MAXIM DS2784G+T&R

DS2784
1-Cell Stand-Alone Fuel Gauge IC with
Li+ Protector and SHA-1 Authentication
www.maxim-ic.com
GENERAL DESCRIPTION
FEATURES
The DS2784 operates from 2.5V to 4.6V for integration
in battery packs using a single lithium-ion (Li+) or Li+
polymer cell. Available capacity is reported in mAh and
as a percentage. Safe operation is ensured with the
included Li+ protection function and SHA-1-based
challenge-response authentication.
ƒ
Precision measurements of voltage, temperature, and
current, along with cell characteristics and application
parameters are used to estimate capacity. The
available capacity registers report a conservative
estimate of the amount of charge that can be removed
given the current temperature and discharge rate.
ƒ
In addition to the nonvolatile (NV) storage for cell
compensation and application parameters, 16 bytes of
EEPROM memory is made available for the exclusive
use of the host system and/or pack manufacturer. This
facilitates battery lot and date tracking or NV storage of
system or battery usage statistics.
ƒ
®
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Precision Voltage, Temperature, and Current
Measurement System
Available Capacity Estimated from Coulomb
Count, Discharge Rate, Temperature, and Cell
Characteristics
Estimates Cell Aging Using Learn Cycles
Uses Low-Cost Sense Resistor
Allows for Calibration of Gain and
Temperature Coefficient
Li+ Safety Circuitry—Overvoltage,
Undervoltage, Overcurrent, Short-Circuit
Protection
Programmable Safety Thresholds for
Overvoltage and Overcurrent
Authentication Using SHA-1 Algorithm and
64-Bit Secret
32-Byte Parameter EEPROM
16-Byte User EEPROM
Dallas 1-Wire Interface with 64-Bit Unique ID
Tiny, Pb-Free, 14-Pin TDFN Package Embeds
Easily in Battery Packs Using Thin Prismatic
Cells
A 1-Wire interface provides serial communication at
16kbps or 143kbps to access data registers, control
registers, and user memory. Additionally, 1-Wire
communication enables challenge-response pack
authentication using SHA-1 as the hash algorithm in a
hash-based message authentication code (HMAC)
authentication protocol.
ƒ
APPLICATIONS
PIN CONFIGURATION
ƒ
Smartphones/PDAs
Digital Still and Video Cameras
Cordless VOIP Phones
Portable GPS Navigation
Modes and commands are capitalized for clarity.
1-Wire is a registered trademark of Dallas Semiconductor, a wholly
owned subsidiary of Maxim Integrated Products, Inc.
ORDERING INFORMATION
PART
DS2784G+
DS2784G+T&R
TEMP RANGE
-40°C to +85°C
-40°C to +85°C
TOP MARK
DS2784
DS2784
PIN PACKAGE
14 TDFN (3mm x 5mm)
14 TDFN (3mm x 5mm)
+ Denotes a lead-free package.
T&R = tape and reel
1 of 38
REV: 071107
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
ABSOLUTE MAXIMUM RATINGS
Voltage Range on PLS Pin Relative to VSS
Voltage Range on CP Pin Relative to VSS
Voltage Range on DC Pin Relative to VSS
Voltage Range on CC Pin Relative to VSS
Voltage Range on All Other Pins Relative to VSS
Maximum Voltage Range on VIN Pin Relative to VDD
Continuous Sink Current, PIO, DQ
Continuous Sink Current, CC, DC
Operating Temperature Range
Storage Temperature Range
Soldering Temperature (10s)
-0.3V to +18V
-0.3V to +12V
-0.3V to (CP + 0.3V)
VDD - 0.3V to CP + 0.3V
-0.3V to +6.0V
VDD + 0.3V
20mA
10mA
-40°C to +85°C
-55°C to +125°C
See IPC/JEDEC J-STD-020
*This is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the operation
sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods of time may affect reliability.
ELECTRICAL CHARACTERISTICS
(VDD = 2.5V to 4.6V, TA = -20°C to +70°C, unless otherwise noted. Typical values are at TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
Supply Voltage
VDD
(Note 1)
2.5
4.6
IDD0
Sleep mode
1
4
Sleep mode, VDD = 2.5V
0.4
1.5
IDD1
0°C to +50°C
Supply Current
IDD2
Active mode
85
125
IDD3
Active mode during SHA
computation
Temperature Accuracy
Temperature Resolution
Temperature Range
300
-3
+3
0.125
-128.000
4.0 ≤ VIN ≤ 4.6,
VIN ≤ VDD + 0.3V
2.5 ≤ VIN ≤ 4.6V,
VIN ≤ VDD + 0.3V
Voltage Accuracy, VIN
Voltage Resolution, VIN
Voltage Range, VIN
Input Resistance, VIN
500
UNITS
V
μA
μA
o
C
+127.875
-30
30
-50
+50
mV
4.88
0
15
Current Resolution
4.99
mV
V
MΩ
μV
1.56
Current Full Scale
-51.2
+51.2
mV
Current Gain Error
-1
+1
% full
scale
Current Offset
(Notes 2, 3, 4)
-15
+25
μV
Accumulated Current Offset
(Notes 2, 3, 4)
-360
0
μVh/day
-2
+2
-3
+3
0ºC ≤ TA ≤ +50ºC
Time Base Error
CP Output Voltage
VCP
ICC + IDC = 0.9µA
CP Startup Time
tSCP
CE = 0, DE = 0,
CCP = 0.1µF, Active mode
8.50
9.25
%
10.00
V
200
ms
Output High: CC, DC
VOHCC
VOHDC
IOH = -100µA (Note 5)
Output Low: CC
VOLCC
IOL = 100µA
VDD + 0.1
V
Output Low: DC
VOLDC
IOL = 100µA
0.1
V
2 of 38
VCP - 0.4
V
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
PARAMETER
SYMBOL
CONDITIONS
DQ, PIO Voltage Range
MIN
TYP
-0.3
DQ, PIO Input-Logic High
VIH
DQ, PIO Input-Logic Low
VIL
DQ, PIO Output-Logic Low
VOL
DQ, PIO Pullup Current
IPU
DQ, PIO Pulldown Current
IPD
DQ Input Capacitance
CDQ
MAX
UNITS
+5.5
V
1.5
V
IOL = 4mA
Sleep mode,
VPIN = VDD - 0.4V
Active mode,
VPIN = 0.4V
DQ Sleep Timeout
tSLEEP
DQ < VIL
PIO, DQ Wake Debounce
tWDB
Sleep mode
0.6
V
0.4
V
0.2
μA
0.2
μA
50
pF
2
9
100
s
ms
SHA-1 COMPUTATION TIMING
Computation Time
tSHA
30
ms
UNITS
ELECTRICAL CHARACTERISTICS: Protection Circuit
(VDD = 2.5V to 4.6V, TA = 0°C to +50°C, unless otherwise noted. Typical values are at TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
VOV = 11000b
4.457
4.482
4.507
VOV = 00011b
4.252
4.277
4.302
-75
-100
-125
mV
2.40
2.45
2.50
V
OC = 11b
-57
-72
-87
OC = 00b
-15.5
-23.5
-31.5
OC = 11b
76
96
116
OC = 00b
23.5
35.5
47.5
SC = 1b
240
300
360
mV
SC = 0b
120
150
180
mV
Overvoltage Detect
VOV
Charge-Enable Voltage
VCE
Undervoltage Detect
VUV
Overcurrent Detect: Charge
VCOC
Overcurrent Detect: Discharge
VDOC
Short-Circuit Current Detect
VSC
Overvoltage Delay
tOVD
(Note 6)
425
1150
ms
Undervoltage Delay
tUVD
(Notes 6, 7)
84
680
ms
Overcurrent Delay
tOCD
8
10
12
ms
Short-Circuit Delay
tSCD
80
120
160
μs
Test Threshold
VTP
COC, DOC conditions
0.5
1.0
1.5
V
Test Current
ITST
SC, COC, DOC condition
10
20
40
μA
PLS Pulldown Current
IPPD
Sleep mode
100
200
600
μA
IRC
VUV condition,
max: VPLS = 15V,
VDD = 1V
min: VPLS = 4.2V,
VDD = 2V
2.5
5.0
10.00
mA
Recovery Current
Relative to VOV
3 of 38
V
mV
mV
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
EEPROM RELIABILITY SPECIFICATION
(VDD = 2.5V to 5.5V, TA = -20°C to +70°C, unless otherwise noted.)
PARAMETER
SYMBOL
EEPROM Copy Time
tEEC
EEPROM Copy Endurance
NEEC
CONDITIONS
TA = +50°C
MIN
TYP
MAX
UNITS
10
ms
50,000
cycles
ELECTRICAL CHARACTERISTICS: 1-Wire Interface, Standard
(VDD = 2.5V to 5.5V, TA = -20°C to +70°C, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
MAX
UNITS
120
μs
Time Slot
tSLOT
60
Recovery Time
tREC
1
Write-0 Low Time
tLOW0
60
120
μs
Write-1 Low Time
tLOW1
1
15
μs
Read-Data Valid
tRDV
15
μs
Reset-Time High
tRSTH
480
Reset-Time Low
tRSTL
480
960
μs
Presence-Detect High
tPDH
15
60
μs
Presence-Detect Low
tPDL
60
240
μs
MAX
UNITS
16
μs
μs
μs
ELECTRICAL CHARACTERISTICS: 1-Wire Interface, Overdrive
(VDD = 2.5V to 5.5V, TA = -20°C to +70°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN
TYP
Time Slot
tSLOT
6
Recovery Time
tREC
1
Write-0 Low Time
tLOW0
6
16
μs
Write-1 Low Time
tLOW1
1
2
μs
Read-Data Valid
tRDV
2
μs
Reset-Time High
tRSTH
48
Reset-Time Low
tRSTL
48
80
μs
Presence-Detect High
tPDH
2
6
μs
Presence-Detect Low
tPDL
8
24
μs
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
μs
μs
All voltages are referenced to VSS.
Factory-calibrated accuracy. Higher accuracy can be achieved by in-system calibration by the user.
Accumulation bias and offset bias registers set to 00h. NBEN bit set to 0.
Parameters guaranteed by design.
CP pin externally driven to 10V.
Overvoltage and undervoltage delays (tOVD, tUVD) are reduced to 0s if the OV or UV condition is detected within 100ms of entering
Active mode.
tUVD MIN determined by stepping the voltage on VIN from VUV + 250mV to VUV - 250mV.
