PERKINELMER TPS534

Lighting
|
Imaging
|
Telecom
p
Thermopile Infrared Detectors
Thermopile Detector
TPS 534
Large absorber size – high signal output
Thermistor temperature reference included
Applications in pyrometers, and - with additional
infrared bandpass filters - in gas detectors
The TPS 534 thermopile sensor inTO 5 type housing employs a chip of 1.2 x 1.2
mm2 absorber size and a 30 kV thermistor as temperature reference. The round
window opening is equipped with a 5.5 µm longpass (standard) infrared filter.
The sensor shows a flat sensitivity characteristics over the wavelength.
Remark: The TPS 534 can also be equipped with infrared bandpass filters for
NDIR gas detection.
TP S
Parameters
534
typical
mm
absorbi ng area
WIndow size
3.8
mm
di ameter
DC S ensitivity
20
V /W
500K BB, 5...14µm
R esistance
40
kW
25°C
Noise
25
nV /Ö Hz
r.m.s. 300K , 1Hz
1.26
nW/Ö Hz
500K BB, 5...14µm
Normalized signal in percent
Right for modification reserved / WS /, 2.7.2001
NEP
80
Time constant
60
cmÖ Hz/W 500K BB, 5...14µm
35
ms
tc of responsivity
-0.01
%/K
40
tc of resistance
0.02
%/K
20
Operating Temperature -40
100
non permanent
-40
120
non permanent
0
S torage Temperature
-100 -80 -60 -40 -20 0
20 40 60 80 100
Angle of incidence in degree
Thermistor R esistance
B eta
Field of view
1.0
TPS 534
Relative signal output
2
0.96 x 108
D*
TPS 534
condition
1.2 x 1.2
S ensitive area
100
units
0.8
-3 dB level
0.6
0.4
0.2
1
10
Frequency in Hz
100
Dimensions in mmm
Europe:
PerkinElmer Optoelectronics GmbH
Wenzel Jaksch Str 31
Wiesbaden / Germany
Phone +49(0)611 492 0
Fax
+49(0)611 492 170
USA:
PerkinElmer Optoelectronics
2175 Mission Colledge Blvd
Santa Clara, CA 95054
Phone +408 565 0830
Fax
+408 565 0703
Asia:
PerkinElmer Optoelectronics
47, Ayer Rajah Crescent #06-12
Singapore 139947
Phone +65 775 2022
Fax
+65 775 1008
www.perkinelmer.com/opto
30
kW
25°C
3964
K
25°C / 100°C
80
°
at 50% poi nts
D A T A S H E E T
Low temperature coefficient of sensitivity