MA-COM 6DAFP

Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Compact RFI Line Filter with DC Inlet Connection
DA Series
EN
60 950
UL Recognized
CSA Certified
TUV Certified
DAFP
DA Series
DAF1
DAS1
Specifications
• General purpose line filters for DC applications up
to 125VDC.
• Compact with a 3-pin inlet connector
Hipot rating (one minute):
Line to Ground:
LIne to Line:
2250 VDC
1450 VDC
• Available in 3, 6, 10 and 15A versions
Rated Voltage (max):
125 VDC
• Flange mount with 1/4” or PCB terminals
Rated Current:
3 to 15A
• Mates with a standard MOLEX* connector
(HCS Series)
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +55°C
In an ambient temperature (Ta) higher than +55°C
the maximum operating current (Io) is calculated as
follows: Io = Ir (85-Ta)/45
Ordering Information
3 DA F 1
Electrical Schematic
Output Styles
1 – .250 [6.3] spade terminals
P – PC board mount pins
Case Style
F – Flange mount
S – Snap-in
LINE
Accessories
Red
Green/Yellow
Black
DA Series
Current Rating
3, 6, 10 or 15A
GA310 – (shown above) Pre-assembled connector
housing and terminals with three 36” long 18 gauge
wires to mate with DA Series filters
Available Part Numbers
3DAF1
3DAS1
3DAFP
6DAF1
6DAS1
6DAFP
LOAD
10DAF1
10DAS1
10DAFP
15DAF1
15DAS1
15DAFP
MOLEX* connector part numbers:
03-12-1036
Connector housing for DA Series
18-12-1222
Female terminals (3 per connector)
  
212
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011
Corcom Product Guide
Compact RFI Line Filter with DC Inlet Connection
(continued)
DA Series
Case Styles
Case Dimensions
DAF1
Part No.
DAF1
C
A
D
E




B


 

DAS1
DAS1
DAFP
A
B
C



D


















E
















Recommended Panel Cutouts
DAF
A
0.23 max.
.820
20.8
D
.900
22.9
C
.140 Dia. (2)
3.56
1.200
30.48
E
1.575
40.01
1.575
40.01
.12
R
3.05
Back Mount
B


.551
0.815
20.70


R 0.188
4.78
(4x)


DC Filters
DAFP
4
DAS
"A"


.234
R
5.94
Front Mount
Rear View



.140 Dia. (2)
3.56
1.200
30.48
Performance Data
.380 Max.
.537 Ref.
Minimum Insertion Loss
C
Measured in closed 50 Ohm system
A
D
E



B

 

PC Board Layout
Ground
0.104 (3 holes)
2.64
0.520
13.21
Center pin to panel
.685±.015
17.40.38
0.551
13.99
Common Mode / Asymmetrical (Line to Ground)




          
          




































Differential Mode / Symmetrical (Line to Line)




          
          




































213
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com