PERKINELMER TPS4339

Lighting
|
Imaging
|
Telecom
p
Thermopile Infrared Detectors
Quad Thermopile
TPS 4339
Thermistor temperature reference included
Internal aperture to avoid cross talk
Standard gas filter sets for reference, CO, hydrocarbon, CO2
The quad thermopile sensor consists of four single thermopile chips mounted in a TO 5
.
housing
with a thermistor as temperature reference. The window size is 1.5 x 1.5 mm2
each. Due to the overall small sensor size the construction of a very compact equipment
becomes possible.
Applications in automotive exhaust gas control, multiple gas detection for the safety product
market or air quality monitoring
For further information please refer to the TPS 4339 product note
Parameters
TP S
typical
units
0.7 x 0.7
mm2
absorbi ng area
1.5 x 1.5
mm
each channel
DC sensitivity
75
V /W
500K BB w/o filter
R esistance
75
kW
Noise
21
nV /Ö Hz
S ensitive area
4x
Window size
NEP
D*
2
condition
r.m.s. 300K
0.28
nW/Ö Hz 500K BB w/o filter
1.6 x 108
cmÖ Hz/W 500K BB w/o filter
1.0
TPS4339
Relative signal
Right for modification reserved / WS /, 5.7.2001
4339
0.8
TC of sensitivity
0.02
%/K
0.6
TC of resistance
0.02
%/K
0.4
Time constant
25
ms
0.2
0.0
-80
-60
-40
-20
0
20
40
60
80
Operating temperature
-40
100
°C
non permanent
S torage temperature
-40
100
°C
non permanent
100
kW
25°C
3964
K
25°C /100°C
60
°
at 50% poi nts
Thermistor
resistance
Incidence angle in degree
beta
Field of view
4x
1.0
Relative signal output
TPS 4339
0.8
-3 dB level
0.6
0.4
0.2
1
10
Frequency in Hz
100
Dimensions in mm
Europe:
PerkinElmer Optoelectronics GmbH
Wenzel Jaksch Str 31
Wiesbaden / Germany
Phone +49(0)611 492 0
Fax
+49(0)611 492 170
USA:
PerkinElmer Optoelectronics
2175 Mission Colledge Blvd
Santa Clara, CA 95054
Phone +408 565 0830
Fax
+408 565 0703
Asia:
PerkinElmer Optoelectronics
47, Ayer Rajah Crescent #06-12
Singapore 139947
Phone +65 775 2022
Fax
+65 775 1008
www.perkinelmer.com/opto
D A T A S H E E T
Four individual thermopiles with different infrared bandpass
filters in TO 5 housing for NDIR gas sensing – up to 4 gases
possible