4 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
TYPICAL OPERATING CIRCUIT
PIN DESCRIPTION
PIN
1
2
3
NAME
VDD
CTG
VSS
4
VIN
5, 9, 10
N.C.
6
PLS
7
8
CC
DC
11
DQ
12
SNS
13
14
PAD
CP
PIO
PAD
FUNCTION
Power-Supply Input. Chip supply input. Bypass with 0.1µF to VSS.
Connect to Ground
Device Ground. Chip ground and battery-side sense resistor input.
Battery Voltage-Sense Input. Connect to positive cell terminal through decoupling
network.
No Connection
Pack Plus Terminal-Sense Input. Used to detect the removal of short-circuit, discharge
overcurrent, and charge overcurrent conditions.
Charge Control. Charge FET control output.
Discharge Control. Discharge FET control output.
Data Input/Output. Serial data I/O, includes weak pulldown to detect battery disconnect
and can be configured as wake input.
Sense Resistor Connection. Pack minus terminal and pack-side sense resistor sense
input.
Charge Pump Output. Bypass with 0.1µF to VSS.
Programmable I/O Pin. Can be configured as wake input.
Exposed Pad. Connect to VSS or float.
5 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
DETAILED DESCRIPTION
The DS2784 functions as an accurate fuel gauge, Li+ protector, and SHA-1-based authentication token. The fuel
gauge provides accurate estimates of remaining capacity and reports timely voltage, temperature, and currentmeasurement data. Capacity estimates are calculated from a piecewise-linear model of the battery performance
over load and temperature, and system parameters for full and empty conditions. The algorithm parameters are
user programmable and can be modified in pack. Critical capacity and aging data are periodically saved to
EEPROM in case of loss of power due to a short circuit or deep depletion.
The Li+ protection function ensures safe, high-performance operation. nFET protection switches are driven with a
9V charge pump that increase gate drive as the cell voltage decreases. The high-side topology preserves the
ground path for serial communication while eliminating the parasitic charge path formed when the fuel gauge IC is
located inside the protection FETs in a low-side configuration. The thresholds for overvoltage, overcurrent, and
short-circuit current are user programmable for easy customization to each cell and application.
The 32-bit wide SHA-1 engine with 64-bit secret and 64-bit challenge words resists brute force and other attacks
with financial-level HMAC security. The challenge of managing secrets in the supply chain is addressed with the
compute next secret feature. The unique serial number or ROM ID can be used to assign a unique secret to each
battery.
BLOCK DIAGRAM
UV, CD
VOLTAGE
(VIN - VSSA)
POWER MODE
Control
10-Bit + sign
ADC/MUX
VIN
TEMPERATURE
LITHIUM ION
PROTECTOR
CURRENT
(VSS - SNS)
PLS
FuelPack™
FuelPack™
Algorithm
ALGORITHM
15-Bit + sign
ADC
SNS
VREF
VSS
PRECISION
ANALOG
OSCILLATOR
CC
FET DRIVERS
DC
WKP, WKD
Control and
Status Registers
CP
PIO
PIO Logic
VDD
CHARGE
PUMP
Pin Drivers
and Pwr
Switch
Control
32 Byte
Parameter
EEPROM
VDD_INT
1-Wire Interface
16 Byte User
EEPROM
DS2784
6 of 38
DQ
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
POWER MODES
The DS2784 has two power modes: Active and Sleep. On initial power-up, the DS2784 defaults to Active mode. In
Active mode, the DS2784 is fully functional with measurements and capacity estimation registers continuously
updated. The protector circuit monitors the battery voltages and current for unsafe conditions. The protection FET
gate drivers are enabled when conditions are deemed safe. Also, the SHA-1 authentication function is available in
Active mode. When a SHA-1 computation is performed, the supply current increases to IDD3 for tSHA. In Sleep mode,
the DS2784 conserves power by disabling measurement and capacity estimation functions, but preserves register
contents. Gate drive to the protection FETs is disabled in Sleep. And the SHA-1 authentication feature is not
operational.
Sleep mode is entered under two different conditions: bus low and undervoltage. An enable bit makes entry into
Sleep optional for each condition. Sleep mode is not entered if a charger is connected (VPLS > VDD + 50mV) or if a
charge current of 1.6mV / RSNS is measured from SNS to VSS. The DS2784 exits Sleep mode upon charger
connection and VIN ≥ VUV or a low to high transition on DQ.
The bus-low condition, where the DQ pin is low for tSLEEP, indicates pack removal or system shutdown in which the
1-Wire bus pullup voltage, VPULLUP, is not present. The power mode (PMOD) bit must be set to enter Sleep when a
bus-low condition occurs. After the DS2784 enters Sleep due to a bus-low condition, it is assumed that no charge
or discharge current will flow and that coulomb counting is unnecessary.
The second condition to enter Sleep is an undervoltage condition, which reduces battery drain due to the DS2784
supply current and prevents over discharging the cell. The DS2784 transitions to Sleep if the VIN voltage is less
than VUV (2.45V typical) and the undervoltage enable (UVEN) bit is set. The 1-Wire bus must be in a static state,
that is, with DQ either high or low for tSLEEP. The DS2784 transitions from UVEN Sleep to Active mode when DQ
changes logic state.
The DS2784 has the “power switch” capability for waking the device and enabling the protection FETs when the
host system is powered down. A simple dry-contact switch on the PIO pin or DQ pin can be used to wake up the
battery pack. The power switch function is enabled using the PSPIO and PSDQ configuration bits in the control
register. When PSPIO or PSDQ is set and a Sleep condition is satisfied, the PIO and DQ pins pull high weakly,
then become armed to detect a low-going transition. A 100ms debounce period filters out glitches that can be
caused when a sleeping battery is inserted into a system.
Figure 1. Sleep Mode State Diagram
7 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
CONTROL REGISTER FORMAT
All control register bits are read and write accessible. The control register is recalled from parameter EEPROM
memory at power-up. Register bit values can be modified in shadow RAM after power-up. Power-up default values
are saved using the Copy Data command.
ADDRESS 60h
BIT 7
NBEN
BIT 6
UVEN
BIT 5
PMOD
BIT 4
RNAOP
BIT 3
0
BIT 2
PSPIO
BIT 1
PSDQ
BIT 0
X
NBEN—Negative Blanking Enable. A value of 1 enables blanking of negative current values up to 25μV. A value of
0 disables blanking of negative currents. The power-up default of NBEN = 0.
UVEN—Undervoltage Enable. A value of 1 allows the DS2784 to enter Sleep mode when the voltage register value
is less than VUV and DQ is stable at either logic level for tSLEEP. A value of 0 disables transitions to Sleep mode in an
undervoltage condition.
PMOD—Power Mode Enable. A value of 1 allows the DS2784 to enter Sleep mode when DQ is low for tSLEEP. A
value of 0 disables DQ related transitions to Sleep mode.
8 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
RNAOP—Read Net Address Op Code. A value of 0 selects 33h as the op code value for the Read Net Address
command. A value of 1 selects 39h as the Read Net Address opcode value.
0—Reserved bit, must be programmed to 0 for proper operation.
PSPIO—Power-Switch PIO Enable. A value of 1 enables the PIO pin as a power-switch input. A value of 0 disables
the power-switch input function on PIO pin. This control is independent of the PSDQ state.
PSDQ—Power-Switch DQ Enable. A value of 1 enables the DQ pin as a power-switch input. A value of 0 disables
the power-switch input function on DQ pin. This control is independent of the PSPIO state.
X—Reserved Bit.
Li+ PROTECTION CIRCUITRY
During Active mode, the DS2784 constantly monitors SNS, VIN, and VPLS to protect the battery from overvoltage
(overcharge), undervoltage (overdischarge), and excessive charge and discharge currents (overcurrent, short
circuit). Table 1 summarizes the conditions that activate the protection circuit, the response of the DS2784, and the
thresholds that release the DS2784 from a protection state.
Table 1. Li+ Protection Conditions and DS2784 Responses
ACTIVATION
CONDITION
THRESHOLD
DELAY
RESPONSE(2)
Overvoltage
VIN > VOV
tOVD
CC Off
Undervoltage
VIN < VUV
tUVD
CC Off, DC Off,
Sleep Mode
RELEASE THRESHOLD
VIN < VCE or (VSNS > 1.6mV
and VIN < VOV)
(3)
VPLS > VIN
(charger connected)
(4)
Overcurrent, Charge
VSNS < VCOC
tOCD
CC Off, DC Off
VPLS < VDD - VTP
Overcurrent, Discharge
VSNS > VDOC
tOCD
DC Off
VPLS > VDD - VTP
(5)
DC Off
VPLS > VDD - VTP
(5)
Short Circuit
VSNS > VSC
tSCD
(charger removed)
(load removed)
(load removed)
Note 1:
Note 2:
All voltages are with respect to VSS.
CC pin driven to VOLCC (VDD) for CC off response. DC pin driven to VOLDC (VSS) for DC off response.
Note 3:
Note 4:
If VIN < VUV when charger connection is detected, release is delayed until VIN ≥ VUV. The recovery charge path provides an internal
current limit (IRC) to safely charge the battery.
With test current I flowing from PLS to VSS (pulldown on PLS) enabled.
Note 5:
With test current I
TST
TST
flowing from VDD to PLS (pullup on PLS).
Overvoltage. If the voltage on VIN exceeds the overvoltage threshold (VOV) for a period longer than overvoltage
delay (tOVD), the CC pin is driven low to shut off the external-charge FET, and the OV flag in the protection register
is set. The DC output remains high during overvoltage to allow discharging. When VIN falls below the charge enable
threshold, VCE, the DS2784 turns the charge FET on by driving CC high. The DS2784 drives CC high before
VIN < VCE if a discharge condition persists with VSNS ≥ 1.6mV and VIN < VOV.
Undervoltage. If VIN drops below the undervoltage threshold (VUV) for a period longer than undervoltage delay
(tUVD), the DS2784 shuts off the charge and discharge FETs and sets the UV flag in the protection register. If UVEN
is set, the DS2784 also enters Sleep mode. The DS2784 provides a current-limited recovery charge path (IRC) from
PLS to VDD to gently charge severely depleted cells. The recovery charge path is enabled when
0 ≤ VDD < (VOV - 100mV). Once VDD reaches 2.45V (typ), the DS2784 returns to normal operation and begins
monitoring VIN. Once VIN > VUV, the DS2784 transitions from Sleep to Active mode and the CC and DC outputs are
driven high to turn on the charge and discharge FETs.
