Output Transistor
for T o p = Full Package-temperature Range
200
mW
100
mW
Pt ot
Top
Operating Temperature : HCC Types
H CF Types
– 55 to + 125
– 40 to + 85
°C
°C
Tstg
Storage Temperature
– 65 to + 150
°C
Stresses above those listed under ”Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress rating only and
functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not
implied. Exposure to absolute maximum rating conditions for external periods may affect device reliability.
* All voltage values are referred to VSS pin voltage.
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
VDD
Supply Voltage: HCC Types
HCF Types
VI
Top
Input Voltage
Operating Temperature: HCC Types
HCF Types
2/14
Value
Unit
3 to 18
3 to 15
V
V
0 to VDD
-55 to +125
-40 to +85
V
C
o
C
o
HCC/HCF4035B
LOGIC DIAGRAM
TRUTH TABLE
FIRST STAGE
Clock
(ø )
__
__/
__
__/
__
__/
__
__/
__
__/
__
\__
X
t n - 1 (inputs)
t n (outputs)
J
K
R
Qn -1
Qn
O
X
O
O
O
I
X
O
O
I
X
O
O
I
I
O
O
Q n -1
O
____
Qn-1
Toggle
Mode
X
I
O
I
I
X
X
O
Q n -1
Qn -1
X
X
I
X
O
3/14
HCC/HCF4035B
STATIC ELECTRICAL CHARACTERISTICS (over recommended operating conditions)
Test Conditions
Symbol
IL
V OH
V OL
Parameter
Quiescent
Current
Output High
Voltage
Output Low
Voltage
VI
(V)
VO
(V)
V IL
I OH
0/ 5
5
5
0.04
5
150
HCC
Types 0/15
10
10
0.04
10
300
15
20
0.04
20
600
0/20
20
100
0.08
100
3000
0/ 5
HCF
0/10
Types
0/15
5
20
0.04
20
150
10
40
0.04
40
300
15
80
0.4
80
600
0/ 5
< 1
5
4.95
4.95
4.95
0/10
< 1
10
9.95
9.95
9.95
0/15
< 1
15
14.95
14.95
14.95
5/0
< 1
5
0.05
0.05
0.05
< 1
10
0.05
0.05
0.05
IOL
I IH, I IL
CI
Input Low
Voltage
Output
Sink
Current
Input
leakage
Curent
< 1
15
0.5/4.5
< 1
5
1/9
0.05
3.5
0.05
3.5
< 1
10
7
7
7
15
11
11
11
4.5/0.5
< 1
5
1.5
1.5
1.5
9/1
< 1
10
3
3
3
13.5/1.5 < 1
15
4
4
4
2.5
5
–2
– 1.6 – 3.2
– 1.15
0/ 5
HCC
Types 0/10
4.6
5
– 0.64
– 0.51 – 1
– 0.36
9.5
10
– 1.6
– 1.3 – 2.6
– 0.9
0/15
13.5
15
– 4.2
– 3.4 – 6.8
– 2.4
0/ 5
2.5
5
– 1.53
– 1.36 – 3.2
– 1.1
0/ 5
HCF
Types 0/10
4.6
5
– 0.52
– 0.44 – 1
– 0.36
9.5
10
– 1.3
– 1.1 – 2.6
– 0.9
0/15
13.5
15
– 3.6
– 3.0 – 6.8
– 2.4
0/ 5
0.4
5
0.64
0.51
1
0.36
HCC
0/10
Types
0/15
0.5
10
1.6
1.3
2.6
0.9
1.5
15
4.2
3.4
6.8
2.4
0/ 5
0.4
5
0.52
0.44
1
0.36
HCF
0/10
Types
0/15
0.5
10
1.3
1.1
2.6
0.9
1.5
15
3.6
3.0
6.8
2.4
Input Capacitance
V
mA
mA
18
± 0.1
±10– 5 ± 0.1
±1
15
± 0.3
±10– 5 ± 0.3
±1
µA
5
7.5
* TLow = – 55°C for HCC device : – 40°C for HCF device.
