SANYO STK4362

Ordering number: EN 1229C
Thick Film Hybrid IC
STK4362
AF Power Amplifier
(10W + 10W min, THD = 1.0%)
Features
Package Dimensions
• Capable of guaranteeing substrate temperature 125°C,
thereby reducing heat sink.
• Excellent cost performance.
unit: mm
4033
[STK4362]
Specifications
Maximum Ratings at Ta = 25°C
Parameter
Maximum supply voltage
Symbol
VCC max
θj-c
Thermal resistance
Conditions
Ratings
Pin 4 to 7, 12
One power transistor
Unit
50
V
5
°C/W
Junction temperature
Tj
150
°C
Operating substrate temperature
TC
125
°C
−30 to +125
°C
2
s
Storage temperature
Tstg
Available time for load short-circuit
ts
VCC = 33V, RL = 8Ω, PO = 10W, f = 50Hz
Recommended Operating Conditions at Ta = 25°C
Parameter
Symbol
Conditions
Ratings
Unit
Recommended supply voltage
VCC
33
V
Load resistance
RL
8
Ω
SANYO Electric Co., Ltd. Semiconductor Business Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110 JAPAN
61297HA (ID) / 8058MO / 2043KI, TS No. 1229—1/6
STK4362
Operating Characteristics at Ta = 25°C, VCC = 33V, RL = 8Ω, Rg = 600Ω, VG = 40dB, at specified Test Circuit
(based on Sample Application Circuit).
Parameter
Quiescent current
Symbol
Conditions
min
typ
Unit
120
mA
ICCO
VCC = 38V
20
PO (1)
THD = 1.0%, f = 1kHz
10
W
PO (2)
THD = 1.0%,
f = 30Hz to 20kHz
5
W
Total harmonic distortion
THD
Po = 0.1W, f = 1kHz
Frequency response
fL, fH
Po = 0.1W,
Output power
Input impedance
Output noise voltage
Notes.
ri
VNO
+0
dB
−3
Po = 0.1W, f = 1kHz
VCC = 38V, Rg = 10kΩ
60
max
0.3
%
20 to 100k
Hz
120k
Ω
0.8
mVrms
Unless otherwise specified for the power supply at the time of test, use the
constant voltage power supply.
When testing the available time for load short-circuit and output noise voltage, use the specified transformer as shown right.
The output noise voltage is the peak value on the mean value indicating
rms reading (VTVM), and should not involve impulse noise.
Specified Transformer Power Supply
(Equivalent to RP-22)
Equivalent Circuit
No. 1229—2/6
STK4362
Output power, PO - W
Total harmonic distortion, THD - %
Sample Application Circuit: 10W min 2-channel AF power amplifier
Output power, PO - W
Response - dB
Output power, PO - W
Input voltage, Vi - mV
Frequency, f - Hz
Frequency, f - Hz
No. 1229—3/6
Output noise voltage, VNO - mVrms
Output noise voltage, VNO - mVrms
Power supply ripple voltage, Vrp - mVrms
Frequency, f - Hz
Supply voltage, VCC - V
Quiescent
Neutral current,
voltage, Icco
VN --VmA
Quiescent current, ICCO - mA
Quiescent
Currentcurrent,
drain, IIcco
- mA
CC - A
Output power, PO - W
Input resistance, ri - kΩ
Response - dB
STK4362
Frequency, f - Hz
Supply voltage, VCC - V
Signal source resistance, Rg - Ω
No. 1229—4/6
0.2V / div
Thermal resistance heat sink, θ - °C/W
Current drain, ICC - A
IC Power dissipation, Pd - W
Area of heat sink, S - cm2
Load Short current, Ishort - A
Quiescent
Quiescent current,
current, IIcco
mA
CCO -- mA
Midpoint voltage, VN - V
STK4362
Operating substrate temperature, Tc - °C
Supply voltage, VCC - V
Output power, PO - W
Frequency, f - Hz
0.5s / div
No. 1229—5/6
1V / div
STK4362
0.5s / div
■
No products described or contained herein are intended for use in surgical implants, life-support systems, aerospace equipment, nuclear
power control systems, vehicles, disaster/crime-prevention equipment and the like, the failure of which may directly or indirectly cause injury,
death or property loss.
■
Anyone purchasing any products described or contained herein for an above-mentioned use shall:
➀
Accept full responsibility and indemnify and defend SANYO ELECTRIC CO., LTD., its affiliates, subsidiaries and distributors and all their
officers and employees, jointly and severally, against any and all claims and litigation and all damages, cost and expenses associated
with such use:
➁
Not impose any responsibility for any fault or negligence which may be cited in any such claim or litigation on SANYO ELECTRIC CO.,
LTD., its affiliates, subsidiaries and distributors or any of their officers and employees, jointly or severally.
■
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not guaranteed for volume production. SANYO
believes information herein is accurate and reliable, but no guarantees are made or implied regarding its use or any infringements of
intellectual property rights or other rights of third parties.
This catalog provides information as of June, 1997. Specifications and information herein are subject to change without notice.
No. 1229—6/6