Overcurrent, Charge Direction (COC). Charge current develops a negative voltage on VSNS with respect to VSS. If
VSNS is less than the charge overcurrent threshold (VCOC) for a period longer than overcurrent delay (tOCD), the
9 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
DS2784 shuts off both external FETs and sets the COC flag in the protection register. The charge current path is
not re-established until the voltage on the PLS pin drops below VDD - VTP. The DS2784 provides a pulldown current
(ITST) from PLS to VSS to pull PLS down in order to detect the removal of the offending charge current source.
Overcurrent, Discharge Direction (DOC). Discharge current develops a positive voltage on VSNS with respect to
VSS. If VSNS exceeds the discharge overcurrent threshold (VDOC) for a period longer than tOCD, the DS2784 shuts off
the external discharge FET and sets the DOC flag in the protection register. The discharge current path is not reestablished until the voltage on PLS rises above VDD - VTP. The DS2784 provides a test current (ITST) from VDD to
PLS to pull PLS up in order to detect the removal of the offending low-impedance load.
Short Circuit. If VSNS exceeds short-circuit threshold VSC for a period longer than short-circuit delay (tSCD), the
DS2784 shuts off the external discharge FET and sets the DOC flag in the protection register. The discharge
current path is not re-established until the voltage on PLS rises above VDD - VTP. The DS2784 provides a test
current of value (ITST) from VDD to PLS to pull PLS up in order to detect the removal of the short circuit.
Figure 2. Li+ Protection Circuitry Example Waveforms
Summary. All the protection conditions previously described are logic ANDed to affect the CC and DC outputs.
CC =
(Overvoltage) AND (Undervoltage) AND (Overcurrent, Charge Direction)
AND (Protection Register Bit CE)
DC =
(Undervoltage) AND (Overcurrent, Either Direction) AND (Short Circuit)
AND (Protection Register Bit DE )
PROTECTION REGISTER FORMAT
The protection register reports events detected by the Li+ safety circuit on bits 2 to 7. Bits 0 and 1 are used to
disable the charge and discharge FET gate drivers. Bits 2 to 7 are set by internal hardware only. Bits 2 and 3 are
cleared by hardware only. Bits 4 to 7 are cleared by writing the register with a 0 in the bit position of interest. Writing
10 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
a 1 to bits 4 to 7 has no effect on the register. Bits 0 and 1 are set on power-up and a transition from Sleep to
Active modes. While in Active mode, these bits can be cleared to disable the FET gate drive of either or both FETs.
Setting these bits only turns on the FETs if there are no protection faults.
ADDRESS 00h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
OV
UV
COC
DOC
CC
DC
CE
DE
OV—Overvoltage Flag. OV is set to indicate that an overvoltage condition has been detected. The voltage on VIN
has persisted above the VOV threshold for tOV. OV remains set until written to a 0 or cleared by a power-on reset or
transition to Sleep mode.
UV—Undervoltage Flag. UV is a read-only mirror of the UVF flag located in the status register. UVF is set to
indicate that VIN < VUV . The UVF bit must be written to 0 to clear UV and UVF.
COC—Charge Overcurrent Flag. COC is set to indicate that an overcurrent condition has occurred during a charge.
The sense-resistor voltage has persisted above the VCOC threshold for tOC. COC remains set until written to a 0,
cleared by a power-on reset, or transition to Sleep mode.
DOC—Discharge Overcurrent Flag. DOC is set to indicate that an overcurrent condition has occurred during a
discharge. The sense-resistor voltage has persisted above the VDOC threshold for tOC. DOC remains set until written
to a 0, cleared by a power-on reset, or transition to Sleep mode.
CC—Charge Control Flag. CC indicates the logic state of the CC pin driver. CC flag is set to indicate CC high. CC
flag is cleared to indicate CC low. CC flag is read only.
DC—Discharge Control Flag. DC indicates the logic state of the DC pin driver. DC flag is set to indicate DC high.
DC flag is cleared to indicate DC low. DC flag is read only.
CE—Charge Enable Bit. CE must be set to allow the CC pin to drive the charge FET to the on state. CE acts as an
enable input to the safety circuit. If all safety conditions are met AND CE is set, the CC pin drives to VCP. If CE is
cleared, the CC pin is driven low to disable the charge FET.
DE—Discharge Enable Bit. DE must be set to allow the DC pin to drive the discharge FET to the on state. DE acts
as an enable input to the safety circuit. If all safety conditions are met AND DE is set, the DC pin drives to VCP. If
DE is cleared, the DC pin is driven low to disable the charge FET.
PROTECTOR THRESHOLD REGISTER FORMAT
The 8-bit threshold register consists of bit fields for setting the overvoltage threshold, charge overcurrent threshold,
discharge overcurrent threshold, and short-circuit threshold for the protection circuit.
ADDRESS 7Fh
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
VOV4
VOV3
VOV2
VOV1
VOV0
SC0
OC1
OC0
11 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Table 2. VOV Threshold
VOV BIT FIELD
VOV
VOV BIT FIELD
VOV
00000
4.248
10000
4.404
00001
4.258
10001
4.414
00010
4.268
10010
4.424
00011
4.277
10011
4.434
00100
4.287
10100
4.443
00101
4.297
10101
4.453
00110
4.307
10110
4.463
00111
4.316
10111
4.473
01000
4.326
11000
4.482
01001
4.336
11001
4.492
01010
4.346
11010
4.502
01011
4.356
11011
4.512
01100
4.365
11100
4.522
01101
4.375
11101
4.531
01110
4.385
11110
4.541
01111
4.395
11111
4.551
Table 3. COC, DOC Threshold
OC[1:0] BIT FIELD
VCOC (mV)
VDOC (mV)
00
-23.5
35.5
01
-36
48
10
-48
72
11
-72
96
Table 4. SC Threshold
SC0 BIT FIELD
VSC (mV)
0
150
1
300
VOLTAGE MEASUREMENT
Battery voltage is measured every 440ms on the VIN pin with respect to VSS. Measurements have a 0 to 4.99V
range and a 4.88mV resolution. The value is stored in the voltage register in two’s complement form and is updated
every 440ms. Voltages above the maximum register value are reported at the maximum value; voltages below the
minimum register value are reported at the minimum value.
VOLTAGE REGISTER FORMAT
MSB—ADDRESS 0Ch
S
29
28
27
MSb
26
25
LSB—ADDRESS 0Dh
24
23
LSb
22
MSb
21
20
X
X
X
X
X
LSb
Units: 4.886mV
“S”: Sign Bit(s), “X”: Reserved
12 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
TEMPERATURE MEASUREMENT
The DS2784 uses an integrated temperature sensor to measure battery temperature with a resolution of 0.125°C.
Temperature measurements are updated every 440ms and placed in the temperature register in two’s complement
form.
TEMPERATURE REGISTER FORMAT
MSB—ADDRESS 0Ah
S
29
28
27
26
25
LSB—ADDRESS 0Bh
24
MSb
23
LSb
22
21
20
X
X
X
X
MSb
X
LSb
Units: 0.125°C
“S”: Sign Bit(s), “X”: Reserved
Note: Temperature and battery voltage (VIN) are measured using the same ADC. Therefore, measurements are a 220ms average updated
every 440ms.
CURRENT MEASUREMENT
The DS2784 continually measures the current flow into and out of the battery by measuring the voltage drop across
a low-value current-sense resistor, RSNS. The voltage-sense range between SNS and VSS is ±51.2mV. The input
linearly converts peak-signal amplitudes up to 102.4mV as long as the continuous signal level (average over the
conversion cycle period) does not exceed ±51.2mV. The ADC samples the input differentially at 18.6kHz and
updates the current register at the completion of each conversion cycle (3.52s). Charge currents above the
maximum register value are reported as 7FFFh. Discharge currents below the minimum register value are reported
as 8000h.
CURRENT REGISTER FORMAT
MSB—ADDRESS 0Eh
S
214
213
212
211
210
LSB—ADDRESS 0Fh
29
MSb
28
LSb
27
26
25
24
23
22
21
MSb
20
LSb
“S”: Sign Bit(s)
Units: 1.5625μV/RSNS
The average current register reports an average current level over the preceding 28s. The register value is updated
every 28s in two’s complement form, and represents an average of the eight preceding current register values.
AVERAGE CURRENT REGISTER FORMAT
MSB—ADDRESS 08h
S
214
MSb
“S”: Sign Bit(s)
213
212
211
210
LSB—ADDRESS 09h
29
28
LSb
27
MSb
26
25
24
23
22
21
20
LSb
Units: 1.5625μV/RSNS
CURRENT OFFSET CORRECTION
Every 1024th conversion, the ADC measures its input offset to facilitate offset correction. Offset correction occurs
approximately once per hour. The resulting correction factor is applied to the subsequent 1023 measurements.
During the offset correction conversion, the ADC does not measure the sense-resistor signal. A maximum error of
1/1024 in the accumulated current register (ACR) is possible; however, to reduce the error, the current
13 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
measurement made just prior to the offset conversion is retained in the current register and is substituted for the
dropped current measurement in the current accumulation process. Therefore, the accumulated current error due
to offset correction is typically much less than 1/1024.
CURRENT OFFSET BIAS
The current offset bias (COB) value allows a programmable offset value to be added to raw current measurements.
The result of the raw current measurement plus COB is displayed as the current measurement result in the current
register, and is used for current accumulation. COB can be used to correct for a static offset error, or can be used
to intentionally skew the current results and, therefore, the current accumulation.
Read and write access is allowed to COB. Whenever the COB is written, the new value is applied to all subsequent
current measurements. COB can be programmed in 1.56μV steps to any value between +198.1µV and -199.7µV.
The COB value is stored as a two’s complement value in EEPROM. The COB is loaded on power-up from
EEPROM memory. The factory default value is 00h.
The difference between the CAB and COB is that the CAB is not subject to current blanking. Offset currents
between 100µV and -25µV are not accumulated if the offset is made by the COB. Offset currents between 100µV
and -25µV are accumulated if they are made by the CAB.
CURRENT OFFSET BIAS REGISTER FORMAT
ADDRESS 7Bh
S
26
25
24
MSb
23
22
21
20
LSb
“S”: Sign Bit(s)
Units: 1.56μV/RSNS
CURRENT BLANKING
The current blanking feature modifies current measurement result prior to being accumulated in the ACR. Current
blanking occurs conditionally when a current measurement (raw current + COBR) falls in one of two defined
ranges. The first range prevents charge currents less than 100μV from being accumulated. The second range
prevents discharge currents less than 25μV in magnitude from being accumulated. Charge current blanking is
always performed; however, discharge current blanking must be enabled by setting the NBEN bit in the control
register. See the register description for additional information.