* THigh = + 125°C for HCC device : + 85°C for HCF device.
The Noise Margin for both ”1” and ”0” level is : 1V min. with VDD = 5 V, 2V min. with VDD = 10V, 2.5V min. with VDD = 15V.
4/14
V
Any Input
Any Input
V
0.05
1.5/13.5 < 1
HCF
0/15
Types
µA
3.5
0/ 5
HCC
0/18
Types
Unit
V
10/0
Input High
Voltage
Output
Drive
Current
|I O | V D D
T L o w*
25 °C
T Hi g h *
(µA) (V) Min. Max. Min. Typ. Max. Min. Max.
0/10
15/0
V IH
Value
pF
HCC/HCF4035B
DYNAMIC ELECTRICAL CHARACTERISTICS (T amb = 25°C, C L = 50pF, R L = 200kΩ,
typical temperature coefficient for all V DD = 0.3%/°C, all input rise and fall time = 20ns)
Symbol
Parameter
Test Conditions
Value
V D D (V) Min.
Typ.
Max.
5
250
500
10
100
200
15
75
150
5
100
200
10
50
100
15
40
80
Unit
CLOCKED OPERATION
t PL H, t PHL
t T HL , t TL H
f CL
tW
t r, t f
tsetup
tsetup
Propagation Delay Time
Transition Time
Maximum Clock Input Frequency
Clock Pulse Width
Clock Input Rise or Fall Time
Data Setup Time J/K Lines
Data Setup Time Parallel-In-Lines
5
2
4
10
6
12
15
8
16
5
100
200
45
90
15
30
60
5
15
15
ns
MHz
10
10
ns
ns
µs
15
15
5
110
220
10
40
80
15
30
60
5
70
140
10
25
50
15
20
40
5
230
460
10
100
200
15
80
160
5
125
250
10
55
110
15
40
40
ns
ns
RESET OPERATION
t PL H, t PHL
tW
Propagation Delay Time
Reset Pulse Width
ns
ns
5/14
HCC/HCF4035B
Typical Output Low (sink) Current Characteristics.
Minimum Output Low (sink) Current Characteristics.
Typical Output High (source) Current Characteristics.
Minimum Output High (source) Current Characteristics.
6/14
HCC/HCF4035B
TYPICAL APPLICATIONS
BINARY-TO-BCD CONVERTER
EXAMPLE OF BINARY-TO-BCD CONVERSION
Units
Register
2
1
1
4
8
1
2
4
8
1
0
MSB
LSB
58 = 0
1
Tens
Register
1
0
1
1
1
0
1
0
1
0
1
0
1
1
1
1
1
0
1
0
1
0
1
1
1
0
1
0
1
0
1
0
0
0
1
1
0
Shift
Shift
Shift
Add * 3 to Unit Decade & Shift
0
Shift
0
Add * 3 Units Decade & Shift
* From Left to Right
8
5
7/14
HCC/HCF4035B
TYPICAL APPLICATIONS
BIDEC LOGIC
DOUBLE SEQUENCE GENERATOR
STATE SEQUENCES
Using a control line (E) two different state sequences can be generated. For example, suppose
the following two sequences are desired on command (control line E).
Control = E = 0
0
1
2
5
10
4
9
3
6
13
11
7
14
12
8
8/14
Q1
A
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
Q2
B
0
0
1
0
1
0
0
1
1
0
1
1
1
0
0
Q3
C
0
0
0
1
0
1
0
0
1
1
0
1
1
1
0
1
Q4
D
0
0
0
0
1
0
1
0
0
1
1
0
1
1
1
15
14
13
10
5
11
6
12
9
2
4
8
1
3
7
Q1
A
1
0
1
0
1
1
0
0
1
0
0
0
1
1
1
Q2
B
1
0
0
1
0
1
1
0
0
1
0
0
0
1
1
Q3
C
1
1
1
0
1
0
1
1
0
0
1
0
0
0
1
Q4
D
1
1
1
1
0
1
0
1
1
0
0
1
0
0
0
HCC/HCF4035B
TYPICAL APPLICATIONS
SHIFT LEFT/SHIFT RIGHT REGISTER
TEST CIRCUITS
Quiescent Device Current.
