LEM LA100-SP1

Current Transducer LA 100-S/SP1
IPN
=
100 A
For the electronic measurement of currents : DC, AC, pulsed...,
with a galvanic isolation between the primary circuit (high power)
and the secondary circuit (electronic circuit).
0629
Electrical data
I PN
IP
RM
Primary nominal r.m.s. current
Primary current, measuring range
Measuring resistance
with ± 15 V
ISN
KN
VC
IC
Vd
@ ± 100 A max
@ ± 200 A max
Secondary nominal r.m.s. current
Conversion ratio
Supply voltage (± 5 %)
Current consumption
R.m.s. voltage for AC isolation test, 50 Hz, 1 min
100
0 .. ± 200
RM min RM max
0
0
180
50
50
1 : 2000
± 15
22 + IS
3
A
A
Ω
Ω
ε
Overall accuracy @ IPN, T A = 25°C
Linearity error
L
transducer using the Hall effect
• Insulated plastic case recognized
according to UL 94-V0.
V
mA
kV
Special features
• I P = 0 .. ± 200 A
• K N = 1 : 2000
Advantages
± 0.5
< 0.1
Typ
%
%
Max
± 0.1
± 0.4
IO
IOT
Offset current @ IP = 0, T A = 25°C
Thermal drift of IO
- 10 °C .. + 70°C
± 0.2
tr
di/dt
f
Response time 1) @ 90 % of IPN
di/dt accurately followed
Frequency bandwidth (- 1 dB)
<1
> 50
DC .. 150
mA
mA
µs
A/µs
kHz
•
•
•
•
•
•
•
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
• Current overload capability.
Applications
General data
TA
TS
RS
m
• Closed loop (compensated) current
mA
Accuracy - Dynamic performance data
XG
Features
Ambient operating temperature
Ambient storage temperature
Secondary coil resistance @ T A = 70°C
Mass
Standards 2)
- 10 .. + 70
- 25 .. + 85
85
65
EN 50178
°C
°C
Ω
g
• AC variable speed drives and servo
motor drives
• Static converters for DC motor drives
• Battery supplied applications
• Uninterruptible Power Supplies
(UPS)
• Switched Mode Power Supplies
(SMPS)
• Power supplies for welding
applications.
Notes :
1)
2)
With a di/dt of 50 A/µs
A list of corresponding tests is available.
060901/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
page 1/2
www.lem.com
Dimensions LA 100-S/SP1
(in mm. 1 mm = 0.0394 inch)
Front view
Left view
Secondary terminals
Terminal
Terminal
Terminal
Terminal
+
M
0
:
:
:
:
supply voltage + 15 V
supply voltage - 15 V
measure
NC
Connection
Top view
Mechanical characteristics
•
•
•
•
General tolerance
Fastening
Primary through-hole
Connection of secondary
Remarks
± 0.3 mm
2 holes ∅ 3.2 mm
16 x 10 mm
Molex 5045-04/AG
• IS is positive when IP flows in the direction of the arrow.
• Temperature of the primary conductor should not exceed
100°C.
• Dynamic performances (di/dt and response time) are best
with a single bar completely filling the primary hole.
• In order to achieve the best magnetic coupling, the primary
windings have to be wound over the top edge of the device.
• To measure nominal currents of less than 100 A, the optimum accuracy is obtained by having several primary turns
(nominal current x number of turns < 100 At).
060901/6
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM
Page 2/2
www.lem.com