14 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
CURRENT MEASUREMENT CALIBRATION
The DS2784’s current measurement gain can be adjusted through the RSGAIN register, which is factory calibrated
to meet the data sheet-specified accuracy. RSGAIN is user accessible and can be reprogrammed after module or
pack manufacture to improve the current measurement accuracy. Adjusting RSGAIN can correct for variation in an
external sense resistor’s nominal value, and allows the use of low-cost, nonprecision, current-sense resistors.
RSGAIN is an 11-bit value stored in 2 bytes of the parameter EEPROM memory block. The RSGAIN value adjusts
the gain from 0 to 1.999 in steps of 0.001 (precisely 2-10). The user must program RSGAIN cautiously to ensure
accurate current measurement. When shipped from the factory, the gain calibration value is stored in two separate
locations in the parameter EEPROM block: RSGAIN, which is reprogrammable, and FRSGAIN, which is read only.
RSGAIN determines the gain used in the current measurement. The FRSGAIN value is provided to preserve the
factory calibration value only and is not used to calibrate the current measurement. The 16-bit FRSGAIN value is
readable from addresses B0h and B1h.
CURRENT MEASUREMENT GAIN REGISTER FORMAT
MSB—ADDRESS 78h
X
X
X
X
210
X
LSB—ADDRESS 79h
29
MSb
28
27
LSb
MSb
26
25
24
23
22
21
20
LSb
-10
Units: 2
SENSE RESISTOR TEMPERATURE COMPENSATION
The DS2784 can of temperature compensate the current-sense resistor to correct for variation in a sense resistor’s
value overtemperature. The DS2784 is factory programmed with the sense-resistor temperature coefficient, RSTC,
set to zero, which turns off the temperature compensation function. RSTC is user accessible and can be
reprogrammed after module or pack manufacture to improve the current accuracy when using a high-temperature
coefficient current-sense resistor. RSTC is an 8-bit value stored in the parameter EEPROM memory block. The
RSTC value sets the temperature coefficient from 0 to +7782ppm/ºC in steps of 30.5ppm/ºC. The user must
program RSTC cautiously to ensure accurate current measurement.
Temperature compensation adjustments are made when the temperature register crosses 0.5oC boundaries. The
temperature compensation is most effective with the resistor placed as close as possible to the VSS terminal. This
optimizes thermal coupling of the resistor to the on-chip temperature sensor.
SENSE RESISTOR TEMPERATURE COMPENSATION REGISTER FORMAT
ADDRESS 7Ah
27
26
25
24
MSb
23
22
21
20
LSb
Units: 30.5ppm/ºC
CURRENT ACCUMULATION
Current measurements are internally summed, or accumulated, at the completion of each conversion period and
the results are stored in the ACR. The accuracy of the ACR is dependent on both the current measurement and the
conversion time base. The ACR has a range of 0 to 409.6mVh with an LSb of 6.25μVh. Additional registers hold
fractional results of each accumulation to avoid truncation errors. The fractional result bits are not user accessible.
Accumulation of charge current above the maximum register value is reported at the maximum value; conversely,
accumulation of discharge current below the minimum register value is reported at the minimum value.
Charge currents (positive current register values) less than 100μV are not accumulated in order to mask the effect
of accumulating small positive offset errors over long periods. This limits the minimum charge current, for coulombcounting purposes, to 5mA for RSNS = 0.020Ω and 20mA for RSNS = 0.005Ω.
15 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Read and write access is allowed to the ACR. The ACR must be written MSB first then LSB. Whenever the ACR is
written, the fractional accumulation result bits are cleared. The write must be completed in 3.5s (one ACR update
period). A write to the ACR forces the ADC to perform an offset correction conversion and update the internal offset
correction factor. The current measurement and accumulation begin with the second conversion following a write to
the ACR.
The ACR value is backed up to EEPROM in case of power loss. The ACR value is recovered from EEPROM on
power-up. See Table 8 for specific address location and backup frequency.
ACCUMULATED CURRENT REGISTER FORMAT
MSB—ADDRESS 10h
215
214
213
212
211
210
LSB—ADDRESS 11h
29
MSb
28
27
26
LSb
MSb
25
24
23
22
21
20
LSb
Units: 6.25μVh/RSNS
Table 5. Resolution and Range vs. Sense Resistor
RSNS
VSS - VSNS
20mΩ
15mΩ
10mΩ
5mΩ
Current Resolution
1.5625μV
78.13μA
104.2μA
156.3μA
312.5μA
Current Range
±51.2mV
±2.56A
±3.41A
±5.12A
±10.24A
ACR Resolution
6.25μVh
312.5μAh
416.7μAh
625μAh
1.250mAh
409.6mVh
20.48Ah
27.31Ah
40.96Ah
81.92Ah
ACR Range
ACCUMULATION BIAS
In some designs a systematic error or an application preference requires the application of an arbitrary bias to the
current accumulation process. The current accumulation bias register (CAB) allows a user-programmed constant
positive or negative polarity bias to be included in the current accumulation process. The value in CAB can be used
to estimate battery currents that do not flow through the sense resistor, estimate battery self-discharge or estimate
current levels below the current measurement resolution. The user programmed two’s complement value, with bit
weighting the same as the current register, is added to the ACR once per current conversion cycle. The CAB is
loaded on power-up from EEPROM memory.
The difference between the CAB and COB is that the CAB is not subject to current blanking. Offset currents
between 100µV and -25µV are not accumulated if the offset is made by the COB. Offset currents between 100µV
and -25µV are accumulated if they are made by the CAB.
CURRENT ACCUMULATION BIAS REGISTER FORMAT
ADDRESS 61h
S
26
25
24
MSb
23
22
21
20
LSb
“S”: Sign Bit
Units: 1.5625μV/RSNS
16 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
CAPACITY ESTIMATION ALGORITHM
Remaining capacity estimation uses real-time measured values, stored parameters describing the cell
characteristics, and application operating limits. Figure 2 describes the algorithm inputs and outputs.
Figure 2. Top-Level Algorithm Diagram
Voltage
(R)
Temperature
(R)
Current
(R)
Accumulated
Current (ACR) (R/W)
FULL(T)
(R)
Active Empty (T)
(R)
Standby Empty (T)
(R)
Capacity Look-up
Available Capacity Calculation
ACR Housekeeping
Average Current (R)
Age Estimator
Remaining Active Absolute
Capacity (RAAC) mAh
Learn Function
Remaining Standby Absolute
Capacity (RSAC) mAh
(R)
Cell
Model
Parameters
(EEPROM)
Remaining Active Relative
Capacity (RARC) %
(R)
(R)
Remaining Standby Relative
Capacity (RSRC) %
(R)
Aging Cap (AC)
(2 bytes EE)
User Memory (EEPROM)
Age Scalar (AS)
(1 bytes EE)
16 bytes
Sense Resistor’
(RSNSP) (1byte EE)
Charge Voltage
(VCHG) (1 byte EE)
Min Chg Current
(IMIN) (1 byte EE)
Empty Voltage
(VAE) (1 byte EE)
Empty Current (IAE)
(1 byte EE)
MODELING CELL CHARACTERISTICS
To achieve reasonable accuracy in estimating remaining capacity, the cell performance characteristics
overtemperature, load current, and charge-termination point must be considered. Since the behavior of Li+ cells is
nonlinear, these characteristics must be included in the capacity estimation to achieve an acceptable level of
accuracy in the capacity estimation. The FuelPack™ method used in the DS2784 is described in general in
Application Note 131: Lithium-Ion Cell Fuel Gauging with Dallas Semiconductor Battery Monitor ICs. To facilitate
efficient implementation in hardware, a modified version of the method outlined in AN131 is used to store cell
characteristics in the DS2784. Full and empty points are retrieved in a lookup process which retraces a piece-wise
linear model consisting of three model curves named full, active empty, and standby empty. Each model curve is
constructed with 5-line segments, numbered 1 through 5. Above 40°C, the segment 5 model curves extend
infinitely with zero slope, approximating the nearly flat change in capacity of Li+ cells at temperatures above 40°C.
Segment 4 of each model curves originates at +40C on its upper end and extends downward in temperature to the
junction with segment 3. Segment 3 joins with segment 2, which in turn joins with segment 1. Segment 1 of each
model curve extends from the junction with segment 2 to infinitely colder temperatures. The three junctions or
breakpoints that join the segments (labeled TBP12, TBP23, and TBP34 in Figure 3) are programmable in 1°C
increments
from
-128°C to +40°C. The slope or derivative for segments 1, 2, 3, and 4 are also programmable over a range of 0 to
15,555ppm, in steps of 61ppm.
FuelPack is a trademark of Dallas Semiconductor, a wholly owned subsidiary of Maxim Integrated Products, Inc.
17 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Figure 3. Cell Model Example Diagram
SEGMENT 1
SEG. 2
100%
SEG. 3
SEG. 4
SEG. 5
FULL
DERIVATIVE
[PPM/°C]
ACTIVE
EMPTY
CELL
CHARACTERIZATION
DATA POINTS
STANDBY
EMPTY
TBP12
TBP23
TBP34
40°C
Full—The full curve defines how the full point of a given cell varies over temperature for a given charge termination.
The application’s charge termination method should be used to determine the table values. The DS2784
reconstructs the full line from the cell characteristic table to determine the full capacity of the battery at each
temperature. Reconstruction occurs in one-degree temperature increments.
Active Empty—The active-empty curve defines the variation of the active-empty point over temperature. The
active-empty point is defined as the minimum voltage required for system operation at a discharge rate based on a
high-level load current (one that is sustained during a high-power operating mode). This load current is
programmed as the active-empty current (IAE), and should be a 3.5s average value to correspond to values read
from the current register. The specified minimum voltage, or active empty voltage (VAE), should be a 220ms
average value to correspond to the values read from the voltage register. The DS2784 reconstructs the active
empty line from the cell characteristic table to determine the active empty capacity of the battery at each
temperature. Reconstruction occurs in one-degree temperature increments.
Standby Empty—The standby-empty curve defines the variation of the standby-empty point over temperature. The
standby-empty point is defined as the minimum voltage required for standby operation at a discharge rate dictated
by the application standby current. In typical handheld applications, standby empty represents the point that the
battery can no longer support DRAM refresh and thus the standby voltage is set by the minimum DRAM voltagesupply requirements. In other applications, standby empty can represent the point that the battery can no longer
support a subset of the full application operation, such as games or organizer functions. The standby load current
and voltage are used for determining the cell characteristics but are not programmed into the DS2784. The DS2784
reconstructs the standby-empty line from the cell characteristic table to determine the standby-empty capacity of
the battery at each temperature. Reconstruction occurs in one-degree temperature increments.
