ETC 613875

Eveready Battery Company, Inc.
R
Checkerboard Square
St. Louis, MO 63164
Telephone: 1-800-383-7323
Internet: www.energizer.com
Engineering Data
D
Rechargeable 1.2V
Nickel-Metal Hydride
ENERGIZER NO. NH50
Chemical System: Nickel-Metal Hydride (NiMH)
Dimensions (mm)
1.50
Minimum
34.20
32.20
9.50
7.80
Millimeters
.60
1.50
1.60
7.80
9.50
32.20
34.20
59.50
61.50
(+)
Designation: Not Assigned
Battery Voltage: 1.2 Volts
Average Weight: 73 grams (2.6 oz.)
Volume: 56.5 cubic centimeters (3.5 cubic inch)
Terminals: Flat Contact
Rated Capacity ( to 1.0 Volt ): 2.2 Ah
( Based on 440 mA (0.2C) discharge rate )
Maximum Charge Rate: 440 mA
Jacket: Plastic
Inches
.024
.059
.063
.307
.374
1.268
1.346
2.342
2.421
Internal Resistance
61.50
59.50
The internal resistance of the cell varies with state of charge, as follows:
Cell Charged
Cell 1/2 Discharged
11 milliohms
21 milliohms
(Tolerance of +- 20% applies to above values)
This dimension
applies contact
to contact
1.60
.60
(-)
AC Impedance (No Load)
The impedance of the charged cell varies with frequency, as follows:
Frequency (Hz)
Impedance (milliohms) (for charged cell)
TYPICAL DISCHARGE CHARACTERISTICS
Average Performance at 21°C (70°F)
1000
9
1.4
Note: Above values based on AC current set at 1.0 ampere.
Value tolerances are +- 20%.
Cell Voltage
1.3
1.2
1.1
220 mA
(0.1C)
440 mA
(0.2C)
1.0
0.9
0
2
6
4
8
10
12
Hours of Discharge
1.4
Operating and Storage Temperatures
Ranges of temperature applicable to operation of the NH50 cells are:
Charge @ 0.1C: 32°F to 122°F (0°C to 50°C)
Discharge @ 0.1C: -4°F to 122°F (-20°C to 50°C)
Storage: -40°F to 122°F (-40°C to 50°C) (6 Months Max.)
-4°F to 95°F (-20°C to 35°C) (2 Years Max.)
Operating at extreme temperature will significantly effect service and cycle life.
Cell Voltage
1.3
1.2
1.1
1.0
11 A
(5.0C)
0.9
0
20
2.2 A
(1.0C)
40
1.1A
(0.5C)
60
80
Minutes of Discharge
100
120
IMPORTANT NOTICE
This data sheet contains information specific to batteries manufactured at
time of its publication. Please contact your Energizer representative for most
current information. Contents herein do not constitute a warranty.
Form No. EPS - 7104B