Input Voltage.
Input Current.
9/14
HCC/HCF4035B
Plastic DIP16 (0.25) MECHANICAL DATA
mm
DIM.
MIN.
a1
0.51
B
0.77
TYP.
inch
MAX.
MIN.
TYP.
MAX.
0.020
1.65
0.030
0.065
b
0.5
0.020
b1
0.25
0.010
D
20
0.787
E
8.5
0.335
e
2.54
0.100
e3
17.78
0.700
F
7.1
0.280
I
5.1
0.201
L
Z
3.3
0.130
1.27
0.050
P001C
10/14
HCC/HCF4035B
Ceramic DIP16/1 MECHANICAL DATA
mm
DIM.
MIN.
TYP.
inch
MAX.
MIN.
TYP.
MAX.
A
20
0.787
B
7
0.276
D
E
3.3
0.130
0.38
e3
0.015
17.78
0.700
F
2.29
2.79
0.090
0.110
G
0.4
0.55
0.016
0.022
H
1.17
1.52
0.046
0.060
L
0.22
0.31
0.009
0.012
M
0.51
1.27
0.020
0.050
N
P
Q
10.3
7.8
8.05
5.08
0.406
0.307
0.317
0.200
P053D
11/14
HCC/HCF4035B
SO16 (Narrow) MECHANICAL DATA
mm
DIM.
MIN.
TYP.
A
a1
inch
MAX.
MIN.
TYP.
1.75
0.1
0.068
0.2
a2
MAX.
0.004
0.007
1.65
0.064
b
0.35
0.46
0.013
0.018
b1
0.19
0.25
0.007
0.010
C
0.5
0.019
c1
45° (typ.)
D
9.8
E
5.8
10
0.385
6.2
0.228
0.393
0.244
e
1.27
0.050
e3
8.89
0.350
F
3.8
4.0
0.149
0.157
G
4.6
5.3
0.181
0.208
L
0.5
1.27
0.019
0.050
M
S
0.62
0.024
8° (max.)
P013H
12/14
HCC/HCF4035B
PLCC20 MECHANICAL DATA
mm
DIM.
MIN.
TYP.
inch
MAX.
MIN.
TYP.
MAX.
A
9.78
10.03
0.385
0.395
B
8.89
9.04
0.350
0.356
D
4.2
4.57
0.165
0.180
d1
2.54
0.100
d2
0.56
0.022
E
7.37
8.38
0.290
0.330
e
1.27
0.050
e3
5.08
0.200
F
0.38
0.015
G
0.101
0.004
M
1.27
0.050
M1
1.14
0.045
P027A
13/14
HCC/HCF4035B
Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsability for the
consequences of use of such information nor for any infringement of patents or other rights of third parties which may results from its use. No
license is granted by implication or otherwise under any patent or patent rights of SGS-THOMSON Microelectronics. Specifications mentioned
in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied.
SGS-THOMSON Microelectronics products are not authorized for use ascritical components in life support devices or systems without express
written approval of SGS-THOMSON Microelectonics.
 1994 SGS-THOMSON Microelectronics - All Rights Reserved
SGS-THOMSON Microelectronics GROUP OF COMPANIES
Australia - Brazil - France - Germany - Hong Kong - Italy - Japan - Korea - Malaysia - Malta - Morocco - The Netherlands Singapore - Spain - Sweden - Switzerland - Taiwan - Thailand - United Kingdom - U.S.A
14/14