CELL MODEL CONSTRUCTION
The model is constructed with all points normalized to the fully charged
state at +40°C. All values are stored in the cell parameter EEPROM block.
The +40°C full value is stored in µVhr with an LSB of 6.25µVhr. The +40°C
active empty value is stored as a percentage of +40°C full with a resolution
of 2-10. Standby empty at +40°C is, by definition, zero and, therefore, no
storage is required. The slopes (derivatives) of the 4 segments for each
18 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
model curve are stored in the cell parameter EEPROM block as ppm/°C. The breakpoint temperatures of each
segment are stored there also (see Application Note 3584: Storing Battery Fuel Gauge Parameters in DS2780 for
more details on how values are stored). An example of data stored in this manner is shown in Table 6.
Table 6. Example Cell Characterization Table (Normalized to +40°C)
Manufacturer’s Rated Cell Capacity: 1000mAh
Charge Voltage: 4.2V
Termination Current: 50mA
Active Empty (V): 3.0V
Active Empty (I): 300mA
Sense Resistor: 0.020Ω
Segment
Breakpoints
Full
Active Empty
Standby Empty
TBP12
TBP23
TBP34
-12°C
0°C
18°C
+40°C
Nominal
(mAh)
1051
Seg. 1
ppm/°C
Seg. 2
ppm/°C
Seg. 3
ppm/°C
Seg. 4
ppm/°C
3601
2380
1404
3113
1099
427
1163
671
244
854
305
183
Figure 4. Lookup Function Diagram
CELL MODEL
PARAMETERS
LOOKUP
(EEPROM)
FUNCTION
FULL(T)
TEMPERATURE
AE(T)
SE(T)
*
*
*
*
See Result Registers section for a description of these registers.
APPLICATION PARAMETERS
In addition to cell model characteristics, several application parameters are needed to detect the full and empty
points, as well as calculate results in mAh units.
Sense Resistor Prime (RSNSP[1/Ω])—RSNSP stores the value of the sense resistor for use in computing the absolute
capacity results. The resistance is stored as a 1-byte conductance value with units of mhos (1/Ω). RSNSP supports
resistor values of 1Ω to 3.922mΩ. RSNS is located in the parameter EEPROM block.
RSNSP = 1/RSNS (units of mhos; 1/Ω)
Charge Voltage (VCHG)—VCHG stores the charge voltage threshold used to detect a fully charged state. The
voltage is stored as a 1-byte value with units of 19.5mV and can range from 0V to 4.978V. VCHG should be set
marginally less than the cell voltage at the end of the charge cycle to ensure reliable charge termination detection.
VCHG is located in the parameter EEPROM block.
19 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Minimum Charge Current (IMIN)—IMIN stores the charge current threshold used to detect a fully charged state. It
is stored as a 1-byte value with units of 50μV (IMIN x RSNS) and can range from 0 to 12.75mV. Assuming RSNS =
20mΩ, IMIN can be programmed from 0mA to 637.5mA in 2.5mA steps. IMIN should be set marginally greater than
the charge current at the end of the charge cycle to ensure reliable charge termination detection. IMIN is located in
the parameter EEPROM block.
Active Empty Voltage (VAE)—VAE stores the voltage threshold used to detect the active empty point. The value
is stored in 1-byte with units of 19.5mV and can range from 0V to 4.978V. VAE is located in the parameter
EEPROM block. See the Cell Characteristics section for more information.
Active Empty Current (IAE)—IAE stores the discharge current threshold used to detect the active empty point.
The unsigned value represents the magnitude of the discharge current and is stored in 1-byte with units of 200μV
and can range from 0 to 51.2mV. Assuming RSNS = 20mΩ, IAE can be programmed from 0mA to 2550mA in 10mA
steps. IAE is located in the Parameter EEPROM block. See the Cell Model Construction section for more
information.
Aging Capacity (AC)—AC stores the rated cell capacity, which is used to estimate the decrease in battery
capacity that occurs during normal use. The value is stored in 2 bytes in the same units as the ACR (6.25μVh).
When set to the manufacturer’s rated cell capacity the aging estimation rate is approximately 2.4% per 100 cycles
of equivalent full capacity discharges. Partial discharge cycles are added to form equivalent full capacity
discharges. The default aging estimation results in 88% capacity after 500 equivalent cycles. The aging estimation
rate can be adjusted by setting the AC to a value other than the cell manufacturer’s rating. Setting AC to a lower
value, accelerates the aging estimation rate. Setting AC to a higher value, retards the aging estimation rate. The
AC is located in the parameter EEPROM block.
Age Scalar (AS)—AS adjusts the cell capacity estimation results downward to compensate for aging. The AS is a
1-byte value that has a range of 49.2% to 100%. The LSB is weighted at 0.78% (precisely 2-7). A value of 100%
(128 decimal or 80h) represents an unaged battery. A value of 95% is recommended as the starting AS value at the
time of pack manufacture to allow the learning of a larger capacity on batteries that have an initial capacity greater
than the rated cell capacity programmed in the cell characteristic table. The AS is modified by aging estimation
introduced under aging capacity and by the capacity-learn function. The host system has read and write access to
the AS, however caution should exercised when writing it to ensure that the cumulative aging estimate is not
overwritten with an incorrect value. The AS is automatically saved to EEPROM (see Table 7 for details). The
EEPROM value is recalled on power-up.
Full capacity estimation based on the learn function is more accurate than the cycle-count-based estimation. The
learn function reflects the current performance of the cell. Cycle count based estimation is an approximation
derived from the manufacturer’s recommendation for a typical cell. Batteries are typically considered worn-out when
the full capacity reaches 80% of the rated capacity, therefore, the AS value is not required to range to 0%. It is
clamped to 50% (64d or 40h). If a value of 50% is read from the AS, the host should prompt the user to initiate a
learning cycle.
CAPACITY ESTIMATION OPERATION
Aging Estimation
As discussed above, the AS register value is adjusted occasionally based on cumulative discharge. As the ACR
register decrements during each discharge cycle, an internal counter is incremented until equal to 32 times the AC.
The AS is then decremented by one, resulting in a decrease of the scaled full battery capacity by 0.78%
(approximately 2.4% per 100 cycles). See the AC register description above for recommendations on customizing
the age-estimation rate.
Learn Function
Since Li+ cells exhibit charge efficiencies near unity, the charge delivered to a Li+ cell from a known empty point to
a known full point is a dependable measure of the cell capacity. A continuous charge from empty to full results in a
learn cycle. First, the active empty point must be detected. The learn flag (LEARNF) is set at this point. Then, once
charging starts, the charge must continue uninterrupted until the battery is charged to full. Upon detecting full,
20 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
LEARNF is cleared, the charge to full (CHGTF) flag is set, and the age scalar (AS) is adjusted according to the
learned capacity of the cell.
ACR Housekeeping
The ACR value is adjusted occasionally to maintain the coulomb count within the model curve boundaries. When
the battery is charged to full (CHGTF set), the ACR is set equal to the age scaled full lookup value at the present
temperature. If a learn cycle is in progress, correction of the ACR value occurs after the age scalar (AS) is updated.
When an empty condition is detected (LEARNF and/or AEF set), the ACR adjustment is conditional:
ƒ If the AEF is set and the LEARNF is not set, then the active-empty point was not detected. The battery is likely
below the active-empty capacity of the model. The ACR is set to the active-empty model value at present temp
only if it is greater than the active-empty model value at present temp.
ƒ If the AEF is set, the LEARNF is not set, and the ACR is below the active-empty model value at present temp
the ACR is NOT updated.
ƒ If the LEARNF is set, then the battery is at the active-empty point and the ACR is set to the active-empty model
value.
Full Detect
Full detection occurs when the voltage (V) readings remain continuously above the charge voltage (VCHG)
threshold for the duration of two average current (IAVG) readings, and both IAVG readings are below terminating
current (IMIN). The two consecutive IAVG readings must also be positive and nonzero (> 16 LSB). This ensures
that removing the battery from the charger does not result in a false detection of full. Full detect sets the charge to
full (CHGTF) bit in the status register.
Active-Empty Point Detect
Active-empty point detection occurs when the voltage register drops below the VAE threshold AND the two
previous current readings are above IAE. This captures the event of the battery reaching the active-empty point.
Note that the two previous current readings must be negative and greater in magnitude than IAE, that is, a larger
discharge current than specified by the IAE threshold. Qualifying the voltage level with the discharge rate ensures
that the active-empty point is not detected at loads much lighter than those used to construct the model. Also, the
active-empty point must not be detected when a deep discharge at a very light load is followed by a load greater
than IAE. Either case would cause a learn cycle on the following charge to include part of the standby capacity in
the measurement of the active capacity. Active-empty point detection sets the learn flag (LEARNF) bit in the status
register. Do not confuse the active-empty point with the active-empty flag. The active-empty flag is set only when
the VAE threshold is passed.
STATUS REGISTER FORMAT
The status register contains bits that report the device status. All bits are set internally. The CHGTF, AEF, SEF, and
LEARNF bits are read only. The UVF and PORF bits can be cleared by writing a zero to the bit locations.
ADDRESS 01h
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CHGTF
AEF
SEF
LEARNF
X
UVF
PORF
X
CHGTF—Charge-Termination Flag. CHGTF is set to indicate that the voltage and average current register values
have persisted above the VCHG and below the IMIN thresholds sufficiently long to detect a fully charged condition.
CHGF is cleared when RARC is less than 90%. CHGF is read only.
AEF—Active-Empty Flag. AEF is set to indicate that the battery is at or below the active-empty point. AEF is set
when the voltage register value is less than the VAE threshold. AEF is cleared when RARC is greater than 5%.
AEF is read only.
SEF—Standby-Empty Flag. SEF is set to indicate RSRC is less than 10%. SEF is cleared when RSRC is greater
than 15%. SEF is read only.
21 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
22 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
LEARNF—Learn Flag. LEARNF indicates that the current charge cycle can be used to learn the battery capacity.
LEARNF is set when the active-empty point is detected. This occurs when the voltage register value drops below
the VAE threshold AND the two previous current register values were negative and greater in magnitude than the
IAE threshold. See the Active-Empty Point Detect section for additional information. LEARNF is cleared when any
of the following occur:
1) Learn cycle completes (CHGTF set).
