ETC PSR-25

PHASE ANGLE POWER
25A ac
CONTROL MODULE
PSR-25
X10205
INTRODUCTION
The PSR-25 Power Control Module is a high power, full wave AC phase angle controller in a
compact package, capable of regulating up to 6KW (25A) 230V ac. The PSR-25 regulator governs
the amount of power supplied to the load, by controlling the phase angle of the AC supply. The low
thermal impedance and high electrical isolation provides the equipment designer with a greater
flexibility in a wide variety of applications.
APPLICATIONS
Suitable for quartz lamps, conventional resistive heating elements, including ovens, moulders and
dryers and some inductive loads (e.g. transformers and motors).
FEATURES
• Solid state reliability.
• Epoxy encapsulated.
• Simple wiring.
• Rugged and compact
• High current capability.
• Internal snubber.
INSTALLATION
COOLING REQUIREMENTS
INSTALLATION
SPECIFICATIONS
AC line voltage
Peak one cycle surge (10ms)
I2t for fusing
Isolation voltage
Max. operating temperature
110/230V +/- 10% @ 50/60 Hz
250A
250 A2s
5000Vrms
65°C
Unit limiting RMS current
Max peak voltage
Minimum operating current
Leakage current
Manual potentiometer (nominal)
Storage temperature
-20°C to +85°C
Manual potentiometer (nominal)
25A
600Vac
200mA
5mA
250K 1W @
230Vac
100K 1W @
110Vac
FUSING:
It is recommended to use semiconductor (fast acting) type fuses or circuit breakers (Semiconductor
- MCB) for unit protection. (See SRA Datasheet for further information).
CE MARKING
This product family carries a “CE marking”. These phase angle type controllers require a suitable remote
filter. For information see recommendation section and contact our sales desk. (See Declaration of
Conformity).
RECOMMENDATION
Other documents available on request, which may be appropriate for your applications.
CODE
IDENTITY
DESCRIPTION
X10229
RFI
Filtering recommendations - addressing the EMC Directive
X10213
ITA
Interaction, uses for phase angle and for burst fire control.
X10255
SRA
Safety requirements - addressing the Low Voltage Directive (LVD)
including :- Thermal data/cooling ; “Live” parts warning & Earthing
requirements; Fusing recommendations.
AP02/4
COS
UAL Conditions of sale
NOTE It is recommended that installation and maintenance of this equipment should be done with
reference to the current edition of the I.E.E. wiring regulations (BS7671) by suitably qualified/trained
personnel. The regulations contain important requirements regarding safety of electrical equipment. (For
International standards refer to I.E.C directive IEC 950).
ORDER CODE
State part number: PSR 25
Optional extras include: Potentiometer, Filter,Heatsink paste, Heatsink assembly
Note: When ordering a filter, the current the PSR is to be used at will be required.
UNITED AUTOMATION LIMITED
1 Southport Business Park
Southport, PR8 4HQ, U.K.
Page No 2 of 2 Issue 2
Tel (01704)-565713
Fax (01704)-569760
17/07/98