2) Current register value becomes negative indicating discharge current flow.
3) ACR = 0
4) ACR value is written or recalled from EEPROM.
5) Sleep mode is entered.
LEARNF is read only.
UVF—Undervoltage Flag. UVF is set to indicate that the voltage measurement of the VIN pin is less than VUV, and
must be written to a 0 to allow subsequent undervoltage events to be reported. UVF is not cleared internally.
Writing UVF to 0 is effective only when VIN is greater or equal to VUV, otherwise, UV remains set due to the
persistent undervoltage condition. UVF is set on power-up.
PORF—Power-On Reset Flag. PORF is set to indicate initial power-up. PORF is not cleared internally. The user
must write this flag value to a 0 to use it to indicate subsequent power-up events. If PORF indicates a power-on
reset, the ACR could be misaligned with the actual battery state of charge. The system can request a charge to full
to synchronize the ACR with the battery charge state. PORF is read/write-to-zero.
X—Reserved Bits.
RESULT REGISTERS
The DS2784 processes measurement and cell characteristics on a 3.5s interval and yields seven result registers.
The result registers are sufficient for direct display to the user in most applications. The host system can produce
customized values for system use or user display by combining measurement, result and user EEPROM values.
FULL(T) [ ]—The full capacity of the battery at the present temperature is reported normalized to the 40°C full
value. This 15-bit value reflects the cell model Full value at the given temperature. FULL(T) reports values between
100% and 50% with a resolution of 61ppm (precisely 2-14). The register is clamped to a maximum value of 100%
even though the register format permits values greater than 100%.
Active Empty, AE(T) [ ]—The active-empty capacity of the battery at the present temperature is reported
normalized to the 40°C full value. This 13-bit value reflects the cell model active-empty value at the given
temperature. AE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely 2-14).
Standby Empty, SE(T) [ ]—The standby-empty capacity of the battery at the present temperature is reported
normalized to the 40°C full value. This 13-bit value reflects the cell model standby-empty value at the current
temperature. SE(T) reports values between 0% and 49.8% with a resolution of 61ppm (precisely 2-14).
Remaining Active Absolute Capacity (RAAC) [mAh]—RAAC reports the remaining battery capacity available
under the current temperature conditions to the active-empty point in absolute units of milliamp-hours (mAhr).
RAAC is 16 bits.
23 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
MSB—ADDRESS 02h
215
214
213
212
211
210
LSB—ADDRESS 03h
29
MSb
28
27
26
LSb
MSb
25
24
23
22
21
20
LSb
Units:
1.6mAhr
Remaining Standby Absolute Capacity (RSAC) [mAh]—RSAC reports the remaining battery capacity available
under the current temperature conditions to the standby-empty point capacity in absolute units of milliamp-hours
(mAhr). RSAC is 16 bits.
MSB—ADDRESS 04h
215
214
213
212
211
210
LSB—ADDRESS 05h
29
MSb
28
27
26
LSb
MSb
25
24
23
22
21
20
LSb
Units:
1.6mAhr
Remaining Active Relative Capacity (RARC) [%]—RARC reports the remaining battery capacity available under
the current temperature conditions to the active-empty point in relative units of percent. RARC is 8 bits.
ADDRESS 06h
27
26
25
24
23
22
21
MSb
20
LSb
Units:
1%
Remaining Standby Relative Capacity (RSRC) [%]—RSRC reports the remaining battery capacity available
under the current temperature conditions to the standby-empty point capacity in relative units of percent. RSRC is 8
bits.
ADDRESS 07h
27
26
25
24
23
22
21
MSb
20
LSb
Units:
24 of 38
1%
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Calculation of Results
RAAC [mAh] = (ACR[mVh] - AE(T) * FULL40[mVh]) * RSNSP [mhos]
Note: RSNSP = 1/RSNS
RSAC [mAh] = (ACR[mVh] - SE(T) * FULL40[mVh]) * RSNSP [mhos]
Note: RSNSP = 1/RSNS
RARC [%] = 100% * (ACR[mVh] - AE(T) * FULL40[mVh]) /
{(AS * FULL(T) - AE(T)) * FULL40[mVh]}
RSRC [%] = 100%* (ACR[mVh] - SE(T) * FULL40[mVh]) /
{(AS * FULL(T) - SE(T)) * FULL40[mVh]}
SPECIAL FEATURE REGISTER FORMAT
All register bits are read and write accessible, with default values specified in each bit definition.
ADDRESS 15H
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
X
X
X
X
X
X
X
PIOB
PIOB—PIO Pin Sense and Control Bit. Writing a 0 to the PIOB bit activates the PIO pin open-drain output driver,
forcing the PIO pin low. Writing a 1 to PIOB disables the output driver, allowing the PIO pin to be pulled high or
used as an input. Reading PIOB returns the logic level forced on the PIO pin. Note that if the PIO pin is left floating
with PIOB set, a weak pulldown current source pulls the PIO pin to VSS. PIOB is set to a 1 on power-up. PIOB is
also set in Sleep mode to ensure the PIO pin is high-impedance in sleep mode.
Note: Do not write PIOB to 0 if PSPIO is enabled.
X—Reserved Bits.
EEPROM REGISTER
The EEPROM register provides access control of the EEPROM blocks. EEPROM blocks can be locked to prevent
alteration of data within the block. Locking a block disables write access to the block. Once a block is locked, it
cannot be unlocked. Read access to EEPROM blocks is unaffected by the lock/unlock status.
EEPROM REGISTER FORMAT
ADDRESS 1Fh
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
EEC
LOCK
X
X
X
X
BL1
BL0
EEC—EEPROM Copy Flag. A 1 in this read-only bit indicates that a Copy Data Function command is in progress.
While this bit is high, writes to EEPROM addresses are ignored. A 0 value in this bit indicates that data can be
written to unlocked EEPROM.
LOCK—EEPROM Lock Enable. When the lock bit is 0, the Lock Function command is ignored. Writing a 1 to this
bit enables the Lock Function command. After setting the lock bit the lock function command must be issued as the
next command, or else the lock bit is reset to 0. After the lock operation is completed, the lock bit is reset to 0. The
lock bit is a volatile R/W bit, initialized to 0 upon POR.
25 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
BL1—Parameter EEPROM Block 1 Lock Flag. A 1 in this read-only bit indicates that EEPROM block 1 (addresses
60h to 7Fh) is locked (read only) while a 0 indicates block 1 is unlocked (read/write).
BL0—User EEPROM Block 0 Lock Flag. A 1 in this read-only bit indicates that EEPROM block 0 (addresses 20h to
2Fh is locked (read only) while a 0 indicates block 0 is unlocked (read/write).
X – Reserved Bits.
MEMORY
The DS2784 has a 256-byte linear memory space with registers for instrumentation, status, and control, as well as
EEPROM memory blocks to store parameters and user information. Byte addresses designated as “Reserved”
typically return FFh when read. These bytes should not be written. Several byte registers are paired into two-byte
registers in order to store 16-bit values. The most significant byte (MSB) of the 16-bit value is located at the even
address and the least significant byte (LSB) is located at the next address (odd) byte. When the MSB of a two-byte
register is read, the MSB and LSB are latched simultaneously and held for the duration of the Read Data
command. This prevents updates to the LSB during the read ensuring synchronization between the two register
bytes. For consistent results, always read the MSB and the LSB of a two-byte register during the same read data
sequence.
EEPROM memory consists of nonvolatile (NV) EEPROM cells overlaying volatile shadow RAM. The read data and
write data protocols allow the 1-Wire interface to directly accesses the shadow RAM only. The Copy Data and
Recall Data Function commands transfer data between the EEPROM cells and the shadow RAM. In order to
modify the data stored in the EEPROM cells, data must be written to the shadow RAM and then copied to the
EERPOM. To verify the data stored in the EEPROM cells, the EEPROM data must be recalled to the shadow RAM
and then read from the shadow. After issuing the Copy Data Function command, access to the EEPROM block is
not available until the EEPROM copy completes, which takes 2ms typically (see tEEC in the Electrical Characteristics
table).
Figure 5. EEPROM Access via Shadow RAM
COPY
EEPROM
SERIAL
INTERFACE
WRITE
READ
SHADOW RAM
RECALL
USER EEPROM—BLOCK 0
A 16-byte user EEPROM memory (block 0, addresses 20h–2Fh) provides NV memory that is uncommitted to other
DS2784 functions. Accessing the user EEPROM block does not affect the operation of the DS2784. User EEPROM
is lockable; once locked, write access is not allowed. The battery pack or host system manufacturer can program
lot codes, date codes, and other manufacturing or warranty or diagnostic information and then lock it to safeguard
the data. User EEPROM can also store parameters for charging to support different size batteries in a host device
as well as auxiliary model data such as time to full charge estimation parameters.
PARAMETER EEPROM—BLOCK 1
Model data for the cells, as well as application operating parameters, are stored in the parameter EEPROM (block
1, addresses 60h–7Fh). The ACR (MSB and LSB) and AS registers are automatically saved to EEPROM when the
RARC result crosses 4% boundaries. This allows the DS2784 to be located outside the protection FETs.
26 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Table 7. Parameter EEPROM Memory Block
ADDRESS
(HEX)
60
61
62
63
64
65
66
67
68
69
DESCRIPTION
CONTROL—Control Register
AB— Accumulation Bias
AC—Aging Capacity MSB
AC—Aging Capacity LSB
VCHG—Charge Voltage
IMIN—Minimum Charge Current
VAE—Active-Empty Voltage
IAE—Active-Empty Current
Active Empty 40
RSNSP—Sense Resistor Prime
ADDRESS
(HEX)
70
71
72
73
74
75
76
77
78
79
6A
Full 40 MSB
7A
6B
6C
6D
6E
6F
Full 40 LSB
Full Segment 4 Slope
Full Segment 3 Slope
Full Segment 2 Slope
Full Segment 1 Slope
7B
7C
7D
7E
7F
27 of 38
DESCRIPTION
AE Segment 4 Slope
AE Segment 3 Slope
AE Segment 2 Slope
AE Segment 1 Slope
SE Segment 4 Slope
SE Segment 3 Slope
SE Segment 2 Slope
SE Segment 1 Slope
RSGAIN—Sense Resistor Gain MSB
RSGAIN—Sense Resistor Gain LSB
RSTC—Sense Resistor Temp
Coefficient
COB—Current Offset Bias
TBP34
TBP23
TBP12
Protector Threshold Register
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Table 8. Memory Map
ADDRESS (HEX)
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C to 1E
1F
20 to 2F
38 to 5F
60 to 7F
80 to AF
B0
B1
B2 to FF
DESCRIPTION
Protection Register
Status Register
RAAC MSB
RAAC LSB
RSAC MSB
RSAC LSB
RARC
RSRC
Average Current Register MSB
Average Current Register LSB
Temperature Register MSB
Temperature Register LSB
Voltage Register MSB
Voltage Register LSB
Current Register MSB
Current Register LSB
Accumulated Current Register MSB
Accumulated Current Register LSB
Accumulated Current Register LSB-1
Accumulated Current Register LSB-2
Age Scalar
Special Feature Register
Full MSB
Full LSB
Active-Empty MSB
Active-Empty LSB
Standby-Empty MSB
Standby-Empty LSB
Reserved
EEPROM Register
User EEPROM, Lockable, Block 0
Reserved
Parameter EEPROM, Lockable, Block 1
Reserved
Factory Gain RSGAIN MSB
Factory Gain RSGAIN LSB
Reserved
READ/WRITE
R/W
R/W
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/W *
R/W *
R
R
R/W *
R/W
R
R
R
R
R
R
—
R/W
R/W
—
R/W
—
R
R
—
* Register value is automatically saved to EEPROM during Active mode operation and recalled from EEPROM on
power-up.
28 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
AUTHENTICATION
Authentication is performed using a FIPS-180-compliant SHA-1 one-way hash algorithm on a 512-bit message
block. The message block consists of a 64-bit secret, a 64-bit challenge and 384 bits of constant data. Optionally,
the 64-bit net address replaces 64 of the 384 bits of constant data used in the hash operation. Contact Maxim for
details of the message block organization.
The host and the DS2784 both calculate the result based on the mutually known secret. The result of the hash
operation is known as the message authentication code (MAC) or message digest. The MAC is returned by the
DS2784 for comparison to the host’s MAC. Note that the secret is never transmitted on the bus and thus cannot be
captured by observing bus traffic. Each authentication attempt is initiated by the host system by providing a 64-bit
random challenge by the Write Challenge command. The host then issues the compute MAC or compute MAC with
ROM ID command. The MAC is computed per FIPS 180, and then returned as a 160-bit serial stream, beginning
with the least significant bit.
DS2784 AUTHENTICATION COMMANDS
WRITE CHALLENGE [0Ch]. This command writes the 64-bit challenge to the DS2784. The LSB of the 64-bit data
argument can begin immediately after the MSB of the command has been completed. If more than 64-bits are
written, the final value in the challenge register will be indeterminate. The Write Challenge command must be
issued prior to every Compute MAC or Compute Next Secret command for reliable results.
COMPUTE MAC WITHOUT ROM ID [36h]. This command initiates a SHA-1 computation without including the
ROM ID in the message block. Since the ROM ID is not used, this command allows the use of a master secret and
MAC response independent of the ROM ID. The DS2784 computes the MAC in tSHA after receiving the last bit of
this command. After the MAC computation is complete, the host must write 8 write-zero time slots and then issue
160 read-time slots to receive the 20-byte MAC. See Figure 9 for command timing.
COMPUTE MAC WITH ROM ID [35h]
This command is structured the same as the compute MAC without ROM ID, except that the ROM ID is included in
the message block. With the ROM ID unique to each DS2784 included in the MAC computation, the MAC is unique
to each token. See White Paper 4: Glossary of 1-Wire SHA-1 Terms, for more information. See Figure 9 for
command timing.
SHA-1-related commands used while authenticating a battery or peripheral device are summarized in Table 9 for
convenience. Four additional commands for clearing, computing, and locking of the secret are described in detail in
the following section.
Table 9. Authentication Function Commands
COMMAND
HEX
FUNCTION
Writes 64-bit challenge for SHA-1 processing. Required prior to
issuing Compute MAC and Compute Next Secret commands.
Write Challenge
0C
Compute MAC Without ROM ID
and Return MAC
36
Computes hash operation of the message block with logical 1s in
place of the ROM ID. Returns the 160-bit MAC.
Compute MAC With ROM ID and
Return MAC
35
Computes hash operation of the message block including the
ROM ID. Returns the 160-bit MAC.
29 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
SECRET MANAGEMENT FUNCTION COMMANDS
CLEAR SECRET [5Ah]. This command sets the 64-bit secret to all 0s (0000 0000 0000 0000h). The host must
wait tEEC for the DS2784 to write the new secret value to EEPROM. See Figure 12 for command timing.
COMPUTE NEXT SECRET WITHOUT ROM ID [30h]. This command initiates a SHA-1 computation of the MAC
and uses a portion of the resulting MAC as the next or new secret. The hash operation is performed with the
current 64-bit secret and the 64-bit challenge. Logical 1s are loaded in place of the ROM ID. 64 bits of the output
MAC are used as the new secret value. The host must allow tSHA after issuing this command for the SHA
calculation to complete, then wait tEEC for the DS2784 to write the new secret value to EEPROM. See Figure 10 for
command timing.
COMPUTE NEXT SECRET WITH ROM ID [33h]. This command initiates a SHA-1 computation of the MAC and
uses a portion of the resulting MAC as the next or new secret. The hash operation is performed with the current 64bit secret, the 64-bit ROM ID and the 64-bit challenge. 64 bits of the output MAC are used as the new secret value.
The host must allow tSHA after issuing this command for the SHA calculation to complete, then wait tEEC for the
DS2784 to write the new secret value to EEPROM. See Figure 10 for command timing.
LOCK SECRET [60h]. This command write protects the 64-bit secret to prevent accidental or malicious overwrite
of the secret value. The secret value stored in EEPROM becomes “final”. The host must wait tEEC for the DS2784 to
write the lock secret bit to EEPROM. See Figure 12 for command timing.
Table 10. Secret Loading Function Commands
COMMAND
Clear Secret
Compute Next Secret Without
ROM ID
Compute Next Secret With
ROM ID
Lock Secret
HEX
FUNCTION
5A
Clears the 64-bit Secret to 0000 0000 0000 0000h.
30
Generates new global secret.
33
Generates new unique secret.
60
Sets lock bit to prevent changes to the secret.
1-Wire BUS SYSTEM
The 1-Wire bus is a system that has a single bus master and one or more slaves. A multidrop bus is a 1-Wire bus
with multiple slaves, while a single-drop bus has only one slave device. In all instances, the DS2784 is a slave
device. The bus master is typically a microprocessor in the host system. The discussion of this bus system consists
of five topics: 64-bit net address, CRC generation, hardware configuration, transaction sequence, and 1-Wire
signaling.
64-BIT NET ADDRESS (ROM ID)
Each DS2784 has a unique, factory-programmed 1-Wire net address that is 64 bits in length. The term net address
is synonymous with the ROM ID or ROM code terms used in the DS2502 and other 1-Wire documentation. The first
eight bits of the net address are the 1-Wire family code (32h). The next 48 bits are a unique serial number. The last
eight bits are a cyclic redundancy check (CRC) of the first 56 bits (see Figure 6). The 64-bit net address and the
1-Wire I/O circuitry built into the device enable the DS2784 to communicate through the 1-Wire protocol detailed in
this data sheet.
Figure 6. 1-Wire Net Address Format
8-BIT CRC
48-BIT SERIAL NUMBER
MSb
30 of 38
8-BIT FAMILY
CODE (32H)
LSb
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
CRC GENERATION
The DS2784 has an 8-bit CRC stored in the most significant byte of its 1-Wire net address and generates a CRC
during some command protocols. To ensure error-free transmission of the address, the host system can compute a
CRC value from the first 56 bits of the address and compare it to the CRC from the DS2784.
The host system is responsible for verifying the CRC value and taking action as a result. The DS2784 does not
compare CRC values and does not prevent a command sequence from proceeding as a result of a CRC mismatch.
Proper use of the CRC can result in a communication channel with a very high level of integrity.
The CRC can be generated by the host using a circuit consisting of a shift register and XOR gates as shown in
Figure 7, or it can be generated in software using the polynomial X8 + X5 + X4 + 1. Additional information about the
Dallas 1-Wire CRC is available in Application Note 27: Understanding and Using Cyclic Redundancy Checks with
Dallas Semiconductor iButton Products.
In the circuit in Figure 7, the shift register bits are initialized to 0. Then, starting with the least significant bit of the
family code, one bit at a time is shifted in. After the 8th bit of the family code has been entered, then the serial
number is entered. After the 48th bit of the serial number has been entered, the shift register contains the CRC
value.
Figure 7. 1-Wire CRC Generation Block Diagram
INPUT
MSb
XOR
XOR
LSb
XOR
During some command sequences, the DS2784 also generates an 8-bit CRC and provides this value to the bus
master to facilitate validation for the transfer of command, address, and data from the bus master to the DS2784.
The DS2784 computes an 8-bit CRC for the command and address bytes received from the bus master for the
read memory, read status, and read/generate CRC commands to confirm that these bytes have been received
correctly. The CRC generator on the DS2784 is also used to provide verification of error-free data transfer as each
EEPROM page is sent to the master during a Read Data/Generate CRC command and for the 8 bytes of
information in the status memory field.
In each case where a CRC is used for data transfer validation, the bus master must calculate the CRC value using
the same polynomial function and compare the calculated value to the CRC either stored in the DS2784 Net
Address or computed by the DS2784. The comparison of CRC values and decision to continue with an operation
are determined entirely by the bus master. There is no circuitry in the DS2784 that prevents the command
sequence from proceeding if the stored or calculated CRC from the DS2784 and the calculated CRC from the host
do not match.
HARDWARE CONFIGURATION
Because the 1-Wire bus has only a single line, it is important that each device on the bus be able to drive it at the
appropriate time. To facilitate this, each device attached to the 1-Wire bus must connect to the bus with open-drain
or tri-state output drivers. The DS2784 uses an open-drain output driver as part of the bidirectional interface
circuitry shown in Figure 8. If a bidirectional pin is not available on the bus master, separate output, and input pins
can be connected together.
31 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
The 1-Wire bus must have a pullup resistor at the bus-master end of the bus. A value of between 2kΩ and 5kΩ is
recommended. The idle state for the 1-Wire bus is high. If, for any reason, a bus transaction must be suspended,
the bus must be left in the idle state to properly resume the transaction later. Note that if the bus is left low for more
than tLOW0, slave devices on the bus begin to interpret the low period as a reset pulse, effectively terminating the
transaction.
Figure 8. 1-Wire Bus Interface Circuitry
TRANSACTION SEQUENCE
The protocol for accessing the DS2784 through the 1-Wire port is as follows:
•
Initialization
•
Net Address Command
•
Function Command(s)
•
Data Transfer (not all commands have data transfer)
All transactions of the 1-Wire bus begin with an initialization sequence consisting of a reset pulse transmitted by the
bus master, followed by a presence pulse simultaneously transmitted by the DS2784 and any other slaves on the
bus. The presence pulse tells the bus master that one or more devices are on the bus and ready to operate. For
more details, see the 1-Wire Signaling section.
NET ADDRESS COMMANDS
Once the bus master has detected the presence of one or more slaves, it can issue one of the net address
commands described in the following paragraphs. The name of each net address command (ROM command) is
followed by the 8-bit op code for that command in square brackets.
Read Net Address [33h]. This command allows the bus master to read the DS2784’s 1-Wire net address. This
command can only be used if there is a single slave on the bus. If more than one slave is present, a data collision
occurs when all slaves try to transmit at the same time (open drain produces a wired-AND result).
Match Net Address [55h]. This command allows the bus master to specifically address one DS2784 on the 1-Wire
bus. Only the addressed DS2784 responds to any subsequent function command. All other slave devices ignore
the function command and wait for a reset pulse. This command can be used with one or more slave devices on
the bus.
Skip Net Address [CCh]. This command saves time when there is only one DS2784 on the bus by allowing the
bus master to issue a function command without specifying the address of the slave. If more than one slave device
is present on the bus, a subsequent function command can cause a data collision when all slaves transmit data at
the same time.
32 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Search Net Address [F0h]. This command allows the bus master to use a process of elimination to identify the
1-Wire net addresses of all slave devices on the bus. The search process involves the repetition of a simple threestep routine: read a bit, read the complement of the bit, then write the desired value of that bit. The bus master
performs this simple three-step routine on each bit location of the net address. After one complete pass through all
64 bits, the bus master knows the address of one device. The remaining devices can then be identified on
additional iterations of the process. See Chapter 5 of the Book of iButton® Standards for a comprehensive
discussion of a net address search, including an actual example (www.maxim-ic.com/iButtonBook).
FUNCTION COMMANDS
After successfully completing one of the net address commands, the bus master can access the features of the
DS2784 with any of the function commands described in the following paragraphs. The name of each function is
followed by the 8-bit op code for that command in square brackets. The function commands are summarized below
in Table 11.
Read Data [69h, XX]. This command reads data from the DS2784 starting at memory address XX. The LSb of the
data in address XX is available to be read immediately after the MSb of the address has been entered. Because
the address is automatically incremented after the MSb of each byte is received, the LSb of the data at address
XX + 1 is available to be read immediately after the MSb of the data at address XX. If the bus master continues to
read beyond address FFh, data is read starting at memory address 00 and the address is automatically
incremented until a reset pulse occurs. Addresses labeled “Reserved” in the memory map contain undefined data
values. The Read Data command can be terminated by the bus master with a reset pulse at any bit boundary.
Reads from EEPROM block addresses return the data in the shadow RAM. A Recall Data command is required to
transfer data from the EEPROM to the shadow. See Table 7 for more details.
Write Data [6Ch, XX]. This command writes data to the DS2784 starting at memory address XX. The LSb of the
data to be stored at address XX can be written immediately after the MSb of address has been entered. Because
the address is automatically incremented after the MSb of each byte is written, the LSb to be stored at address XX
+ 1 can be written immediately after the MSb to be stored at address XX. If the bus master continues to write
beyond address FFh, the data starting at address 00 is overwritten. Writes to read-only addresses, reserved
addresses and locked EEPROM blocks are ignored. Incomplete bytes are not written. Writes to unlocked EEPROM
block addresses modify the shadow RAM. A Copy Data command is required to transfer data from the shadow to
the EEPROM. See Table 7 for more details.
Copy Data [48h, XX]. This command copies the contents of the EEPROM shadow RAM to EEPROM cells for the
EEPROM block containing address XX. Copy Data commands that address locked blocks are ignored. While the
copy data command is executing, the EEC bit in the EEPROM register is set to 1 and writes to EEPROM
addresses are ignored. Reads and writes to non-EEPROM addresses can still occur while the copy is in progress.
The Copy Data command takes tEEC time to execute, starting on the next falling edge after the address is
transmitted.
Recall Data [B8h, XX]. This command recalls the contents of the EEPROM cells to the EEPROM shadow memory
for the EEPROM block containing address XX.
Lock [6Ah, XX]. This command locks (write protects) the block of EEPROM containing address XX. The lock bit in
the EEPROM register must be set to 1 before the Lock command is executed. To help prevent unintentional locks,
one must issue the Lock command immediately after setting the lock bit (EEPROM register, address 1Fh, bit 06) to
a 1. If the lock bit is 0 or if setting the lock bit to 1 does not immediately precede the Lock command, the Lock
command has no effect. The Lock command is permanent; a locked block can never be written again.
iButton is a registered trademark of Dallas Semiconductor, a wholly owned subsidiary of Maxim Integrated Products, Inc.
33 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Table 11. All Function Commands
COMMAND
HEX
DESCRIPTION
0C
Writes 64-bit challenge for SHA-1 processing. Required
immediately prior to all Compute MAC and Compute Next Secret
commands.
36
Computes hash operation of message block with logical 1s in
place of the ROM ID.
35
Computes hash operation of message block using the ROM ID.
5A
Clears the 64-bit secret to 0000 0000 0000 0000h.
30
Generates new global secret.
33
Generates new unique secret.
Lock Secret
60
Sets lock bit to prevent changes to the secret.
Read Data
69, XX
Reads data from memory starting at address XX.
Write Data
6C, XX
Writes data to memory starting at address XX.
Copy Data
48, XX
Copies shadow RAM data to EEPROM block containing address
XX.
Recall Data
B8, XX
Recalls EEPROM block containing address XX to RAM.
Lock
6A, XX
Permanently locks the block of EEPROM
containing address XX.
Set Overdrive
8B
Sets 1-Wire interface timings to overdrive.
Clear Overdrive
8D
Sets 1-Wire interface timings to standard (factory default).
Reset
C4
Resets DS2784 (software POR).
Write Challenge
Compute MAC
Without ROM ID and Return
MAC
Compute MAC
With ROM ID and Return MAC
Clear Secret
Compute Next Secret Without
ROM ID
Compute Next Secret With
ROM ID
34 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Table 12. Guide to Function Command Requirements
ISSUE MEMORY
ADDRESS
ISSUE 00h
BEFORE READ
READ/WRITE
TIME SLOTS
Write Challenge
—
—
Write: 64
Compute MAC
—
Yes
Read: up to 160
Compute Next Secret
—
—
—
Clear/Lock Secret, Set/Clear
Overdrive
—
—
—
Read Data
8 bits
—
Read: up to 2048
Write Data
8 bits
—
Write: up to 2048
Copy Data
8 bits
—
—
Recall Data
8 bits
—
—
Lock
8 bits
—
—
Reset
—
—
—
COMMAND
Figure 9. Compute MAC Function Command
tSHA
1-Wire
Reset
SKIP ROM
Cmd
Presence
Pulse
Up to 160 Read Time Slots
(Read 20-Byte MAC)
Wait for MAC
Computation
Compute
MAC
Cmd
8 Write 0
Time Slots
35 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Figure 10. Compute Next Secret Function Command
Figure 11. Copy Function Command
tEEC
1-Wire
Reset
SKIP ROM
Cmd
Copy
Cmd
8 Write
Time Slots
Wait for
EEPROM Programming
Presence
Pulse
Figure 12. Clear/Lock Secret, Set/Clear Overdrive Function Commands
36 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
I/O SIGNALING
The 1-Wire bus requires strict signaling protocols to ensure data integrity. The four protocols used by the DS2784
are as follows: the initialization sequence (reset pulse followed by presence pulse), write 0, write 1, and read data.
The bus master initiates all these types of signaling except the presence pulse.
The initialization sequence required to begin any communication with the DS2784 is shown in Figure 13. A
presence pulse following a reset pulse indicates that the DS2784 is ready to accept a net address command. The
bus master transmits (Tx) a reset pulse for tRSTL. The bus master then releases the line and goes into Receive
mode (Rx). The 1-Wire bus line is then pulled high by the pullup resistor. After detecting the rising edge on the DQ
pin, the DS2784 waits for tPDH and then transmits the presence pulse for tPDL.
Figure 13. 1-Wire Initialization Sequence
tRSTL
tRSTH
tPDH
tPDL
PACK+
DQ
PACKLINE TYPE LEGEND:
BUS MASTER ACTIVE LOW
DS2784 ACTIVE LOW
BOTH BUS MASTER AND
RESISTOR PULLUP
DS2784 ACTIVE LOW
WRITE-TIME SLOTS
A write-time slot is initiated when the bus master pulls the 1-Wire bus from a logic-high (inactive) level to a logic-low
level. There are two types of write-time slots: write 1 and write 0. All write-time slots must be tSLOT in duration with a
1μs minimum recovery time, tREC, between cycles. The DS2784 samples the 1-Wire bus line between tLOW1_MAX and
tLOW0_MIN after the line falls. If the line is high when sampled, a write 1 occurs. If the line is low when sampled, a
write 0 occurs. The sample window is illustrated in Figure 14. For the bus master to generate a write-1 time slot, the
bus line must be pulled low and then released, allowing the line to be pulled high less than tRDV after the start of the
write time slot. For the host to generate a write 0 time slot, the bus line must be pulled low and held low for the
duration of the write-time slot.
READ-TIME SLOTS
A read-time slot is initiated when the bus master pulls the 1-Wire bus line from a logic-high level to a logic-low level.
The bus master must keep the bus line low for at least 1μs and then release it to allow the DS2784 to present valid
data. The bus master can then sample the data tRDV from the start of the read-time slot. By the end of the read-time
slot, the DS2784 releases the bus line and allows it to be pulled high by the external pullup resistor. All read-time
slots must be tSLOT in duration with a 1μs minimum recovery time, tREC, between cycles. See Figure 14 and the
timing specifications in the Electrical Characteristics table for more information.
37 of 38
DS2784: 1-Cell Stand-Alone Fuel Gauge IC with Li+ Protector and SHA-1 Authentication
Figure 14. 1-Wire Write and Read-Time Slots
PACKAGE INFORMATION
For the latest package outline information, go to www.maxim-ic.com/DallasPackInfo.
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2007 Maxim Integrated Products
Products